Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
1992, 03-10 Permit App: 92001421 Residence
SPOKANE COUNTNT 6F—BUILDINGS W. 130 WAY AVENUE SPOKANE, WASHINGTON 99260 (509)456-3675 ' I certify that I have examined this permit/application, state that the information contained in it and submitted by me or my agent to compile said permit/application is true and correct, and authorize Spokane County to proceed with processing. In addition, I have read and understand the INSPECTION REQUIREMENTS/NOTICE provisions included herein and agree to comply with same. All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. I understand that the issuance of this permit/application and any subsequent inspection approvals or Certificates of Occupancy shall not be construed to give authority to violate or cancel the provisions of any state or local law regulating construction, oras a warranty of conformance with the provisions of any state or local laws regulating construction. SIGNATURE OF APPLICATION OWNER OR AGENT DATE PROJECT NUMB[::Fs:::: 92001421 rFPF°`k. TC;AT TOr1 DATE= 03/10/92 PACYE= 0 ) ***rikyt. THIS :#:.':i NOT A PERMIT *h;t•)e*a: PEr4!F'1LT:CE W:#:#...I... BE:: ASSESSED Fi:JR C:C?M#"SC"NC.ING WORK WITHOUT A PERMT I' ,.,. - STREET= 11906 E': RATL..#'..AC' AVE': PARC:E::i.C_. 04544—i%!.5 ADDRESS= ,>F'4`il<r'ai`d#.. Wry 99206 PERMIT I..►,':iE:::::: RE::,`.i:#:TlENCE .... ELECTRIC C::f"tTiET HEATERS PLATO- i „:- 00.939 r PLAT NAME= #°:E: v#:::,:i WENT IST ADT)BI...00#t = 3 LOT= 5 'ONE:::::: UR -3.5 Ti 1. S i :n: -: I..I AREA--: #:: ,.�f�:• = #:: WIDTH- DEPTH= #.�,: I, /W:.., ,� 0 Y+: OF :l:{ i... D to S �: n: DWELLINGS= i WATER DIST ._. OWNER- NATIONAL LENDER SERVICES INC PHONE= 509 534 53i4 STREET= 5502 E 3RD AVIi.''. ADDRESS= SPOKANE WA 99212 CONTACT NAME= KEN .._ NATIONAL LENDERIKYIZ PHONE NUMBER= 509 534 504 1::{UILE}IrefG SETBACKS: FRONT- ;_yt} LEFT= 99 # Ti'YHT= i74WSN C8 ie a+: �• �: k •>Ir :+t• �: k• #t• Yt• •)Ir �Jr k: ik •Ni 3t• �i 'Ji• i+:• 3( §(• •Jt �J,; a,,• •�: ��r •Jt• rJ,: •Jt #��' E:. 'a' �: E:: #al #: �'� E' 4.! #-i t'� t•"'s #• .#:.. I a. , 1� ' . �'� �� 9' � �• � �� , . DEPARTMENT N.T. E E:u`:#:E::W COMMENTS APPROVAL COMMENTS ------------------------------ BUILDING PLAN REVIEW REQUIRED s Na[Es ©N-tAtvS Pofl R- ----------------------- BUILDING ----BUI#..D.#.Nt, tiE:.#I:{AI.:# REVIEW FEE:.QU.#.RE"i; _..........._. .. APPROACH/FLOOD ��V(, �1...v .�... �% '., ..ErYC1#EF'ir1,,1-7#Nr;#o�� ft.. .. ._. . ._..._. ..._... .. .....HEALTHtE`T NEW OR ADDITIONAL WASTE WAT'EE'' _..y � �. r�.. 9: N• 9k ?4 Jh iv 'Jt• iC 9t• 9: 9t• )l• •Jt• ;»• 1t• •k• i :• Nt } r )t• 9t• 4k )h $i• 9t• Y: Y: �: 'J:.: 'Jt• BUILDING Pt",i �t:»�r:p:�r�rnxar�;.*yen:»�::».n.:x.aa+Fkr:Jt}:»•rr9e CONTRACTOR= toATisOI`#AI... LENDER SERVICES INC STREET= 5 +:.r C: � :;} E 3RD AV[:. ADDRESS= SPOKANE WA 9902 tiWE::L_L., UNITS- TS i OCC;UP . #._D::::BLDG PHONE= 509 534 504 ADDITION= CHANGE OF US01: SPRINKLER= NCRITICAL MAT= N }t. ..r. •}4..k .},; }t..'». �i �t » ii ri b n J4 ii r: ik N i� N: Yt ii �t k: }i it >'i PLUMBING B .. 1 •! G P L ' �#• " PERMIT::+E •k:- �:• ii }c � it � �t• k: •it ki i!• •�. •� .R. �;• •�, it• •+i• 3r •}+: •n: N:.x..�+: Jr it •;! Yr PHONE -- STREET- UNKNOWN ADDRESS= I..j E• K N O W N WA UNKNOWN PROCESSED BY: WENDEL, GLORIA PRINTED BY: WE..NDEI..., GLORIA M it N ii• .N.. •}i r: )c ii it p: ii it i+: 7+: p ii ii �i k H i� #. A..p, .y;.: .x..»i •i{ h:• THANK YOU i., d •Ji i+: a,..ri #t :ri Ji ?t.:J, .yt..yt..}t. }i y4 i;..le �r, .}{ !t Yi * k 3i..p.:�,::�k }t. �..;t. a,..x..t;..k. r NOTICE It is the responsibility of the permittee, not Spokane County, to see to it that the use described on the front of this permit complies with applicable codes and requirements and that required inspections are requested. Failure to request required inspections and obtain the necessary approvals prior to progressing beyond the point where inspections are required may necessitate removal of certain parts of the construction at the owner's/permittee's expense. At a minimum, the following inspections ARE REQUIRED by County Code: 1. FOOTING — when forms and reinforcement are in place and prior to placement of concrete. NOTE: This inspection includes review of the structure's setbacks from property lines. Minimum setbacks are established by County zoning regulations. Typically, side and rear yard setbacks are measured from property lines, while setbacks for yards abutting streets are measured from the property line or the center line of the roadway right-of-way, whichever provides the greater setback from the center line of the roadway right-of-way. Curb lines and fence lines are not necessarily indicative of property lines. In some residential areas, the County can own as much as 20 feet of right-of-way between your property and the actual improved street/curb. The responsibility to comply with applicable setback provisions lies solely with the permittee — neither Spokane County nor its authorized representatives assume any responsibility for the verification or location of your property lines. Please verify their location prior to locating your structure. Failure to properly locate the structure may require its relocation at the owner's/permittee's expense. 2. FOUNDATION—when forms and reinforcement are in place and prior to placement of concrete. (Blocking for a manufactured home is required to be inspected prior to the installation of skirting.) 3. FRAMING — after all framing, bracing and blocking is in place, and prior to concealing. 4. INSULATION — prior to the installation of drywall. 5. PLUMBING — after rough -in, before covering, and final. 6. MECHANICAL — rough -in of piping, before covering, metal chimneys before concealment, and final. 7. FINAL — when complete and prior to occupancy and/or use. Please provide 24 hours notice. NOTE: In addition to inspection of the structure, this inspection includes review of site improvements (typically depicted on the approved site plan) required by ordinance or as a condition of approval of this permit. Items such as the installation of fire hydrants, fire department access, on-site drainage ("208 swales"), road improvements, parking, and landscaping are common requirements of a permit/site plan which must be completed prior to final approval of a building or issurance of a Certificate of Occupancy. In addition to the above any plumbing or mechanical systems or materials which would be concealed by framing, drywall, concrete, etc., must be inspected prior to cover. Check with the department for "special inspections" in conjunction with commercial projects. CALL 456-3675 FOR INSPECTIONS. TO INSURE PROMPT SERVICE, PLEASE GIVE 24 HOUR NOTICE. YOUR INSPECTOR IS UNDER CERTAIN CIRCUMSTANCES, PARTS OF YOUR PROJECT MAY REQUIRE INSPECTIONS FROM OTHER AGENCIES: • road cuts for utilities or drives, State or County Engineer's Office 456-3600 • on-site waste disposal system, Environmental Health District 456-6040 • construction in a flood plain, County Engineer's Office 456-3600 • electrical wiring, State Department of Labor and Industries 456-2792 • sewer connection, County or City Utilities Department 456-3604 EXPIRATION Unless otherwise noted, this permit will be considered null and void by limitation of the work authorized by the permit is not commenced or is stopped for a period of 180 days, unless a written request for an extension of the permit is received and approved by the Building Official prior to expiration. At a minimum an inspection should be requested at least once every 180 days to assure the validity of the permit. A permit may be renewed within one year of the date of expiration for one-half the original fee, subject to certain limitations — please call us if you have any questions. MISTAKES? If you think we've made an error in processing this permit or in conducting inspections pertaining to it, or find erroneous information in the permit, please bring it to our attention immediately by filing a written request for correction within 10 working days of discovery. All such requests should be directed to the Department of Buildings at the address found on the face of this permit. 1 + TEL N0:94582243 #163 P01 _�■ ---� APR -14-192 07:57 I D : HEALTH SP - � 4 � , NATIONAL 1 -1 -'NO -ER SCALL,l I/IalitNGl(�N CGhi(1'11CtOR np*w«ur 1(,W.M �rrie: ja`,UM131;It NriHOLS 1J'I` bu 'LOT PLAN V I4A N•If. Si rW M�KN RAIL I�OAO ftiq' ..,.I .. . ", ., r ... 111 i -.... „ ,iI "I MMI TYI'E or SE rll, : r� Mr.,AL OR ^:, .'IJ I ui"fu',I 15f1,. ...,,� Ttf!'KIl Yufi�ili•. .1IP ?CPTH ron !`!'b:ftJ 11 IiIIS11 1i1 "' '!iI "i i' tU ii'1! i h1 Of SEYIA?.E SlfifJATUAS�— •---t1.4iE...�:_�..� i ��,� tii.,•,,� Ir ��ot� crtir�ul i� ; ,,� I t,fls RV311�1 AG��+Pnlrete MI, IIIc; WHO:: Al (soy) 4604ID40 IVOR TO INS1AU/ HON, t _A._r,% 6w_ KWO-4.1 A•6uir-5 wa V" ltll fi ltS' (or WA. -r role AL -4- �p�7yyAr6 Ass yfIw Pfid tcxlw-fric KIS uo TF+oe(uwlx+Au_T mI jH { orJG lrxtc tc,o�s or 'tnr PAS' ' .r>'.iC cou u'1' o r r 2r � �!� OtJ'L H�IK7 A551L.115, WE "o Ht��' 6►� tt� iLJ (O A 4VW-1JAW< M -I 1 Y �t7KAd.lE a�.tv vo °'�t� As rd-1-�b � z �-+ALL cE vc�ri.Cx Lof�. t) Lori t -s, to -7 1=- 1S, PLOCJL g) Uo' HAW o� wvMLL1Uy uulT, F-)errf a5 1►JDIlIc(�v, X1,.1!" ray a-1 °+,'Y o� of ' ,two sHs11-.++ for jF�+mr 3uecTv,c�sv rte rfi� r r fio>JoL Lo fa CF- lxlL�l{.lGj _A-fr,� wl-fr+afi riL 4ul s) LoT 1, 6LO>,K "I, A> sHONl1 ro SPoko.ue uc+u5 -(o sa v Lir A w� re nAV rUr-rv`�' o -f suu4 _f'" r' A6 'n -W Le ws vv►+IGr+ y 4) Lot zs, pL .K I, At.b Lo'f 10, 6LocIcz, "6"ofw H 'r xHooL.�' I rH oCITNOs't fly a IJD Lo -41.-rY HF' 5) �H IlLJ v W I 6 `� I �JSt.. D wrt'H I u -fH IS AIJ 17 �{F1E IOclt Fi¢L v1'/(Fltf ALJ17 r,4�Y �O(t ", '(ow WILL 6c �v1t7F� 1UGINIGYIA� PON Fab(t� �3C7'l L`k CO' A6 `K kS i°l -fo E&*cH oT �1�` vIRcv I t•.I -rfiG Lc>'1+'tfo~1 7Hpwl] HCK�ol1. i) vnLrj- '�Gi+1GU�S AFE � _ L. �SG esLarc3 6HA.LL,z-o +� 1 ,AE' OF S G 7 fb v11.LJS Ott Y>l� A.f SFbYAal`� Ga.IW-rT HEA�.h{ t715f(GI(f(• 1_k- 5✓r JF.W V_ ". A.LJ ly H,1,ft.11E^ys M,,.1L�cor, 'rs•+E SddD Ov✓t�s He.�/L t'u!'}� f! i A. r7 1976. j - v. G::'. �'y I?7C� �`-�� 6•� A u Ra61-IG 11J AI -•V R7K-'fes ACbv� I.yJ•+1EC� ^ ' i y Ou-tHISi�'�`j 0.4c1 iHl lG f0 {�tE KlJOH/t� �(O 6� (HE ;"� `.o:......'sfatiG A , nc�crrris;' nuv q�� r A.ur� A:xuowi� ,rv1 +� -.64 r7 `�•;• , -�OL15 WHO I,xl`eG[tiG� fGIG Vnt�ilu ALJD iIoj4JCl t f: ROSARY v ; usr� Alan P� VOLGt14-fAitt A1.i AUD R`F-D OF'•-� °��`�1� I �tV Pitt b Flu M�u'no► �a• t.l 1 uuv Awv a mT �- HAS% OF e�hrj�f�S f hlso /� W1Yl 1 • �_ � • =L)2- COUNTY ENGINEER 9 ie J 1`>a�..���cC' a.u^ ,ar�F: •SEL' ,'r 113—.'A'i CSG -. � •Ick'�R r E t •COUNTY PLANNING COMMISSION tv n,uer a..rn 'tFil>l1�th�'Y OF X97a. �eI �' I `� � � Gw.iR�•v.� •.7_rri5' rU ,uy cvnui�s�u•1 .ir..u' 4 3 - -%—'moi` COUNTY TREASURER et0 r tveeesT z0f"rT ,HA el- ALL iA xf�S wr iu � w� lxv�m nuv ��+u� tFtE t.�.ry �+o.v.+ vrr''lU�Mlo ruLLav OQ _rHj> �L—vhr D1� t176. Y P I I I ' J COUNTY ASSESSOR_ CXiVlIIUF17 AIJ� A' 1}-113 Z/ l7/� or` IT 7e. I 1 COUNTY HEALTH DISTRICT OFFICER 1 z / V"T ole c -,V 19 76. I t ��w.nturn quv p�r�ecv><.D 'M1113 —1 — — -4 , 1 COUNTY COMMISSIONERS fF j P(�` f Wb � t L OJ J� ii" T �' y -{M7 17A.`f OF �_Dy 177�10,`y, C'JV/ d - rrKA.s-m laJl+•rk( �N 76. r4.w .p,FFLx� �KA.uE lix.7�•1•?"Y-iF�-sUR�c� Gq�N17�� spo Counter DEPARTMENT OF BUILDING& SAFETY West 1303 Broadway Avenue Spokane, WA 99260 (509) 456-3675 PARCEL NUMBER: STREET ADDRESS :• CITY/STATE/ZIP: c�I fq INFORMATION WORKSHEET L c,J (�� SUBDIVISION: t-( I�'� \. t �-o �1 At ez `v,2S BLOCK: LOT: J ZONE: DISTRICT: LOT AREA: F/A: WIDTH: DEPTH: R/W: # OF BUILDINGS:_ # OF DWELLINGS: WATER DISTRICT: OWNER: AJ/4+L a,,�� S p),y �` � PHONE: -�; 3� - 53151 MAILING ADDRESS: CITY/STATE/ZIP: S / -D CONTACT: K41VI, PHONE : -5�, 30 J SETBACKS: - FRONT: LEFT: RIGHT: REAR: PERMIT USE: BUILDING INFORMATION CONTRACTOR LICENSE NUMBER: � JA (CLS, 410,C)o CONTRACTOR: PHONE: - MAILING ADDRESS: ARCHITECT/ENGINEER: MAILING ADDRESS: PHONE: - - NEW: REMODEL: ADDITION: CHANGE OF USE: DWELL UNITS: OCCUPANT LOAD: BUILDING HGT: STORIES: BUILDING DIMENSIONS: X (WIDTH X DEPTH) SQ. FT.: REQUIRED PARKING: # HANDICAP: SPRINKLERED: CRITICAL MATERIAL: Please provide the following information for L,»ergy Code ct. Space heating type (check one) Forced air electric Electric baseboard or wall mount Forced air gas Heat pump Flat ceilings R 38 Vaulted ceilings R Above grade walls R� Below grade walls R Floor R 30 Slab on grade R «r Propane Other: Doors U 0.1el Windows U 0.3 Glazing area Total floor area of heated space plod Furnace efficiency rating Please indicate on your plans: The location of the radon vent, and the location of the vent fan area. Square footage Main floor: /.& Second floor: � Basement - Finished. Unfinished: / Garage: Carport: Decks: Additional Areas: -WATTSUN 5.2- -- 1991 -WA -STATE ENERGY CODE COMPLIANCE REPORT 02/25/92 FILE: C:\WATTDATA\NATLEND5.WS HOUSE ID: NATLENDS Site: L 5, B 3, Pines West, 1st Ad Analyst: TAS Spokane County, WA Jurisdiction: Spokane County ( ) - Utility: WWP Homeowner: Builder: National Lender Services House Type: Single Family/Duplex Floor Area: 960 ft2 Weather Data: Spokane, WA Climate Zone: 2 -------------------------------------------------------------------------------- PROPOSED DESIGN COMPONENTS Component ------------------------------------------------------------------------------- Description Value X Area = The PROPOSED design *COMPLIES* with 1991 WA State Energy Code. U-0.028 960 REFERENCE PROPOSED **Vinyl frame dbl. glz.w/AR COMPONENT PERFORMANCE 160 155 Btu/hr-F ENERGY BUDGET 3.61 3.75 kWh/ft2-yr 16.3 REFERENCE DESIGN Metal 1-3/4" urethane flush U-0.140 21.0 2.9 Reference U-0.170 Component 3.6 Value X Area = UA ---------------------------------------------------------------- Floor 875 U-0.029 960 27.8 Glazing @15`o U-0.031 U-0.400 144.0 57.6 Doors U-0.200 42.0 8.4 AG Wall U-0.044 830 36.5 Ceiling, Attic U-0.031 960 29.8 Infiltration ACH-0.350 7680ft3( ---------------------------- 46.S) Reference UA 160 -------------------------------------------------------------------------------- PROPOSED DESIGN COMPONENTS Component ------------------------------------------------------------------------------- Description Value X Area = UA Floor **R-30 vented ,.foist 24"oc U-0.028 960 26.9 Glazing @10% **Vinyl frame dbl. glz.w/AR U-0.380 65.0 24.7 **Vinyl dbl.glz. patio w/AR U-0.480 34.0 16.3 Doors Metal 1-3/4" urethane flush U-0.140 21.0 2.9 **Metal 1-3/4" urethane raised panel U-0.170 21.0 3.6 AG Wall R19 ADV T1-11 U-O.OS8 875 50.8 Ceiling -------------------------------------------------------------------------------- R38 blown Attic STD baffled U-0.031 960 29.8 Items in parentheses not included in COMPONENT PERFORMANCE totals. ** Denotes non-standard values - check calculation of thermal value. Page 1 ------ WATTSUN 5.2 1991 WA STATE ENERGY CODE COMPLIANCE REPORT 02/25/92 FILE: C-\WATTDATA\NATLEND5.WS HOUSE ID: NATLEND5 Infiltration Standard Air Sealing ACH-0.350 7680ft3 ( 46.5) ---------------------------- Proposed UA 155 Struc Mass Light Frame, Sheetrock walls M- 3.000 960 2880 ------------------------------------------------------------------------------- HEATING/COOLING/VENTILATING SYSTEMS Heating System Type: System Efficiency: Modified Efficiency: Design ACH: Heating Load(at 66F dt) : System Size: Maximum Size @150%: Average Annual Heat Annual Cost Ventilation System: Cooling Load(at 12F dt) : Recommended Size @1250: Solar Access: PROPOSED Electric: Zoned 100 % 100 % 0.60 15486 Btu/h)- 4.5 tu/hr4.5 kW 6.8 kW 4680 kWh $ 257 Integrated Spot & Whole House 14646 Btu/hr 1.7 tons Partially Shaded -------------------------------------------------------------------------------- GLAZING ORIENTATION South: Southeast: East: Northeast: PROPOSED ft2 51.0 North: Northwest: West: Southwest: PROPOSED ft2 Economic and energy consumption estimates are designed for comparative purposes only. Actual cost for heating will vary depending on weather conditions, occupant lifestyle and other factors. Page 2 WATTSUN 5.2 COMPONENT CHECKLIST 02/25/92 FILE: C:\WATTDATA\NATLENDS.WS HOUSE ID: NATLENDS Name` Floor Area: 960 ft2 Address: L 5, B 3, Pines West, 1st Heating Type: Electric: Zoned Reference: 1991 WA State Energy Code ------------------------------------------------------------- FRAMING INSPECTION -------------------------------------------------------------- Approved plans: Are available onsite Air leakage: Soleplate is caulked or glued to subfloor. Rim ,.foists between stories are caulked/sealed. All holes in building envelope (i.e. exterior ceilings, walls, and floors) are caulked/sealed, including all electrical, plumbing, and HVAC penetrations. Outlets, switch boxes and recessed fixtures on exterior walls are caulked/sealed with approved sealant, or have foam face gaskets installed. Any recessed lights are IC rated, air tight, and sealed to the ceiling sheetrock. Wall framing: Net wall area: 875 ft2 Advanced framing with studs spaced 24" o.c., R-10 insulated headers and no isolated cavities which cannot be insulated. Structural panels: All structural sheathing is stamped "Exposure I" or "Exterior'' Windows: (Vinyl frame dbl. glz.w/AR 65.0 ft2) (Vinyl dbl.glz. patio w/AR 34.0 ft2) Windows are installed as shown on the approved plans. The rough opening around windows and doors is caulked/sealed. Exhaust fans, spot ventilation: Bathroom fans are 50 CFM, kitchen fans are 100 CFM. Fan ducting has minimal bends and terminates outside of the building. The whole house exhaust fan is between 50 and 75 CFM. The whole house fan is rated at 1.5 sones or less (unless remotely located). INSULATION INSPECTION Wall insulation: (R19 ADV T1-11 875.0 ft2) Insulation fills all exterior wall cavities. It is not compressed and is cut to fit around wires, pipes, and outlet boxes. Recessed Page 1 WATTSUN S.2 COMPONENT CHECKLIST 02/25/92 FILE: C:\WATTDATA\NATLEND5.WS HOUSE ID: NATLEND5 fixtures in exterior walls -have -at -least R-5 insulation behind them. Vapor retarder: 1.0 perm or less vapor retarder (e.g. poly, kraft paper, perm rated paint) is installed on the warm side of insulation in floors, ceilings and walls. Recessed lights: Any recessed light fixtures in the thermal envelope are certified under ASTM E-283 and labeled showing compliance, or are sealed around the exterior to be air tight. =INAL INSPECTION ------------------------------------------------------------ Crawl space moisture barrier: A six mil black polyethelene ground cover is installed on crawlspace floor. Floor Insulation: (R-30 vented Joist 24"oc 960.0 ft2) Insulation is supported in a permanent manner without compression. crawlspace ventilation: At least 3.2 Ft2 of net free ventilation is provided in the crawlspace. Pipe insulation: All water pipes in unheated spaces are insulated to R-3. Hot water: Electric water heater labeled as meeting ASHRAE Standard 90A-1980 or 1987 NAECA. Tank has R-10 non-compressible pad underneath if located over slab or in unconditioned space. Shower heads allow a maximum flow rate of 3.0 gallons per minute. Doors: (Metal 1-3/4" urethane flush 21.0 ft2) (Metal 1-3/4" urethane raised panel 21.0 ft2) Weatherstripping, threshhold, and doorsweep are properly adJusted and seal well. Ceiling (R38 blown Attic STD baffled 960.0 ft2) Insulation is installed to the manufacturer's recommended density and coverage. Attic access doors are insulated and weatherstripped. Heating system: Electric: Zoned The heating system does not exceed: 6.8 kW. Page 2 WATTSUN 5 2 - w COMPONENT'CHECKLIST 02/25/92 FILE= C=\WATTDATA\NATLENDS.WS HOUSE ID= NATLENDS Ventilation= The ventilation system has been checked for proper operation. If designed for intermittent operation, the system is controlled automatically by a time -of -day timer set to run for a minumum of eight hours per day. If designed for continuous operation, the system is directly wired to a dedicated circuit in the electrical panel. Make-up air= Ports or registers supplying outside air in the quantity of 10 CFM are located in each bedroom and the main living area. Radon monitor= Radon monitor supplied to residents. Exhaust duct insulation: All exhaust ducts in unheated spaces are insulated to R4. Page 3-------