2008, 06-13 Permit App: 08002228 Finish BasementPrbject Number: 08002228 Inv: I
Application
THIS IS NOT A PERMIT
Penalties will be assessed for commencing work without a permit
Date: 6/13/2008 Page 1 of 2
Project Information:
Permit Use: FINISH BASEMENT
Setbacks: Front
Left: Right: Rear:
Site Information:
Plat Key: 006070 Name:
Contact: FLORIANOVICH, ALEXEY
Address: 14121 E 23RD AVE
C - S - Z: SPOKANE VALLEY WA 99037
Phone: (509) 768-0273
Group Name:
Project Name:
AUTUMN PLACE
District: East
Parcel Number: 45234.5514 Block: 1
SiteAddress: 1111 S NEWER CT
Location:: CSV
Zoning: MF -1 MF MDR District
Water District: 011 MODERN
Area: 11,835 Sq Ft Width: 80
Nbr of Bldgs: 1 Nbr of Dwellings: 1
Lot: 14
Owner: Name: THOMPSON, GINA R
Address: 1111 S NEWER CT
SPOKANE VALLEY, WA 99037
Hold: ❑
Depth: 147 Right Of Way (ft): 36
Review Information:
Review -
Building Plan Review
Permits:
Released By:
Originally Released: 6/12/2008 By: tmelbourn
D
Building Permit
Contractor: AF CONSTRUCTION LLC Firm: AF CONSTRUCTION LLC
Address: 14121 E 23RD AVE Phone: (509) 926-1456
SPOKANE VALLEY WA 99037
This Application: Total Project:
Description Grp Tvpe Notes Se Ft Valuation Sq Ft Valuation
BASEMENTF R-3 VB BASEMENT 0 $10,000.00 0 $10,000.00
FINISH
Item Description
RESIDENTIAL PERMIT FEE
WSBC SURCHARGE
SF PLNS RVW < 7999 SQ FT
Totals: 0 $10,000.00 0 $10,000.00
Units Unit Desc Fee Amount
1 SELECT $181.25
1 SELECT $4.50
1 SELECT $72.50
Permit Total Fees: $258.25
Operator: jmm Printed By: jmm Print Date: 6/13/2008
Project Number: 08002228 Inv: 1
Application
THIS IS NOT A PERMIT
Penalties will be assessed for commencing work without a permit
Date: 6/13/2008 Page 2 of 2
Notes:
Payment Summary:
Permit Type
Building Permit
Fee Amount Invoice Amount
$258.25 $258.25
$258.25 $258.25
Amount Paid
$0.00
Amount Owing
$258.25
$0.00 $258.25
Disclaimer:
Submittal of this application certifies the owner (or person(s) authorized by the owner) has both examined and finds the information
contained within to be true and correct, and agrees that all provisions of laws and/or regulations governing this type of work will be
complied with. Subsequent issuance of a permit shall not be construed to be a permit for, or an approval of, any violation of any of
the provisions of the code or of any other state or local laws or ordinances.
Signature:
Operator: jmm Printed By: jmm
Print Date: 6/13/2008
Spokane
Valley
Site Address: 1111 S NEWER CT
Parcel Number: 45234.5514
Zoning: MF -1
Fire District: FD 01
Project
Transmittal
City of Spokane Walley
Community Development
Department
11703 E. Sprague Ave, Suite B3
Spokane Valley, WA 99206
Phone: 509.688.0036
New project
Previouspre-app meeting ❑
Plan recisions
Transmittal Date:
Thursday, June 12, 2008
Water District: MODERN
Project Number: 08002228
Applicant:
e-mail:
Contact:
e-mail:
FLORIANOVICH, ALEXEY
14121 E 23RD AVE
SPOKANE VALLEY WA 99037
(509) 768-0273
FLORIANOVICH, ALEXEY
14121 E 23RD AVE
SPOKANE VALLEY WA 99037
(509) 768-0273
Contractor: AF CONSTRUCTION LLC
14121 E 23RD AVE
SPOKANE VALLEY WA 99037
(509) 926-1456
Owner: THOMPSON, GINA R
1111 S NEWER CT
SPOKANE VALLEY, WA 99037
e-mail:
Occupant:
e-mail:
Arch / Engineer:
e-mail:
Project
Description:
NI
JS A f amu. (Mi—r
.
Building
Landuse
Engineer
Utilities
Health
Fire Dist
Assessor
APPLICATIO
CONSTRUCTION PLAN
c
TD
Please send all plan review and project comments via e-mail to the
highlighted individuals.
SpQkane"
Valley
For City Use Only
PLUS Project Number R-zz7.8
Project Address ////S /iztd'- t
11703 E Sprague Ave Suite B-3 • Spokane Valley WA 99206 -
509.688.0036 • Fa*: 509.688.00374 permitcenter@spokanevalley.org
1
As part of our on-going commitment to customer service during the review process of your project
application, we are providing you with a TARGET DATE for the initial technical application review. If for
any reason we cannot meet this date, we will contact you with a revised target date.
Your application review TARGET DATE is U
The TARGET DATE is the date 'we estimate your project application will have had its initial technical
review. It is not the date for approval or permit issuance.
Tips for a Smoother Project Application Review
i Submit complete, accurate plans and documents.
Extra time may be required for re -submittals as project application reviewers work on multiple applications and it
may be several darns hefare they can look at roar new or revised information. -
Designate a specific contact person to communicate with the City.
11'hile the person' designated as the applicant's contact person with the City can he changed, one individual with the
expertise for dealing with reviewer comments would be the best choice for the entire review process.
i Call staff regarding the status of your project only after the target date shown at the'top'of the page.-
Although you should be contacted on or by the target date, please fee/ free to contact as if you haven't heard Irom ,us
by your target date. Staff mdv contact you hefbre the target date if time initial review is complete. By foljowing this
procedure. you will save time and allow the reviewers to complete the work more expeditiously.
Steps in the Permit Process
1. Counter Complete. Your application has been accepted as counter complete. This- means all of the required
documents, as indicated on your Pre -Application Checklist have been submitted or have been approved.' for deferred
submittal. This does not prevent technical staff from requesting' additional information,as a result of their technienEreview.
2. Quality Check. The next step in the process is a quality check to make sure that the application k reviewable and free
from substantive flaws that would prevent technical staff from completing -the technical review once it is started. When
this step is complete, your application will be routed to the appropriate staff and,remain in their review queue until it,
comes up for review.
3. Technical Compliance. Once an application is administratively complete. it is routed to technical staff for compliance
review. Depending on the type of project, technical staff may include, multiple reviewers. You should be contacted by
phone, fax, email, or mail by your TARGET DATE once the initial technical compliance review is complete.
4. Permit Issuance. When the technical compliance review of the application is complete, including any subsequent re-'
submittals, each reviewer will approve their section of the application and route it to the Permit Center. When all sections
of the application are received, a Permit Specialist will process the application and contact the person specified on your
application for permit pick-up. Information regarding fees and pre -construction meetings'(if required) will be provided by
the Permit Specialist at that time.
WHITE—APPLICANT PINK—BUILDING FILE
REV 9/07
Spokane
Val ley
Community Development
Permit Center
11707 E Sprague Ave, Suite 1Q6
Spokane Valley, WA 99206 RECEIVED BY
(509)688-0036 FAX: (50* -(j03'SPOKANE VALLEY
www. spokaneva 11ev.crg.com
Reroof Construction
Permit Application
JUN 12 20011
P MIT CENTER
PERNIIT NUMBER:
7...7
PERMIT FEE:
❑ Commercial
54 Residential
SITE ADDRESS 1/ 1 3 •
ASSESSORS PARCEL NO:
C-1 S//0 a HQ £ J/Q)
LEGAL DESCRIPTION:
_Contact Person
Name:
Phone:
Describe the scope of work in detail:
, " `Fig 7: 5a•.� r` � ` '+ p'' i
Name: e i Yi t 0 . `T(.917)f7i1
Address: oa 0 S' L-' e s4- I cI
a
�r/-n,).
City: SPO L i PE Zip: q q C 3 7
I Phone: 00(0j if -S353'ax:
_Contact Person
Name:
Phone:
Describe the scope of work in detail:
, " `Fig 7: 5a•.� r` � ` '+ p'' i
Name: 4 fealty % _ rL- fr / k )Wt'/GB7
Address: /Y/pS / �, -3 79 CiE
City: 14 hQ c% (e Zip: 9? 0.3 7
Phone:5 Of 7bd' --C' 27j Fax:
Lic No: A 9'JL, Exp. Date: /.2 / V. OS
City Business Lic No:
❑ Tear off D Overlay
-f - r lam "'` a 7-E h -Le !� r� ; �i�✓ toe
i
t -a i- - '•4' / L<< c a. i d e (e 611-4
Cost of project
DISCLAIMER
The permitee verifies, acknowledges and agrees by their signature that: 1) If this permit is for construction of or on a
dwelling, the dwelling is/will be served by potable water. 2) Ownership of this City of Spokane Valley Permit inure to the
property owner. 3) The signatory is the property owner or has permission to represent the property owner in this
transaction. 4) All construction is to be done in full compliance with the City of Spokane Valley Development Code.
Referenced codes are available for review at the City of Spokane Valley Permit Center. 5) This City of Spokane Valley
Permit is not a permit or approval for any violation of federal, state or local laws, codes or ordinances. 6) Plans or
additional information may be required to be submitted, and subsequently approved before this application can be
processed.
Ownership of resulting development rights granted by any issued permit inure to the property owner.
Signature 461-- 1-L 1-1-
Date
/( -
L.
Method of Payment: (Faxed permit applications will only be accepted with major bankcard)
II
Cash
Bankcard #:
❑ Check ❑ Mastercard
❑ VISA n Other
Expires: VIN#:
Authorized Signature:
REVISED 8/232005
WASHINGTON STATE ENERGY CODE
TABLE 6-2
PRESCRIPTIVE REQUIREMENT S°'1 FOR GROUP R OCCUPANCY
CLIMATE ZONE 2
* Reference Case
0. Nominal R -values are for wood frame assemblies only or assemblies built in accordance with Section 601.1.
1. Minimum requirements for each option listed. For example, if a proposed design has a glazing ratio to the conditioned floor area
of 13%, it shall comply with all of the requirements of the 15% glazing option (or higher). Proposed designs which cannot meet the
specific requirements of a listed option above may calculate compliance by Chapters 4 or 5 of this Code.
2. Requirement applies to all ceilings except single rafter or joist vaulted ceilings complying with note 3. 'Adv' denotes Advanced
Framed Ceiling.
3. Requirement applicable only to single rafter or joist vaulted ceilings where both (a) the distance between the top of the ceiling
and the underside of the roof sheathing is less than 12 inches and (b) there is a minimum 1 -inch vented airspace above the insulation.
Other single rafter or joist vaulted ceilings shall comply with the "ceiling" requirements. This option is limited to 500 square feet of
ceiling area for any one dwelling unit.
4. Below grade walls shall be insulated either on the exterior to a minimum level of R-12, or on the interior to the same level as
walls above grade. Exterior insulation installed on below grade walls shall be a water resistant material, manufactured for its
intended use, and installed according to the manufacturer's specifications. See Section 602.2.
5. Floors over crawl spaces or exposed to ambient air conditions.
6. Required slab perimeter insulation shall be a water resistant material, manufactured for its intended use, and installed according
to manufacturer's specifications. See Section 602.4.
7. Int. denotes standard framing 16 inches on center with headers insulated with a minimum of R-10 insulation.
8. This wall insulation requirement denotes R-19 wall cavity insulation plus R-5 foam sheathing.
9. Doors, including all fire doors, shall be assigned default U -factors from Table 10-6C.
10. Where a maximum glazing area is listed, the total glazing area (combined vertical plus overhead) as a percent of gross
conditioned floor area shall be less than or equal to that value. Overhead glazing with U -factor of U=0.40 or less is not included in
glazing area limitations.
11. Overhead glazing shall have U -factors determined in accordance with NFRC 100 or as specified in Section 502.1.5.
12. Log and solid timber walls with a minimum average thickness of 3.5" are exempt from this insulation requirement.
Effective July 1, 2007
34
z
Ceiling
Vaulted3
Ceiling
Wa1112Wall.
Above
Grade
nt°
Below
Grade
ext:
Below
Grade
Floor
Slabb
on
Grade
Glazing
Glazin
U -Factor
9
Option
Area'°:
of Floor
Vertical
Overheadtit
Door
U -Factor
I.
12%
0.35
0.58
0.20
R-38
R-30
R-21
int'
R-21
R-12
R-30
R-10
II.*
15%
0.35
0.58
0.20
R-38
R-30
R-19 +
R-58
R-21
R -l2
R-30
R-10
111.
17%
0.32
0.58
0.20
R-38
R-30
R-19 +
R-58
R -2I
R-12
R-30
R-10
IV.
25%
Group R-1
and R-2
Occupancies
Only
0.35
0.58
0.20
R-38 /
U=0.031
R-30 /
U=0.034
R-21
int' /
U=0.054
R-15
R-12
R-30 /
U=0.029
R-10 /
F=0.54
V.
Unlimited
Group R-3
and R-4
Occupancies
Only
0.35
0.58
0.20
R-38
R-30
R-19+
R-58
R-21
R-12
R-30
R-10
VI.
Unlimited
Group R-3
and R-4
Occupancies
Only
0.30
0.58
0.20
R-49 or
R-38 Adv
R-38
R-21
int'
R-21
R-12
R-30
R-10
X.11.
Unlimited
Group R-1
and R-2
Occupancies
Only
0.32
0.58
0.20
R-38 /
U3.031
R-30 /
U=0.034
R-21
int' /
U=0.054
R-15
R-12
R-30 /
U=0.029
R-10 /
F=0.54
* Reference Case
0. Nominal R -values are for wood frame assemblies only or assemblies built in accordance with Section 601.1.
1. Minimum requirements for each option listed. For example, if a proposed design has a glazing ratio to the conditioned floor area
of 13%, it shall comply with all of the requirements of the 15% glazing option (or higher). Proposed designs which cannot meet the
specific requirements of a listed option above may calculate compliance by Chapters 4 or 5 of this Code.
2. Requirement applies to all ceilings except single rafter or joist vaulted ceilings complying with note 3. 'Adv' denotes Advanced
Framed Ceiling.
3. Requirement applicable only to single rafter or joist vaulted ceilings where both (a) the distance between the top of the ceiling
and the underside of the roof sheathing is less than 12 inches and (b) there is a minimum 1 -inch vented airspace above the insulation.
Other single rafter or joist vaulted ceilings shall comply with the "ceiling" requirements. This option is limited to 500 square feet of
ceiling area for any one dwelling unit.
4. Below grade walls shall be insulated either on the exterior to a minimum level of R-12, or on the interior to the same level as
walls above grade. Exterior insulation installed on below grade walls shall be a water resistant material, manufactured for its
intended use, and installed according to the manufacturer's specifications. See Section 602.2.
5. Floors over crawl spaces or exposed to ambient air conditions.
6. Required slab perimeter insulation shall be a water resistant material, manufactured for its intended use, and installed according
to manufacturer's specifications. See Section 602.4.
7. Int. denotes standard framing 16 inches on center with headers insulated with a minimum of R-10 insulation.
8. This wall insulation requirement denotes R-19 wall cavity insulation plus R-5 foam sheathing.
9. Doors, including all fire doors, shall be assigned default U -factors from Table 10-6C.
10. Where a maximum glazing area is listed, the total glazing area (combined vertical plus overhead) as a percent of gross
conditioned floor area shall be less than or equal to that value. Overhead glazing with U -factor of U=0.40 or less is not included in
glazing area limitations.
11. Overhead glazing shall have U -factors determined in accordance with NFRC 100 or as specified in Section 502.1.5.
12. Log and solid timber walls with a minimum average thickness of 3.5" are exempt from this insulation requirement.
Effective July 1, 2007
34
2006 1KC
Ten Things You Must Know!!
1 z.v 5F
Seo lux7.`
1. R105.2 "Work Exempt From Permit" — Spokane County will maintain the 200
sq/ft threshold for one-story detached accessory structures used as tool and storage
sheds, or similar uses.
2. Table R301.5 "Live Loads" — Attic storage is clarified in the footnotes of this table.
An example: If two or more adjacent trusses with the same web configuration
contain a rectangle 42 inches or greater in height by 24 inches or greater in width,
located within the plane of the truss, a 20 psf liveloa.dmust be applied to the design
of the bottom chord components affected._
3. R319.L5 "Exposed Glued -laminated Timbers" — Those portions of glu-lam
timbers that form structural suppotLof buildings/structures and are exposed to the
weather, and not protected by a roof, cave, or similar covering shall be pressure
treated, or naturally durable wood.
4. WAC AMENDMENT R327 "Protection Against Radon" — State adoption of
IRC Appendix F for mitigation measures applicable for buildings constructed in
"High Radon Potential Counties" (Spokane county). Appendix F, Section AF101.1
(WAC Amendment) no longer permits un -vented (conditioned) crawl spaces.
Appendix F further requires passive radon vents to be installed in vented crawl
spaces. WAC Amends R408.2, permitting 1:300 sq/ft ratios for ventilating crawl
spaces.
5. R406.1 "Foundation Damp -proofing" — Language change removes "habitable or
usable spaces", and replaces with "foundation walls that retain earth and enclose
interior spaces and floors below grade..." effectively requiring damp -proofing of
crawl space foundation walls. R4-06.2 similar for water -proofing.
6. R613.2'Window Sills" — New section requires protection similar to guardrails (4"
dia. sphere) for operable portions of windows less than 24 inches above the finished
floor, and greater than 72 inches above the adjacent exterior grade or surface below.
7. R702.4.2 Tile Backer Board — Requires cement, fiber -cement, or glass mat gypsum
backers for tile installation in tub and shower areas and wall panels in shower areas.
8. R703.2 and Table R703.4 "Water -resistive Barrier" — Felt, or other approved
barriers (house wrap) are now required over all exterior wall studs or sheathing, and
there is no longer an exception for not requiring such felt/barriers under panel
sidings with shiplap joints.
9. R703.8 "Flashing" — The provisions for self -flashing windows (use if the window's
mounting flange) has been eliminated. Approved corrosion -resistive flashings must
be applied shingle fashion at all door/window openings. R61 3.1 requires window
manufacturers to provide installation/flashing instructions for each window.
10. Washington State Energy Code Section 505.3 "Outdoor Lighting" —
Luminaries providing outdoor lighting and permanently to residential buildings must
be high efficiency (compact fluorescent) bulbs with pin style base. Exception allows
incandescent fixtures controlled by motion sensors with integral photo sensors.
EMERGENCY LOAM Ri01MREMEMTI
FROM l ►RM1100MS
t) NET CLEAR OPEN: 5.7 SOMME FEET
GRADE FLOOR MEMONII 44') 5.0 SOMME FEET
2) NET CLEAR OPENING HEIGHT 24 INCIES
NCHES
41 MAX FIN SHED SILL IOIT 44T CEAR OPENING WIDTH 20'ABOVE FLOOR
E ME RGE NC v ESCAPE II NUM OPENING SHALL BE
"t ;SATION tit FROM imEINCE OF THE ROOM WITHOUT
HI 'ISE .n *t VS OR TOOLS
WHEN INTERIOR ALTERATIONS, REPAIRS OR ADDITIONS
REQUIRING A PERMIT OCCUR, OR WHEN ONE OR MORE
SLEEPING ROOMS ARE ADDED OR CREATED IN EXISTING
DWELLINGS, THE DWELLING UNIT SHALL BE PROVIDED
WITH SMOKE ALARMS LOCATED AS REQUIRED FOR NEW
DWELLINGS.
SMOKE ALARMS SHALL BE INTERCON-
NECTED AND HARD WIRED IN SUCH A
MANNER THAT THE ACTIVATION OF ONE
ALARM WILL ACTIVATE ALL ALARMS.
(BEDROOMS, AREAS APPROACHING
BEDROOMS, VAULTED CEILING
WITH RISE OF 24' & ON EACH FLOOR)
11;!.# EXHAV1314
50:,
& 1Atli 4trij
Ta ---}C-relktoA-.
Washington State Ventilation
and Indoor Air Quality Code
requires a source specific and
0 whole house ventilation system
WINDOW WELL:
Min. 9 sq. ft. horizontal area.
Min. 3 ft. horizontal projection and width.
Max. 44 in. vertical depth without a ladder
STAIRWAYS: Minimum width 36 M. with min. tread
run of 10 in., max. rise of 7 3/4 in. & nosing of 3/4-1 1/4 in.
Min. 6 ft. 8 in. headroom. Enclosed usable space under
stairways requires 1 hour fire protection of in. GWB
HANDRAILS: Height of 34 — 38 inches when required by four or
more risers shall be continuous the full length of stairs with the
ends returned or rounded. LANDINGS: Required min. width of 36
in. or width of stairway and 36 in. travel distance
ec rt a. IQ /whip 3631-7
.g7 /Ve�icz e-
92 4
t2�
itb 6
(77
• z
yl Or) 114p
�Ateu2 £111aJ1ue
R03 OW33921,11 • :WI
Egress: wind
._ 5.7 sq. ;tt.;.- 44"
H r
// 99-3�1i�
S'd 5 .-t7& i 7 oft/ a "oar/ Tg
/Z:?
1 �l
Ma 45 o (2_web Ai
"V0 44 Gro es s 4) 41)
•
(/(7
1
5-`3'
c_.2,1tAsu STc oiJ
C_mN>Jd'A-T,5-
pl.4-*4
4L 1t
PROVIDE DIAGRAMS AND
ENGINEERING LAYOUTS FOR
ROOF TRUSSES, BEAMS AND
FLOOR SYSTEMS PRIOR TO FRAMING
INSPECTIONS
CITY COPY
THIS BUILDING SUBJECT
TO FIELD,INS!EGT ON;COF1RRECT10NS
RFOR COD EVIEWED
DVALLLEY BU DINGG .IVIS ONE
6 /