Loading...
2007, 06-15 Permit App: 07002298 DeckBUILDING DIVISION S*614ne Valley 11707 E. Sprague Avenue, Suite 106 •7 Spokane Valley, WA 99206 C TEMPORARY PERMIT PROJECT NUMBER (",2LL-27�l , SITE ADDRESS ISSUE DATE - = ; _ -r PARCEL NUMBER PERMIT USE -j�'( j=l, ; ;,�2X-A SUBDIVISION BLOCK/LOT APPLICANT ZONING OWNER ADDRESS . 7,77 c'\ r CONTACT BUILDING INSPECTOR WATER DIST. SETBACKS FRONT INSPECTION LINE 509-688-0054 RIGHT LEFT REAR GROUP NAME PROJECT NAME PERMITS PERMIT TYPE CONTRACTOR: LICENSE# ! it ted. .......�.� � ®.£ ,-.�........_..,.e..,....., _ .. S ; t i PAYMENT SUMMARY TRANS DATE TOTAL FEE AMT OWING RECEIPT # PMT AMT _.. . Q £ £ NOTICE The ownership of a Spokane Valley Development Permit will inure to the property owner. The permit applicant, by definition, is the property owner or an authorized agent of the property owner. It is the responsibility of the applicant/permittee that the use described on the front of this permit complies with applicable codes and that required inspections are requested. Failure to request inspections as listed below and obtain the necessary approvals before progressing beyond the point where inspections are required may necessitate removal of certain parts of the construction at the applicant's/permittee's or property owner's expense. At a minimum, the following inspections ARE REQUIRED by City Code: FOOTING — when forms and reinforcement are in place and prior to placement of concrete -all structures, including manufactured homes. NOTE: This inspection includes review of the structure's setback from property lines. Minimum setbacks are established by City of Spokane Valley Ordinance. Curb lines and fence lines are not necessarily indicative of property lines. The responsibility to comply with applicable setback provisions lies solely with the permittee -neither the City of Spokane Valley nor its authorized representatives assume any responsibility for the verification or location of your property lines. Please verify their location prior to locating your structure. Failure to properly locate the structure may require its relocation at the owner's/permittee's expense. FOUNDATION — when forms and reinforcement are in place and prior to placement of concrete. PLUMBING — after rough -in, before covering, and final. MECHANICAL — rough -in of piping, before covering, metal chimneys before concealment, and final. FRAMING — after all framing, bracing and blocking is in place, rough electrical, plumbing and mechanical systems are complete, and prior to concealing. FINAL — when complete and prior to occupancy and/or use. All permits require final inspection. NOTE: In addition to inspection of the structure, this inspection includes review of site improvements (typically depicted on the approved site plan) required by ordinance or as a condition of approval of this permit. Items such as the installation of fire hydrants, fire department access, on-site drainage ('208' swales), road improvements, parking and landscaping are common requirements of a permit/site plan which must be completed prior to final approval of a building or issuance of a Certificate of Occupancy. MANUFACTURED HOMES — Final inspection required when complete, stairs, handrails, skirting, etc. installed, and prior to occupancy; completed inspection record card must be available on site. PLUMBING REVERSALS FOR SEWER CONNECTIONS — prior to cover. RIGHT-OF-WAY/APPROACH — prior to placement of concrete/asphalt or, if gravel approach, after completion. In addition to the above, any plumbing or mechanical systems or material which would be concealed by framing, drywall, concrete, etc. must be inspected prior to cover. Check with the Building department for "special inspections" in conjunction with commercial projects. FOR INSPECTIONS Please give one working day/24 hour notice. Different parts of your project may require permits and inspections from more than one agency. Building, plumbing (includes interior reversals for sewer) and mechanical, City of Spokane Valley Building Division 688-0054 Permits and inspections for electrical wiring, State Department of Labor And Industries 324-2640 Permits and inspections for on-site septic systems, Spokane Regional Health District 324.1560 Road cuts for utilities or driveways, City of Spokane Valley Public Works 688-0195 or State Dept of Transportation 324-6000 Permits and inspections for Sewer Connection, Spokane County Utilities Division 4773604 Fire sprinkler and alarm systems and private access road inspections, Spokane Valley Fire Department 892-4122 State law RCW 19.122 requires that prior to any excavation the "CALL BEFORE YOU DIG' center must be notified. Call before you dig at least 2 working days in advance, 456.8000. PERMIT EXPIRATION AND REFUNDS All permits shall expire by limitation and be declared void if a) work is not started within 180 days of obtaining a permit, or b) work is abandoned for 180 days or more after beginning work, or c) after two years from the date of permit issuance, regardless of whether the work is finished. If a permit is expired for time, a new permit may be obtained for half the permit fee based on the value of the remainder of the work to finish the original permit. All refund requests must be made in writing by the original permittee to the Building Official no later than 180 days after the date of fee payment. 100% refunds will be granted for any fee erroneously paid or collected. Refunds of not more than 80% of a permit fee may be authorized when no work has been done under the permit issued. Refunds of not more than 80% of a plan review fee paid may be authorized when an application is withdrawn or cancelled prior to the plan review being completed. i Owner /Agent Date (' " Staff Approval Date Project -Number: 07002298 Inv: I Application Date: 6/15/2007 Page 1 of 2 THIS IS NOT A PERMIT Penalties will be assessed for commencing work without a permit Proiect Information: Parcel Number: 45203.0133 SiteAddress: 908 S NINA CIR Block: 1 Lot: 5 Location:: CSV `I , 7 Zoning: UR -7 Urban Residential -7 Water District: Area: 1,500.00 Acres Width: 0 Nbr of Bldgs: 0 Nbr of Dwellings: 0 Review Information: Owner: Name: HAYES, WAYNE Address: 908 S NINA CIRCLE SPOKANE VALLEY, WA 99206 Hold: ❑ Depth: 0 Right Of Way (ft): 0 Review Flood Plain Released By: Building Plan Review Released By: Landuse/Zoning/HE Conditions Released By: z �/ 7 Permits: Operator: JD Printed By: JD Print Date: 6/15/2007 Project -Number: 07002298 Inv: I Application Date: 6/15/2007 Page 2 of 2 THIS IS NOT A PERMIT Penalties will be assessed for commencing work without a permit Contractor: TODD W FREUND Address: 10006 NE 81ST ST VANCOUVER WA 986622923 Building Permit Firm: TODD W FREUND CONSTRUCTIO Phone: (360) 883-6556 Notes: �... Payment Summary:,:. Permit Type Fee Amount Invoice Amount Amount Paid Amount Owing Building Permit $140.65 $140.65 $0.00 $140.65 $140.65 $140.65 $0.00 $140.65 Disclaimer: Submittal of this application certifies the owner (or person(s) authorized by the owner) has both examined and finds the information contained within to be true and correct, and agrees that all provisions of laws and/or regulations governing this type of work will be complied with. Subsequent issuance of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the code or of any other state or local laws or ordinances. Signature: Operator: JD Printed By: JD Print Date: 6/15/2007 This Application: Total Project: Description Grp Type Notes Sg Ft Valuation Sg Ft Valuation COV DECK R-3 VB 252 $3,780.00 252 $3,780.00 Totals: 252 $3,780.00 252 $3,780.00 Item Description Units Unit Desc Fee Amount RESIDENTIAL PERMIT FEE 1 SELECT $97.25 WSBC SURCHARGE 1 SELECT $4.50 SF PLNS RVW < 7999 SQ FT 1 SELECT $38.90 Permit Total Fees: $140.65 Notes: �... Payment Summary:,:. Permit Type Fee Amount Invoice Amount Amount Paid Amount Owing Building Permit $140.65 $140.65 $0.00 $140.65 $140.65 $140.65 $0.00 $140.65 Disclaimer: Submittal of this application certifies the owner (or person(s) authorized by the owner) has both examined and finds the information contained within to be true and correct, and agrees that all provisions of laws and/or regulations governing this type of work will be complied with. Subsequent issuance of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the code or of any other state or local laws or ordinances. Signature: Operator: JD Printed By: JD Print Date: 6/15/2007 Spokane jValley Permit Center 11703 E Sprague Ave, Suite B-3 Spokane Valley, WA 99206 (509)688-0036 FAX: (509)688-0037 www.Wokanevalley.org PERMIT NUMBER PERMIT FEE: Community Development '�� �i r + Residential Construct'1� ❑ New Construction ❑ Accessory Bldg Permit Application F-1 Addition/Remodel F-1 Deck ❑ Other: SITE ADDRESS: S ek,�ht V*-IL1.-, 4�ZOro �C��3 S U1 N� Gr p ASSESSORS PARCEL NO: 4 � 2-0-S. 0 13.3 LEGAL DESCRIPTION: Building Owner: Name: Address: qo'6 City: d <<<�L ` State: Zip: ���� Phone: , )1112Fax: Contact Person Name: TLyA& revr Phone: Contractor: " DIMENSIONS: Name: Toch c� ,Y TOTAL HABITABLE SPACE: Address: I C�Op tv( City: V r.r«W vt/ State: w V gn— Zlp''T$6 (. Phone: SG- ,— cr L T Fax:3Lo _ ZIb— 7S 11 Contractor Lic No: w Q.. Exp Date: City Business Lic. No: Describe the scope of work in detail: Cost of Project: $ wT t 4 ).(- t B -if/ Proposed Use: r.i;,f in�'l(1( e e **************ThP following MITST he complete: (write N/A if not applicable)********************** HEIGHT TO PEAK: _ DIMENSIONS: # OF STORIES: TOTAL HABITABLE SPACE: MAIN FLOOR TO SQ. 2 NLFLOOR SQ. FTG: UNFIN BASEMENT SQ. FTG: IMPERVIOUS SURFACE FTG: AREA: FINISHED BASE ENT GARA E SQ. FTG: DEC COV. PATIO -'SQ. FTG: 30% SLOPES ON SQ. FTG: Jte *,a, 0 (L TY: # OF BEDR OMS: CONSTRUCTION TYPE: HEAT SOURCSEWER R SEPTIC? ,GY C. V- '74e:'C' rr `c— The permitee verifies, acknowledges and agrees by their signature that: 1) If this permit is for construction of or on a dwelling, the dwelling is/will be served by potable water. 2) Ownership of this City of Spokane Valley Permit inure to the property owner. 3) The signatory is the property owner or has permission to represent the property owner in this transaction. 4) All construction is to be done in full compliance with the City of Spokane Valley Development Code. Referenced codes are available for review at the City of Spokane Valley Permit Center. 5) This City of Spokane Valley Permit is not a permit or approval for any violation of federal, state or local laws, codes or ordinances. 6) Plans or additional information may be required to be submitted, and subsequently approved before this application can be processed. ,�-/ SIGNATURE: DATE: ,: �- l%rr�.:N Method of Payment: ❑ Cash ❑ Check ❑ Mastercard ❑ VISA Bankcard #: Expires: VIN#: Authorized Signature: REVISED 2/15/07 11703 E Sprague Ave Suite B-3 ♦ Spokane Valley WA 99206 509.688.0036 ♦ Fax: 509.688.0037 ♦ cityhaL[@spokanevalley.org Residential Plan Submittal Minimums ❑ Completed Building & Mechanical application with: Accurate address, Parcel Number and/or Legal Description, description of work, owner and contractor information, signature, and date. ❑ Two sets of plans including Site Plan, elevations, floor plans, foundation plans With details, roof plan, framing plans & details. ❑ Show the height of any proposed buildings or accessory structures. ❑ Floor plan for each floor: Dimension to scale (minimum 1/8") and label each Room (including sq. footage of house and garage on plans) Show each level of existing house and square footage of any additions. ❑ All braced wall panel types: show locations and details of installation, including engineered design. ❑ Egress windows: Provide at least one window or exterior door approved for Emergency escape or rescue from a basement and in every room for sleeping. ❑ Smoke detector locations ❑ 22" X 30" attic access location ❑ 18" X 24" crawl space access: ❑ One-hour separation detail: between house and garage ❑ Floor framing details: Joist type, size, spacing and installation details ❑ Roof framing plan and details ❑ Furnace and hot water heater location. ❑ All header locations: type, size, and connections ❑ Foundation plan ❑ Insulation information q03n., Cf A 9 'Al PLANNING DEPT. APPROVED BY: DATE: `L 5 LG 8'f IILI�III 3� Inclk ply -- 2X2 flc, 05 19 MAR)( Sod- �qo-S3.2o Decking ilainnun en eager. ileum Gem edge of amber to Center of bolt Ie be 1.1G" minimum If peeler then 4'-0" pneldo ■ ode. of 4.4 braces el pest. Iekbeomoneneelions (Mulmom Pest Height shell not be more than 10 foot) Pal vialbaeesp 1" min. above concrete or y - provide treated wood 24/r minimum .1 '1=1. 1=1 iolmum 2000 psi holing 3" minimum Natural pude_ .44----- T min to drlylight • —Ilse .e f. jZ" H water than 4'-e" pnvld, a mlo. of 4e4 Immo at pull. to-beweonnmtlom (Mutinous Poet Height shell not be mon on 1016s1) Mal baeeep 1" min. above concrete or Ids d wood Post do Beam Connection detail (interior condition) Post Cep Installed per manulhotuer', Imlruelien 2000 psi concrete (minimu T' minimum 6"minhnom Ndurol Grade 24" inlnimum Ir min. (4.4) Knee brae, Two 1/2" diameter les belle top end bottom typical Pat 10" min. (4.4) Knep breoe elm 24" mea. I Overhang ludger enechmenl must be boiled through Post tk Beam Connection detail oil cep Installed per mnmlhcluler'e Inrlruate Is" min, (4a4) Km. knee if0z� � , ' �fy� }UUIJJII t.I1A4 rr ) 'ti}'lust }y17 ��- ,�r�il I��7 I!I1�1 01�}ll 6" min. (4.4) Knee brie, p.". Two 1/2" dimmer lag bolls lop and bottom typical 1.,41N-. SPHERE CANNOT RJLL301N. MIN GUARD PA88 THRQUGH HEIGHT PER SECT. 8310.1 AT LANDING 3a• SPHERE CANNOT THROUGH 34 IN. MIN GUARD HEIGHT PER SECT. 8310. 130 IN. MAX FOR HANDRAIL PER SECT. 8310.1 Rw -v�: NOR4OSRI OP" N.NODt ���p...►MO�R MOP IN.1KOWM . ORp11NN �Y VYMLAIl01MOIIK ronowIDPAL L111�T� �ozal lna raowllrRllOocw°1 cum ��" &OWNS NOI/O�IONIMIMNOlY1L OPEN RISER PERMITTED_41N. SPHERE WILL NOT PASS THROUGH OR WHERE HEIGHT OF STAIR 18 LE88 THAN 30 INCHES " �Yim"!-NVAI it 0 WA 1004. MIN RUN MAX. RISE 73141N. VARIATION OP RIBER HEIGHTS OR TREAD DEPTHS SHALL NOT EXCEED %IN. > ,s r2 Roofinn malarial OS !� BE A.vV1 /8" GAP EEIV SHEATHING 7 18" minimum width I� Existing `\X 1 rafters 2x blocking 4"'K � L--�-v -v— r-I Existing wall Nevi rafter to existing bearing size 2, x � 5 l S g TA c h :king f� Beam size st size 7 x b (4 x 4 minimum) acing _ 7 -ft (6 x 6 recommended) Pre-engineered bracket DESIGNED F:b2. UPLI P minimum depth Existir^ wall Continuous 2x ledger ' I ' woo 1 L Bracing required Approved metal bracing PROVIDE DIAGRAMS AND ENGINEERING LAYOUTS FOR ROOF TRUSSES, BEAMS AND FLOOR SYSTEMS PRIOR TO FRAMING INSPECTIONS CITY COPY THIS BUILDING TO FIELD INSPECTION CORRECTIONS REVIEWEL " L : COMPLIANCE SPOKANE VISION 10 7 ---