Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
2006, 03-27 Permit App: 06000914 Residence
Project Number: 06000914 Inv: 1 Application THIS IS NOT A PERMIT Penalties will be assessed for commencing work without a permit Date: 3/27/2006 Page 1 of 3 Project Information: Permit Use: NEW RESIDENCE W/ATTACHED GARAGE -GAS Contact: VIKING CONSTRUCTION Address: 2605 W HAYDEN AVE C - S - Z: HAYDEN, ID 83835 Setbacks: Front 33 Left: 7 Right: 5 Rear: 44 Phone: (208) 762-9106 Group Name: Site Information: Project Name: Plat Key: Name: Range Parcel Number: 46353.0502 Block: 4 SiteAddress: 14312 E OLYMPIC AVE Location:: CSV Zoning: UR -3.5 Water District: Area: 11,248 Sq Ft Urban Residential 3.5 District: East Lot: 9 Owner: Name: VIKING CONSTRUCTION Address: 2605 W HAYDEN AVE HAYDEN, ID 83835 Hold: ❑ Width: 90 Depth: 126 Right Of Way (ft): 38 Nbr of Bldgs: 1 Nbr of Dwellings: 1 Review Information: Review Building Plan Review Driveway/Approach Released By: Originally Released: 3/24/2006 By: TMELBOU Released By: Originally Released: 3/17/2006 By: cjjanssen Landuse/Zoning/HE Conditions Released By: Sewer Review Permits: Operator: CJJ Originally Released: 3/17/2006 By: cjjanssen Released By: Originally Released: 3/27/2006 By: amblake Printed By: AMB Print Date: 3/27/2006 Project Number: 06000914 Inv: 1 Application THIS IS NOT A PERMIT Penalties will be assessed for commencing work without a permit Date: 3/27/2006 Page 2 of 3 Contractor: VIKING CONSTRUCTION Address: 2605 W. HAYDEN AVE HAYDEN, ID 83835 Item Description APPROACH -CONST IN ROW Contractor: VIKING CONSTRUCTION Address: 2605 W. HAYDEN AVE HAYDEN, ID 83835 Description Grp Type 1&2 FAMILY R-3 VB DECK OPEN R-3 VB GARAGE U-1 VB Item Description RESIDENTIAL PERMIT FEE WSBC SURCHARGE SF PLNS RVW < 7999 SQ FT Notes Contractor: AIR DESIGN INC Address: 1807 E FRANCIS AVE SPOKANE, WA 99207 Item Description GAS WATER HEATER GAS APPLIANCE<=100,000BTU GAS PIPING VENTILATING FANS RANGE GAS LOG OR GAS INSERT HOOD -TYPE II Approach Firm: VIKING CONSTRUCTION Phone: (208) 762-9106 Units Unit Desc Fee Amount 1 NUMBER OF $50.00 Permit Total Fees: $50.00 Building Permit Firm: VIKING CONSTRUCTION Phone: (208) 762-9106 This Application: Total Project: Sq Ft Valuation Sq Ft Valuation 1,799 $155,379.63 1,799 $155,379.63 96 $1,440.00 96 $1,440.00 780 $14,820.00 780 $14,820.00 Totals: 2,675 $171,639.63 2,675 $171,639.63 Units 1 1 1 Unit Desc SELECT SELECT SELECT Permit Total Fees: Mechanical Permit Units 1 1 4 3 1 1 1 Operator: CJJ Printed By: AMB Fee Amount $1,396.95 $4.50 $558.78 $1,960.23 Firm: AIR DESIGN INC Phone: (509) 487-4328 Unit Desc NUMBER OF NUMBER OF # OF UNITS NUMBER OF NUMBER OF NUMBER OF NUMBER OF Permit Total Fees: Print Date: Fee Amount $10.00 $12.00 $4.00 $30.00 $10.00 $10.00 $10.00 $86.00 3/27/2006 Project Number: 06000914 Inv: 1 Notes:,,µ Application THIS IS NOT A PERMIT Penalties will be assessed for commencing work without a permit Date: 3/27/2006 Page 3 of 3 Payment Summary:... Permit Type Fee Amount Invoice Amount Amount Paid Amount Owing Approach $50.00 $50.00 $0.00 $50.00 Building Permit $1,960.23 $1,960.23 $0.00 $1,960.23 Mechanical Permit $86.00 $86.00 $0.00 $86.00 $2,096.23 $2,096.23 $0.00 $2,096.23 Disclaimer: Submittal of this application certifies the owner (or person(s) authorized by the owner) has both examined and finds the information contained within to be true and correct, and agrees that all provisions of laws and/or regulations governing this type of work will be complied with. Subsequent issuance of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the code or of any other state or local laws or ordinances. Signature: Operator: CJJ Printed By: AMB Print Date: 3/27/2006 Project Number: 06000914 Inv: 1 Application THIS IS NOT A PERMIT Penalties will be assessed for commencing work without a permit Date: 03/17/2006 Page 1 of 2 Project Information:,.. Permit Use: NEW RESIDENCE W/ATTACHED GARAGE -GAS Contact: VIKING CONSTRUCTION Address: 2605 W HAYDEN AVE C - S - Z: HAYDEN, ID 83835 Phone: (208) 762-9106 Group Name: Site Information: Project Name: Plat Key: Setbacks: Front 33 Left: 7 Right: 5 Rear: 44 Name: Range Parcel Number: 46353.0502 Block: 4 SiteAddress: 14312 E OLYMPIC AVE Location:: CSV Zoning: UR -3.5 Water District: Area: 11,248 Sq Ft Urban Residential 3.5 District: East Lot: 9 Owner: Name: VIKING CONSTRUCTION Address: 2605 W HAYDEN AVE HAYDEN, ID 83835 Hold: ❑ Width: 90 Depth: 126 Right Of Way (ft): 38 Nbr of Bldgs: 1 Nbr of Dwellings: 1 Review Information:. • Review Building Plan Review Driveway/Approach Released By: V i A T -AA Released By: Originally Released: 03/17/2006 By: cjjanssen Landuse/Zoning/HE Conditions Released By: Sewer Review Permits: Operator: CJJ Originally Released: 03/17/2006 By: cjjanssen Printed By: CJJ Released By: Print Date: 03/17/2006 Project Number: 06000914 Inv: 1 Application THIS IS NOT A PERMIT Penalties will be assessed for commencing work without a permit Date: 03/17/2006 Page 2 of 2 Contractor: VIKING CONSTRUCTION Address: 2605 W. HAYDEN AVE HAYDEN, ID 83835 Contractor: VIKING CONSTRUCTION Address: 2605 W. HAYDEN AVE HAYDEN, ID 83835 Contractor: AIR DESIGN INC Address: 1807 E FRANCIS AVE SPOKANE, WA 99207 Notes: 132.91VMMOMMUMMENROMMOMSEM Approach Firm: VIKING CONSTRUCTION Phone: (208) 762-9106 Building Permit Firm: VIKING CONSTRUCTION Phone: (208) 762-9106 Mechanical Permit Payment Summary: ora47 Disclaimer: Submittal of this application certifies the owner (or person(s) authorized by the owner) has both examined and finds the information contained within to be true and correct, and agrees that all provisions of laws and/or regulations governing this type of work will be complied with. Subsequent issuance of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the code or of any other state or local laws or ordinances. Firm: AIR DESIGN INC Phone: (509) 487-4328 Signature: Operator: CJJ Printed By: CJJ Print Date: 03/17/2006 03/27/200E 02:35 2087E24507 P • - VIKING CONST F()=t.1NE CS(=)i. ,tirry y ; :\.[ EN'l ().F �� u i� rN c: � .�. _ 1 t _" :NN 1 IN(i 11126r, r l:'tcOADWAY \VrENCI: • Si'11I` _NE \\i\ 261)-01150 FADE 04/06 Site (nfonittttiGn Site Address: 14312 E OLYMPIC .AVE Pnrcel ,Number: 46353.0502P Subdivision: RANGE Block: Lot: Zoning: LOR Low Density Residential Owner: VIKING CONSTRUCTION Address: 2605 W HAYDEN AVE HAYDEN, ID 83835 Building Inspector: Dan Howard Wnter Dist: L Project Information Project Number: 06001598 Inv: I Issue Date: 3%23/2006 Permit Use: NEW SEWER CONNECT, HUNTER'S RUN Applicant: VIKING CONSTRUCTION 2505 W HAYDEN AVE HAYDEN. ID 83835 Thane: (208) 762-9106 Contact: VIKING CONSTRUCTION 2(05 W HAYDEN AVE HAYDEN, ID 53835 Phone: (208) 762-9106 Setbacks - Front: Left: Right: Grout Name: Project Nstnie: Permits Seiner Connection Permit Contractor: VIKING CONSTRUCTION Lice �e n: VIKINCi9zs8O.l SEWER CONNECTION 1 15E5..00 PROCESSING FEE Total Perini, re.: 5100.00 FOR SEWER INSPECTIONS CALL THE UTILITIES DEPT AT (509) 477-3604 FROM 6:30-5:00 MONDAY -FRIDAY PRIOR TO COVER. ONE WORKING DAY NOTICE REQUIRED. PERMIT ALLOWS FOR A 30 -MINUTE INSPECTION. ADDITIONAL INSPECTION FEES APPLY AFTER 30 MINUTES. THE INSTALLER IS RESPONSIBLE TO INSURE ALL WASTEWATER DRAINS ARE CONNECTED TO THE SEWER AND MAY BE REQUIRED TO PERFORM TESTS FOR VERIFICATION. INSTALLER IS TO FIELD LOCATE AND CONFTRN1 THE ELEVATION AND POSITION OF SEWER STUB PRIOR TO ANY OTHER EXCAVATION. SEWER STUBS ARE TO BE CHECKED PRIOR TO CONNECTION TO ENSURE, THAT TI FEY HAVE. ACCEPTABLE GRADE AND ARE, CLEAR AND UNOBSTRUCTED TO THE MAIN, SEWER LINES SHOULD BE CONSTRUCTED TO ALLOW FOR GRAVITY FLAW FROM THE LOWEST LEVEL OF THE STRUCTURE. TIIE INSTALLER AND THIS PERMIT MUST BE PRESENT AT THE JOB SITE AT THE SCHEDULED INSPECTION TIME. GOTH ST.\TE LAW RCW 19.122 AND COUNTY CODE REQUIRES THE INSTALLER TO GIVE NOTICE OF EXCAVATION TO OWNERS OF UNDERGROUND FACILITIES. CALL, 1-800-42A-5555 BEFORE YOU DIG --AT LEAST 2 WORKING DAYS IN ADVANCE. SPOKANE COUNTY CODE REQUIRES THE 1NSTALLER COMPLY WITH ALL REQUIREMENTS, OF THE WA. STATE DEPT OF LABOR & iNDUSTr1ES, INCLUDING THOSE RELATED TO TRENCH SAFETY. 1 $15.00 Pa;•rncnt 'Siimniary Total Feces AolottntPaid AntountOW'1nu 5100.00 5100.00 50.00 Tran Date 3/23/2006 Prnc.ssc-d fly: Hansen, Tom Printed ll}: WENDEL, GLORIA Paye 1 of I MAR 27 2026 28:0O Receipt _5 Payment Amt. 1290 5100.00 PERNIIT 2087824507 FAGE.04 ) S„nor SI e Valley Community Development Permit Center 11707 E Sprague Ave, Suite 106 Spokane Valley, V 9 rc M E (509)688-0036 F.^ '009)688-20037 7.s7,7v.spokanevalle n rnm r- MA,, 17 2006 Residential Construction Permit Application PERMIT NUMBER: (11 PERMIT FEE: 11ns,*r-l" etion o Accessory Bldg o Addition/Remodel o Deck o Other: SITE ADDRESS 143\,4-ptc �e ASSEESSSORS PARCEL NO: u (93 )3 , L5 C�� LEGAL DESCRIPTION:UA-- '1 bk_a Building o`Wner , Name: `I`IV �,i1CA Address:.', S Lu , 1 i ) OU City: `lea i VSjA Zip: ?)J�?,, Phone:()( r)(.0. -c-4 Olt, Fax: ,7:4L., ----10j--(--1`31:1 Contact Person Name: Phone: Describe the scope of work in detail: Contractor._ Name: Address: City: Zip: Phone: Fax: Lic No: \(\1�..w, ;(cIcei? ,) i } Exp. Date: City Business Lic No: Cost of Project: **************The following MUST be complete: (write N/A if not applicable)********************** HEIiH� JO �g „ DIMENSIONS:/7Xqe- = 6,» # OF STORIES: MAIN FLOOR TO SQ. V( L s FTG: ! / f FINISHED BASE NT SQ. FTG: jj/i9 # OF BEDROOMS: 3 DISCLAIMER 2Nu FLOOR SQ. FTG: A/A GARAGE SQ. FTG: nK 7?3'OSC? F% CONSTRUCTION TYPE: UNFIN BASEMENT SQ. FTG: /V74 DECK/CO PATIO S .Z.TG: HEAT SOURCE: ��jj TOTAL HABITABLE SPACE: / 9 9 SQ.F7 . IMPERVIOUS SURFACE AREA: />S -2 -SO �r 30% SLOPES ON PROPERTY: Now' SEWER OR SEPTIC? The permitee verifies, acknowledges and agrees by their signature that: 1) If this permit is for construction of or on a dwelling, the dwelling is/will be served by potable water. 2) Ownership of this City of Spokane Valley Permit inure to the property owner. 3) The signatory is the property owner or has permission to represent the property owner in this transaction. 4) All construction is to be done in full compliance with the City of Spokane Valley Development Code. Referenced codes are available for review at the City•of Spokane Valley Permit Center. 5) This City of Spokane Valley Permit is not a permit or approval for any violation of federal, state or local laws, codes or ordinances. 6) Plans or additional information may be required to be submitted, and subsequently approved before this application can be processed. Signature L , �k ,L Date L Method of Payment: (Faxed permit applications will onl • . accepted with major bankcard) ❑ Cash E Check ❑ Mastercard ❑ VISA ❑ Other Bankcard #: Expires: VIN#: Authorized Signature: REVISED 8/25/2005 Sj�UTne 4010°1/alley 11707 E Sprague Ave Suite 106 ♦ Spokane Valley WA 99206 509.921.1000 i Fax: 509.921.1008 i cityhait®spokanevaiiey.org 4 Residential Plan Submittal Minimums ❑ Completed Building & Mechanical application with: Accurate address, Parcel Number and/or Legal Description, description of work, owner and contractor information, signature, and date. Two sets of plans including Site Plan, elevations, floor plans, foundation plans With details, roof plan, framing plans & details. Show the height of any proposed buildings or accessory structures. Cg Floor plan for each floor: Dimension to scale (minimum 1/8") and label each Room (including sq. footage of house and garage on plans) Show each level of existing house and square footage of any additions. g All braced wall panel types: show locations and details of installation, including engineered design. ,I Egress windows: Provide at least one window or exterior door approved for Emergency escape or rescue from a basement and in every room for sleeping. Smoke detector locations ,e( 22" X 30" attic access location 18" X 24" crawl space access: One-hour separation detail: between house and garage Floor framing details: Joist type, size, spacing and installation details .. Roof framing plan and details Furnace and hot water heater location. All header locations: type, size, and connections Foundation plan Insulation information Oft t_tii.alle %al ..om: unity' Development Permit C enter 11707 E Sprague Ave. Suite 106 Spokane Valley. `‘.\' A 99206 Approach Permit Application ion i I PER \,ET 'NT :NEER PERMIT FEE: PROJECT ADDRESS Lt -k30-- CXyrC ) START DATE A l ICU ATED COMTLETIION DATE Building Owner: C}`wner. Contractor: / Name: Y 1Vt 1X'c, Name: C� i ^.Q Address: Address: , c ;5 kx; . k ,_ •, L n N -e_ . City State: Zip:,,.) City: State: Zip: Phone: ,)0(e,---- q 1 f) u Fax: ;cyr,.= 1Ly..)..- USW Phone: Fax: Contact Person Contractor Lic No:Exp Y i K I t�C ICT Date: Name: City Business Lic. No: Phone: j?.,r--1(e-y -Gtl )c' , PROJECT DESCRIPTION (Provide site sketch) Residential Driveway Existing Curb & Gutter Culvert Installation Other Conditions Commercial/Industrial Driveway Rural Road Section Sidewalk Repair/Construction Bond/Insurance certification must be on file with the city. DISCLAIMER The permittee verifies, acknowledges and agrees by their signatures that: 1) If this permit is for construction of or on a dwelling, the dwelling is/will be served by potable water. 2) Ownership of this City of Spokane Valley Permit inure to the property owner. 3) The signatory is the property owner or has permission to represent the property owner in this transaction. 4) All construction is to be done in full compliance with the City of Spokane Valley Development Code. Referenced codes are available for review at the City of Spokane Valley Permit Center. 5) This City of Spokane Valley Pernut is not a permit or approval for any violation of federal, state or local laws, codes or ordinances. 6) Plans or additional .information may be required to be submitted, and subsequently approved before this application can be processed. Signature Method of Paymen:: ❑ Cash ❑ Check Bankcard r. Authorized Signature: REVSED 3!910€ Date 31 OP ❑ Mastercard ❑ VISA Expires: Spokan' Community Development Permit Center 11707 E Sprague .Ave, Suite 106 Spokane Valley, \VA 99206 (509)688-0036 FAX: (509)688-0037 www.spokanevallev.ore.com Mechanical Permit Applicationi�o Commercial SITE ADDRESS 'I-i�Z\ ri lal� rri 2 Lc- Ove-- PERMIT NUMBER: PERMIT FEE: d Residential Building owner Name: \ t j,' c )"1- t , t„ ,.VI't'i c-4- i i t \ III, . - -C^ Vin( _, ` ,• i(r) Phone: r-1(' ' Fax (,0_ ii .f1:-..-:.-lic I' Address: L-(y.i :K 'q---) i - t`.>d t1; )'1 k:'? City t is t !t,!i. \ State ---C1--,' Zip '-''•')- ,`. Contractor Name: 0,its -10,-,:...r,,1,--\ Phone: Fax: Address: City State Zip License No: City Business License No: Contact Name: Phone: • DESCRIPTION OF WORK it OF UNITS COST TOTAL AMOUNT FUEL BURNING APPLIANCE Equal to or less than 100,000 X $12.00 2 FUEL BURNING APPLIANCE UNLISTED APPLIANCE (Additional Fee) More than 100,000 Equal to or less than 400.000 4 UNLISTED APPLIANCE (Additional Fee) 5 USED APPLIANCE SEC min. AFUE rating 6 USED APPLIANCE (WSEC min. AFUE rating) 7 BOILER/REFRIGERATION 8 BOILER/REFRIGERATION 9 BOILER/REFRIGERATION 10 11 12 BOILER/REFRIGERATION BOILER/REFRIGERATION More than 400,000 X $15.00 = $50.00 E. ual to or less than 400,000 More than 400,000 1 - 100M BTU $100.00 $50.00 X $100.00 GAS LOG, GAS INSERT, GAS FIREPLACE 101 - 500M BTU 501 - 1,000M BTU 1,001 - 1,750M BTU More than 1.750M BTU X X $12.00 $20.00 $25.00 $35.00 $60.00 $10.00 13 RANGE $10.00 14 DRYER X $10.00 = 15 FUEL BURNING WATER HEATER X $10.00 16 MISC. FUEL BURNING APPLIANCE X $10.00 17 GAS PIPING (each outlet) W X $1.00 18 DUCT SYSTEMS X $10.00 19 VENTILATING FANS X $10.00 2D AIR HANDLER (DOES NOT include ducting) Equal to or Tess than 10,000 CFM X $12.00 = 21 AIR HANDLER (DOES NOT include ducting) Greater than 10,000 CFM X $15.00 = 22 EVAPORATIVE COOLERS X $10.00 = 23 TYPE I HOOD X $50.00 24 TYPE II HOOD X $10.00 25 HEAT PUMP/AIR CONDITIONER 0-3 TON $12.00 26 AIR CONDITIONER 3-15 TON $20.00 27 AIR CONDITIONER 15-30 TON X $25.00 28 AIR CONDITIONER 30-50 TON $35.00 = 29 AIR CONDITIONER More than 50 TON X $60.00 30 LPG STORAGE TANK $10.00 31 WOOD OR PELLET STOVE/INSERT $10.00 32 WOOD STOVE - FREE STANDING $25.00 33 REPAIR & ADDITIONS X $15.00 = 34 VENTILATION SYSTEMS X $12.00 = 35 VENTILATION MECHANICAL EXHAUST $12.00 36 INCINERATOR - RESIDENCE 37 INCINERATOR - COMMERCIAL X X $19.00 522.00 = • METHOD OF PAYMENT: ❑CASH ❑ CHECK ❑ VISA ❑ MC CARD AUTHORIZED SIGNATURE: DATE: EXPIRES: SUBTOTAL PROCESSING FEE 1 $35.00 TOTAL PERMIT FEE DUE: REVISED E'26/05 SMIE P L r SCALE: 1"= 20'- 0" LOT 9 BLOCK 4 HUNTERS RUN • SPOKANE VALLEY, WASHINGTON 9'-11" This site plan is being submitted for the purpose of obtaining a building permit and is a true and correct represcntaion of the propsal. All known property lint/dimensions, curb lines, structures and casements have been identified. Also indicated arc wetlands, bodies of water, steep slopes or other critical areas. Signed: D.S. 3-(AR.?EC Date: 3-15-06 80' PROPERTY LINE 77'-0" 5'-0'' 30' BACK SETBACK 00 WATER UNDER GROUND PON'ER PROPERTY LING CONC. PATIO 9 in 2579 SQ. FT. TOTAL FOOT PRINT/ M 33' FRONT SETBACK. DRIVEWAY EXPOSED AGGREGATE COVERED FRONT PORCH & SIDEWALK 10' UTILITY 54 3 EASEMENT 13' PROPERTY EASEMENT SIDEWALK • 89.11' PROPERTY LINE SWALE 0 OLYMPIC AVM O M PLANNING DEPT. APPROVED BY: CROWN OF STREET 1 DATE: 3L l --7 L 6-1-/ (Id I (Cri'it//C (ZA 1=7 s Rev io uo IL. op ivratt holt 760-510-3820 p.2 2x6 TOF ELATE ,iOINT5 LAPFED MNI`1'UM 48" 4 FULL S'LI ACE !SLUED AND NAILED W;T✓-+ iOd e 6"o.c. WHILE GLUE WET —� GLUE OUTSIDE 2x6 TRIM STUD TO —� EDGE OF VERTICAL 2x12 AND MAIL - WITH 10o o 6"o.c. WHILE GLUE WET FULL SURFACE GLUE ALL VERTICAL 2x1215 TO LAPPED HEADER (WIT• -I BRUSH OR ROLLER) AND NAIL WITH IOd 9 4"o.c. E.W. WHILE GLUE LIrET VERTICAL FLAT 2x12 ( TYPICAL AT ENDS OF DOOR AND BETWEEN DOUBLE DOORS AND CONTINUOUS TO TOP PLATE) NOTCH HEADERS 4"+ THICK TO SNUG FIT VERTICAL 2x12 HEADER SIZED FOR =/ VERTICAL LOADS BY OTHERS BUT NOT LESS THAN 2x12 (B 1/4" DEEP) GLUE INSIDE 2x6 TRIM STUD TO EDGE OF VERTICAL FLAT 2x12 AND NAIL WITH IOa 9 6'o.c. WHILE GLUE WET (TYPICAL) FULL SURFACE GLUE SHEETING WITH NO .:0INTS 4' FROM CORNER SHEETING ,:OMIT LOCATE I-LEADER2x12 FILLERS FULL 4- TOP OF 1 SLIPPAGE GLUED OPENING - FILL / AND NAILED TO 450VE WITH 2x1 7JE.AL EP UJITL! ISc,l t3 STUDS 9 16 "o.c. / 6 "o.c. EW. WHILE / GLUE WET (NOT REQUIRED WHEN 4' - THICK NOTCHED HEADER FULLS THE 11'2" SPACE) x 4'-0' SIMPSON MSTA24 STRAP TIE -" OVER SHEETING w/(18)10d NAILS 3" HOLE CENTERED IN 2x12 OKAY --" ADD 2x6 STUDS A5 REQUIRED FOR HEADER SUPPORT INSTALL SIMPSON PAHD42 NO_D DOUN CONNECTED TO 2x12 OR ... OR INSTALL SIMPSON IDSA —, HOLDQtLN WITH %" EPDXIED A.B. GOOD FOR 3000" TENSION AND CONNECTED TO DBL INSIDE STUDS W'TI- (2) %4" DIA BOLTS (2)5/6" x 10" A.B.'S 9 6"'�- "4 HAIRPN or STIRRUP w/16" LEGS "% 6' \MIN HOOKED AROUND LIP ANCHOR OF PAHD42 and EXTEND INTO STEM 0-30 deg WALL and FOOTING IF STEM WALL 15 SHORTER THAN REBAR LEGS OUTSIDE VIEW INSIDE VIEW BOTTOM 8' PANEL — NOTCH NG OPTIONAL (STOP AT 2x6 HEAD TRIMMER) EXTERIOR SHEETING )" NOMINAL PLYWOOD OR 055 NAILED WITH 8d COMMON OR GALVANIZED BOX NAILS AT 6"o.c. AT ALL EDGES (ALL EDGES MUST BE BLOCKED) AND I2"a.c. AT ALL OTHER SUPPORTS FRAMING LUMBER 2x6 SW WALL MINIMUM DFL No. 2 OR BETTER GLUE MUST BE IMPERVIOUS TO SERVICE CONDITIONS RELATED TO MOISTURE AND TEMPERATURE AND PROVIDE SHEAR STRESS OF 50"42 THIS DETAIL ONLY PER 2000/2003 IB.CJI.R C. (EXPIRES THEREAFTER) 'es, 0-WASF,. C) ot,0. ✓, ,::iiSI LOT 9, E3LOCK 4, PUNTER'S RUN, SPOKANE VALLEY, UUA © HOIT ENGINEERING&, INC. (20&)DATE: 3/16/06 SCALE: 3/8" = 1'-0° RF1 Mar 16 06 12:16p Matt Hoit 760-510-3820 p.3 ?x.6 TOP FLATFJOINTS LAPPED M`NfMUM OF 45" AND FULL SURFACE GLUED AND NAILED WITH 10c1 a 5"o.c. WHILE GLUE WET — �� 10 1/4" GLUE OUTSIDE 2x6 TRIM STUD TO EDGE OF VERTICAL FLAT 2x8 AND NAIL WITH 10d e 6"o.c. WNILE GLUE WET FULL SURFACE ALL 'VERTICAL 2x8's AT EAC -1 END OF OPENING TO LAPPED HEADER (WITH BRUSH OR ROLLER) AND NAIL WITH 10d 2"o.c. E.W. WHILE GLUE WET VERTICAL FLAT 2x& (TYPICAL AT BOT! ENDS OF WINDOW OPENING AND CONTINUOUS TO TOP PLATE) % TO SNUG FIT VERTICAL 2x8 OL,T-TO-OUT WIDTI-I OF RF2 DETAIL IS WINDOW RO. + (4' -Cu M1NiMitill) TOP vIEI.0 OF OUTSIDE c _ EDGE OF RF2 NOTCH HEADERS 4"+ THICK HEADER SIZED FOR VERTICAL LOADS BY OTHERS BUT NOT LESS THAN 2x10 2x FILLER NOT REQUIRED WHEN 4"+ THICK NOTCHED HEADER FILLS THE l " SPACE) GLUE INSIDE 2x6 TRIM STUD TO EDGE OF VERTICAL FLAT 2x8 AND NAIL WITH I0d e 6"o.c. WHILE GLUE WET (TYPICAL) MINIMUM 2x8 SILL CROSS PIECE LAPPED AND FULL SURFACE GLUED (WITH BRUSH OR ROLLER) TO VERTICAL FLAT 2x8 a AT EACH END AND NAILED U./III-110d e 2"o.c, WHILE GLUE WET HEADERS CAN BE SLOPED HEADERS GAN BE GUT AT MID -SPAN (45 FOR 4 CATHEDRAL CEILING) AND SPLICED WITH A MINIMUM 2x10 FULL SURFACE GLUED TO BACKSIDE OF HEADERS AT JOINT WHEN WALLS HAVE SPACE ABOVE AND/OR BELOW OPENING FILL WITH 2x6 5T105 16'b.c. 2x6 STUD WALL MINMIUM INSIDE VIEUJ NOTCHING OPTIONAL AT HEADER (STOP AT 2x6 NERD TRIMMER) 2x FILLERS -1ATCHfNG- DEPTH OF HEADER AND SILL CROSS PIECE AND FULL SURFACE GLUED AND NAILED TO -LEADER AND SILL CROSS PIECE WITH 10d 6 "o.c. E.W. WHILE GLUE 15 STILL WET FULL SURFACE GLUE SHEETING ON OUTSIDE FACE OF RF2 AND NAIL W4-1ILE GLUE WET EXTERIOR SHEETING)" NOMINAL PLYWOOD OR OSB NAILED WITH 8d COMMON OR GALVANIZED BOX NAILS 4T 6"o.c. AT ALL EDGES (ALL EDGES NJST BE BLOCKED) AND 12"o.c. AT ALL OTHER SUPPORTS FRAMING LU`1BER DFL No. 2 OR SETTER GLUE MUST BE IMPERVIOUS TO SERVICE CONDITIONS RELATED TO MOISTURE AND TEMPERATURE AND PROVIDE SI-IEAR STRESS CF 50"/in2 THIS DETAIL ONLY PER 200012003 I B.C./ I.R.G. (EXPIRES THEREAFTER) EXPIRES 2 05 LOT 9, SLOCK 4, HUNTERS RUN, SPOKANE VALLEY, WA © 1-101T ENGINEERING, INC. (208) 102-8111 DATE: 3!18/08 SCALE: 3/8" - 1'-0" FF2 Washington State Energy Code: Component Performance Worksheet Zone 2, Other Fuels COLLEEN CRFTSMN LOT 9 BLOCK 4 HUNTER'S RUN SPOKANE VALLEY, WASHINGTON Conditioned Floor Area Conditioned Building Volume Weather Station Spokane co VIKING CONSTRUCTION INC. W. 2605 HAYDEN AVE. HAYDEN , IDAHO 83835 1799 14504 Heating System Size Ducts are located in unconditioned space. I_ Equipment size over design load100% Component Performance, Zone 2, Other: Code Target Values Area UA Vertical Glazing U = 0.400 Overhead Glazing Installed in Attics U = 0.580 Overhead Glazing Installed in Vaults U = 0.580 Doors U = 0.200 Attics U = 0.031 Single Rafter/Joist Vault U = 0.034 Wall (above grade) U = 0.062 Floors U = 0.029 Slab F = 0.540 Below Grade Interior 2' depth, wall U = 0.043 2' depth, slab F = 0.690 3.5' depth, wall U = 0.041 3.5' depth, slab F = 0.640 7' depth, wall U = 0.037 7' depth, slab F = 0.570 Below Grade Exterior 2' depth, wall U = 0.061 2' depth, slab F = 0.600 3.5' depth, wall U = 0.057 3.5' depth, slab F = 0.570 7' depth, wall U = 0.050 7' depth, slab F = 0.420 270 107.9 0 0.0 0 0.0 38 7.6 1799 55.8 0 0.0 1959 121.5 1799 52.2 0 0.0 0 0.0 0 0.0 0 0.0 0 0.0 0 0.0 0 0.0 0 0.0 0 0.0 0 0.0 0 0.0 0 0.0 0 0.0 Target UA Total If the Proposed UA <_ The Target the UA requirements are meet. Check other code requirements 344.9 Btu/hour output KW 34,260 10.0 Proposed Design Values Area UA 237 113.8 0 0.0 0 0.0 38 2.6 1799 55.8 0 0.0 1992 115.5 1799 52.2 0 0.0 0 0.0 0 0.0 0 0.0 0 0.0 0 0.0 0 0.0 0 0.0 0 0.0 0 0.0 0 0.0 0 0.0 0 0.0 Proposed UA Total Copyright 2002, WSUCEEP 02-090 (Version 4) Copied by permission from Washington State University Cooperative Extension Energy Program. (see copyright restrictions) 339.9 3/15/2006 1 of 6 Washington State Energy Code: Component Performance Worksheet Zone 2, Other Fuels Vertical Glazing Plan ID Component Description 2g1 vinyl,clear 1/2" space + argon 2g1 vinyl,clear 1/2" space + argon 2gl vinyl,clear 1/2" space + argon 2g1 vinyl,clear 1/2 space + argon 2g1 vinyl,clear 1/2" space + argon 2g1 vinyl,clear 1/2" space + argon Exterior Doors Plan ID Component Description p -1/p-21 steel insulated p -1/p-21 steel insulated If exempt door is selected, must be <_ 24 SF. Glazing Width Height Feet Inch Feet Inch Area UA V 10-6c 0.480 9 3 ° 5 ° 135.0 64.8 v 10-6c 0.480 1 4 ° 4 ° 16.0 7.7 V 10-6c 0.480 1 6 ° 6 t0 41.0 19.7 v 10-6c 0.480 1 6 ° 4 ° 24.0 11.5 v 10-6c 0.480 1 4 ° 3 ° 12.0 5.8 V 10-6c 0.480 1 3 3 9.0 4.3 V 0 0.000 0.0 0.0 v 0 0.000 0.0 0.0 v 0 0.000 0.0 0.0 v 0 0.000 0.0 0.0 v 0 0.000 0.0 0.0 v 0 0.000 0.0 0.0 • 0 0.000 0.0 0.0 V 0 0.000 0.0 0.0 V 0 0.000 0.0 0.0 Iv 0 0.000 0.0 0.0 Iv 0 0.000 0.0 0.0 v 0 0.000 0.0 0.0 Iv 0 0.000 0.0 0.0 v 0 0.000 0.0 0.0 v 0 0.000 0.0 0.0 V 0 0.000 0.0 0.0 0 0.000 0.0 0.0 Ref. Door U Sum of Area and UA 237.0 113.8 Width Height Qt. Feet Inch Feet Inch Area UA V Custom 0.070 1 3 ° 6 8 20.0 1.4 v Custom 0.070 1 2 8 6 8 17.8 1.2 V 0 0.000 0.0 0.0 v 0 0.000 0.0 0.0 W 0 0.000 0.0 0.0 Iv 0 0.000 0.0 0.0 V 0 0.000 0.0 0.0 V 0 0.000 0.0 0.0 v 0 0.000 0.0 0.0 V 0 0.000 0.0 0.0 ' 0 0.000 0.0 0.0 Sum of Area and UA Copyright 2002, WSUCEEP 02-090 (Version 4) Copied by permission from Washington State University Cooperative Extension Energy Program. (see copyright restrictions) 37.8 2.6 3/15/2006 2 of 6 Washington State Energy Code: Component Performance Worksheet Zone 2, Other Fuels O_ verhead Glazing Installed in Attic Ceilings Plan Component ID Description Glazing Width Height Feet Inch Feet Inch Area UA v 0 0.000 0.0 0.0 v 0 0.000 0.0 0.0 v 0 0.000 0.0 0.0 v 0 0.000 0.0 0.0 v 0 0.000 0.0 0.0 v 0 0.000 0.0 0.0 v 0 0.000 0.0 0.0 Overhead Glazing Installed in Vaulted Ceilings Plan Component ID Description Attics Plan Component ID Description R38 blown Attic STD baffled Vaults Plan Component ID Description Ref. Glazing U Sum of Area and UA 0.0 0.0 Width Height Qt. Feet Inch Feet Inch Area UA Ref. Attic U 10-7 0.031 0 0.000 0 0.000 0 0.000 Ref. Vault U 0 0.000 0 0.000 0 0.000 0 0.000 Sum of Area and UA Sum of Area and UA Sum of Area and UA Copyright 2002, WSUCEEP 02-090 (Version 4) Copied by permission from Washington State University Cooperative Extension Energy Program. (see copyright restrictions) 0.0 0.0 Area UA 1799.0 55.8 0.0 0.0 0.0 1799.0 55.8 Area UA 0.0 0.0 0.0 0.0 0.0 0.0 3/15/2006 3 of 6 0 0.000 0.0 0.0 V 0 0.000 0.0 0.0 V 0 0.000 0.0 0.0 v 0 0.000 0.0 0.0 v 0 0.000 0.0 0.0 v 0 0.000 0.0 0.0 v 0 0.000 0.0 0.0 Ref. Attic U 10-7 0.031 0 0.000 0 0.000 0 0.000 Ref. Vault U 0 0.000 0 0.000 0 0.000 0 0.000 Sum of Area and UA Sum of Area and UA Sum of Area and UA Copyright 2002, WSUCEEP 02-090 (Version 4) Copied by permission from Washington State University Cooperative Extension Energy Program. (see copyright restrictions) 0.0 0.0 Area UA 1799.0 55.8 0.0 0.0 0.0 1799.0 55.8 Area UA 0.0 0.0 0.0 0.0 0.0 0.0 3/15/2006 3 of 6 Washington State Energy Code: Component Performance Worksheet Zone 2, Other Fuels Walls (Above Grade) Plan Component ID Description R19 cavity+RO foam INT 2X6W Lap Floor (over crawl or exterior) Plan Component Ref. Wall U 10-5 0.058 0 0.000 0 0.000 0 0.000 ID Description Ref. R30 vented Joist 16oc Slab on Grade (less than 2 feet below grade) Component Description Plan ID Floor U 10-3 0.029 Custom 0.000 0 0.000 0 0.000 Ref. Slab F 0 0.000 0 0.000 0 0.000 0 0.000 Area UA 1992.0 115.5 0.0 0.0 0.0 Sum of Area and UA Sum of Area and UA Sum of Area and UA Copyright 2002, WSUCEEP 02-090 (Version 4) Copied by permission from Washington State University Cooperative Extension Energy Program. (see copyright restrictions) 1992.0 115.5 Area UA 1799.0 52.2 0.0 0.0 0.0 1799.0 52.2 Slab Length UA 0.0 0.0 0.0 0.0 0.0 0.0 3/15/2006 4 of 6 Washington State Energy Code: Component Performance Worksheet Zone 2, Other Fuels • Below Grade Wall: 2 foot depth, insulated on the interior Plan Component ID Description • Wall Wall Wall Slab Slab Slab UA F Length UA v 0 0.000 0.0 0.000 0.0 V 0 0.000 0.0 0.000 0.0 v 0 0.000 0.0 0.000 0.0 V 0 0.000 0.0 0.000 0.0 Sum of Area, Length and UA Below Grade Wall: 3.5 foot depth, insulated on the interior Plan Component ID Description Ref. Wall U 0.0 0.0 0.0 0.0 Wall Wall Slab Slab Slab Area UA F Length UA Sum of Area, Length and UA Below Grade Wall: 7 foot depth, insulated on the interior Plan Component ID Description Ref. Wall U 0.0 0.0 0.0 0.0 Wall Wall Slab Slab Slab Area UA F Length UA 0 0.000 0.0 0.000 0.0 v 0 0.000 0.0 0.000 0.0 v 0 0.000 0.0 0.000 0.0 v 0 0.000 0.0 0.000 0.0 Sum of Area, Length and UA Below Grade Wall: 7 foot depth, insulated on the interior Plan Component ID Description Ref. Wall U 0.0 0.0 0.0 0.0 Wall Wall Slab Slab Slab Area UA F Length UA Sum of Area, Length and UA 0.0 0.0 Copyright 2002, WSUCEEP 02-090 (Version 4) Copied by permission from Washington State University Cooperative Extension Energy Program. (see copyright restrictions) 0.0 0.0 3/15/2006 5 of 6 0 0.000 0.0 0.000 0.0 V 0 0.000 0.0 0.000 0.0 V 0 0.000 0.0 0.000 0.0 v 0 0.000 0.0 0.000 0.0 Sum of Area, Length and UA 0.0 0.0 Copyright 2002, WSUCEEP 02-090 (Version 4) Copied by permission from Washington State University Cooperative Extension Energy Program. (see copyright restrictions) 0.0 0.0 3/15/2006 5 of 6 Washington State Energy Code: Component Performance Worksheet Zone 2, Other Fuels - Below Grade Wall: 2 foot depth, insulated on the exterior Plan Component ID Description f Wall U Wall Wall Slab Slab Slab Area UA F Length UA w 0 0.000 0.0 0.0 0.000 0.0 0.0 w 0 0.000 0.000 0.0 0.000 0 0.0 w 0 0.000 0.0 0.000 0.000 0.0 w 0 0.000 0.0 0.0 0.000 0.0 Sum of Area, Length and UA Below Grade Wall: 3.5 foot depth, insulated on the exterior Plan Component ID Description Ref. Wall U 0.0 0.0 0.0 0.0 Wall Wall Slab Slab Slab Area UA F Length UA Sum of Area, Length and UA Below Grade Wall: 7 foot depth, insulated on the exterior Plan Component ID Description Ref. Wall U 0.0 0.0 0.0 0.0 Wall Wall Slab Slab Slab Area UA F Length UA 0 0 0.000 0.0 0.0 0.000 0.0 0.0 w 0 0.000 0.000 0.0 0.000 0 0.0 w 0 0.000 0.0 0.000 0.000 0.0 w 0 0.000 0.0 0.0 0.000 0.0 Sum of Area, Length and UA Below Grade Wall: 7 foot depth, insulated on the exterior Plan Component ID Description Ref. Wall U 0.0 0.0 0.0 0.0 Wall Wall Slab Slab Slab Area UA F Length UA 0 0.000 0.0 0.000 0.0 0 0.000 0.0 0.000 0.0 0 0.000 0.0 0.000 0.0 0 0.000 0.0 0.000 0.0 Sum of Area, Length and UA 0.0 0.0 Copyright 2002, WSUCEEP 02-090 (Version 4) Copied by permission from Washington State University Cooperative Extension Energy Program. (see copyright restrictions) 0.0 0.0 3/15/2006 6 of 6