1974, 06-24 Permit App: K5039 Duplex County of Spokane, Washington
BUILDING CODES DEPARTMENT, COURTHOUSE, SPOKANE, WASHINGTON 99201
APPLICATION FOR LAND USE OR STRUCTURE PERMIT'))_
GENERAL REQUIREMENTS PERMIT FEE
PERMIT REQUIRED. A land use or structure permit is required by County Resolution to erect a building or structure of any
kind or alter any building or structure already erected, or to change a land use. Construction must conform with the
Spokane County Building Code and Zoning Ordinance. Construction is subject to inspection.
'!ATKR. Water supply must be approved by the County and State Health Departments. Where work on water connections disturbs
he surface, shoulders or ditches of County Roads, permission must be obtained from the County Engineer's Office.
SEWAGE SYSTEM. Permits are required in all cases by County Resolutions Nos. 45-133 and 47.235.
CET-BACK FROM PROPERTY LINES. In most zones and under most circumstances, a set-back from the front property line, of at
least 25' is required, a 5' side yard, 15' side yard from a flanking street, and a 25' rear yard are required.
STATE HIGHWAYS. Where the structure abuts a State Highway, clearance must be obtained pertaining to set-back and ingress
and egress.
COUNTY ROADS. Work on street right-of-way may not be performed until staked by County Road Department and work must be
performed in accordance with stakes. Points of ingress and egress must be approved by the County Engineer.
MOVING OF BUILDINGS. A permit is required to move an existing building. When a building is moved on a County or State
Highway, clearance must be obtained from the County Engineer and/or State Highway Department.
ACCESSORY BUILDINGS. Accessory buildings (garages, sheds, etc.) require a separate permit.
RESTRICTIVE COVENANTS. Builders should check provisions of covenants or dedications and easements running with the land
which are enforceable through civil action. County Officials can not bring action to enforce covenants or dedications.
APPLICANT FILL IN BELOW THIS LINE
vvilliam C . �'• F 8015 Upriver D926-5372
Name of Owner Gober Address r. phone
Architect Phone Engineer _ Phone
Contractor Fourkays Const. Co. Address P. 0. Box 7856, Cpokane phon`Jee 487-6570
Leal Description..of Property (Give complete escription from dee•, tax receipt, etc.) ?L e5 7 .5----y 3 i0,----'7,2
i(gKnown as i . 11302 Portland) ,/J C j /�) - y
4,,,L__.._��-`� -. , %f r 'e /L _- e,' _.. /o2 _i' _/ (3 -- / z) 2
C/`l 3�/l�
ES PTIO F WORK:New Addition Remodel Moving Bldg.Zone / —Fire Zone 5
Size of Lot Sewage System Stories 1
ConstFrame Dimensions 52 ' x 22 ' Total Sq. Ft. 1144 Valuation $2, 500.00
(Frame,concrete,brick etc.)
Rooms 8 Baths Basement O n e Foundation Const. Concrete Chimney M as o nryireplace NNon e
.(Full, part, none) , ( d) (N er)
F.A.C1_1 Composition Asbestos Shin gl( Gyp. ` .
Heat. System__ Type of Roofing Ext. Finish Int. fa.11 Finish
Use of Bldg. !W0 Family Residence No. of Units 2 Bedrooms 4
Garage or Carport Attached two Attached Carports Pri rate haat hed
Remodeling restricted to Bathroom and Kitchen o ' one Half of Duplex.
PLOT PLAN
Draw sketch with dimensions showing: (1) property lines; (2) street or road locations; (3) location of existing and
proposed buildings; (4) distance to property lines and streets; (5) dimensions of buildings; (6) location of sewage sys-
tee.anter supply lines.
y �(,i' NORTH i�`�i" �" State License No.
2230112508
-- ���`\"D Ino. Ins. Acct. No.
J 287, 644
v REQUIRED
11-----�,2,' �i Plumbing Permi �.v/�-�
C n+ Heating Permit
to . . G 9' 4n. Sewage Permit
Plans Received
Plans Checked
Plans Returned
Plans Picked Up
Plans Mailed