Loading...
2005, 09-12 Permit App: 05003345 Pole BldgProject Number: 05003345 Inv: 1 Application THIS IS NOT A PERMIT Penalties will be assessed for commencing work without a permit Date: 09/12/2005 Page 1 of 2 Project Information: Permit Use: DETACHED POLE BUILDING Setbacks: Front Left: Right: Rear: Site Information: agummure Plat Key: 002955 Name: WOODLAWN PARK Contact: ALBERTSON, MATT & STACI Address: 1008 S PARK RD C - S - Z: SPOKANE VALLEY, WA 99212 Phone: (509) 879-9290 Group Name: Project Name: District: F Parcel Number: 35244.0901 SiteAddress: 1008 S PARK RD Location:: CSV Zoning: AGSUB Water District: Area: .00 Acres Block: Width: 0 Nbr of Bldgs: 1 Nbr of Dwellings: 1 Review Information: Lot: Owner: Name: ALBERTSON, MATT & STACI Address: 1008 S PARK RD SPOKANE VALLEY, WA 99212 Hold: ❑ Depth: 0 Right Of Way (ft): 60 Review Site Plan Review Released By: Plan Review Originally Released: 09/12/2005 By: KKENDAL Released By: Sewer Review Released By: Permits: Originally Released: 09/12/2005 By: cjjanssen Operator: CJJ Printed By: CJJ Print Date: 09/12/2005 Project Number: 05003345 Inv: 1 Application THIS IS NOT A PERMIT Penalties will be assessed for commencing work without a permit Date: 09/12/2005 Page 2 of 2 Building Permit Contractor: OWNER Firm: OWNER Phone: (000) 000-0000 This Application: Total Project: Description Grp Type Notes Su Ft Valuation So Ft Valuation GARAGE U-1 VB 720 $13,680.00 720 $13,680.00 Item Description RESIDENTIAL PERMIT FEE STATE SURCHARGE Notes: • Totals: 720 $13,680.00 720 $13,680.00 Units Unit Desc 1 SELECT 1 SELECT Permit Total Fees: Fee Amount $237.25 $4.50 CONTOL AREA FOR DRAINAGE MORITORIUM SEE MAPS FOR SPECIFICS Payment Summary: Permit Type Building Permit Fee Amount Invoice Amount $241.75 $241.75 $241.75 Amount Paid Amount Owing $0.00 $241.75 $241.75 $241.75 $0.00 $241.75 Disclaimer: Submittal of this application certifies the owner (or person(s) authorized by the owner) has both examined and finds the information contained within to be true and correct, and agrees that all provisions of laws and/or regulations governing this type of work will be complied with. Subsequent issuance of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the code or of any other state or local laws or ordinances. Signature: Operator: CJJ Printed By: CJJ Print Date: 09/12/2005 Sp"okane Valle CsS -3 1 BUILDING PERMIT APPLICATION WORKSHEE City of Spokane Valley Community Development Departmel Building Divisio 11707 E. Sprague Avenue, Suite 10 Spokane Valley, WA 9920 one: (509) 683-0036; Fax: (509) 688-003 rte. Street Address: C UI b tTE`1NPORMAT[ON /00 8 S, )06,(4__ Jeb% 0,1-1 Assessor's Tax Parcel Number(s):9:7944:COD I Legal Description: PERMIT DESCRIPTION: Building Permit ❑ Relocation f�lY _ ❑ Change in Use ❑ Grading ❑ Manufactured Home ❑ Tenant Improvement ❑ Fire Safety ❑ Other OWNER/APPLICANT INFORMATION )fl Owner: %I d- S f7tu e.:13vrl Phone6_67,*?9•`iz9a Fax: Address: /008 .5 4q j itystate Zpf Code ❑ Contractor: Phone: Fax: Address: City ❑ Applicant: Phone: Fax: Address: City State Zp Code ❑ Architect: Phone: Fax: Address: State Zp Code City Contact: WA State Contractor License #: Spokane Valley Bus. Liscense #: Contact: State Zp Code PERMIT/BUILDING INFORMAT[ON HEIGHT TO PEAK: /it DIMENSIONS: K 2.4?.3 K. Io # OF STORIES: MAIN FLOOR TO SQ. FTG: 2"" FLOOR SQ. FTG: UNFIN BASEMENT SQ. FTG: FINISHED BASEMENT SQ. FTG:GARAGE k SQ. FTG: 7Z0 DECK/COV. PATIO SQ. FTG: OCCUPANCY GROUP: CONSTRUCTION TYPE: HEAT SOURCE: # OF BEDROOMS: TOTAL HABITABLE SPACE: IMPERVIOUS SURFACE AREA: COST OF PROJECT: 30% SLOPES ON PROPERTY: SEWER OR ON-SITE SEPTIC SYSTEM? MANUFACTURED HOME Width: Manufacturer: Length: Year. RELOCATION Pit Set: Previous Address: Proposed Use: FIRE SAFETY Fire Sprinkler. Tent: # of Heads: Fire Alarm: Paint Booth: Fireworks Display: Blasting: Date/Time: Valuation: Above/Underground Storage Tank Size: WASHINGTON STATE NON-RESIDENTIAL ENERGY CODE Plans Examiner: Address: Phone: Fax: City State Inspector. Phone: Fax: Address: Zip City State Zip SPECIAL INSPECTIONS ❑ BOLTING ❑ CONCRETE Firm Name: ❑ REINFORCEMENT Phone: Inspector(s): Fax: ❑ WELDING DISCLAIMER The permitee verifies, acknowledges and agrees by their signature that: 1) If this permit is for construction of or on a dwelling, the dwelling is/will be served by potable water. 2) Ownership of this City of Spokane Valley Permit inure to the property owner. 3) The signatory is the property owner or has permission to represent the property owner in this transaction. 4) All construction is to be done in full compliance with the City of Spokane Valley Development Code. Referenced codes are available for review at the City of Spokane Valley Permit Center. 5) This City of Spokane Valley Permit is not a permit or approval for any violation of federal, state or local laws, codes or ordinances. Ownership of resuJg deve Print Name t rights granted by any issued permit inure othe prop -,-1 •w - r. Signature �►®► . `� 4 TT 'I-16,e_TS l Method of Payment: (Faxed permit applications will only be accepted with major bankcard) Cash Bankcard #: Authorized Signature: ❑ Check ❑ Mastercard ❑ VISA Expires: VIN#: D Other 1 Okie.nuiLt • LANNING DEPT. A 70' / Job Name: Truss ID: TO1 Qty: 1 Drwg: I ba8 X -LAIC xesCrT 5372 WOO' D 1 0- 2-12 7760 5.541' 7.75• 2 21- a- a 2760 5.50' 2.75• tato P$QDfAonorre 00w11 are b.544 04e1.T cm the truss notarial at Barb bearing TC row= LEL ffim Cbl 1-2 -6361 0.11 0.38 4.48 2-3 -5310 0.12 0.17 0.49 1-4 -5310 0.11 0.37 0.49 4-5 -6301 0.11 0.38 0.48 V -4 D 7 '3 b7/nb/Ln07 DC FORCE all. 8ND Cal 6-7 5907 0.41 0.03 0.46 7-e 3950 0.22 0.07 0.28 E-9 3950 0.22 D.D7 0.28 9-10 5907 0.43 0.01 0.46 RIB POHQ CSI 118 FORCE 2-7 -1714 0.41 3-9 1011 3-7 1591 0.53 4-9 -1714 CBL 0.53 0.11 TC 2x6 001. 2400E -2.0E BC 206 DFL 2400E -2.0E WEB 2x4 DFL STUD Lumber shear allowables are per NDS. THIS DESIGN IS THE COMPOSITE RESULT OF MULTIPLE WAD CASES. Loaded for 10 PSF oonoancurrem OCLI_ Lorded for 200 Ib non-0oncurrerd moving 8CLL ASCE7-02 SNOW LOAD DESIGN CRITERIA: Pg= 40 psi', Ce=1.0,1=1-O.C1=1.10 Designed for a posl•frame building application. 1 D esigned per ANSlTP11.2002 This design does not aco0unl lor long lean time dependeM loading (creep). ',Aiding Designer must account for this. Rehm to Joint QC Derail Sheet for Maximise Rotational Tolerance used IRC419C muss plate wadies are based on testing and approval as required by IBC 1703 e nd AN9VT01 and are reported In available documents such es 1060 51607. 4 5 4-9 S=6.6 4-6 24.0-0 design based on chord bracing Spirited pet the following schedule: rrtax 0.C. from to TC 24.00' 0-0. 0 24- 0- 0 BC 120.00" 0-0.0 24-0-0 UPLIFT REACTION(S): Support CSC Wind Non -Wind 1 -56510 2 -56610 TMs truss Is designed using the ASCE7-02 Wind Specification Bldg Enclosed r Yea. Importance Factor =0.97 Truss Location = Not 5,11120110 Hurricane/Ocean Line = No , Exp Category = C ®dg Length= 54.00 rt, Bldg Width • 24.00 R Mean roof hralgh( = 14.25 H, mph = SS TPI Low Berard, Dead Load = 3.6 pat Designed as Main Wind Force Resisting System and Components and Cladding Tributary Area =120 sqh T 44-1 MX/6.16 15HIP 6 7 6 9 10 104.1 MAX DEFLECTION (span) : Mai la MBA 7.8 (LIVE) La -0.29' Do--Ot04' T=-0.33' Joint Locations 1 00.0 6 0-2.0 2 6- 4-13 7 6- 6-14 I 12. 0-0 i 12.0-0 417-7-3 9 15-5.2 S 24- 0- 0 10 24- 0- 0 EXPIRES: 01113:00 All plaits are 20 gauge Truswal Connectors unless preceded by 'MX" for HS 20 gauge or for 16 gouge, posttloned per Join. Detail Reports available from Truswal software, unless noted. 9/ 7/2005 Scale: 3f16" = 1' TIMBERLINE TRUSS 6525 N. FREVA, SPOKANE WA. 9021 7 WARNING Read all notes on this sheet and give a copy of it to the Erecting Contractor. Tt:s design is too an indi.iiva_ hddmg compote' mi miss haws h las tarn ttsd an srec£1:aeioas 91Osided 311113,113(7103101 n of l=ee scot dant E. w-ocdan:e e.;th eine cental .CtiSM or TPI 1114 AFP.1 design se 114.145 Wes negr,nsl46ry. is assvme4 ler dinasso)nsl as ,rary. Dinaxmct6 1_-4 lobe lrrifiel tr tie chilies em coa.femercr mdlie bo4lup desiper prim to 1.1101t 71r 1s3Anp destare.Dux seemsea thio[ 1x lams eitscd on 0245 design ane en exceed the Isa.ing 1mpo.ai t5 dr bell hulling mit awl the peri. -air a [X08.30. the nein amens thin de- op chant is ImvalIy braced ty 13e roar re now fletleiog icer Or solar dorsi It luerear trw-d In • sirii stuthbly menial dironly nu. -:rt, wane wheru w- mied. Brae by s1 =o :s as Wesel eapp.n of mrtuyeaae_< menhrs only to .educe fuel:iino knpd, This cermooeni Eo0 me bo pb24 in any ensskponrn' au s.7-0 COOK' the- w-'imn' COneenl of the wed w eseeed 196 m.l'm Cause onnecto, glue mrrosiaa Fa6i eie, tec fk. ds, ami Mahe this tress in emardsmr eil she folle+.ina s..,dwd,: 'lobo 1,1 Cutting Dere@ Reports awibble is pulpa. frons Teen.° software. ANSI/TTI1'_ "WTCh 7 - Wad Tress Comeil 0f America Pushed D.jp Reaporubnlr'.ien.'HM4DL1r:G JNSTALLLNG &.'D BRACING METAL PLATE CONNECTED WOOD TRUSSES' - (1119-91) m4-1113-91 SWM ABY SHEET b1 IPL Tim Truss 01.14 lusanne?PI? is bcatoi n DY sofa Alsiiraa t9iromi 53119. The An mere Fnress On5 Pain- Aueciriln (APPA) is leered es 111 119th Street h'N', S:e 003. Washington. D; 20036 Eng. Job: .EJ. Chit: CLP Dognr. CLP WO: STOCK -2003 TC Uwe 40.00 pot TC Dead 5.00 ps1 BC Live 0.00 psi BC Deed 1.00 pal TOTAL 46.00 ps1 Outface L=1.15 P=1.15 Rep Mbr Bnd 1.00 O.C.Specing 5- 0- Design Spec I3C-2003 Seqn 16.4.24 - 0 A"Al CONTRACTOR TO VERIFY ACTUAL NORTH ON JOBSITE .d PROTECTION AND OPENINGS BETWEEN DWELLING AND PRIVATE GARAGE SHALL HAVE: 1) MATERIALS APPROVED FOR ONE HOUR FIRE RESISTIVE CONSTRUCTION ON THE GARAGE SIDE: ❑ 5/8" TYPE "X" GYP BOARD (HABITABLE SPACE ABOVE) OR ❑ 1/2" GYP BOARD (RESIDENCE/ATTIC, FLOOR/CEILING) 2) OPENINGS BETWEEN GARAGE AND RESIDENCE SHALL BE EOUIPPED WITH SOLID WOOD DOOR, SOLID OR HONEYCOMB CORE STEEL DOC RS NOT LESS THAN 1 3/8", OR 20 MINUTE FIRE RATED 30' 10' 10' 10' F W A LKW A N VI N O O SCSJ 0 Do x to OPTION: 4" CONCRETE SLAB NOTE: ALL POSTS ARE ON GRADE, SMOOTH PT 6x6 #2 HEM FIR, TROWEL FINISH UNLESS NOTED OTHERWISE EMBED ALL 4x / I IN 12"0, 2'-0" DEEP (\� 3068(� I` / DETAIL 1/S3 TYP FOUNDATION PLAN 12' / -1` . 1 24' �—/ 12' -T vN SCALE: 3/16"=1' 1. ALL CONSTRUCTION TO BE IN ACCORDANCE WITH THE 2003 INTERNATIONAL BUILDING CODE. 2. ALL FRAMING MATERIAL SHALL BE HEM FIR NO. 2 OR BETTER. DOUGLAS FIR NO. 2 MAY BE SUBSTITUTED AS AN ALTERNATIVE. WOOD IN CONTACT WITH EARTH AND/OR CONCRETE SHALL BE PRESSURE TREATED, 0.6 RETENTION. 3. CONCRETE DESIGN BASED ON A COMPRESSIVE STRENGTH OF 2500 PSI AND NO SPECIAL INSPECTION PER UBC 306 REQUIRED. RECOMMENDED CONCRETE STRENGTH IS 4000 PSI FOR DURABILITY ONLY. 4. ROOF SHEATHING SHALL BE PAINTED 29 GA. RIBBED STEEL. FASTENED SHEATHING TO PURLINS WITH 1 1/2" #9 SCREWS WITH NEOPRENE WASHERS AT 9" C/C. 5. SIDE SHEATHING SHALL BE PAINTED 29 GA. RIBBED STEEL. FASTENED SHEATHING TO GIRTS WITH 1 1/2" #9 SCREWS WITH NEOPRENE WASHERS AT 9" C/C 6. TRUSS MANUFACTURER SHALL VERIFY LOAD BEARING POINTS FOR ALL TRUSSES. 7. (4) 16d GALV. NAILS MAY BE SUBSTITUTED FOR (3) 20d. 8. DESIGN LOADS: LIVE LOAD: 20 PSF SNOW LOAD: 40 PSF WIND SPEED: 90 MPH EXP C SEISMIC ZONE: D1 SOIL BEARING: 1500 PSF NOTES ® = AT C/C = CENTER TO CENTER DBL = DOUBLE GALV = GALVANIZED HD = HOT DIPPED MIN = MINIMUM PT = PRESSURE TREATED SCSJ = SAW CUT JOINT SW = SHEAR WALL TYP = TYPICAL LEGEND EXTENTS OF CONCRETE SLAB .O 37708 SSjpNAL�G I EXPIRES 08/18/ t,0-71 r�rrrtw u OT: t,' AUUKtJS H Rt UNK L tl UUNL: PP,OJECf SHT. IME SMT. NO, DATE: 8/31/05 PROJ. NO.• 1914.0 / 3142 1008 SOUTH PARK MATT ALBERTSON FOUNDATION PLAN c DING. NO.: 0 SCALE: NOTE SPOKANE ALL A 99212 ffm I SPOKANE COUNTY 24'x3O'xi O' POLE BUILDING AND NOTES J 1 (21) 20d HD GALV (3) SIDES, STAGGERED 1" EXPOSED 12 a CONCRETE 4 SLAB PRE ENGINEERED TRUSSI GRADE + 2x6 GIRTS iF IIII S TO POST WITH AT 24" C/C 70d EIIIE (RU BOLT AND TYP, U.N.O. IIIIIIIII 14' (GALV NAILS, MIN DEPTH I I M I IE PRE—DRILL. NOTCH POST AND 3'-6lEll 10' FIT TRUSS FLUSH WITH POST. 9'-l" (4'-0" IF - III CLEAR ± NO SLAB) II�IIIII CONCRETE PT 2x10 I{—III VIII= BASE GIRT —III OPTIONAL CONCRETE SLAB �I—I1 _ _ _IIIIIII lll�l I. III���III11jIIlI li r 24' II BELL OUT TO 2'-0" SECTION A - MAIN BUILDING SECTION SCALE: 3/16"=1' DETAIL 1 - TYP FTG N.T.S. 2x8 B� 20d AT 12" C/C ASt� G .0 37708 EXPIRES 08/18/p DETAIL 2 - HEADER N.T.S. Im DRAWN BY: CWB APPROVED BY: CWB DRESS WHFRE WORK WILL BE DONE I PROJECT ALBERTSON sir. tvkE MAIN BUILDING SECTION DATE: 8/31/05 PROJ NO • 19140 / 3142 1008 SOUTH PARKMATT D NO.: 0 SCA : NOTED SPOKANE VALLEY. WA 99212 24'X3O'X1O' POLE BUILDING AND DETAILS Em I SPOKANE COUNTY i 3068 16'x8' 0/H DOOR I NORTH ELEVATION SCALE: 3/16"=1' WEST ELEVATION SCALE: 3/16"=1' f! f y, 3 I H �I�� ASN't 11 111111 11 111 1 L--Lj-MHH-H-i T•.. O V6 37708 `sSIGNALG EXPIRES 08/18/0 SOUTH ELEVATION SCALE: 3/16"=1' EAST ELEVATION SCALE: 3/16"=1' DRAWN BY: CWB APPROVED BY• CWB ADDRESS WHERE 140RK WILL BE ONE: PROJECT MATT ALBERTSON " 4'x3O'x1O' POLE BUILDING SHT. "E BUILDING ELEVATIONS SHT. Na.: S4 DATE: 8/31/05 PROJ. NO • 1914.0 / 3142 1008 SOUTH PARK DWG NO.: 0 SCALE: NOTED SPOKANE VALLEY A 9212 SPOKANE COUNTY PROVIDE DIAGRAMS AND ENGINEERING LAYOUTS FOR ROOF TRUSSES, BEAMS AND FLOOR SYSTEMS PRIOR TO FRAMING INSPECTIONS CITY COPY THIS BUILDING SUBJECT TO FIELD INSPECTION CORRECTIONS biiotactz, 1: COMPLIANCE "i",SION ,