2015, 03-06 Permit App: BLD-2015-0412 Addition ShopSpolane
..;oOValley
Community Development Department
Permit Center
11703 East Sprague Avenue, Suite B-3
Spokane Valley, WA 99206
Tel: (509) 720-5240
Fax: (509) 688-0037
peermitcenter@sooka neva I lev.ora
(Staff Use Only)
PERMIT NUMBER'
PERMIT FEE'
RESIDENTIAL CONSTRUCTION PERMIT APPLICATION
❑ NEW CONSTRUCTION ❑ ADDITION/ REMODEL ACCESSORY BUILDING
DECK ❑, OTHER
SITE ADDRESS: `b l - h1 Dov T C -D M r
ASSESSORS PARCEL NO.: i7 ( � U I EGAL DESCRIPTION:
OWNER/APPLICANT (CHECK BOX, IF MAIN CONTACT
Project -;;�
NAME: L) n n
ADDRESS'
CITY STATE' y"Q n ih oma
FAX: EMAIL:
PHONE: SV ENTER
CONTACT NAME:
PHONE: FAX: ---�
CONTRACTOR NAME (CHECK BOX, IF MAIN CONTACT 2): &PAJ 4DH
MAILING ADDRESS: Z
CITY: S Iw it V
PHONE: S Del
CONTRACTOR LICENSE NO.:
STATE: VJ1
REV.
ZIP: Z O 4,
j� FAX:
1 EMAIL' i^u%lE S tCC�' �r�j lfjyl-1 C!
§I01v EXPIRES: I 1 -7,01 G CITY BUSINESS LICENSE NO.:
DESCRIBE THE SCOPE OF WORK IN DETAIL AND INDICATE USE & PROPOSED USE:
****YOU MUST COMPLETE THE FOLLOWING****
IMAM! N /A TIG NAT APPI_TCARLE
Height to Peak: t
Dimensions:
No. of Stories:
Total Habitable
space:
Main Floor SQ FT:
Upper Floor SQ FT:
Unfinished Basement SQ
Finished Basement SQ
.
Z
!_
FT' C
FT:
Garage SQ FT:
Deck/Covered Patio SQ
Impervious Surface
30% Slopes on
FT: �-
Area: ,,
Property:
No. of Bedrooms:
Construction Type:
Heat Source:
Sewer or Septic:
TOTAL COST OF PROJECT: $ 6"-),,-
DISCLAIMER
`),,
DISCLAIMER
The permitted verifies, acknowledges and agrees by their signature that: 1) If this permit is for construction or on a dwelling, the dwelling
Is/will be served by potable water. 2) Ownership of this City of Spokane Valley permit inure to the property owner. 3) The signatory is the
property owner or has permission to represent the property owner in this transaction. 4) All construction is to be done In full compliance
with the City of Spokane Valley Development code. Referenced codes are available for review at the City of Spokane Valley Permit Center. 5)
The City of Spokane Valley permit is not a permit or approval for any violation of federal, state or local laws, codes or ordinances. 6) Plans
or additional information may be required,�o be submitted and subsequently approved before this application can be processed.
Signature ! /f Date: 6- %S
RESIDENTIAL BUILDING PLAN CHECKLIST
❑ SITE PLAN (2 COPIES): Refer to Residential Site Plan Guide
SI61;4Sbestog"\tm,
Valley®
❑ MECHANICAL & VENTILATION FORM (2 COPIES): Available at www.spokanevallev.orq
❑ BUILDING PLANS (2 SETS): Drawn/drafted to scale with the information described below, as applicable:
(2012 International Residential Code references included in italicized text)
❑ ELEVATIONS
❑ Show front/rear/sides of proposed building
❑ Identify roof peak and wall height (incl. basement)
❑ FOUNDATION PLAN
❑ Identify crawlspace, basement or slab on grade
o Footing sizes and locations R403.1.1
❑ Horizontal & vertical reinforcement R404.1.2.2
o Supporting wood cripple walls or beams R602.9
❑ Concrete foundation wall sizes R404.1.2
❑ Concrete pads supporting beams or girder trusses
❑ Crawlspace ventilation R408
❑ Radon mitigation system IRC Appendix F
❑ FLOOR FRAMING PLAN of each level:
o Floor joist direction, size and spacing R502.3
❑ Header, beam & concrete lintels R502.5/R611.8
❑ ROOF FRAMING PLAN
❑ Eng. truss direction/spacing/connection 8802.10
❑ Rafter direction/spacing/connection R802
❑ Overframing R802
❑ Ridge, eave and valley lines
❑ Header/girder/beam sizes and locations R502.5
❑ Roof and ceiling slope
o Roofing/underlayment/ice dam protection R901.1
o Attic insulation/baffles/ventilation R806.1
❑ BUILDING CROSS-SECTION DETAIL showing:
❑ Roof
❑ Ceiling
❑ WaII
❑ Floor(s)
❑ Foundation Wail
o Footing
O FLOOR PLAN of each level:
❑ Identify finished or unfinished areas
❑ Identify dimensions of each room
❑ Window & door location & sizes R310/R311
❑ Window well locations, if applicable R310.2
❑ Label use of each room/area
❑ Water heater location Chapter 24
❑ Furnace location M1401/Chapter 24
❑ Smoke/CO detector locations R314/R315
❑ Whole house ventilation location R303/M1507.1
❑ Exhaust fan locations R303/M1507.1
❑ Attic/crawl space access locations R408.4/R807.1
❑ Deck or concrete patio sizes and locations
❑ Fire resistant wall construction R302.6
❑ Braced wall panel locations/method R602.10
❑ MISCELLANEOUS CONSTRUCTION DETAILS
Decks/Patios
❑ Floor plan with dimensions
❑ Elevations (front- and side -view)
❑ Footings/posts/beam size and locations R403.1.1
❑ Joist/decking direction/size/spacing R502.3
❑ Fasteners/attachment to structure R507.1
Stairways (interior and exterior)
❑ Stair tread rise/run/nosing dimensions R311
❑ Handrail height and picket spacing R311.7.8.1
❑ Guard height and picket spacing R312
❑ ENERGY CODE PACKET
❑ download WA State Energy Code worksheets at:
www.wsu.edu/BuildingEfficiency/EnerqvCode.aspx
❑ Prescriptive / Component Performance worksheet
❑ Glazing (window/skylight) schedule worksheet
❑ Heating system sizing worksheet
HELPFUL LINKS WHEN PREPARING YOUR CONSTRUCTION PLANS:
-International Code Council free eCode access:
-Washington State Building Code Council:
-Spokane Valley Municipal Code:
http://publicecodes.cvberreqs.comlicod/index.htm
https://fortress. wa.gov/qa/apps/sbcc/Page. aspx?nid=14
http://www.codepublishinq.com/wa/spokanevalleW
Project !# 15C C->-'2o1S CY4IA
RECEIVED pq
MAR 0 6 2015
CSV PERMIT CENTER
UB # REV.
• PLANNING DEPT. APPROVED
0
d
DATE- uV I
16'
10 pY
SOL -fyi AZDJT--T-."
rn
�
m�
414 cz
7r
p COLL #NrA ItTr'
k, lbf ptmr,
IM
I
I I " C o J CIL VIA— Ct A;S
PC- 4� 2 orV IN"
REVIEWED FOR CODE COMPLIANCE
SPOKANE VALLEY BUILDING DIVISIO
FILE
6 ��