Loading...
2006, 11-27 Permit App: 06004630 Wheelchair RampProject Number: 06004630 Inv: I Application Date: 11/27/2006 Page 1 of 2 THIS IS NOT A PERMIT Penalties will be assessed for commencing work without a permit Proiect Information: _ Permit Use: WHEELCHAIR RAMP Contact: DUPONT CONSTRUCTION Address: 622 E DECATUR C - S - Z: SPOKANE, WA 99206 Setbacks: Front Left: Right: Rear: Phone: (509) 489-5720 Group Name: Site Information: Project Name Plat Key: CONV Name: CONVERTED CNTY DATA District: Nort Parcel Number: 45072.1604 Block: Lot: SiteAddress: 2416 N PARK RD Owner: Name: DUNN, JAMES A Address: 2416 N PARK RD Location:: CSV SPOKANE VALLEY, WA 99212-15 Zoning: UR -3.5 Urban Residential 3.5 Water District: 002 ORCHARD AVENUE Hold: ❑ Area: 14,985 Sq Ft Width: 0 Depth: 0 Right Of Way (ft): 0 Nbr of Bldgs: 0 Nbr of Dwellings: 0 Review Information Review Building Plan Review Released By: Originally Released: 11/27/2006 By: TMELBOU Landuse/Zoning/HE Conditions Released By: r// Permits: Operator: jmm Printed By: jmm Print Date: 11/27/2006 Project Number: 06004630 Inv: I Application Date: 11/27/2006 THIS IS NOT A PERMIT Penalties will be assessed for commencing work without a permit - — -- - - - -- Building Permit Contractor: DUPONT CONSTRUCTION Firm: DUPONT CONSTRUCTION Address: 622 E DECATUR Phone: (509) 489-5720 SPOKANE, WA 99207 This Application: Description Grp Type Notes So Ft Valuation PORCH OPEN R-3 VB WHEELCH 0 $6,500.00 AIR RAMP Totals: 0 $6,500.00 Item Description Units Unit Desc RESIDENTIAL PERMIT FEE 1 SELECT WSBC SURCHARGE 1 SELECT SF PLNS RVW < 7999 SQ FT 1 SELECT Permit Total Fees: Total Project: S(l Ft Valuation 0 $6,500.00 0 $6,500.00 Fee Amount $139.25 $4.50 $55.70 $199.45 Page 2 of 2 Notes: Payment .Summary Permit Type Fee Amount Invoice Amount Amount Paid Amount Owing Building Permit $199.45 $199.45 $0.00 $199.45 $199.45 $199.45 $0.00 $199.45 Disclaimer: Submittal of this application certifies the owner (or person(s) authorized by the owner) has both examined and finds the information contained within to be true and correct, and agrees that all provisions of laws and/or regulations governing this type of work will be complied with. Subsequent issuance of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the code or of any other state or local laws or ordinances. Signature: Operator: jmm Printed By: jmm Print Date: 11/27/2006 Permit Center S &Zane 11707 E Sprague Ave, Suite 106Y PERMIT NUMBER: (,, 3c �� Valle Spokane Valley, WA 99206 PERMIT FEE: (509)688-0036 FAX: (509)688-0037 Community Development -•�-w .s2ok_anevalley.org.com NOV 2 i Residential Construction ❑! New Cons ction ❑ Accessory Bldg Permit Application ❑ Addition/Remodel ❑ Deck ❑ Other: SITE ADDRESS ASSESSORS PARCEL NO: LEGAL DESCRIPTION: Building owner - Name: ''l l Address:Z4 a W City: Zip: Phone: Fax: Contact Per on Name. Phone: Contractor Name: Address: —' City: Zi Phone: Tq- 5 72------Yax: Lie No: ►Exp. City Business Lic No: Describe the scope of work in dAil: Cost of Project: $ **************The followine MUST be complete: (write N/A if not applicable)********************** HEIGHT TO PEAK: DIMENSIONS: # OF STORIES: TOTAL HABITABLE SPACE: MAIN FLOOR TO SQ. FTG: 2 FLOOR SQ. FTG: UNFIN BASEMENT SQ. FTG: IMPERVIOUS SURFACE AREA: FINISHED BASEMENT SQ. FTG: GARAGE SQ. FTG: DECK/COV. PATIO SQ. FTG: 30% SLOPES ON PROPERTY: # OF BEDROOMS: CONSTRUCTION TYPE: HEAT SOURCE: SEWER OR SEPTIC? DiSCLA1MER The permitee verifies, acknowledges and agrees by their signature that: 1) If this permit is for construction of or on a dwelling, the dwelling is/will be served by potable water. 2) Ownership of this City of Spokane Valley Permit inure to the property owner. 3) The signatory is the property owner or has permission to represent the property owner in this transaction. 4) All construction is to be done in full compliance with the City of Spokane Valley Development Code. Referenced codes are available for review at the City of Spokane Valley Permit Center. 5) This City of Spokane Valley Permit is not a permit or approval for any violation of federal, state or local laws, codes or ordinance ns or additional information may be required to be submitted, and ubsequently approved before this applica ' e roce ed. Signatur -- Date Method of Payment: (Faxed permit applications will only 6e eii with major 6ankcard) ❑ Cash ❑ Check astercard ❑ VISA ❑ Other 6ankcard #: Expires: VIN#: Authorized Signature: REVISED 6/252005 11707 E Sprague Ave Suite 106 ♦ Spokane Valley WA 99206 509.921.1000 ♦ Fax: 509.921.1008 ♦ cityhalt@spokanevaltey.org Residential Plan Submittal Minimums ❑ Completed Building & Mechanical application with: Accurate address, Parcel Number and/or Legal Description, description of work, owner and contractor information, signature, and date. ❑ Two sets of plans including Site Plan, elevations, floor plans, foundation plans With details, roof plan, framing plans & details. ❑ Show the height of any proposed buildings or accessory structures. ❑ Floor plan for each floor: Dimension to scale (minimum 1/8") and label each Room (including sq. footage of house and garage on plans) Show each level of existing house and square footage of any additions. ❑ All braced wall panel types: show locations and details of installation, including engineered design. ❑ Egress windows: Provide at least one window or exterior door approved for Emergency escape or rescue from a basement and in every room for sleeping. ❑ Smoke detector locations ❑ 22° X 30" attic access location ❑ 18" X 24" crawl space access: ❑ One-hour separation detail: between house and garage ❑ Floor framing details: Joist type, size, spacing and installation details ❑ Roof framing plan and details ❑ Furnace and hot water heater location. ❑ All header locations: type, size, and connections ❑ Foundation plan ❑ Insulation information ZCA lk> Vim'. ��vr V6��K�,7 0 C a 2(-� 2-4 F✓za-r 3'.0" maximum 3s" maximum clear i T murimam 36" minimum Detling aximum on center. hence from edge of ember to center of boll to be 1-4i" minimum ' � Girder tY� C2 .r a N 1 Z I joistA >/ /` If greater than r l= provide a mi Ifgreaterthan 4'.0"@ t t tlAtJ 44 boos, at provide ■ min. of to -beam come 44 bots, at post. to -beam connections • (Maximum 1 Height shall o (Maximum Post more ban 10 Height ,ball not be more than 10 feet) Post gab" min 24rtfninimumi£covered �}z�mint Natural Grade_, 7' min to daylight — i ---Metal basecap I" min. above concrete or ._L. provide treated wood Y�-imum 2000 psi l2rr� Post 'E 2000 psi concrete (minim 3" minimum — Natural Grade— Post & Beam Connection detail (interior condition) Post Cap installed per manufaelmer's instruction--, Two 1/2" diameter lag bolls lop and bottom typical Poet stat basecap 1" mint above concrete or prortde healed wood r r minimum Y) 24" minimum if covered J1t'rminimurt ledger attachment must be bolted through Post & Bea1n Comlection detail oat cap installed per manufacturer's instruction 24" max. I g^ min. Overhang (4x4) Knee brace I 1%t tk"+`aG7F1dR3 ,i'Ffli'Iies+dSAesaW31M'naa .—'team Two 1/2" diameter lag bolls top and bottom lypiosl ilk FULL 3o IN. MIN GUARD HEIGHT PER SECT. 8318.1 AT LANDING 4 -IN. SPHERE CANNOT PASSTHROUGH 8 -IN. SPHERE CANNOT PASSTHROUGH IN. MIN GvARD HEIGHT PER SECT. 8310. 9 IN. MAX FOR HANDRAIL PER SECT. R315.1 " I IIOfE; OEPIH OB�f M.M1DfSi BE OBt� NO��NT�i YY►! B IUNDMB.- OMBNo MBDWILLM80WUM OPEN RISER PERMITTED -41N. SPHERE WILL NOT PASS THROUGH OR WHERE HEIGHT OF STAIR IS LESS THAN 30 INCHES 10 IN. MIN RUN MAX. RISE 7'/4 IN. VARIATION OF RISER HEIGHTS OR TREAD DEPTHS SHALL NOT EXCEED % IN. See 4X tp details Z X L- - G House wail 14ft maximum rL yerminimum width T Existing X 1 rafters c Existing wall Roofing material sh r-rc 14- "VG ArXI Z) t044 -'f r Sheathing &I .,v Rafter size _Z—_x__S spacing /c;'ec 2x blocking 0 firing AuN Beam size Z x tc> A� Post size x� x 4 minimu* spacing (6 x recommended) Pre-engineered bracket SES i6NED Foe UPu r7 2-.11" minimum depth Existing wall Continuous 2x ledger �— anchor by lag screws L Bracing required Approved metal bracing R311.5.6.3 Handrail grip size. All required handrails shall be of one of the following types or provide equiva- lent graspability. 1. Type I. Handrails with a circular cross section shall have an outside diameter of at least 1'/4 inches (32 mm) and not greater than 2 inches (51 mm). If the handrail is not circular it shall have a perimeter di- mension of at least 4 inches (102 mm) and not greater than 61/4 inches (160 mm) with a maximum cross section of dimension of 21/4 inches(57 mm). 2. Type H. Handrails with a perimeter greater than 61/4 inches (160 mm) shall provide a graspable finger re- cess area on both sides of the profile. The finger re- cess shall begin within a distance of 3/4 inch (19 mm) measured vertically from the tallest portion of the profile and achieve a depth of at least s/16 inch (8 mm) within 1/g inch (22 mm) below the widest por- tion of the profile. This required depth shall con- tinue for at least 3/8 inch (10 mm) to a level that is not less than 13/4 inches (45 mm) below the tallest por- tion of the profile. The minimum width of the hand- rail above the recess shall be 1'/4 inches (32 mm) to a maximum of 23/4 inches (70 mm). Edges shall have a minimum radius of 0.01 inches (0.25 mm). R311.5.7 Illumination. All stairs shall be provided with il- lumination in accordance with Section R303.6. R311.5.8 Special stairways. Circular stairways, spiral stairways, winders and bulkhead enclosure stairways shall comply with all requirements of Section R311.5 except as specified below. R311.5.8.1 Spiral stairways. Spiral stairways are per- mitted, provided the minimum width shall be 26 inches (660 mm) with each tread having a 71/2 -inches (190 mm) minimum tread depth at 12 inches from the narrower edge. All treads shall be identical, and the rise shall be no more than 91/2 inches (241 mm). A minimum headroom of 6 feet 6 inches (1982 mm) shall be provided. R311.5.8.2 Bulkhead enclosure stairways. Stairways serving bulkhead enclosures, not part of the required building egress, providing access from the outside grade level to the basement shall be exempt from the require- ments of Sections R311.4.3 and R311.5 where the maxi- mum height from the basement finished floor level to grade adjacent to the stairway does not exceed 8 feet (2438 mm), and the grade level opening to the stairway is covered by a bulkhead enclosure with hinged doors or other approved means. R311.6 Ramps. R311.6.1 Maximum slope. Ramps shall have a maximum slope of one unit vertical in eight units horizontal (12.5 -per- cent slope). R311.6.2 Landings required. A minimum 3 -foot -by -3 -foot (914 mm by 914 mm) landing shall be provided: 1. At the top and bottom of ramps, 2. Where doors open onto ramps, 3. Where ramps change direction. BUILDING PLANNING R311.6.3 Handrails required. Handrails shall be provided on at least one side of all ramps exceeding a slope of one unit vertical in 12 units horizontal (8.33 -percent slope). R311.6.3.1 Height. Handrail height, measured above the finished surface of the ramp slope, shall be not less than 34 inches (864 mm) and not more than 38 inches (965 mm). R311.6.3.2 Handrail grip size. Handrails on ramps shall comply with Section R311.5.6.3. R311.6.3.3 Continuity. Handrails where required on ramps shall be continuous for the full length of the ramp. Handrail ends shall be returned or shall terminate in newel posts or safety terminals. Handrails adjacent to a wall shall have a space of not less than 1.5 inches (38 mm) between the wall and �__the handrails. .S r�&7 4d,4 4Af elm Af (Wt/T SECTION R312 GUARDS R312.1 Guards required. Porches, balconies or raised floor surfaces located more than 30 inches (762 mm) above the floor or grade below shall have guards not less than 36 inches (914 mm) in height. Open sides of stairs with a total rise of more than 30 inches (762 mm) above the floor or grade below shall have guards not less than 34 inches (864 mm) in height measured vertically from the nosing of the treads. Porches and decks which are enclosed with insect screening shall be provided with guards where the walking surface is lo- cated more than 30 inches (762 mm) above the floor or grade below. R312.2 Guard opening limitations. Required guards on open sides of stairways, raised floor areas, balconies and porches shall have intermediate rails or ornamental closures which do not allow passage of a sphere 4 inches (102mm) or more in di- ameter. Exceptions: 1. The triangular openings formed by the riser, tread and bottom rail of a guard at the open side of a stairway are permitted to be of such a size that a sphere 6 inches (152 mm) cannot pass through. 2. Openings for required guards on the sides of stair treads shall not allow a sphere 4 3/B inches (107 mm) to pass through. SECTION R313 SMOKE ALARMS [F] R313.1 Smoke alarms. Smoke alarms shall be installed in the following locations: 1. In each sleeping room. 2. Outside each separate sleeping area in the immediate vi- cinity of the bedrooms. 3. On each additional story of the dwelling, including base- ments but not including crawl spaces and uninhabitable attics. In dwellings or dwelling units with split levels and without an intervening door between the adjacent levels, 2003 INTERNATIONAL RESIDENTIAL CODE® 51 WASHINGTON STATE AMENDMENTS 8311.6.33 Continuity. Handrails where required on ramps shall be continuous for the full length of the ramp. Handrail ends shall be returned or shall terminate in newel posts or safety terminals. Handrails adjacent to a wall shall have a space of not less than 1.5 inches (38 mm) between the wall and the handrails. At least one handrail shall extend in the direction of ramp run not less than 12 inches (305 mm) horizontally beyond the top and bottom of the ramp runs. (Insert Facing Page 52) Effective 7/01/04 PROVIDE DIAGRAMS AND ENGINEERING LAYOUTS FOR ROOF TRUSSES, BEAMS AND FLOOR SYSTEMS PRIOR TO FRAMING INSPECTIONS CITY COPY THIS BUILDING SUBJECT TO FIELD INSPECTION CORRECTIONS REVIEWED FOR COD COMPLIANCE SP02KFAN[F VALLEY Rt k_ DING VISION