Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
2011, 09-19 Permit App: 11002807 Pole Bldg
Spokane Valley Community Development Department Permit Center 11703 East Sprague Avenue, Suite B-3 Spokane Valley, WA 99206 Tel: (509) 720-2540 Fax: (509) 688-0037 permitcenterspokaneval Iey.orcl (Staff Use Only) PERMIT NUMBER: 11 --080 7 PERMIT FEE: RESIDENTIAL CONSTRUCTION PERMIT APPLICATION NEW CONSTRUCTION 111 ADDITION/REMODEL Ni DECK El OTHER SITE ADDRESS: / (g/3y RnZ ASSESSORS PARCEL NO.: (45o15a.,330p LEGAL DESCRIPTION: _Reck itivi pL ,ES74 o,((I-3/r5/ L- -,c,? ACCESSORY BUILDING BUILDING OWNER NAME: NAME: C,Le,r.r\ Irt5\Aa Arte. ADDRESS: ILls \3R g• CITY: 7 mak. (%ad„ei�, STATE: CONTACT NAME: rgrj'ct,j) Vc -4J PHONE: az,) (g©a FAX: WA - CELL: 0r (tel N, k 1►` fL( zip: ?Toa 7 n PHONE: )I . 5?0 1SA FAX: CELL: 5q6 • g? (-+.q CONTRACTOR NAME: 7-1 -6r4- 7 L.vm Cy. MAILING ADDRESS: coo E 1-110 LL.J I -/N CITY: PHONE: eo IL-PrN So- LE(o'7 - -i q (vo FAX: STATE: Vim] ZIP: rj` .D, I CELL: CONTRACTOR LICENSE No.: 'LS k(�-L.L4""3I(O-3-(a- EXPIRES: CITY BUSINESS LICENSE NO.: DESCRIBE THE SCOPE OF WORK IN DETAIL AND INDICATE USE & PROPOSED USE: Sfor tr3r Snocvrno6, s 71,14ck, 66Q-71- ITV /f Seg 4s. /;{ear ****YOU MUST COMPLETE THE FOLLOWING**** MARK N/A IF NOT APPLICABLE Height to Peak: it Dimensions: (� No. of Stories: / Total Habitable Space: Main Floor SQ FT: Upper Floor SQ FT: Unfinished Basement SQ FT: Finished Basement SQ FT: Garage SQ FT: QI _`1 CI�fG 1 Deck/Covered Patio SQ FT: Impervious Surface ,730%- Area: t '- CITY OF SPOKANE dopes on Property: VALLEY No. of Bedrooms: Construction Type: {Pp LS Heat Source: _ Sewer or Septic: yewcy TOTAL COST OF PROJECT: $ 013 DISCLAIMER V The permitted verifies, acknowledges and agrees by their signature that: 1) if this permits' for constrvction-arcrrra-ctwettlttg, the dwelling is/will be served by potable water. 2) Ownership of this City of Spokane Valley permit inure to the property owner. 3) The signatory is the property owner or has permission to represent the property owner in this transaction. 4) All construction is to be done in full compliance with the City of Spokane Valley Development code. Referenced codes are available for review at the City of Spokane Valley Permit Center. 5) The City of Spokane Valley permit is not a permit or approval for any violation of federal, state or local laws, codes or ordinances. 6) Plans or additional information may be required to be submitted and subsequently approved before this application can be processed. Signature % rtHMiI Lti\Itti Date: 7/r// Updated 1-11-11 Page 1 of 1 http://www.spokanevalley.org/filestorage/124/938/210/948/1496/Building_Permit= _Residential_11-11-11.doc Sj�1�� Residential Driveway PAVING WAIVER Community Development — Planning Division 11703 E Sprague Ave Suite B-3 ♦ Spokane Valley WA 99206 509.720.5026 ♦ Fax: 509.688.0037 ♦ planning@spokanevallev.orq Spokane Valley Municipal Code (SVMC) Section 19.40.020.B; "All residential driveway and off-street parking areas shall be paved with asphalt, Portland cement, grasscrete, paver blocks or other equivalent hard surface material". A paving waiver can only be granted if the structure you are proposing is not going to require a driveway for daily use. PART I — OWNER INFORMATION OWNER NAME: L...,Ledievn .--p, K ‘ I r\E- PARCEL #: 4i5a5,2 • aso$ ADDRESS: ' to 3 8 f KGS 2 CITY: Sp k \a / .""rV'j" p i ,_ STATE: LAM ZIP: 7 `Z'�03 I"" PHONE: 59 -g741 FAX: CELL: S,4 ✓"7- EMAIL: 6 K 11' nt CBCOG W I PART II -DETAILS OF PAVING WAIVER ;CO/y 1. Do you have an existing garage for parking daily use vehicles? KYES ❑ NO 2. Is the proposed detached structure used for storage only? 14YES ❑ NO 3. Do you plan on using the detached structure to park vehicles? [ZYES ❑ NO If yes, then what type of vehicles? 7/'uct< - Zoa - 5110) yi LES • AT) 4. Do you plan to conduct a business from proposed detached structure? ❑ YES MNO If so, what is the nature of your business? ,v,/�4 PART III —AUTHORIZATION CITY OF SPOKANE VALLEY SEP 0 9 2011 I,(PRINT NAME) UteAr1 \,i►rl� owner, hereby confirm that the information tirdittleirienitJs form is true and correct. I acknowledge that any change in the foregoing cont ons the City to impose paving requirements. I further agree to report any change in these conditions to the Spokane Valley Community Development Department, Planning Division, within 30 days. ICA l9 hi Owner Signature Date PART IV - DECISION STAFF HAS REVIEWED THE PROPOSED PAVING WAIVER ON BEHALF OF THE COMMUNITY DEVELOPMENT DIRECTOR AND FIND THE REQUEST IS GRANTED AT /03. E 1?C-rimbIZ SAID ADDRESS FOR PERMIT #: 1100 Z? O li-goof-g 9 %3/i/ Planning Division Staff Signature Date Created 6/27/11 Page 1 of 1 .40.1-h.: • '1 v �1. -b671,8 -M12SP- . 1N I i LLOZ 6 0 d3 , . tif'iI 7 17' • • 1 MM. • 'I 111 i i • A 9 0°11 1 BMW — IININFAIIMI Y. t Q _ 13.E • ` ) 1 r�-/cp.• -1 J"- 1 - 1 1i - -, ' 1/4l ' • 0 1 ' 3 r � � fid; • r ' r Id v �1. i WAMBEKE ENGINEERING 2913 East 61st Court Daniel Wambeke, P. E. Spokane, WA 99223 Telephone: 509-443-6186 • Fax: 509-448-6582 • dwambeke @msn.com September 3, 2011 Mr. Brian Bamett ZIEGLER LUMBER COMPANY 17002 East Sprague Avenue Spokane, WA 99037 SUBJECT: 24' X 24' X 14'4" POST FRAME BUILDING WITH 12' X 24' X 10'4' OFFSET LEAN-TO ONE SIDE FOR GLENN KLINE, 16138 E. RENZ, SPOKANE, VALLEY, WA 99037 Dear Brian: This building has been sold to Mr. Kline for erection in Spokane Valley utilizing the standard post frame building plans and lean-to addition plans I have provided for Ziegler Lumber Company. The required loading for this building site is 40 PSF roof live (snow) Toad, 85 MPH wind speed, Exposure B and Seismic Design Category C according to the 2009 International Building Code. Allowable soil bearing pressure is 2,000 PSF. Sidewall posts are spaced @ 12' centers and the roof will have 4:12 pitch manufactured trusses. I have reviewed the design of this building and checked it for the diaphragm design criteria used in the standard plan design. The front endwall has a 20' x 10' overhead door. The lean-to has a 10' x 8" overhead door. There is sufficient steel sheeting on these endwalls to transfer lateral loads on the sidewall and roof to the base of the building. However, it will be necessary to install #12 x 5/8" stitch screws 9" o. c. to all steel siding vertical side laps — this endwall only. The rear endwall has a 3'0" pass door. The rear endwall of the lean-to has a 4' x 3' window. There is sufficient steel siding on these endwalls to transfer lateral loads on the entire building sidewall and roof to the base of the building. The left sidewall has no openings. The right sidewall has no openings. Sidewall openings have no effect on the lateral load resistance for this building. You may use the standard 40 PSF live Toad post frame building plans and lean-to addition plans for all framing details and member sizes for this building. Common posts between the lean-to and the main building need to have 32" diameter x 3'0" deep concrete footings. Please feel free to contact me if you have any additional questions about the design of this building. Daniel Wambeke, P.E. Enclosure DW:dw CITY OF SPOKANE VALLEY SEP 0 9 1I]1' tFiWII IGEN i Eh tBY: f1. t. _ Designer of Small Structures, Post Frame Buildings, Foundations, Light Gauge Steel Framing and Grain Storage Systems A 3'-2" 6x8 20' 12'-0" 12'-0" 3/0 door 6x6 16 6x8 20' KLINE 12'-0" 11'-9" J 12'-0" - - 12'-0" — 6x6 24' 6x8 20' FUTURE LOFT POLES---1w- 6x616 ❑ 6x8 20' 4x3 window Ieanto 6x6 16' 6x6 16' C 10x8 OHD 24 -0" 6x8 20 G �14x6 20' 4x6 16 rE.6x6 16' ' 6x8 n 6x6 20' 20x10 OHD 6x0 20' 6x6 20' n r 20'-3" 24'-0" THIS ENDWALL ONLY! INSTALL #12 X 5/8" @ 9" O. C. STITCH SCREWS IN ALL STEEL PANEL VERTICAL LAPS 10" 10'-3" -.. THIS ENDWALL ONLY! INSTALL #12 X 5/8" @ 9" O. C. STITCH SCREWS IN ALL STEEL PANEL VERTICAL LAPS CITY OF SPOKANE VAI _I_EY SEP 092011 •ERMIT CEN I ER ivtta- NOTES FOR FLOOR PLAN S1 INTERI❑R FRAME WOOD POSTS, SEE POST SCHEDULE THIS SHEET GABLE END WALL POSTS - 6" X 6" TYPICAL DOOR POSTS - 4" X 6" TYPICAL F❑❑TING DIMENSI❑NS, B = 1'-8"; D = 3'-O" MAXIMUM POST SPACING 12'-0" S3 PURLINS @ 24" O.C., BEARING OR JOIST HANGERS (TYPICAL) 7Y OF SPOKANE VALLEY SEP 0 9 20111 1 1- L7 z W J 0 0 0 O f ti SPAN DOUBLE TRUSSES W A r-1 �D — LE TRUSSES SINGLE TRUSS PLAN VIEW YtHMI I- CLN [ Lt N.T.S. WAMBEKE ENGINEERING Daniel Wambeke, P. E. �Spol, ., dAst99223t Tel. 509-443-6186 Fox. 509-448-6582 e-nu8 dwonbekelnsn.con BUILDING PLAN VIEW STANDARD POST FRAME BUILDING PLANS ZIEGLER LUMBER COMPANY 620 EAST HOLLAND SPOKAE. WA 99218 12 DRAWN BY DATE WAMBEKE -24-08 APPROVED SCALE IBC-01.40WA NTS REV. SEE FOOTING/COLUMN SCHEDULE 1 SEE DETAIL 1 12 4 51 B NOTES FOR SECTI❑N A -A 0 TYPICAL PURLIN, SEE FLOOR PLAN FOR SIZE S2 TRUSS DESIGN BY OTHERS S3 2' X 6' @ 24' O. C., 10' BAYS DF -L #2 GIRTS FLAT @ 24' O.C. 2' X 6' @ 24' O. C., 12' BAYS DF -L #2 GIRTS FLAT @ 24' O.C. 0 CONCRETE F❑❑TING, SEE SCHEDULE S5 EXTEND POST TO TOP OF PURLIN ROOF FASTENED TO PURLINS WITH 1 1/2' LONG WOODFAST TEKS. WALLS FASTENED TO GIRTS WITH 1' LONG WOODFAST TEKS, SEE F❑❑TING DETAIL BUILDING SECTION A - A N.T.S. 0 WAMBEKE ENGINEERING Daniel Wambeke, P. E. 2S on't yiist992223 t Tell 509-443-6186 Fox. 509-448-6582 e -m t oWonbekeensn.con STANDARD BUILDING SECTION STANDARD POST FRAME BUILDING PLANS ZIEGLER LUMBER COMPANY 620 EAST HOLLAND SPOKAE. WA 99218 12 DRAWN BY DATE WAMBEKE -24-08 APPROVED SCALE NTS IBC-02.40WA REV. BUILDING SPECIFICATIONS: GENERAL — ALL BUILDING CONSTRUCTION SHALL CONFORM TO THE 2009 EDITION OF THE INTERNATIONAL BUILDING CODE (IBC 2009), AND ALL STATE & LOCAL BUILDING CODES. THESE SPECIFICATIONS AND PLANS ARE INTENDED FOR USE IN 40 PSF LIVE LOAD, 85 MPH WIND SPEED, EXPOSURE B AND SEISMIC DESIGN CATEGORY C. DESIGN LOADS — ROOF LL = 40 PSF ROOF DEAD LOAD = 5 PSF* CEILING LL = 0 PSF CEILING DL = 1 PSF * ROOF DL ALLOWS FOR A MAXIMUM OF 3" THICKNESS OF FIBERGLASS INSULATION. * MAXIMUM SOIL BEARING PRESSURE = 2,000 PSF MAXIMUM SOIL BEARING PRESSURE IS BASED ON SAND, SILTY SAND, CLAYEY SAND, SILTY GRAVEL AND CLAYEY GRAVEL SOILS OR BETTER BASED ON IBC TABLE 1806.2. LESSER SOIL CONDITIONS WILL REQUIRE REVIEW AND FOOTING SIZE ADJUSTMENT BY THE ENGINEER. CONCRETE — MINIMUM 28 DAY COMPRESSIVE STRENGTH F'c = 2,000 psi, 4 SACK MIX FOR FOOTINGS. CAST IN PLACE CONCRETE CONSTRUCTION SHALL CONFORM TO ACI 318-08. WOOD — STRUCTURAL LUMBER SHALL CONFORM TO DF—L #2 OR BETTER BY WWPA GRADING RULES. MAXIMUM MOISTURE CONTENT SHALL BE 19% BY WEIGHT. NAILING SHALL CONFORM TO TABLE 2304.9.1 FASTENING SCHEDULE & OTHER APPROPRIATE SECTIONS OF CHAPTER 23 OF THE IBC. ALL NAILS INTO PRESERVATIVELY TREATED WOOD SHALL BE HOT—DIPPED ZINC COATED GALVANIZED STEEL, SILICONE BRONZE, COPPER OR STAINLESS STEEL. CCA TREATED WOOD SHALL CONFORM TO THE REQUIREMENTS OF AWPA STANDARDS C-16, C-22, C-23, C-24 & C-28. POSTS FOR BUILDINGS SHALL BE AS NOTED ON THE PLANS. ALL POST MATERIALS SHALL BE HEM—FIR #2 OR BETTER, FULL DIMENSION AND GRADED BY WWPA GRADING RULES. HARDWARE SHALL BE SIMPSON OR APPROVED EQUAL. ALL BOLTS SHALL CONFORM TO ASTM A307. METAL PANELS MAY BE DELTA RIB STYLE, GALVANIZED OR PAINTED, 29 GAUGE THICKNESS, ASTM A653 STRUCTURAL QUALITY (SO), Fy = 80.0 ksi. ROOF PANELS SHALL BE FASTENED TO PURLINS WITH PLATED, GASKETED 1 1/2" LONG METAL TO WOOD FASTENERS. WALL PANELS SHALL BE FASTENED TO GIRTS WITH PLATED, GASKETED 1" OR LONGER METAL TO WOOD FASTENERS. PANELS SHALL BE INSTALLED AND FASTENED ACCORDING TO THE MANUFACTURER'S RECOMMENDATIONS. ALTERNATE ROOFING & SIDING APPLICATIONS — BUILDING ROOF MAY BE SHEETED WITH 15/32" 0.S.B. BOARD, 1/2" C—DX PLYWOOD OR OTHER APA RATED SHEETING, NAILED 0 6" 0. C. W/ 8d OR 10d NAILS. FINISH COVERING FOR SHEETED ROOF MAY BE COMPOSITION ROOFING OVER 30# FELT, OR 29 GAUGE METAL ROOFING OVER 15# FELT. BUILDING MAY BE SIDED WITH 7/16" O.S.B. BOARD, 1/2" C—DX PLYWOOD. 15/32" T-111 PLYWOOD SIDING OR HARDI—PLANK. LAP SIDING MAY BE INSTALLED OVER BUILDING WRAP AND WALL SHEETING. SHEETING SHALL BE FASTENED TO GIRTS WITH 8d, NAILS O 6" 0. C.. OR 1 1/2" LONG X 16 GA. STEEL STAPLES 0 6" 0. C. 0 PANEL EDGES & INTERMEDIATE FRAMING. SOIL COMPACTION — ALL BACKFILLED SOIL BENEATH FOOTINGS SHALL BE COMPACTED WITH A VIBRATORY COMPACTOR TO 95X OF THE PROCTOR DENSITY AS DETERMINED BY ASTM A1557, METHOD D. TRUSSES SHALL BE DESIGNED BY AND BEAR THE SEAL OF AN ENGINEER REGISTERED TO PRACTICE IN THE STATE OF WASHINGTON. TRUSS LOADING: TOP CHORD LIVE LOAD = 40 PSF TOP CHORD DEAD LOAD = 5 PSF BOTTOM CHORD DEAD LOAD = 1 PSF WAMBEKE ENGINEERING Daniel Wambeke, P. E. aamat ,Ast t Tel. 509-443-6186 Fax. 509-448-6582 e-nnl depnbekeP, n.con 2009 IBC SPECIFICATIONS FOR TYPICAL POST FRAME BUILDINGS ZIEGLER LUMBER COMPANY 620 EAST HOLLAND SPOKA E. WA 99218 DRAWN BY DATE WAMBEKE —08-10 APPROVED SCALE NTS IBC03-40WA REV. NOTES FOR F❑❑TING DETAIL TREATED POSTS AS SIZED PER SCHEDULE VIBRATE OR ROD CONCRETE TO OBTAIN FULL BEARING S3 UNDISTURBED S❑IL FOOTING DETAIL N.T.S. WAMBEKE ENGINEERING Daniel Warbeke, P. E. 2 ENGINEERING 999�t Pnknne, 61A TO 509-443-6186 Fax. 509-448-6582 e-nnl tlrnnbeke!nsn.con STANDARD FOOTING DETAILS STANDARD POST FRAME BUILDING PLANS ZIEGLER LUMBER COMPANY 620 EAST HOLLAND SPOKAE. WA 99218 DRAWN BY DATE WAMBEKE —24-08 APPROVED SCALE NTS IBC04 REV. POST/FOOTING SCHEDULE 12' - 24' SPANS, 40 PSF LIVE LOAD POST COLUMN FOOTING KNEE BRACE CONCRETE SPACING "H" W X D "B" DIA. "T" REQUIRED VOLUME, YD3 10'-0" 8'-0" 6" X 6" 24" 3'-0" NO 0.35 10'-0" 10'-0" 6" X 6" 24" 3'-0" NO 0.35 10'-0" 12'-0" 6" X 6" 24" 3'-0" NO 0.35 10'-0" 14'-0" 6" X 6" W/2" X 6" 24" 3'-0" NO 0.35 10'-0" 16'-0" 6" X 8" 24" 3'-0" NO 0.35 10'-0" 18'-0" 6" X 8" W/2" X 6" 24" 3'-0" NO 0.35 10'-0" 20'-0" 6" X 10" 24" 3'-0" NO 0.35 10'-0" 22'-0" 6" X 10" 24" 3'-2" NO 0.37 10'-0" 24'-0" 6" X 10" W/2" X 6" 24" 3'-8" NO 0.43 12-0" 8'-0" 6" X 6" 26" 4'-0" NO 0.41 12-0" 10'-0" 6" X 6" 26" 3'-0" NO 0.41 12-0" 12'-0" 6" X 6" W/2" X 6" 26" 3'-0" NO 0.41 12-0" 14'-0" 6" X 6" W/2" X 6" 26" 3'-0" NO 0.41 12-0" 16'-0" 6" X 8" W/2" X 6" 26" 3'-0" NO 0.41 12-0" 18'-0" 6" X 8" W/2" X 6" 27" 3'-0" NO 0.45 12'-0" 20'-0" 6" X 10" 27" 3'-3" NO 0.48 12'-0" 22'-0" 6" X 10" W/2" X 6" 27" 3'-6" NO 0.52 12'-0" 24'-0" 6" X 12" 27" 3'-10" YES 0.57 NOTE: 1. THE NEXT LARGER SIZE POST MAY BE SUBSTITUTED FOR POSTS WITH 2" X 6" LAMINATIONS. 2. ENDWALL POSTS SHALL BE 6" X 6" ROUGH CUT HEM -FIR #2 TREATED POSTS UP TO 16'-0" WALL HEIGHT. ABOVE 16' WALL HEIGHT, ENDWALL POSTS SHALL BE 6" X 8" ROUGH CUT HEM -FIR #2 POSTS. 3. FOOTINGS FOR ENDWALL POSTS SHALL BE A MINIMUM OF 20"0 X 3'-O" DEEP FOR WALL HEIGHTS TO 16'-0". ABOVE 16' WALL HEIGHT, FOOTINGS SHALL BE 24"0 X 3'-4" DEEP. 4. ABOVE FOOTING DESIGNS ARE FOR POST FRAME BUILDINGS WITH CONCRETE FLOORS (CONTRAINED POSTS). IF BUILDINGS WILL NOT CONCRETE FLOORS, INCREASE FOOTING DIAMETER X 2" & FOOTING DEPTH X 4". WAMBEKE ENGINEERING 29Daniel War�beke, P. E. Spokane, 61stCourt Teb 509-443-6186 Fax. 509-448-6582 e-naN dranbekelnsn,con POST & FOOTING SIZES 12' TO 24' SPANS — 40 PSF L.L. n STANDARD POST FRAME BUILDING PLANS ZIEGLER LUMBER COMPANY 620 EAST HOLLAND SPOKAE. WA 99218 12 DRAWN BY DATE WAMBEKE —24-08 APPROVED SCALE NTS IBC05-24.40WA REV. DETAIL 1 - TRUSS COLUMN CONNECTION, PURLIN SUPPORT N.T.S. NOTES FOR CONNECTION DETAIL SI MANUFACTURED TRUSS TOP CHORDS TRUSS DESIGN BY TRUSS MANUFACTURER © PURLIN SUPPORT STRUT 2' X 6' X FULL DEPTH OF TOP CHORD PLUS PURLIN. NAIL PURLINS W/(3) 16d NAILS ©NAIL STRUT TO TOP CHORD W/(3) 16d NAILS EACH SIDE. ®MANUFACTURED TRUSS - NAIL TO EACH SIDE OF POST WITH 4 - 16d NAILS ON TOP NAILING BLOCK ©WOOD POST, SEE POST/FOOTING SCHEDULE. © 4 - l0d NAILS ge7 SOLID BLOCKING AT CONNECTION POINTS. TYP. PURLIN, SEE FLOOR PLAN FOR SIZE 2' X 6. OR 2' X 8' EAVE GIRT KNEE BRACE, IF REQ'D. SEE POST SCHEDULE AND DETAIL 2 Il 2' X 6' X 24' OR 2' X 8' X 24' BLOCK m 41) 1®1 1 — 1 - 2 - 3 - 4 - 5 - ®1 4 - 3/4' 0 MACHINE 3/4' 0 MACHINE 3/4' 0 MACHINE 3/4' 0 M. BOLT 3/4' 0 M. BOLT 3/4. 0 M. BOLT 3/4' 0 M. BOLT 16d NAILS BOLT THRU TRUSS T. CHORD BOLT THRU KNEE BRACE BOLT THRU BOLTING BLOCK @ BOLTING BLOCK - 24' & 30' @ BOLTING BLOCK - 36' & 40' @ BOLTING BLOCK - 50' @ BOLTING BLOCK - 60' PURLIN CONNECTION METHODS1 A). PURLINS MAY BE HUNG OFF THE TRUSS TOP CHORD FACES W/ STD. SIMPSON JOIST HANGERS OR EQUAL. B). PURLINS MAY BE BUTTED AND NAILED W/(2) 16d NAILS INTO EACH PURLIN. C). PURLINS MAY BE LAPPED ANDNAILED W/(3) 16dNAILS. ON CONNECTION METHODS 'B' AND 'C', TOENAIL BACK SIDE OF PURLIN W/(1) 16d NAIL INTO EACH TOP CHORD MEMBER WAMBEKE ENGINEERING Daniel Warobeke, P. E. eitgkFlt V1:t999av Tel. 509-443-6186 Fnw 509-448-6582 e-in1 drnnbekelroncon TRUSS — COLUMN CONNECTION PURLIN CONNECTION METHODS STANDARD POST FRAME BUILDING PLANS ZIEGLER LUMBER COMPANY 620 EAST HOLLAND SPOKAE. WA 99218 12 DRAWN HY DATE WAMBEKE —24-08 APPROVED SCALE NTS IBC06 REV. 12 4 20' 0' MAXIMUM SINGLE OVERHEAD DOOR ❑PTI❑N FRONT ELEVATION NOTES FOR FRONT ELEVATI❑N N.T.S. SD HALF TRUSS DESIGN BY OTHERS SUPPORT PURLINS @ END TRUSS W/2' X 6' S6 TREATED 2' X 6' BOTTOM GIRT S2 2' X 10' HEADER S3 2' X 6' GIRTS @ 24' ❑.C., 10' BAYS, DF -L #2 2' X 6' GIRTS @ 24' O.C., 12' BAYS, DF -L #2 0 2' X 8' FACIA BOARDS SS TREATED WOOD POSTS, SIZED PER SCHEDULE 0 TREATED 2' X 6' BOTTOM GIRT OR TREATED 2' X 10' BOTTOM GIRT WAMBEKE ENGINEERING t Daniel Warlbeke, P. E. Spokane , VA 992C23 Tel 509-443-6186 Fax. 509-448-6582 e-naR deanbekelnsncon FRONT ELEVATION SINGLE OVERHEAD DOOR OPTION TYPICAL POST FRAME BUILDINGS ZIEGLER LUMBER COMPANY 620 EAST HOLLAND SPOKANE. WA 99218 DRAWN BY DATE WAMBEKE —24-08 APPROVED SCALE NTS IBC09 REV. S6 3068 MAND❑❑R ❑PTI❑N Lid OPTIONAL FRONT ELEVATION NOTES FOR ❑PTI❑NAL FRONT ELEVATIONS 0 HALF TRUSS DESIGN BY OTHERS 0 2' X 10' HEADER UP TO 12' 0' DOORS 2' X 12' HEADER UP TO 20' 0' DOORS 0 2' X 6' HEADER 0 4' X 6' DOOR POST - 8' THRU 14' WALL HEIGHT W/ 2' X 6' FACER. 6' X 6' DOOR POST - 16' & 18' WALL HEIGHT W/ 2' X 8' FACER. 0 2' X 4' WINDOW JAMB J N.T.S. OPENING WAMBEKE ENGINEERING 2913 East 61st t Daniel Wambeke, P. E. Spokane, WA 9 Tell 509-443-6186 fax 509-448-6582 e-naH tleanbeketnsncon FRONT ELEVATION PASS DOOR OPTION TYPICAL POST FRAME BUILDINGS ZIEGLER LUMBER COMPANY 620 EAST HOLLAND SPOKAE. WA 99218 DRAWN BY DATE WAMBEKE —24-08 APPROVED SCALE NTS IBC12 REV. 98 1 TYPICAL TRUSS BOTTOM CHORD BRACING NOTES FOR TRUSS BOTTOM CHORD BRACING Si GABLE END TRUSS 0 DOUBLE INTERI❑R TRUSSES 0 GABLE END POST 0 2' X 4' BOTTOM CHORD BRACING @ 10' 0' 0.0. 0 2' X 3' BLOCK WITH 4 - 10d NAILS TO BOTTOM CHORD BRACE SHEATHING REQUIRMENTS THE FOLLOWING MINIMUM ROOF DIAPHRAGM REQUIREMENTS ARE NEEDED! * ROOF STEELI 29 GAUGE GRAND -RIB III, 36' WIDTH OR EQUIVALENT * FIELD SCREWS #10 x 1 1/2' AT 9' O.C. (NEXT TO HIGH RIB) ✓ EAVE AND RIDGE PURLIN SCREWS' #14 xl 1/2' AT BOTH SIDES OF EACH MAJOR RIB THE FOLLOWING MINIMUM ENDWALL DIAPHRAGM REQUIRMENTS ARE NEEDED! * ENDWALL STEEL' 29 GAUGE GRAND -RIB III, 36' WIDTH OR EQUIVALENT * FIELD SCREWS *10 x 1 1/2' @ 9' O.C. (NEXT TO HIGH RIB) 10 BASE GIRT, END TRUSS, AND DOOR HEADER SCREWS! 4#14 x 1 1/2' @ BOTH SIDES OF EACH MAJOR RIB. DIAPHRAGM SCREWS DIAPHRAGM SCREWS @ ENDWALL BASE GIRT ACROSS ENDWALL DOOR HEADERS & GABLE END TRUSS TOP CHORD, EAVE & RIDGE PURLINS ON ROOF DIAPHRAGM SCREWS) TYPICAL SCREW PATTERN, EXCEPT AS NOTED ABOVE N.T.S. STEEL SHEETING SCREW PATTERNS WAMBEKE ENGINEERING N.T.S Daniel WaMbeke, P. E.29pokan., Wt A t99223t TO 509-443-6186 Fox. 509-448-6582 a -null deanbekelnsncon TRUSS BOTTOM CHORD BRACING & WALL SHEETING TYPICAL POST FRAME BUILDINGS ZIEGLER LUMBER COMPANY 620 EAST HOLLAND SPOKAE. WA 99218 DRAWN BY DATE WAMBEKE —24-08 APPROVED SCALE NTS IBC14 REV, 1' 1" - 16d NAILS 6", 8" OR 10' POST NAILING PATTERN FOR POST LAMINATIONS NOTE: 2" X 6" LAMINATE MUST BE A TREATED MEMBER AND MUST EXTEND TO THE BOTTOM OF THE FOOTING. LAMINATE MAY BE SPLICED ABOVE MID HEIGHT OF COLUMN 8 - 16d NAILS TREATED PDST 2' X 4' BACKER REQ'D @ 48' O.C. FOR BAYS LARGER THAN 11' - 16d GALV, NAILS EACH GIRT ' X 6' FLAT GIRT @ 24' O. C. FOR 8', 10' & 11' BAYS TYPICAL GIRT CONNECTION GABLE END TRUSS 2' X 6' X 18' BOLTING BLOCK - 16d NAILS CORNER PDST 2' X 6' X 18' BOLTING BLOCK DETAIL 3 - 16d NAILS TYP, GABLE END TRUSS CONNECTION USE BOLTING BLOCKS BELOW ALL CORNER COLUMN GIRTS WAMBEKE ENGINEERING t Daniel War�beke, P. E. spokrtne. WA za Ted 509-443-6186 Fax. 509-448-6582 mall deenbekeMsn.CON GIRT CONNECTIONS, GABLE END TRUSS LAINATIO DETAI STTANDARD STONNECTIOPOST OFRA E MBUILD NG PLANS ZIEGLER LUMBER COMPANY 620 EAST HOLLAND SPOKAE. WA 99218 la DRAWN BY DATE WAMBEKE -30-O3 APPROVED SCALE NTS IBC15 REV. -0" WALL HEIGHT 2"X6"/2"X8" EAVE GIRT O.S.B. BOARD, T-111 SIDING OR HARDI—PLANK SIDING 2" X 10" TREATED SKIRT BOARD 2" X 6" TOP PLATE TRUSSES 2" X 6" BLOCKING ® MIDHEIGHT FOR WALLS TALLER THAN 10'-0" 2" X 6" VERTICAL STUD 2" X 4" P. T. PLATE CONCRETE FLOOR CONCRETE FLOOR 111 2" X 6"/2" X 8" TRUSSES EAVE GIRT J 0 0 0 0.S.B. BOARD, T-111 SIDING OR HARDI—PLANK SIDING 2" X 10" TREATED SKIRT BOARD 2" X 4" TOP PLATE 2" X 4" VERTICAL STUD 2" X 3" P. T. PLATE STUD WALL FOR POST FRAME BUILDINGS STUD WALL FOR POST FRAME BUILDINGS WAMBEKE ENGINEERING Daniel Wambeke. P. E. 2915 Eee1 a"` 223 2913 e WA 98223 Tet 509-445-6186 Foe: 509-440-6582 a-ma6 drombekeOmea.com STUD FRAME WALLS FOR POST FRAME BUILDING CONSTRUCTION ZIEGLER LUMBER COMPANY 620 EAST HOLLAND SPOKANE, WASHINGTON 99218 DRAWN B1 DATE DRAWING NO.: SND WALL WANBEKE 1-10-10 SCALE3/e . 1'-o (SHEET: 1 OF 1 REV. N� [ O O .a O;,, zc si. z. 0, a cx„21 - 8 4 m g �ffi� Z = CO 6— 1(~jlO< WCh2 of .a.--+zz _ Ela=>i0$ u o 1'08 8°6 wZ u. ZZ,., 7 Yffi��°'m5y18 Np O, O 1O< WiincO��xJ. Y � G' 4.2- ad -hili m i 1 NH JWy .<.9.,C. Z Z4 a 00C p J N M N m N a 111111111111111111! 8 ;1; Illili dd * 11 t i 04A 4pFF0A hep a7pA�eRpo i 7EEEEEEEEEEE���E�t€€€€EE�E 3 B gb ISI EL py y. a�! l] y 0 1 11 i5:rog.f "g Vie% ® *®® NO 01)90 4: i fl x 1,0 limiaq: 1 43E01 111111eiliIi 1114.1 ! 11! IliiiiililITI:!1;101i 1 :10A!.11:14111112 I: ;1dI � lisch aaid i� l i & y- 1 11 1;11Alliiiiiliiiii:P11111lii 111101$1q1111!!!!ii1104111i IlvillsilliTipil-i!#Iii; ti ,11 1 Heil! 4iligliligs E1 .. V z 5 m ce Q ai 1 0 G. 0 1— z 0 0 0 Q 0 1— I z Q W -J W 0. 0 L. 0 0 CC 5001343AV3 .0.0 DJ .0A