Loading...
2004, 07-19 Permit App: BLD-04-07099 Residence rt rcMI I /U'I'LI(:A .)N_WORIt SHEET SPOKANE VALLEY 00k. "NITYDEVELOPMENT BUILDING DIVISION 11707 East Sprague Ave Ste 100 Spokane Valley, WA 99206 Phone: 509)688-0036 Fax. 509)688-0037 rv� R1, REQUIRED SITE INFORMATION STREET ADDRESS: 14614 E Queen ASSESSOR'S TAX PARCEL NUMBER(S): 46353.4304 LEGAL DISCRIPTION: Lt 4 BIk 22 Summerfield East 5th Addition PERMIT DESCRIPTION: Residential Construction (i11IT.1)ING PERMIT f]CHANGE IN USE []GRADING ['MANUFACTURED HOME []RELOCATION n SIGN l TENANT fl OTHER --- - - --------- __ OWNER / APPLICANT INFORMATION 1OWNER; Harley C Douglass Inc _ APPLICANT: PHONE: 1187-9792 FAX: 1187-1580 PHONE: FAX: ADDRESS 8510 N Crestline Ste_A-Spokane_ 99217ADDREss: CITY,STATE,ZIP o CITY,STATE,ZIP CONTRACTOR: ARCHITECT . ' �°°1 ANE VALLEY BUI FLIANCE • PHONE: FAX; PIIONE:_ 1�jG DIVISION ADDRESS: ADDRESS: = CITY,STATE,ZIP - • STATE,ZIP WA ST CONTRACTOR LICENSE# HA R LEC D .1 10 PE CONTACT: (� l 11) _1J--------�) PERMIT/BUILDING INFORMArt N 9 .\ 5111 COST OF PROJECT: 30%SLOPES ON PROPERTY: 't;► tl FT: 1258___ 9UILDING HEIGHT TO PEAK: 35 OCCUPANCY GROUP: o 2ND FLOOR SQ FT: 31JILDING DIMENSIONS: 39 X 54 CONSTRUCTION TYPE: UNFIN BASEMENT: 1250 DUMBER OF STORIES: 1 1 /2 STRUCTURES ON PROPERTY: FINISHED BASEMENT: DUMBER of BEDROOMS: 3 CRITICAL AREAS: GARAGE: 400 'LANKING SETBACK: CURRENT PROPERTY SIZE:I.* V g3./ COVERED DECK:_ RONT SETBACK: 0?3CURRENT PROPERTY USE: DECK: 120 :EAR SETBACK: CURRENT SEPTIC USE: EFT SETBACK: _ 3 CURRENT WELL USE: TIGHT SETBACK: 3 IMPERVIOUS SURFACE AREA:_ wiu III: I.LNb III: _ SQ FT OF SIGN:_ I IEIGI IT OF SIGN:__.____-_ YEAR: PIT SET:_ ..4 OF SIGNS: _ AREA OF EXIST SIGN; MANUFACTURER:_ TYPE OF SIGN: RELOCATION FIRE SAFETY INIKOMItir PREVIOUS ADDRESS: — FIRE SPRINKLER: FIRE ALARM; __ _____ PAINT BOOTI I: TENT: PROPOSED USE: FIREWORKS DISPLAY: BLASTING: DATE/TIME: WA STATE NON-RESIDENTIAL ENERGY CODE PLANS EXAMINER: PHONE: _— FAX: ADDRESS:_ CITY,STATE,ZIP INSPECTOR: — PHONE: FAX: ADDRESS: CITY,STATE,ZIP SPECIAL INSPECTIONS ri BOLTING 000NCRETE LI REINFORCEMENT n WELDING 'IRM NAME: _ PHONE: FAX: NSPECTOR(S):____ BUILDING STAFF USE ONLY 3 PUBLIC SEWER AVAILABLE: YES NO IF YES: ci COUNTY n CITY L I PUBLIC WATER AVAILABLE: YES NO IF YES,WHICI I WATER DIST/IRR: i PROPERTY LOCATED WITHIN DESIGNATED STORMWATER CONTROL AREA: LI YES 0 NO i THE PROPERTY LOCATED WITHIN ASA: YES NO PSSA: C] YES [l NO r, , STAFF: - I - AIETHOD OF PAYMENT: n 1111111111111111111 VISA I CASH CHECK r ,LSc�t BANK CARD#' EXPIRES: V/N# AUTHORIZED S/C3NATURE.• • 'FAXED PERMIT APPLICATIONS WILL ONLY BE ACCEPTED WITH MAJOR BANKCARD -Mechanical. Permit , )plication PROJECT PERMIT -- ADDRESS: 14614 E Queen USE: Residential Construction OWMMMER: Harley C Douglass Inc PHONEa timeContact) -- MAILING ADDRESS: m Y ) 1187-9792 8510 N Crestline Ste A Spokane, WA 99217 • (street) (city/state) (ZIP) CONTRACTOR; LICENSE I: Dan_car Mechanical DANCAM102207 MAILING ADDRESS; PHONE 4; 311 N Hodges • Green Acres WA 99016 (street) (city/slate) (ZIP) . • DESCRIPTTONOF WORK I OF UNITS X COST EQUALS AMOUNT 1 E11EI.BURNING APPLIANCE -OR<100,000 . 1 x f1s - 15.00 2 FUEL BURNING APPLIANCE >100,000 X $19 3 UNLISTED APPLIANCE(ADDITIONAL FEE) -OR<400,000 • X 150 - • 1 UNLISTED APPLIANCE(ADDITIONAL FEE) >100,000 • X 1100 . - S USED APPLIANCE(WSEC caln.AFIJE callus) -or<400,000 X 150 . I (/SED APPLIANCE(1VSEC min.AFIIE rating) >400,000 X 1100 . 7 BOR.ER/REFRIGERATION 1.1001(BTU X $15 - 1 00ILER/REFRIGERATION 101-500M 13T11 'X $2B - • 9 BOILER/REFRIGERATION 501-1,00014 11T11 X 139 - II BOR-ER/REFRIGERATION 1001-1,75014 BTTJ X $57 11 BOILER/REFRIGERATION *175014 BTU X $95 ' - 12 GAS LOG,GAS INSERT,GAS FIREPLACE . - 1 X 110 - 10.00 13 RANGE - X $10 - • H DRYER - X $10 - 15 FUEL.BURNING WATER HEATER - 1 X • $10 - 10.60 16 hfSC.FUEL.BURNING APPL. • - X 110 - 17 GAS PIPING(ea.outlet) - 2 x 11 - 2.00 l6 DUCT SYSTEMS - • X $10 .. 19 VENTILATING FANS - 2 x $10 20.00 20 AIR I IANDLER(DOES NOT Include ducting) -OR<10,000CFM X $12 - 21 AIR HANDLER(DOES NOT Include ducting) >10,000 CFM X $19 - • 22 EVAPORATIVE COOLERS - X. 110 - . • 23 TYPE 1 HOOD - X 150 - 21 TYPE 11110013 - X 110 - • 25 IIEAT PUMP/AIR CONDITIONER 0-3 TON • X $12 . . 26 AIR CONDITIONER 3-15 TON X $20 - 27 AIR CONDITIONER 15-30TON X 125 - 2B AIR CONDITIONER 30-50 TON X $35 - 29 AIR CONDITIONER *50 TON' • X 160 - 30 LPG STORAGE TANK - X *10 - 31 WOOD OR PEI-LET STOVE/INSERT - X $10 32 WOOD STOVE-FREE STANDING - X $25 . • • SUBTOTAL; D OP PAYMENT PLUS PROCESSING FEE; $35.00 1114.15: � • TOTAL.PERMIT FEE DUE; • 0 CHECK ❑ Ill _ '::c;:•.• EXPIRES: • RD NUMBER: IZED SIGNATURE: t1 P1iimbbing Permit App. .ration PROJECT PERMIT ADDRESS: 14614 E Queen USE: Residential Construction OWNER; Harley C Douglass Inc PIIONE(Daylirne Contact): 1111/-9/92 IAA WING ADDRESS: 8510 N Crestline Ste A Spokane, WA 99217 (street) (city/state) (ZIP) Cot.JT�ACr LICENSE I: C11 Gold igeaI Mechanical GOLDSM 290 • MA FLING ADDRESS: PHONE I: 5524 E Boone Spokane, WA 99212 53..5 .9II4 (street) (city/state) (ZIP) PLUMBING FIXTURES DESCRIPTION DETAILS I OF ITNTTS X COST EQIIAIS AMOIINT 1-TOILETS WATER CLOSET,BIDETS 2 X $6 - 12.00 2 DRINA'S X $6 - • 3 TUBS 2 X $6 . - 12.00 4 SI TONERS(PER TRAP) BATIL,STALL,ON-SITE BUILT 2 X $6 • ' 12.00 5 SINKS LAVS/BASINS,BAR,FLOOR,KITCIUEN, • LAUNDRY,UTILITY,JANITOR,P11010,X- •3 X j6 - .1 8.00 RAY,FOOD,PREP/CULINA RY/MEAT - • 6 DISIIWASIIER • 1 X • $6 - 6.00 7 CLOTHES WAST LER • X • 46 - 8 GARBAGE DISPOSAL X $6 - • • 9 WATER SOFTENER X $6 - 10 ELECT 110T WATER TA_NI NOTE:IF GAS,SEE MECI IANICAI. • . X • $6 - 11 FLOOR DRAINS AREA,CASE,COIL,TRENCI I,CONDENSATE 1 X ' 46 - 6.00 12 FOUNTAINS,DRINKING X $6 - 13 WATER PIPING/DRAIN-IN INSTALLATION,ALTERATION,REPAIR, • WASTE,VENT,I'LIIMBING. REVERSALS X ;6 • - REVERSAI. . 14 SEWAGE EJECTOR GRINDER,SUMP PUMP •X $6 - 15 WATER USING DEVICE ICE AND/OR COFFEE MAKER,t10SE BIB, STEAMER,PROOFER,CARBONATOR, X $6 • - . . SWAMP COOLER 16 CROSS CONNECTION DEVICE VAGUUM BREAKER,CHECK VALVE,AND X - R.P.B.P.D.FOR;VATS,TANKS,BOILERS - 17 SPRINKLER SYSTEM X $25 - 18 INTERCEPTORS GREASE TRAP,SAND TRAP,CI IEMICAL • X i6 - HOLDING TANK • 19 MEDICAL GASper outlet NITROUS,OXYGEN X $6 - 20 MISC.PLUMBING FIXTURE • X $6 - SUBTOTAL: PAYMENT • t4��at ` .monsein - . TOTAL.PERMIT FEE DOE; EXPIRES: 11411 ER: SIGNATURE: , • 11 -3-2003 11: 13 FROM:TAS-Pi 'CS 5093254587 1:4871580 P:2/9 TAS Technical Assistance Services Garden Court Building.222 W.Mission Avenue, Suite 235,Spokane,WA 99201 (509)325-4476 FAX(509)325-4587 0 .4,/03/03 Project : Single Family Residence ("1358 Split") Total Area: 2282 sq. ft . Address; 14614 E Queen Contractor/Phone: Harley C. Douglass, Inc./ 487-9792 Heating Type: Gas PROJECT COMPLIES with TABLE 5-1/ TARGET COMPONENT VALUES FOR GROUP R OCCUPANCY, 2000 Washington State Energy Code--07/01/02 Amendments. ALLOWABLE HEAT LOSS (Btu/h/deg.F) Glazing: 15% 2282 sq. ft . = 342 .3 @ U .40 136 .9 Doors: 40 sq. ft. U .20 = 8 .0 Ceiling (Attic) : 1356 sq.ft. R38 @ U .031 = 42 .0 Walls (2348 gross sq.ft . ) : 1966 sq.ft. R19 U .062 = 121. 9 Floor: 390 sq.ft . R30 U .029 - 11. 3 BG Walls (3 .5' depth) : 329 sq.ft. R19 @ U .041 = 13 .5 110 l .f . Q F-value . 64 = 70 .4 TOTAL UA ALLOWABLE 404 .0 PROPOSED HEAT LOSS (Btu/h/deg.F) Glazing (11.30) :222 .3 sq.ft.Vinyl @ .50 U* = 111.2 35 sq. ft . vinyl patio @ U .49* = 17 .2 Doors : 40 sq.ft . mtl insul Panel @ .17 U = 6 .8 Ceiling: 702 sq. ft . 6 :12 R38 STD Q .029 U = 20 .4 654 sq. ft . 6 :12/3 :12 R38 STD scissor @ U .031= 20 .3 Walls : 382 sq. ft . R19 INT horiz . siding @ .058 U = 22 .2 1669 sg. ft .. 1219 INT T1-11 @ .061 U = 101 . 8 r^0P-J-2003 11:13 FROM:TAS-P1 'CS 5093254587 TO:4871580 Floor: 390 sq.ft. R30 © .029 U = 11 .3 BG Walls (3 .5' depth) : 329 sq.ft . R11 @ .062 U = 20 .4 110 1 .f . @ F--value . 63 = 69 .3 * Window Products NFRC values TOTAL PROPOSED HEAT LOSS = 400 .9 400 .9 Btu/h < 404 .0 Btu/h -- Project complies w/ Table 5 .1 Edward R. Fielder A A' Technical/Assistant- Services Excerpts from Spokane Valley Standards (1.24, and details A8 and A-8a): • • Every driveway approach must provide access to an off road parking area located on private property. The driveway shall be of sufficient length so a vehicle in the driveway does not project into the road right of way, sidewalk, or pathway. . • Public or private driveways in industrial, commercial, multiple family, church or any like use shall be constructed to allow vehicles to exit without backing onto a public road. • Driveway approaches shall be constructed to avoid interference with existing . drainage inlets, culverts, road lighting standards, utility poles, traffic regulating devices, fire hydrants or other public utilities. The applicant shall bear the cost of relocating any such public facility. • Driveway approach grades within the right of way shall not exceed 8% in urban area, or 2% in rural areas. Driveway grades shall not exceed 10% within ten feet of • a city right of way. See Standards for a mote complete listing of requirements. gIII N iiiCI 111 �—r— Ell . 0r - or _ aim • I 4, t V sh . 1 . \ 3 . : ..13. . I iiii ÷ , .,,. . t 'i A o* 1. I1. b o .• .L.,;E r ,. b . ,„.:4 < 1 -,- ,,, 1 .i el g Ii• W epi III r 1 — i _ _ 1____ j—.E til , f § E .•L1 !di • ' ----vi- t 1_------ 0 --i— tc: . ii ft D a � '/'...,,t, w o o a I l7 ..;t, • 1P Krvi ` 0 r w wL Ic ' _ 1 6 1 �d a 8 1 :. I b ` I m z • ice • 1 • S- i I Ls— • .. �- W 14 01► S Ila w _ ..C�3:1 S�°e�lr�a.p��� r.�f,;:,"1:-''1,.!,,,: r . 5$a0 all° Aillikillii. rah Aillill �1 a"`°r ��"�+� ' 'ti -it �4,,' " � ,� li e.1 lt-114atua`" - 4,44oat"�4 :;: 11 '� �''� £5 - STA: 14 4 - — — S S J� Ela TOGS 2 �.17.831 , _\ _ _ S V1/ WS --- r 7 %S l ; -1 ' B L S - \ I t sf � � 10 , 16 sf o a o v' _ V I 1 1 L 69. 9 ' L _ _ _ 01% h1I9 OO IN C 10 f,xS L66 I11S3>1YM 0.3N'N 0 d)Il58OdS 60NI SW191100 0 A1d11N ____---Y SCALE: 1 "=20' Sheet LOT LOT 4 — BLOCK 22 Date 6-30-04 USKHE. 14614 QUEEN Drawn ZCS4 LOCATION Checked JNL. Engineering • Lond Surveying SUMMERFIELD EAST 5TH ADDITION Planning • Materials Testing Home Builder Harley C. Douglass Inc. Spokane , Washington (509) 487-9792 August 13, 2004 City of Spokane Valley 11707 E Sprague Ave Suite 106 Spokane Valley, WA 99206 Attn: Building Department The footing and walls will be poured in compliance to IRC Section R403 Footings, R403.1 General and R403.1.1 Minimum size. The footing will measure 12" X 6" and the walls will measure 6" in thickness. The wall heights are only 42". According to above mention section of the IRC code, with these measurements steel is not required in footing or walls. Backfill from bottom of footing to finish grade with be 3'. We would appreciate approval to resume construction on the following addresses. 5115 N Calvin 01-1 5205 N Calvin CH- /D14, 5222 N Calvin - Ory 14611 E Queen 0-4- 1to 14614 E Queen O i--1 o4'i 14617 E Queen OA- 6`1 Icj 14622E Queen r-'`{- 1{o® 14709E Queen 0-t- 1 to3 14712E Queen 01- 1645 14720 E Queen o-1- 1I0 a Sincerely, 4 . -wolf - idik4 .<APOEKAN � *'E COMPLIANCE 'OE IVISION Debra Lund Office Manager r Cc:job files 8510 N. Crestline Street Suite A Spokane, WA 99217 Voice: (509)487-9792 Fax: (509)487-1580