Loading...
2011, 11-17 Permit App: 11003586 AdditionProject Number: 11003586 Inv: 1 Application THIS IS NOT A PERMIT Penalties will be assessed for commencing work without a permit Date: 11/17/2011 Page 1 of 3 Project Information: Permit Use: 2ND STORY ADDITION & GARAGE EXTENSION Contact: CONSTRUCTION & ALL REMODELING Address: 1602 E CENTER RD C - S - Z: SPOKANE WA 99208 Setbacks: Front Left: Right: Rear: Phone: (509) 468-9996 Group Name: Site Information: Project Name: Plat Key: Name: Range District: East Parcel Number: 55073.0463 Block: Lot: SiteAddress: 17109 E MONTGOMERY AVE Owner: Name: CHANDLER, BOB W & KATHLEE Address: 17109 E MONTGOMERY AVE Location:: CSV SPOKANE VALLEY, WA 99016-855 Zoning: R-2 SF Res Suburban District Water District: 134 CONSOLIDATED ID #19 Hold: ❑ Area: .37 Acres Width: 0 Depth: 0 Right Of Way (ft): 0 Nbr of Bldgs: 0 Nbr of Dwellings: 0 Review Information: Review Building Plan Review Released By: Originally Released: 11/17/2011 By: tmelbourn Landuse/Zoning/HE Conditions Released By: Originally Released: 11/14/2011 By: mharnois Permits: Operator: MBB Printed By: JD Print Date: 11/17/2011 Project Number: 11003586 Inv: 1 Application THIS IS NOT A PERMIT Penalties will be assessed for commencing work without a permit Date: 11/17/2011 Page 2 of 3 Building Permit Contractor: CONSTRUCTION & ALL Firm: CONSTRUCTION & ALL REMDLN Address: 1602 E CENTER RD Phone: (509) 468-9996 SPOKANE, WA 99208 Building Characteristics Total Area 1020 Building Height 22 Stories 2 Dwelling Units 1 This Application: Total Project: Description Grp Type Notes Su Ft Valuation So Ft Valuation 2ND FLOOR R-3 VB LIVING 1,056 $78,365.76 1,056 $78,365.76 ADDITION GAR WOOD U -I VB GARAGE 420 $7,980.00 420 $7,980.00 EXTENSIO N Item Description RESIDENTIAL PERMIT FEE WSBCC SURCHARGE SF PLNS RVW < 7999 SQ FT Totals: 1,476 $86,345.76 1,476 $86,345.76 Units Unit Desc 1 SELECT 1 SELECT 1 SELECT Permit Total Fees: Plumbing Permit Fee Amount $902.75 54.50 $361.10 $1,268.35 Contractor: CONSTRUCTION & ALL Firm: CONSTRUCTION & ALL REMDLN Address: 1602 E CENTER RD Phone: (509) 468-9996 SPOKANE, WA 99208 Item Description Units Unit Desc Fee Amount TOILETS/BIDETS 1 NUMBER OF $6.00 SINKS 1 NUMBER OF $6.00 SHOWERS 1 NUMBER OF $6.00 CLOTHES WASHER 1 NUMBER OF $6.00 Operator: MBB Printed By: JD Permit Total Fees: $24.00 Print Date: 11/17/2011 Project Number: 11003586 Inv: 1 Application THIS IS NOT A PERMIT Penalties will be assessed for commencing work without a permit Date: 11/17/2011 Page 3 of 3 Notes: , FLORA ESTATES -REFER TO ADE -19-06 FOR LOT WIDTH/FRONTAGE-MH FLORA ESTATES -SEE FILE ADE -19-06 FOR LOT FRINTAGE/WIDTH-MH Payment Summary: Permit Type Fee Amount Invoice Amount Amount Paid Amount Owing Building Permit $1,268.35 $1,268.35 $422.14 $846.21 Plumbing Permit $24.00 $24.00 $0.00 $24.00 $1,292.35 $1,292.35 $422.14 $870.21 Disclaimer: Submittal of this application certifies the owner (or person(s) authorized by the owner) has bath examined and finds the information contained within to be true and correct, and agrees that all provisions of laws and/or regulations governing this type of work will be complied with. Subsequent issuance of a permit shall riot be construed to be a permit for, or an approval of, any violation of any of the provisions of the code or of any other state or local laws or ordinances. Signature: Operator: MBB Printed By: JD Print Date: 11/17/2011 *Wane jUalley� Community Development Department Permit Center 11703 East Sprague Avenue, Suite B-3 Spokane Valley, WA 99206 Tel: (509) 688-0036 Fax: (509) 688-0037 permitcenter(a}sookanevallev.orq (Staff Use Only) ) PERMIT NUMBER: 1 ( J 5 r} �j PERMIT FEE: RESIDENTIAL CONSTRUCTION PERMIT APPLICATION ❑ NEW CONSTRUCTION 'ADDITION/REMODEL ❑ ACCESSORY BUILDING ElDECK 111 OTHER RF SITE ADDRESS: //0 % G')'!D K? T6 C> Tfl y jT CITY 6F gPf1KANF VAI 1 FY ASSESSORS PARCEL NO.: 37073,at-a, 3 LEGAL DESCRIPTION: NOV 10 2011 BUILDING OWNER NAME: NAME: /3 0 R [V Q C HA'✓ 1 el?p ADDRESS: / 7 /0 / C 0A T Co me /V � �) 1 CITY: coe-e/V 4.(/ e.) STATE: 04/ PHONE: FAX: Cnwir7 l.L-w 1 LI I BY: M-k^r V ZIP: 7 / CELL: CONTACT NAME: PHONE: FAX: CELL: CONTRACTOR NAME: 6yI1 /-fj4 /ale (FoiilOPE ( Y?6 L MAILING ADDRESS: CITY: PHONE: '642 . ream 49D PO E STATE: w4 FAX: ZIP: 9 9,26...)S CELL: 509 S 7075— CONTRACTOR LICENSE NO.:C0%5T4I 9 I EXPIRES: CITY BUSINESS LICENSE NO.: DESCRIBE THE SCOPE J OF WORK IN DETAIL AND INDICATE SE & PROPOSED USE: Znd 5`,f 4dClpt'4-co / exeak `[irk C7 /''qckivt [eeie( 9 2? L C/vrtiC G{ ✓cCV L2oyr' ((fzOrvW <%s�P c -i < ****YOU MUST COMPLETE THE FOLLOWING**** MARK N/A IF NOT APPLICABLE Height to Peak: r Dimensions: 7 1: -Sli No. of Stories: off- Total Habitable Space: / Main Floor SQ FT:,, r1 (76(76,0)1Ya G /'fee Upper Floor SD FT_;,_Unfinished /Q, - Basement SQ FT: A- Finished Basement SQ FT: k.)It Garage SQ FT: Z ) 0.4 V Deck/Cdvered Patio SQ FT: A) /l Impervious Surface Area: 91 _ cF� 30% Slopes on Property: /1\14.- No. of Bedrooms: 1, Construction Type: Faiimk, Heat Source: 6.1 rbr Septic: TOTAL COST OF PROJECT: $ (XX). ° DISCLAIMER The permitted verifies, acknowledges and agrees by their signature that: 1) if this permit is for construction or on a dwelling, the dwelling is/will be served by potable water. 2) Ownership of this City of Spokane Valley permit inure to the property owner. 3) The signatory is the property owner or has permission to represent the property owner In this transaction. 4) All construction is to be done In full compliance with the City of Spokane Valley Development code. Referenced codes are available for review at the City of Spokane Valley Permit Center. 5) The City of Spokane Valley permit is not a permit or approval for any violation of federal, state or local laws, codes or ordinances. 6) Plans or additional information may be required to be submitted and subsequently approved before this application can be processed. Signature Date: G Updated 1-11-11 Page 1 of 1 http://www.spokanevalley.org/filestorage/124/938/210/948/1496/Building_Permit_-_Residential_11-11-11.doc RESIDENTIAL CHECK LIST DIRECTIONS: Place a check mark in box next to each document required for complete submittal. ®SITE PLAN rk Property lines and dimensions ® Direction arrow pointing North and orientation to streets a i Proposed/existing buildings (footprint and dimensions) © Utilities, septic tank/drain field locations and distances o Setbacks to property lines o Distance between buildings o Right of way/easement location & sizes o Driveway approach size and location BUILDING PLANS (3 SETS) (minimum 1/8 inch scale or completely dimensioned) t9 Elevations (Front/Rear/Sides) with roof peak and wall height including basement: o Foundation Plan (crawlspace, basement or slab on grade): o Footing sizes and locations o Perimeter concrete foundation wall sizes o Crawlspace ventilation o Supporting wood cripple walls or beams o Thickened concrete pads supporting beams or girder trusses O Floor Plan of each level (finished or unfinished) with dimensions: ❑ Floor Joist direction, size and spacing o Header, beam or concrete lintel sizes o Brace wall panel locations o Water heater and furnace locations o Exhaust fan locations o Deck or concrete patio sizes and locations ❑ Roof Plan: o Engineered truss direction and spacing o Rafter and over frame direction, size and spacing o Wall Section Detail including: Roof o Slope/ roofing material/ underlayment/ ice dam protection o Sheathing size and type Ceiling o Joist size and spacing Wall o Height/ top plate/ stud size and spacing/ sole plate o Exterior sheathing size and type Floor o Joist size and spacing Foundation Wall o Concrete or Masonry unit width o Earth to wood separation distance Footing o Size Radon ❑ Passive system with 6mil vapor barrier Miscellaneous Construction Details ❑ Deck: o Floor plari/ side view/ dimensions o Floor Joist/ decking direction, size and spacing o Stairway tread rise & run and nosing o Window and door location and sizes o Window well locations if applicable o Room usage labels o Smoke detector locations o Attic and crawl space access locations o Fire Wall construction o Ridge, eave and valley lines ❑ Beam and girder size and location ❑ Truss or rafter size, spacing & connection o Attic insulation/ air space baffle/ ventilation o Size of ceiling gypsum wall board o Siding/ exterior house wrap/ anchor bolts o Insulation, vapor barrier, gypsum wall board O Sheathing or concrete floor size/ insulation o Footing bottom to finished ground level depth ❑ Horizontal & vertical reinforcement if any o Reinforcement if any o Active system with 6 mil vapor barrier O Footings/ post/ and beam size and locations O Handrail / Guard height & spacing Spokaniannne� fey. 0 Permit Center 11703 E Sprague Ave, Suite 13-3 Spokane Valley, WA 99206 , (509)688-0036 FAX: (509)688-0037 permitcenter@spokanevalley. orp Community Development ' Plumbing Permit Application PERMIT NUMBER: PERMIT FEE: n Commercial Coesidential SITE ADDRESS: / 7/a 9 E M oNTCom 4 Y 3 r 144, 91v/$. Building Owner Name ` L N f ' Phon •. . • ✓ no Fax: Address. ,7ep 9 1 nul Airrpti 4V t,City: /gyp) lM y�cAtistatc: t_/ Zip: 99�r e, (( i' ¢'*+ 't� / Pp'.`` 1® !� .! i/� 7 7 f Contractor V' Name: Phone: Fax: Address: City State: Zip: License No: City Business Lic Contact/Project Manager: Name: Phone: # OF UNITS PLUMBING FIXTURE ON A TRAP TOILETS , j URINALS TUBS SHOWERS (per trap) i SINKS Lav/Basins, Bar, Floor, Kitchen, Laundry, Utility, Janitor, Photo, X-ray, Food, Prep/Culinary Meat DISHWASHER CLOTHES WASHER I GARBAGE DISPOSAL WATER SOFTNER FLOOR DRAIN Area, Case, Coil, Trench, Condensate ROOF DRAIN/OVERFLOW DRAINS FOUNTAIN, DRINKING WATER PIPING/DRAIN-IN WASTE Installation, Alterations, Repair, Reversals WATER USING DEVICE Ice and/or Coffee maker, hose bib, steamer proofer, carbonator, swamp cooler PRIVATE SEWAGE DISPOSAL SYSTEM NO WATER HEATER If Gas, See Mechanical INDUSTRIAL WASTE PRETREATEMENT INCEPTORS Including traps, vents except kitchen type grease interceptors functioning as fixture traps REPAIR OR ALTERATION Water piping, drainage or vent piping ATMOSPHERIC TYPE VACUUM BREAKER BACK FLOW PROTECTIVE DEVICE Other than atmospheric type vacuum breakers MEDICAL GAS INCEPTORS ❑CASH D CHECK D VISA DMC Card# SIGNATURE: EXPIRES: VIN RE: EVED s;Y CITY OF SPOKANE VALLEY NOV 10 2011 VERMIT CENTER Bl: _d i c,IL CURRENT FEES AVAILABLE AT: http://www.spokanevalley orq/ under the quick links for Forms, Master Fee Schedule. http./fwww spokanevalley org/uploads/Community_Development/Documents/Forms/Building/PlumbingPermitApplication040309.doc Sp®ltane #Valley Target Date sheet For City Use Only PLUS Project H- 3Si3� Project Address 1"iWe? 1= Jt'1,.,4 c„,.„ St' 11703 E Sprague Ave Suite B-3 1 Spokane Valley WA 99206 509.720-5240 1 Fax: 509.688.0037 1 permitcenter@spokanevalley.org As part of our on-going commitment to customer service during the review process of your project application, we are providing you with a TARGET DATE for the initial technical application review. If for any reason we cannot meet this date, we will contact you with a revised target date. 0 1 — 1 7 reed on 1.1-1 4++ Your application review TARGET DATE is uJ0 : t� I 's. n f f 40 PP av,c, Uv1 �11���.ni u � Y-ror� / l The TARGET DATE is the date we estimate your project application will have had its initial technical review. It is not the date for approval or permit issuance. Tips for a Smoother Project Application Review > Submit complete, accurate plans and documents. Extra time may be required for re -submittals as project application reviewers work on multiple applications and it may he several days before they can look at your new or revised information. > Designate a specific contact person to communicate with the City. While the person designated as the applicant's contact person with the City can he changed, one individual with the expertise for dealing with reviewer comments would be the best choice for the entire review process. ➢ Call staff regarding the status of your project only after the target date shown at the top of the page Although you should he contacted on or by the target date, please feel lite to contact us if you haven't heard from us by your target date. Staff -may contact you before the target date if the initial review is complete. By following this procedure, you will save time and allow the reviewers to complete the work morcexpeditiously. Steps in the Permit Process 1. Counter Complete. Your application has been accepted as counter complete. This means all of the required documents, as indicated on your Pre -Application Checklist have been submitted or have been approved for deferred submittal. This does not prevent technical staff from requesting additional information as a result ol'their technical review. 2. Quality Check. The next step in the process is a quality check to make sure that the application is reviewable and free from substantije flaws that would prevent technical staff from completing the technical review once it is started. When this step is complete, your application will be routed to the appropriate staff and remain in their review queue until it comes up for review. 3. Technical Compliance. Once an application is administratively complete, it is routed to technical staff for compliance review. Depending on the type of project, technical staff may include multiple reviewers. You should be contacted by phone, fax, email, or mail by your TARGET DATE once the initial technical compliance review is complete. 4. Permit Issuance. When the technical compliance review of the application is complete, including any subsequent re - submittals, each reviewer will approve their section of the application and route it to the Permit Center. When all sections of the application are received, a Permit Specialist will process the application and contact the person specified on your application for permit pick-up. Information regarding fees and pre -construction meetings (if required) will be provided by the Permit Specialist at that time. CD -003 V-7/ 06-21-11 Page 1 of 1 S ,Y ir PAP c4 No' 'fa7f 01&3 iofryivs Hvj cS etS (4v (P_ L;Vi OD } mor. c 37 Pula D 13Y CITY 0 SPOKANE VALLEY NOV 10 2011 rtI3MIT CEN 1 trs rr l� 5���12 ,/,7e2 o .ti ofio —7:10 AppRovcD M 91 MEMORANDUM DATE 11/23/11 TO CHANDLER RESIDENCE/CONTRACTOR/BUILDING DEPT FROM CANENG STRUCTURAL CONSULTING (CRAIG NIELSEN) ATTN: WES MILLER/BLDG OFFICIAL RE. Chandler Residence 17109 E. Montgomery Spokane Valley, WA 1 visited the Chandler residence job site on Tuesday, November 23, 2011 to observe the soil and rock conditions that have been unearthed. It is my professional opinion the footing must maintain specified footing depth on the engineered plans The footing can span over the top of the exposed boulders as long as the reinforcement is continuous with lap splices as required If you have any questions or comments please contact me at your convenience Craig A Nielsen P.E. (509) 951-5075 Email caneng@comcast.net comcast.net II EXPIRES 09/23/ RE 'EIVED BY CITY OF SPOKANE_ VALLEY NOV 2 3 2011 vtHMll GEN 1 EH BY: MEMORANDUM DATE: 03/06/12 TO: CHANDLER RESIDENCE/CONTRACTOR/BUILDING DEPT FROM: CANENG STRUCTURAL CONSULTING (CRAIG NIELSEN) ATTN: WES MILLER/BLDG. OFFICIAL/OWNER RE: Chandler Residence 17109 E. Montgomery Spokane Valley, WA I visited the Chandler residence job site on Wednesday, March 6, 2012 to observe the building/framing/foundation process to date. The shear walls have been correctly blocked and connected to framing. The foundation set-up at post bearing locations (2 total) are ready for concrete pour. The overall construction looks to be compliant with engineered plans and the construction process should move forward. If you have any questions or comments please contact me at your convenience. Craig A. Nielsen P.E. (509) 951-5075 caneng@mail.com I EXPIRES 09/23/ 13