Loading...
1994, 03-28 Permit App: 94002479 ResidencePROJECT NUMBER= 94002479 APPLICA,TION,, ****** THIS IS NOT A PERMI'kr,(v ' PENALTIES WILL BE ASSESSED FOR COMMENCING WORK WITHOUT A PERMIT -DATE= 03/',8/94 SITE STREET= 2011 S SONORA ST ADDRESS= VERADALE WA 99037 PERMIT USE= RESIDENCE W/GARAGE (F.A. GAS) PLAT#= BLOCK= AREA= # OF BLDGS= 005277 5 00011926 1 # PLAT NAME= LOT= F/A= DWELLINGS= OWNER= DOUGLASS, HARLEY STREET= 815 E ROSEWOOD ADDRESS= SPOKANE WA 99208 ****** PARCEL#= 45252.0501 RIDGEMONT ESTATES 1 ZONE= UR -3.5 F WIDTH= 68 1 WATER DIST CONTACT NAME= HARLEY DOUGLASS BUILDING SETBACKS: FRONT= 31 LEFT= 10 AGE= 01 NORTH 2ND AD DIST#= F DEPTH= 105 R/W= 50 PHONE= 509 994 3013 PHONE NUMBER= 509 487 9792 RIGHT= 37 REAR= 60 ****************************** REVIEW INFORMATION ***************************** DEPARTMENT BUILDING COMMENTS: BUILDING REVIEW REQUIREMENT PLAN REVIEW REQUIRED 6; <0 SETBACK REVIEW REQUIRED APPROVAL: R BURRIS BUILDING SEWER PERMIT PENDING DATE: 03/25/94 )6 3 -I - 9 APPROVAL: 94-1948/94S-262 - C BRADBURN ENGINEER APPROACH/FLOOD PLAIN/DRAINAGE COMMENTS: 9 **************** ****** DATE: 03/25/ 3/ gaci, ddS. ** BUILDING PE CONTRACTOR= HARLEY C DOUGLASS INC STREET= 815 E ROSEWOOD AVE ADDRESS= SPOKANE WA 99208 NEW= X DWELL UNITS= 1 BLDG W X D= 40 REQ PARKING= REMODEL= OCCUP. LD= X 34 SQ FT= #HANDICAP= ******************************* PHONE= 509 487 9792 ADDITION= CHANGE OF USE= BLDG HGT= 25 STORIES= 2 2860 SPRINKLER= N CRITICAL MAT= N PROJECT NUMBER= 94002479 APPLICATION DATE= 03/28/94 PAGE= 02 DESCRIPTION GROUP TYPE SQ FT VALUATION BASEMENT U R-3 VN 880 9680.00 DECK R-3 VN 120 600.00 GARAGE M-1 VN 400 3200.00 RESIDENCE R-3 VN 880 48400.00 2ND FLOOR R-3 VN 1100 30800.00 ITEM DESCRIPTION QUANTITY FEE AMOUNT RESIDENTIAL VALUATION Y 608.00 STATE SURCHARGE Y 4.50 RADON MONITOR 1 12.57 SALES TAX 1 1.01 RESIDENTIAL SURCHARGE Y 109.44 ******************************* MECHANICAL PERMIT ***************************** CONTRACTOR= COMPLETE HEATING & SHEET METAL PHONE= 509 533 9528 STREET= 1934 E MARSHALL ST ADDRESS= SPOKANE WA 99207 ITEM DESCRIPTION QUANTITY FEE AMOUNT GAS APPLIANCE<=100,000BTU 1 12.00 GAS LOG OR GAS INSERT 1 10.00 GAS WATER HEATER 1 10.00 GAS PIPING 3 3.00 VENTILATING FANS 4 40.00 ***************************** PLUMBING PERMIT ****************************** CONTRACTOR= GOLD SEAL MECHANICAL INC STREET= 5524 E BOONE AVE ADDRESS= SPOKANE WA 99212 ITEM DESCRIPTION PHONE= 509 535 5944 QUANTITY FEE AMOUNT TOILETS/BIDETS 3 18.00 SINKS 4 24.00 DISH WASHERS 1 6.00 CLOTHES WASHER 1 6.00 GARBAGE DISPOSAL 1 6.00 FLOOR DRAINS 1 6.00 WATER USING DEVICES 3 18.00 PERMIT TYPE FEE AMOUNT AMOUNT PAID AMOUNT OWING BUILDING PERMIT 735.52 .00 735.52 MECHANICAL PRMT 75.00 .00 75.00 PLUMBING PERMIT 84.00 .00 84.00 894.52 PROCESSED BY: CAROL BRADBURN PRINTED BY: CAROL BRADBURN .00 894.52 4— DETACH TO DISPLAY CERTIFICATE - - DEPARTMENT OF LABOR AND INDUSTRIES THIS CERTIFIES THAT THE PERSON NAMED HEREON IS REGISTERED AS PROVIDED BY LAW AS A ONST T CON GENERAL REGISTRATION NUMBER EXPIRATION DATE O?/01/s4 O1 . Ft's _LD11OP !FFECTIV= DATE_ LD/05/69 HkRLt Y C DOUGLASS INC E 815 ROSEW000 S'OKA?1E. Ok 92208 STATE OF WASHINGTON F625-052-000 (3-92) • d.:::�� ` : ...�.....R- t DET."CH TO DISPLAY CERTIFICATE _} I HARLEY C. DOUGLASS DO CERTIFY THAT THIS IS A COPY OF MY ORIGINAL CONTRACTORS LICENSE. Si. q - r Harley C. Douglass Date STATE OF WASHINGTON COUNTY OF Spokane 1 certify That 1 know or have satisfactory evidence thrt Harley C. Douglass is the person(s) who appeared he fore mc. and said person(s) acknowledged that 0'c/the/they) sig cd this instrument. on oath stated that (he/she/they) was (were) authori,cd to execute the instrurnc and acknowledged it as the President „ f Marley C. Douglass, Inc. Jo be the free and voluntary act such party for the uses and purposes mentioned in the instrument. Signature otary Public Title OCT. 23, 1996 My appointment expire% Project Information 1 Building Information )11 Contractor Information I APPLICATION WORKSHEET 1l b General Information `Tole a� 1ress 674 - 2-1-17 .7 1'ar c1iiiiltcr Ownc 5-IARLEY C. DOUGLASS, INC. Ma ding address E. 815 ROSEWOOD -City SPOKANE State WA Phone (509)487-9792 ztl, 99208 Site Information Legal Description 7_71 - /3 1 1'roperi stiG12p ize 3,u0� W aTer EZ o pupcstor ithfrijinZ -lumber oI: Ropd�wtdth Dwellings Buildings Permit Use New Addition Remodel Change or -use Dwelling units / Occupant load ;Budding height,- Stories Sprinters m Cid scal Materul Budding dimensions !" X J'I Total square loogq � /7 ,_,y 'Req'd parking handicap parking Square footage breakdown am Boor e so 41 Second floor o 1,100 Finishe b�enient N Uncovered /covered deck Other UnGnabeJ bas ®eni Garage � �JJW Building conlnctor HARLEY C. DOUGLASS, INC. Phone HARLECD110PE 487-9792 Mailing address License number E. 815 ROSEWOOD I(eating and insulation information (it -values) Ilea tsource rlaceiling 8 Vaulted ceiling 30 Below grade wall oor -va ue Floor ow� Iotatwindow area Plumbing contractor Above grade wall Sin &eft r l unuce clhocncy of floor area GOLD SEAL MECHANCIAL License number Phone GOLDSM 290C4 (509)535-5944 Mai nfigadarest E 5524 BOONE -City state ztI SPC��ANE WA 99208 City. state, zip SPOKANE WA 99212 1Icatin coolnclor COMPLETE HEATING & SHEETMETAL License number - Phone 1934 EAST MARSHALL AVE. 533-9528 -:failing address COMPPLHS066CP City. stale. zip SPOKANE WASHINGTON 99207 Other/ Lender License number Phone ai ing a ress City, stale. zip 1tROJEC[' CONTACT' HARLEY DOUGLASS PHONE 487-9792 Spokane County Division of Buildings 1026 West Broadway Ave * Spokane, Wa 99260 * (509) 456-3675 MECHANICAL PERMIT APPLICATION PROJECT' ADDItE•SS: OWNER: HARLEY C. DOUGLASS INC. 1P11ONE•: 502-487-9793 MAILING ADDRESS: 815 EAST ROSEWOOD SPOKANF WASHINGTON 99308 (street) (city/state) (zip) CONTRACTOR: COMPLETE HEATING & SHEETMETAL LICENSE: COMPI HSOfifirp MAILING ADDRESS: 113 PHONE: street (city/state (zip) SIGNATURE: SPOKANE COUNTY DIVISION OF BUILDINGS WEST 1026 BROADWAY AVENUE • SPOKANE, WA 99260 • (509) 456-3675 ` 12ESCRIPTION OF WORK OP UNITS moo sYl /UNIT AMOUNT I302` FUEL BURNING APPLIANCE = or <Ioo,000. $12 _ , ) Z ,lav E30: FUEL BURNING APPLIANCE >loo,000$1S - , 13Q UNLISTED FUEL BURNING APPLIANCE = or <400,000$50 - , 1305< UNLISI"ED FUEL BURNING APPLIANCE >400,000$100 - , .006i USED APPLIANCE (Must meet WSECs min. AFUE rating) Q or <400 p00$50 - , 1307: USED APPLIANCE (Must mctt WSECs min. AFUE rating) >400,000$100 - , 1308: BOILER/REFRIGERATION 1-I00M BTU$12 - , 1309:;. BOILER/REFRIGERATION 101-5ooM [rni. $20 - 131.0. BOILER/REFRIGERATION 501-1,000M BTU. $25 - , 13:1:1:: BOILER/REFRIGERATION 1,001-1,750M BTU. $35 - r. B12' BOILER/REFRIGERATION +1,750M 13TU . $60 - , 313: GAS LOG, GAS INSERT, AND/OR GAS FIREPLACE- $10 - , j Z - '. 11114;: RANGE -• $10 - g 1315:: DRYER -$10 - , 1110 FUEL BURNING WATER HEATER -$10 - , f' b . 03 , 8171 MISCELLANEOUS FUEL BURNING APPLIANCE -$10 - lial GAS PIPING (ca. outlet) -. $1 - , 13`191 DUCT SYSTEMS -$10 _ , 1320. VENTILATING FANS -. $10 - , 137ti AIR HANDLER (DOES NOT include duct systems) Q or <10,030 CI?M$12 - , 0322: AIR HANDLER (DOES NOT include duct systems) >10,000 CFM$15 - , Irni EVAPORATIVE COOLERS -$10 - , I324': TYPE I HOOD -. $50 - , 1325: TYPE II HOOD -$10 - , X.I. HEAT PUMP/AIR CONDITIONER 0-5TOKS$12 - , 1327; AIR CONDITIONER 6-15TONS$20 - , B28 AIR CONDITIONER 16-3OTONS. $25 - , 1329.; AIR CONDITIONER 31-50 TONS$35 _ , 13:30 AIR CONDITIONER +50 TONS560 - , 13'313: LPG STORAGE TANK -$10 - , 1312` WOOD OR PELLET STOVE/INSERT -• $25 - , NO1 E: MIN MUMPERMIT FEE IS $35.00 Subtotal 3'" c PLUS: PROCESSING FEE $25.0 TOTAL PERMIT FEE DUE S S9 . 6 c7 SIGNATURE: SPOKANE COUNTY DIVISION OF BUILDINGS WEST 1026 BROADWAY AVENUE • SPOKANE, WA 99260 • (509) 456-3675 PLUMBING PERMIT APPLICATION ROJECC ADDRESS: WNER: HARLEY C. DOUGLASS INC. PI-IONE: 509-487-9792 AILING ADDRESS: 815 EAST ROSEWOOD SPOKANE WASHINGTON 99208 ONI'RACTOR: GOLD SEAL MECH. (street) (city/state) (zip) LICENSE: GOLDSM 290C4 [AILING ADDRESS: PHONE: 509-535-5944 5524 EAST BOONE SPOKANE WASHINGTON 99212 (street) (city/state) (zip) PLUMBINGZHIX 1 URNS DESCRIPTION I DUTAIL #o1' UNITS MULTI - wen AY ZJS'I /UNIT raIMS AMOUNT )02 TOILETS 303 WATER CLOSET'S. BIDETS $6 URINALS x 304 TUBS BATH, JACUZZI, SPA, GARDEN $6 $6 (v Uo B05 SHOWERS (per trap) OO6 sINKs BASE, STALL, ON—SITE BUILD x $6 $ Oa B07 DISHWASHER LAVS/BASINS. BAR, FLOOR, KITCHEN. LAUNDRY. UTILITY, JANITOR, PHOTO. X—RAY. FOODJPREP/CULINARY/MEAT) x S6 $6 szq_co I'�48 CLOTHES S WASHER x $6 ARBAGE DISPOSAUGRINDER x $6 = $ 6 .0 WATER SOFTENER x $6 =$ 11 ELECTRIC HOT WATER TANKS DU FLOOR DRAINS (NOTE: II pa water task, see stocks Klatt) AREA, CASE, COIL, TRENCH, CONDENSATE x $6 x $6 $ BL3 ROOF DRAINS/OVERFLOW DRAINS (ea.) B14. FOUNTAINS, DRINKING x x $6 $6 1315 WATER PIPING/DRAIN-WASTE-VENT 1316 SEWAGE EJECTORS INSTALLATION, ALTERATION OR RIEPAIR x $6 GRINDER, SUMP PUMP x $6 $ X17 WATER USING DEVICES B18 CROSS -CONNECTION DEVICFS ICE AND/OR COFFEE MAKER, HOSE BIB, STEAMER, PROOFER, CARBONATOR, SWAMP COOLERS VACUUM BREAKER, CIIECK VALVE, AND R.P.B.P.D. FOR: VATS,SUMPS. TANKS, BOILERS, & SPRINKLER SYSTEMS x $6 k9 INTERCEPTORS GREASE TRAP, SAND TRAP, CHEMICAL HOLDING TANK S6 = S6 = 12a MEDICAL GAS (per outlet/bottle station fit MISCELLANEOUS FIXTURES NITROUS. OXYGEN NOTE: MINIMUM PERMIT FEE IS $35.00 SIGNATURE: x X S6 = S6 S Subtotal PLUS: PROCESSING FEE Co $25.00 TOTAL PERMIT FEE DUE s91.op. SPOKANE COUNTY DIVISION OP BUILDINGS WEST 1026 BROADWAY AVENUE • SPOKANE, WA 99260 • (509) 456-3675 c WATTS''N 5.4 1991 WA STATE ENERGY.CODE.COMPLIANCE REPORT 03/03/94 FILE: C:\\WATTDATA\\HD2011SN.WS HOUSE ID: H.DOUGLAS SPEC. 2011 SONORA Site: 2011 SONORA SPOKANE, WA (509 )487-9792 lomeowner: (509 )487-9792 Builder: HARLEY DOUGLAS (509 )487-9792 Analyst: Jurisdiction: Utility: TAS (MARQUESS) SPOKANE COUNTY WWP/VERA House Type: Single Family Floor Area: 2573 ft2 Weather Data: Spokane, WA Climate Zone: 2 The PROPOSED design *COMPLIES* with 1991 WA State Energy Code. COMPONENT PERFORMANCE ENERGY BUDGET REFERENCE, 502 9.36 PROPOSED 499. Btu/hr-F 10.06 kWh/ft2-yr REFERENCE DESIGN Component Reference Value X Area = UA BG Wall 7' BG Slab 7' Glazing @15% Doors AG Wall Ceiling, Attic Infiltration U-0 .036 F-0.554 U-0 .600 U-0.400 U-0 .062 U-0.031 ACH-0.350 936 33.7 136ft 75.3 386.0 231.6 40.0 16.0 1902 117.9 871 27.0 14671ft3( 88.8) Reference UA 502 PROPOSED DESIGN COMPONENTS Component Description Value X Area = UA BG Wall BG Slab Glazing @9% Doors RO Uninsulated 7' depth **2 glaze vinyl 3/4" w/ low E **Max. U -value sliding patio Metal 1-3/4" urethane flush **Metal Insul, w/ Raised Panel U-0 .185 F-0 .434 U-0.440 U-0 .520 U-0.140 U-0 .220 936 173.2 136ft 59.0 206.8 91.0 35.0 18.2 19.0 2.7 21.0 4.6 Items in parentheses not included in COMPONENT PERFORMANCE totals. ** Denotes non-standard values - check calculation of thermal value. Page 1 WA1TSUN 5.4 1991 WA STATE ENERGY:CODE COMPLIANCE REPORT 03/03/94 FILE: C,:\\WATTDATA\\HD2011SN.WS HOUSE ID: H.DOUGLAS SPEC. 2011 SONORA AG Wall Skylights @ Ceiling Infiltration Struc Mass R19 INT Lap Wood 2G1 Alum w/TB 1/2" w/low-E R38 blown Attic STD baffled Standard Air Sealing Light Frame. Sheetrock walls **Slab w/ no cover U-0 .058 U-0.640 U-0 .031 ACH-0.350 2046 118.7 8.0 5.1 863 26.8 14671ft3 ( 88.8) Proposed UA M- 3.000 1726 M-10.000 847 499 5178 8470 HEATING/COOLING/VENTILATING SYSTEMS Heating System Type: Make: System Efficiency: Modified Efficiency: Design ACH: Design Load(at 66F dt): Duct Losses(% Dsn Load): Total Load: System Size: Average Annual Heat: Annual Cost: Ventilation System: Cooling System: SEER: Cooling Load(at 12F dt) : System Size(%Over ) : Annual Cool Requirement: Solar Access: PROPOSED Gas Furnace DEFAULT 78 % 74 0.60 44003 0 44003 66000 Btu/hr Btu/hr( 0%) Btu/hr Btu/hr (150%) 115 MBtu 643 Integrated Spot & Whole House 0.0 (Unducted) 22011 Btu/hr 2.5 tons( @125% ) *** kWh/yr Partially Shaded PROPOSED DUCT SYSTEM SUPPLY RETURN Location Avg Rvalue Surface Area A11 in heated space All in heated space Page 2 WA1T='N 5.4 1991 WA STATE ENERGY LODE:COMPLIANCE REPORT 03/03/94 FILE C:\\WATTDATA\\HD2011SN.WS HOUSE ID: H.DOUGLAS SPEC:. 2011 SONORA GLAZING ORIENTATION PROPOSED PROPOSED South ft2 North ft2 Southeast : Northwest : Fast 159.8 West 82.4 Northeast : Southwest Economic and energy consumption estimates are designed for comparative purposes only. Actual cost for heating will vary depending on weather conditions, occupant lifestyle and other factors. Page 3 --- `5ingit Gari U.Drywwe I type'A with My1ol f r & Gro '. J yp' "No. 3 Spokane C93..tu1t3%=Srtondard, Sta.23+ 70 ? l=vf` Sonora Street op of Crate 2022.50 See Detail "A" -Bottom of Pond Floor Elev. 2022.00 Floor Arco 676 sglt See Detail "A- Curb Drop. 7" Dee tr Sta. 23+52 _.o ?3+57 RT S9.1:14,-cr"S1., with Concrete `Curb Inlet, Type 1, L=5' Spokane County Standard opening 23+54.5 F.L. 2022.91 See Detail "A" 28x34' Drainage Easement = 90'0 '00" R = 20.00 —�/ T = 20.00' N\ L = 31.42. Garb Line ^� u+ 1 0 CP OD 2'u r c. S LOT 1 BLOCK 5 RIDGE TONT ESTATES NORTH 2ND ADDITION AUGUST 31, 1993 GRAPHIC SCALE (IN FEET) 0 10 20 qp 1" = 20' 1 fowww Ipa4 Virnpson Engineers, Inc. CIVIL ENGINEERS & LAND SURVEYOR; N.909 ARCOUNC ROAD SI'01(ANC. WA 99212 PM 9?6- 13??