2008, 03-04 Permit App: 08000594 Basement Remodel Project Number: 08000594 Inv: 1 Application Date: 3/4/2008 Page 1 of 2
THIS IS NOT A PERMIT
Penalties will be assessed for commencing work without a permit
Project In formation:
Permit Use: BASEMENT REMODEL Contact: KEPLER,STEVEN J/QUICK,DANIEL
Address: 1806 N OBERLIN RD
C-S-Z: SPOKANE VALLEY,WA 99206
Setbacks:Front Left: Right: Rear: Phone: (509)475-5793
Group Name:
Site Information: Project Name: BASEMENT REMODEL
Plat Key: Name: University View District: Nort
Parcel Number: 45084.1408 Block: 2 Lot: 8
SiteAddress: 1806 N OBERLIN RD Owner:Name: KEPLER,STEVEN J/QUICK,DANI
Address: 1806 N OBERLIN RD
Location::CSV SPOKANE VALLEY,WA 99206
Zoning: UR-7 Urban Residential-7
Water District: 011 MODERN Hold: ❑
Area: 5,500 Sq Ft Width: 0 Depth: 0 Right Of Way(ft): 0
Nbr of Bldgs: 0 Nbr of Dwellings: 0
Review Information:
Review
Building Plan Review Released By:
Originally Released: 3/4/2008 By: tmelbourn
Operator: JD Printed By: jmm Print Date: 3/4/2008
Project Number: 08000594 Inv: 1 Application Date: 3/4/2008 Page 2 of 2
THIS IS NOT A PERMIT
Penalties will be assessed for commencing work without a permit
Building Permit
Contractor: OWNER Firm: OWNER
Phone: (000)000-0000
Building Characteristics
Group: R-3 Type: VB
Total Area 850
This Application: Total Project:
Description Grp Type Notes Sq Ft Valuation Sq Ft Valuation
BASEMENT R R-3 VB BASEMENT 850 $4,250.00 850 $4,250.00
REMODEL
Totals: 850 $4,250.00 850 $4,250.00
Item Description Units Unit Desc Fee Amount
RESIDENTIAL PERMIT FEE 1 SELECT $111.25
WSBC SURCHARGE 1 SELECT $4.50
SF PLNS RVW<7999 SQ FT 1 SELECT $44.50
Permit Total Fees: $160.25
Notes 11 _ .,., . a w�..,N. �
Payment Summary:
Permit Type Fee Amount Invoice Amount Amount Paid Amount Owing
Building Permit $160.25 $160.25 $0.00 $160.25
$160.25 $160.25 $0.00 $160.25
Disclaimer:
Submittal of this application certifies the owner(or person(s)authorized by the owner)has both examined and finds the information
contained within to be true and correct,and agrees that all provisions of laws and/or regulations governing this type of work will be
complied with. Subsequent issuance of a permit shall not be construed to be a permit for,or an approval of,any violation of any of
the provisions of the code or of any other state or local laws or ordinances.
Signature:
Operator: JD Printed By: jmm Print Date: 3/4/2008
Permit Center
Scrry or 11703 E Sprague Ave, Suite B-3 PERMIT NUMBER: ' - 5-C1
pokane Spokane Valley,WA 99206 PERMIT FEE:
jValley� (509)688-0036 FAX: (509)688-0037
www.spokanevalley.org
Community Development
Residential Construction New Construction Accessory Bldg
Permit Application [Addition/Remodel Deck
n Other:
SITE ADDRESS: I L( L
ASSESSORS PARCEL NO: LEGAL DESCRIPTION:
Building Owner: Contractor: ,n >
Name: C Name:
\ I �, l . N ` k (.� Lam` ._
Address: ! Address:
V i< k
City: State: Zip:c. City: State: Zip:
Phone: � Fax: Phone: Fax:
1;5( S `t I `; 5'/�'l . >
Contractor Lic No: Exp Date:
Contact Person City Business Lic.No:
Name: (:;k i
Phone: '>( ti L( -f -i ci
Describe the scope of work in detail: Cost of Project: $ r t
G YY1 Y��� • 1 }'1/4-AC lL;;A �'i;,,�l: -..1( (�I t_ t11: �; Il A' �1111c ( : l 1 C{ yp l t (, )
Proposed Use: ,". .y> ��� ��.� / t�;.t ‘r,
**************The following MUST be complete: (write N/A if not applicable)**********************
HEIGHT TO PEAK: DIMENSIONS: #OF STORIES: TOTAL HABITABLE SPACE:
MAIN FLOOR TO SQ. 2"D FLOOR SQ. FTG: UNFIN BASEMENT SQ. FTG: IMPERVIOUS SURFACE
FTG: AREA:
r 1( -
FINISHED BASEMENT GARAGE SQ. FTG: DECK/COV. PATIO SQ. FTG: 30% SLOPES ON
SQ. FTG: PROPERTY:
#OF BEDROOMS: CONSTRUCTION TYPE: yEAT SOURCE: EWER OR SEPTIC?
The permitee verifies,acknowledges and agrees by their signature that: 1) If this permit is for construction of or on a dwelling,the
dwelling is/will be served by potable water. 2) Ownership of this City of Spokane Valley Permit inure to the property owner. 3) The
signatory is the property owner or has permission to represent the property owner in this transaction. 4) All construction is to be done
in full compliance with the City of Spokane Valley Development Code. Referenced codes are available for review at the City of
Spokane Valley Permit Center. 5) This City of Spokane Valley Permit is not a permit or approval for any violation of federal,state or
local laws,codes or ordinances.6) Plans or additional information may be required to be submitted, and subsequently approved before
this application can be processed.
SIGNATURE: � DATE: .
Method of Payment:
0 Cash 0 Check 0 Mastercard 0 VISA
Bankcard#: Expires: VIN#:
Authorized Signature:
REVISED 2/15/07
SCITYO��e 11703 E Sprague Ave Suite B-3• Spokane Valley WA 99206
•509.688.0036 ♦ Fax: 509.688.0037 •
Valley
ECompleted Building and Mechanical Application with: Accurate address, Parcel
Number and/or Legal Description, description of work, owner and contractor
information, signature and date.
❑X Three (3) sets of plans including Site Plan, elevations, floor plans, foundation plans
with details, roof plan, framing plans and details.
I:3 Show the height of any proposed buildings or accessory structures.
MX Floor plan for each floor: Dimension to scale(minimum 1/8") and label each room
(including sq footage of house and garage on plans) show each level of existing
house and square footage of any additions.
. ❑X Egress windows: Provide at least one window or exterior door approved for
emergency escape or rescue from basement and in every room for sleeping.
Ex Floor framing details: Joist type, size, spacing and installation details.
❑X Roof framing plan and details
❑X Furnace and hot water heater location
❑X All header locations: type, size and connections
MFoundation plan
❑X Insulation information
❑x Decks and Stairway details
All braced wall panel types: show locations and details of installation, including
engineered design
Smoke detector locations
22" x 30" attic access location
18" x 24" crawl space access
One-hour separation detail: between house and garage
For City Use,.Rnlyr
SCITY OF PLUS Project Number
poIie Project Address
4000.
Mane
alley
lle °
11703 E Sprague Ave Suite B-3 ♦ Spokane Valley WA 99206
509.688.0036 ♦ Fax: 509.688.0037 ♦ permitcenter@spokanevalley.org
As part of our on-going commitment to customer service during the review process of your project
application, we are providing you with a TARGET DATE for the initial technical application review. If for
any reason we cannot meet this date, we will contact you with a revised target date.
/
Your application review TARGET DATE is
I e t�>
The TARGET DATE is the date we estimate your project application will have had its initial technical
review. It is not the date for approval or permit issuance.
Tips for a Smoother Project Application Review
➢ Submit complete, accurate plans and documents.
Extra time may be required for re-submittals as project application reviewers work on multiple applications and it
may be several days before they can look at your new or revised information.
➢ Designate a specific contact person to communicate with the City.
While the person designated as the applicant's contact person with the City can be changed, one individual with the
expertise for dealing with reviewer comments would be the best choice for the entire review process.
➢ Call staff regarding the status of your project only after the target date shown at the top of the page.
Although you should be contacted on or by the target date,please feel free to contact us if you haven't heard from us
by your target date. Staff may contact you before the target date if the initial review is complete. By following this
procedure,you will save time and allow the reviewers to complete the work more expeditiously.
Steps in the Permit Process
1. Counter Complete. Your application has been accepted as counter complete. This means all of the required
documents, as indicated on your Pre-Application Checklist have been submitted or have been approved for deferred
submittal. This does not prevent technical staff from requesting additional information as a result of their technical review.
2. Quality Check. The next step in the process is a quality check to make sure that the application is reviewable and free
from substantive flaws that would prevent technical staff from completing the technical review once it is started. When
this step is complete, your application will be routed to the appropriate staff and remain in their review queue until it
comes up for review.
3. Technical Compliance. Once an application is administratively complete, it is routed to technical staff for compliance
review. Depending on the type of project, technical staff may include multiple reviewers. You should be contacted by
phone, fax, email,or mail by your TARGET DATE once the initial technical compliance review is complete.
4. Permit Issuance. When the technical compliance review of the application is complete, including any subsequent re-
submittals, each reviewer will approve their section of the application and route it to the Permit Center. When all sections
of the application are received, a Permit Specialist will process the application and contact the person specified on your
application for permit pick-up. Information regarding fees and pre-construction meetings (if required) will be provided by
the Permit Specialist at that time.
WHITE-APPLICANT PINK-BUILDING FILE REV 9/07
• New project 0
eNCITY Project Previous pre-app meeting 0
poxane Transmittal Plan revisions °
City of Spokane Valley Transmittal Date:
Valley Community Development Friday,February 29,2008
Department
11703 E.Sprague Ave,Suite B3
Spokane Valley,WA 99206
Phone:509.688.0036
Site Address: 1806 N OBERLIN RD Project Number: 08000594
Parcel Number: 45084.1408
Zoning: UR-7 Water District: MODERN
Fire District: FD 01
Applicant: KEPLER, STEVEN J/QUICK, DANIE Owner: KEPLER, STEVEN J/QUICK, DANIE
1806 N OBERLIN RD 1806 N OBERLIN RD
SPOKANE VALLEY, WA 99206 SPOKANE VALLEY, WA 99206
(509)475-5793
e-mail: e-mail:
Contact: KEPLER, STEVEN J/QUICK, DANIE Occupant:
1806 N OBERLIN RD
e-mail:
SPOKANE VALLEY, WA 99206
(509)475-5793
e-mail:
Contractor: OWNER Arch/Engineer: ID F (C F� I i
=1 ��_;,
( ) - 0 �; - rte
e-mail:
Project BASEMENT REMODEL
Description:
Building Landuse Engineer Utilities Health Fire Dist Assessor
APPLICATION !
PLANS r.
Please send all plan review and project comments via e-mail to the
highlighted individuals.
WHEN INTERIOR ALTERATIONS, REPAIRS OR ADDITIONS
REQUIRING A PERMIT OCCUR, OR WHEN ONE OR MORE
SLEEPING RGJMS ARE ADDED OP CREATED IN EXISTING
DWELLINGS. THE DWELLING UNIT SHALL BE PROVIDED
WITH SMOKE ALARMS LOCATED AS REQUIRED FOR NEW
DWELLINGS.
-SMOKE ALARMS SHALL BE INTERCON-
NECTED AND HARD WIRED IN SUCH A
MINNER THAT THE ACTIVATION OF ONE
A. 4<4 WILL ACTIVATE ALL ALARMS.
(b._DROOMS, AREAS APPROACHING
BEDROOMS, VAULTED CEILING
WITH RISE OF 24" & ON EACH FLOOR)
01
EXHAUST FANS
100 CFM kitchen
50 CFM bathrooms
& laundry �w
< tic8,..ST(oal 14-
e cccA-6c)
4 4)(L\
Egress windows openable
5.7 sq. ft. - 44" sill
STAIRWAYS: Minimum width 36 in. with min. tread
run of 10 in., max. rise of 7 3/4 in. & nosing of 3/4-1 1/4 in.
Min. 6 ft. 8 in. headroom. Enclosed usable space under
stairways requires 1 hour fire protection of in. GWB
2'
•
,. :. .
'; , .... ,..
-, PROVIDE DIAGRAMS AND
EN-elINEERING LAYOUTS FOR
ROI:, TRUSSES. BEAMS AND
F1_001-3 SYSTEMS PRIOR TO FRAMING
INT:,C:TI,.,0::N S
CITY COPY
• ,
-,
. . ,
THIS BUILDING SUBJECT
TO FIELD INSPECTION CORRECTIONS
9§4%;
("OhliPLIANCE
.......4
WASHINGTON STATE ENERGY CODE
TABLE 6-2
PRESCRIPTIVE REQUIREMENT S°" FOR GROUP R OCCUPANCY
CLIMATE ZONE 2
Wall12 Wall• Wall• Slab6
Glazing Glazin U-Factor s a a
Area10: Door Ceiling2 Vaulted Above int ext Floors on
Option % ll U-Factor Ceiling Grade Below Below Grade
of Floor Vertical Overhead Grade Grade _
I. 12% 0.35 0.58 0.20 R-38 R-30 R-21 R-21 R-12 R-30 R-10
int
II.* 15% 0.35 0.58 0.20 R-38 R-30 R-19+ R-21 R-12 R-30 R-10
R-58
III. 17% 0.32 0.58 0.20 R-38 R-30 R-19+ R-21 R-12 R-30 R-10
R-58
IV. 25% 0.35 0.58 0.20 R-38/ R-30/ R-21 R-15 R-12 R-30/ R-10/
Group R-1 U=0.031 U=0.034 int" / U=0.029 F=0.54
and R-2 U=0.054
Occupancies
Only
V. Unlimited 0.35 0.58 0.20 R-38 R-30 R-19+ R-21 R-12 R-30 R-10
Group R-3 R-58
and R-4
Occupancies
Only
VI. Unlimited 0.30 0.58 0.20 R-49 or R-38 R-21 R-21 R-12 R-30 R-10
Group R-3 R-38 Adv int?
and R-4
Occupancies
Only
VII. Unlimited 0.32 0.58 0.20 R-38/ R-30/ R-21 R-15 R-12 R-30/ R-10/
Group R-1 U=0.031 U=0.034 int' / U=0.029 F=0.54
and R-2 U=0.054
Occupancies
Only
* Reference Case
0. Nominal R-values are for wood frame assemblies only or assemblies built in accordance with Section 601.1.
1. Minimum requirements for each option listed. For example,if a proposed design has a glazing ratio to the conditioned floor area
of 13%,it shall comply with all of the requirements of the 15%glazing option(or higher). Proposed designs which cannot meet the
specific requirements of a listed option above may calculate compliance by Chapters 4 or 5 of this Code.
2. Requirement applies to all ceilings except single rafter or joist vaulted ceilings complying with note 3. 'Adv'denotes Advanced
Framed Ceiling.
3. Requirement applicable only to single rafter or joist vaulted ceilings where both(a)the distance between the top of the ceiling
and the underside of the roof sheathing is less than 12 inches and(b)there is a minimum 1-inch vented airspace above the insulation.
Other single rafter or joist vaulted ceilings shall comply with the"ceiling"requirements.This option is limited to 500 square feet of
ceiling area for any one dwelling unit.
4. Below grade walls shall be insulated either on the exterior to a minimum level of R-12,or on the interior to the same level as
walls above grade. Exterior insulation installed on below grade walls shall be a water resistant material,manufactured for its
intended use,and installed according to the manufacturer's specifications. See Section 602.2.
5. Floors over crawl spaces or exposed to ambient air conditions.
6. Required slab perimeter insulation shall be a water resistant material,manufactured for its intended use,and installed according
to manufacturer's specifications. See Section 602.4.
7. Int.denotes standard framing 16 inches on center with headers insulated with a minimum of R-10 insulation.
8. This wall insulation requirement denotes R-19 wall cavity insulation plus R-5 foam sheathing.
9. Doors,including all fire doors,shall be assigned default U-factors from Table 10-6C.
10. Where a maximum glazing area is listed,the total glazing area(combined vertical plus overhead)as a percent of gross
conditioned floor area shall be less than or equal to that value. Overhead glazing with U-factor of U=0.40 or less is not included in
glazing area limitations.
11. Overhead glazing shall have U-factors determined in accordance with NFRC 100 or as specified in Section 502.1.5.
12. Log and solid timber walls with a minimum average thickness of 3.5" are exempt from this insulation requirement.
34 Effective July 1,2007
, _
GUIDELINES
Installation of Smoke Alarms in
Existing One- and Two-Family Dwellings
The Spokane Regional Code Group smoke alarms according to Section R313.1.1.
has determined the need to clarify
application of requirements as it applies to DISCUSSION: If a kitchen were being
smoke alarms within one-and two-family remodeled on a rancher style house, and the
dwellings undergoing repairs, alterations, attic were open such that all other rooms were
or additions. accessible via the attic, then hardwired, inter
connected smoke alarms would be required
Section R313.1.1 Alterations, throughout the house in required locations,
repairs, and additions. powered from an existing circuit.Additionally, if
When interior alterations, repairs, or the same home contained a basement, and
additions requiring permits occur, or wiring could be routed through an open kitchen
when one or more sleeping rooms are wall, then the basement smoke alarm would
added or created in existing dwellings, also be required to be interconnected with the
the individual dwelling unit shall be upstairs alarms.
provided with smoke alarms located as
required for new dwellings; the smoke 2) REPAIRS: New smoke alarms are NOT required
alarms shall be interconnected and hard to be added when repairs are performed such
wired. as: replacing water heaters, boilers, gas inserts,
electrical service equipment, sprinkler systems or
1) ALTERATIONS: New smoke alarms their interior components, miscellaneous
are NOT required to be added if, for plumbing repairs, etc., or minor structural repairs
example: a plumbing system is such as replacing a deteriorated structural
altered, converting drains to ABS, an support. Major structural repairs occurring from
electrical system is altered by fire damage,tree falling through roof, lighting
replacing the fuse panel with a circuit strikes etc.,WOULD require the smoke alarms
breaker panel, a circuit is altered by to be upgraded according to Section R313.1.1.
extending it or converting it from one
voltage to another, windows are 3) ADDITIONS: This section seems to be fairly
changed from wood frame to vinyl, self-explanatory in that additions which
etc. affect the actual structure of the building would
require smoke alarms according to Section
Major alterations like removing or adding R313.1.1. It may be possible that an attached
structural members, remodeling a garage addition with no disturbance to the
bathroom, or remodeling a kitchen existing structure would NOT trigger the
(finished materials removed and framing smoke alarm requirement. Repairs to exterior
is exposed),are examples which surfaces of dwellings are exempt from the
WOULD trigger the requirements for requirements of this section.
,
I: :Alrnl, .tbe City of S� �4.4vL A L 4.i.q'Ys`
i
f.m%
:;;4,::II , Spokane _� re--.1
Zr0l�y Park
hene
S(� �7� ry�m l l off
PoKnrf Could I t-s� ..i 1,> ,�,1}1 �SN1NaS
CONSENSUS OPINION: Hardwired For more information contact the local code
interconnection of smoke detectors enforcement agency:
would not be required between floors or
areas which would require the boring of • Spokane County — (509) 477-3675
structural members within enclosed wall • City of Spokane — (509) 625-6100
or floor assemblies. If however, an open • City of Spokane Valley— (509) 688-0036
chase exists for ductwork or plumbing, • City of Liberty Lake - (509) 755-6700
and provides a readily accessible means • City of Medical Lake - (509) 565-5000
for fishing wiring (alongside ductwork or • City of Cheney (509) - 498-9237
plumbing) from floor to floor or other • City of Deer Park — (509) 276-8802
areas, the smoke alarms could • City of Fairfield — (509) 477-3675
practicably be installed/ hardwired/ • Town of Spangle — (509) 477-3675
interconnected. The removal or • Town of Millwood — (509) 477-3675
rearrangement of insulation is NOT
considered removal of finished material.
NOTE: Areas not accessible for
hardwiring would still require battery
operated smoke alarms.
•
Please note that while every effort is made to assure the accruacy of the information contained in this brochure it is not warranted for
accuracy. This document is not intended to address all aspects or regulatory requirements for a project and should serve as a starting
point for your investigation. For detailed information on a particular project,permit,or code requirement refer directly to applicable file
and/or code/regulatory documents or contact the appropriate division or staff.