2008, 08-26 Permit App: 08003274 Deck Project Number: 08003274 Inv: 1 Application Date: 8/26/2008 Page 1 of 2
THIS IS NOT A PERMIT
Penalties will be assessed for commencing work without a permit
Project Information:
Permit Use: NEW 12 X 16 DECK Contact: MANDERE CONSTRUCTION
Address: 13964 N OHIO
C-S-Z: RATHDRUM,ID 83858
Setbacks:Front Left: Right: Rear: Phone: (208)687-3308
Group Name:
Site Information: Project Name:
Plat Key: 000000 Name: Range District: East
Parcel Number: 46353.1701 Block: Lot:
SiteAddress: 5020 N REES RD Owner:Name: ROGERS,L D&S L
Address: 5020 N REES RD
Location::CSV SPOKANE VALLEY,WA 99216-304
Zoning: R-3 SF Res District
Water District: 001 TRENTWOOD Hold:
Area: 10,935 Sq Ft Width: 80 Depth: 136 Right Of Way(ft): 0
Nbr of Bldgs: 1 Nbr of Dwellings: 1
Review Information: .. . maw. .: .. . . ,._. . .
Review
Building Plan Review Released By:
Originally Released: 8/26/2008 By: tmelbourn
Landuse/Zoning/HE Conditions Released By:
Originally Released: 8/25/2008 By: mpalaniuk
Permits:
Operator: jmm Printed By: JD Print Date: 8/26/2008
Project Number: 08003274 Inv: 1 Application Date: 8/26/2008 Page 2 of 2
THIS IS NOT A PERMIT
Penalties will be assessed for commencing work without a permit
Building Permit
Contractor: OWNER Firm: OWNER
Phone: (000)000-0000
This Application: Total Project:
Description Grp Type Notes Sq Ft Valuation Sq Ft Valuation
DECK OPEN R-3 VB 192 $2,880.00 192 $2,880.00
Totals: 192 $2,880.00 192 $2,880.00
Item Description Units Unit Desc Fee Amount
RESIDENTIAL PERMIT FEE 1 SELECT $83.25
WSBC SURCHARGE 1 SELECT $4.50
SF PLNS RVW<7999 SQ FT 1 SELECT $33.30
Permit Total Fees: $121.05
Payment Summary
Permit Type Fee Amount Invoice Amount Amount Paid Amount Owing
Building Permit $121.05 $121.05 $0.00 $121.05
$121.05 $121.05 $0.00 $121.05
Disclaimer:
Submittal of this application certifies the owner(or person(s)authorized by the owner)has both examined and finds the information
contained within to be true and correct,and agrees that all provisions of laws and/or regulations governing this type of work will be
complied with. Subsequent issuance of a permit shall not be construed to be a permit for,or an approval of,any violation of any of
the provisions of the code or of any other state or local laws or ordinances.
Signature:
Operator: jmm Printed By: JD Print Date: 8/26/2008
Permit Center
-
Sn lae - 11703 E Sprague Ave, Su B 3 ��.°
Spokane Valley,WA � VALLEY
PERMIT NUMBER:, �`r
PERMIT FEE:
3�
jValleY. (509)688-0036 FAX: (509)688-0037
www.spokanevalley.org 1, 1 2[10b
Community Development
Residential Construction , 3LCnnstruction Accessory Bldg
Permit Application n Addition/Remodel Int: Deck
n Other:
SITE ADDRESS: 5-0 20 Al. Rees RD, S Kiar� °61\12L '
LOQ 9ctal(P
ASSESSORS PARCEL NO: y(p'S3, )1 rll LEGAL DESCRIPTION: 1.1.enrkii e\<Spn Shin LI aa.
Building Owner: Contractor:
Name: LA pie y p. R 0 G GQs Name: fvE iQ0 FF 6ttA,t/D>E,e£ !/S9'
Address: 50.20 /f/. /P GS AD. Address: /3 9 ,1 4/. 4 Hi 0
City: SOOKgv� (/act fiy State:w4 Zip:992,, City: /C/4774 a/QUM State: leD Zip: o
Phone:
.D f, 9_-G .59C.5 Fax: Phone:_ . G Q7 •3308 Fax: -2d 8 '&(7• 94z4/
Contractor Lic No: Exp Date:
Contact Person City Business Lic.No:
Name: 1114 . Rer tit S
Phone: co q . figgiffsrsi Qat. -3953 Maki()EC. )'IDSDP
Describe the scope of work in detail: Cost of Project: $ 3 5OO.00
7-44 R. J'vud.1/ 'L2 2 *' 4-7t/A Q£P.Ac G W ,r7/ A ,Wed at/-
Proposed Use: PC oAmL - at ,Av(. , 5crftimi6 , i44-z,fide,
**************The following MUST be complete: (write N/A if not applicable)**********************
HEIGHT TO PEAK: DIMENSIONS: #OF STORIES: TOTAL HABITABLE SPACE:
/V/A N� /or X /4 A//4 4/ II
MAIN FLOOR TO SQ. 2 FLOOR SQ. FTG: UNFIN BASEMENT SQ. FTG: IMPERVI US SURFACE
FTG: /A //� P /WA AREA: ou/4
FINISHED BAS MENT GARAGE SQ. FTG: DEC . • • ' = 0. FTG: 30% SLOPES ON n
SQ. FTG: /l/ A /(,/d) /9.2 a' - PROPERTY: 4//T
#OF BEDR OMS: CONSTRUCTION TYPE: •- - •UR ' SEWER OR SEPTIC?
n//A /e iPasr ,h4 /9 -Sftelte
The permitee verifies, acknowledges and agrees by their signature that: 1) If this permit is for construction of or on a dwelling,the
dwelling is/will be served by potable water. 2) Ownership of this City of Spokane Valley Permit inure to the property owner. 3) The
signatory is the property owner or has permission to represent the property owner in this transaction. 4) All construction is to be done
in full compliance with the City of Spokane Valley Development Code. Referenced codes are available for review at the City of
Spokane Valley Permit Center. 5) This City of Spokane Valley Permit is not a permit or approval for any violation of federal, state or
local laws,codes or ordinances.6) Plans or additional information may be required to be submitted, and subsequently approved before
this application can be rocessed.
SIGNATURE: DATE: $-11-0g
Method of Payment:
❑ Cash ❑ Check ❑ Mastercard ❑ VISA
Bankcard#: Expires: VIN#:
Authorized Signature:
REVISED 2/15/07
RESIDENTIAL CHECK LIST DIRECTIONS:
Place a check mark in box next to each document required for complete submittal.
❑ SITE PLAN
o Property lines and dimensions o Setbacks to property lines
❑ Direction arrow pointing North and orientation to streets o Distance between buildings
o Proposed/existing buildings (footprint and dimensions) o Right of way/easement location &sizes
o Utilities, septic tank/drain field locations and distances o Driveway approach size and location
BUILDING PLANS (3 SETS) (minimum 1/8 inch scale or completely dimensioned)
❑ Elevations (Front/Rear/Sides)with roof peak and wall height including basement:
❑ Foundation Plan (crawlspace, basement or slab on grade):
o Footing sizes and locations o Supporting wood cripple walls or beams
o Perimeter concrete foundation wall sizes o Thickened concrete pads supporting
o Crawlspace ventilation beams or girder trusses
❑ Floor Plan of each level (finished or unfinished)with dimensions:
o Floor Joist direction, size and spacing o Window and door location and sizes
o Header, beam or concrete lintel sizes o Window well locations if applicable
o Brace wall panel locations o Room usage labels
o Water heater and furnace locations o Smoke detector locations
o Exhaust fan locations o Attic and crawl space access locations
o Deck or concrete patio sizes and locations o Fire Wall construction
❑ Roof Plan:
o Engineered truss direction and spacing o Ridge, eave and valley lines
o Rafter and over frame direction, size and spacing o Beam and girder size and location
❑ Wall Section Detail including:
Roof
o Slope/roofing material/underlayment/ice dam protection o Truss or rafter size, spacing &connection
❑ Sheathing size and type ❑ Attic insulation/air space baffle/ventilation
Ceiling
o Joist size and spacing ❑ Size of ceiling gypsum wall board
Wall
o Height/top plate/stud size and spacing/sole plate o Siding/exterior house wrap/anchor bolts
o Exterior sheathing size and type ❑ Insulation, vapor barrier, gypsum wall board
Floor
o Joist size and spacing ❑ Sheathing or concrete floor size/insulation
Foundation Wall
❑ Concrete or Masonry unit width ❑ Footing bottom to finished ground level depth
o Earth to wood separation distance o Horizontal &vertical reinforcement if any
Footing
o Size ❑ Reinforcement if any
Radon
o Passive system with 6mil vapor barrier ❑ Active system with 6 mil vapor barrier
Miscellaneous Construction Details
g Deck:
%Floor plan/side view/dimensions Footings/post/and beam size and locations
ig.Floor Joist/decking direction, size and spacing
0 Stairway tread rise &run and nosing 10 Handrail/Guard height &spacing
1'
Pro• ec l- New project El
TY 1 , New
pre-app meeting
El
o P ne Transmittal Plan revisions
City of Spokane Valley Transmittal Date:
...•O'Valley
Community Development Thursday,August 21,2008
Department
11703 E.Sprague Ave,Suite B3
Spokane Valley,WA 99206
Phone:509.688.0036
Site Address: 5020 N REES RD Project Number: 08003274
Parcel Number: 46353.1701
Zoning: R-3 Water District: TRENTWOOD
Fire District: FD 01
Applicant: MANDERE CONSTRUCTION Owner: ROGERS, L D & S L
13964 N OHIO 5020 N REES RD
RATHDRUM, ID 83858 SPOKANE VALLEY, WA 99216-304
(208) 687-3308
e-mail: e-mail:
Contact: MANDERE CONSTRUCTION Occupant:
13964 N OHIO e-mail:
RATHDRUM, ID 83858
(208) 687-3308
e-mail D L F I I r� M i l--�
FE
Contractor: MANDERE CONSTRUCTION INC Arch/Engineer:
13694 N OHIO ST 1m- AU:.; i 3 %.(ri
RATHDRUM, ID 83858 D) if�
(509) 891-6096 D) -11L-
L - B n I 5
e-mail: it
Project NEW 12 X 16 DECK
Description:
Building Landuse Engineer Utilities Health Fire Dist Assessor
APPLICATION
CONSTRUCTION PLANS
i
SITE PLAN ` )
TDS
Please send all plan review and project comments via e-mail to the
highlighted individuals.
•
For City Use Only
CITY OF .:.
PLUS Project Number -)2.----,1
Spokane Project Address O Q g�
5 Z ,y
Valle °
y 11703 E Sprague Ave Suite B-3 ♦ Spokane Valley WA 99206
509.688.0036 ♦ Fax: 509.688.0037 ♦ permitcenter@spokanevalley.org
As part of our on-going commitment to customer service during the review process of your project
application, we are providing you with a TARGET DATE for the initial technical application review. If for
any reason we cannot meet this date, we will contact you with a revised target date.
Your application review TARGET DATE is -6 0:1 \ O`�°
The TARGET DATE is the date we estimate your project application will have had its initial technical
review. It is not the date for approval or permit issuance.
Tips for a Smoother Project Application Review
➢ Submit complete, accurate plans and documents.
Extra time may be required for re-submittals as project application reviewers work on multiple applications and it
may be several days before they can look at your new or revised information.
> Designate a specific contact person to communicate with the City.
While the person designated as the applicant's contact person with the City can be changed, one individual with the
expertise for dealing with reviewer comments would be the best choice for the entire review process.
> Call staff regarding the status of your project only after the target date shown at the top of the page.
Although you should be contacted on or by the target date,please feel free to contact us if you haven't heard from us
by your target date. Staff may contact you before the target date if the initial review is complete. By following this
procedure,you will save time and allow the reviewers to complete the work more expeditiously.
Steps in the Permit Process
1. Counter Complete. Your application has been accepted as counter complete. This means all of the required
documents, as indicated on your Pre-Application Checklist have been submitted or have been approved for deferred
submittal. This does not prevent technical staff from requesting additional information as a result of their technical review.
2. Quality Check. The next step in the process is a quality check to make sure that the application is reviewable and free
from substantive flaws that would prevent technical staff from completing the technical review once it is started. When
this step is complete, your application will be routed to the appropriate staff and remain in their review queue until it
comes up for review.
3. Technical Compliance. Once an application is administratively complete, it is routed to technical staff for compliance
review. Depending on the type of project, technical staff may include multiple reviewers. You should be contacted by
phone,fax, email,or mail by your TARGET DATE once the initial technical compliance review is complete.
4. Permit Issuance. When the technical compliance review of the application is complete, including any subsequent re-
submittals, each reviewer will approve their section of the application and route it to the Permit Center. When all sections
of the application are received, a Permit Specialist will process the application and contact the person specified on your
application for permit pick-up. Information regarding fees and pre-construction meetings (if required) will be provided by
the Permit Specialist at that time.
WHITE—APPLICANT PINK—BUILDING FILE REV 9/07
•
46' north edge of deck to north side —
Wabash Road of property
Road Sign •zir
a' Fire Hydrant
Sewer Location
Land Size 10,935 sq. ft. PLAN NTNG DEPT. AP• •OVER
•
House—28' 6" depth BY „
DA'E: '2//
461
czt - V) CL)
0
(24 Tree 3 v, Shed
14)
cD
CD
C)
n
Deck Plan
16 feet wide 57' deck edce to hack of lot
12 feet wide 71.
5 feet 6 inches high Deck
12 2X10 joists placed 16" apart •
•
AL
cu bu bA
59' front of lot to deck edge
Driveway c.7 o
Garage 25'
depth 0 28' south side of deck to
south side of property
N T
W F
SITE PLAN
LARRY ROGERS—NEW DECK
AUGUST/SEPTEMBER,2008
a .
Wabash Road
Road Sian
a Fire Hydrant
Sewer Location
T,and Size 10.915 soft.
House
3 --� Shed
a) Tree
b
0
N CD
c�
T1
CD
CD
CD
-* Deck
Garage Deck FI1an
Driveway 16 feet wide
12 feet wide
5 feet 6 inches high
12 2X10 joists placed 16" apart
N
W F
SITE PLAN
LARRY ROGERS—NEW DECK
S AUGUST/SEPTEMBER, 2008
f4 RSL/N G /S i4l.GA("VCIM _ 4"nunlnlum clear ,/
I;i
T , -Decking
T 1
/
•
minimum r • ower
,/
J6"
/
plLdmum
V'21'4',11-
«'1 -�,.yicr..i_11 4-11,7-w-.r-,. i..(,.•tf;.,agl;`.I_.�=:.:;,,i1 - ;;,:_r_. •.b.-.t1::•:=i'nl.
I r,; I tl'.•h ,�'� 161�r< ,it t-1 �r( - r'1
c ! h 1 -„r• r}._ aj V 11 t•try r' ::j!• � - ledger anaehment must be bolted through
Decking j i �/ /� y/�/ •y I l
An Imam ov neuter. ��,pH' ���ir A . • A ,�Lt�)! 2X �v (� P�,1 Vl� s eCl n��M
never tlomole edge of ! t. +���t ('
iemLer to sealer of ,1•. • r �''':. (�!/ a� �t 13 !• C,
bolt to be Pia” • _I_ . �i l�l�lloQ �/fil !S e� 1(I:
minimum
tr•:'�' Mader "•• Joist
cli
f Joist it � ) /_ II
!' If elver than 4'-0" 1 (Y
Irgrealer thou 4'-0" 4 .._ lc/0 519(S.rS provide a min.of ,
4n4provide biio■min.or ;il. 4a4 barer al post- /" n �•'•
.b Warne at poet. Sti Ivbew evpnesllvm Relating Dualling ��/ 5uPpoK PDS ! 4 /
. Io-berm connecllone • '�
hlr
'1; (Mulmum poet y
Height shell not be r'� _ 014-0(45C-
„
.f�
Height
s um Foal it, mare hep 10 Rel) 20 M ',r/u S
Heighteheilnot be r( �. T12 ,4fic,D i_]�d 7
mete Wen 10 feel) 1.1.
J/ (•w
GC SitiU 9 Po s`3 5
.ti •
J
�, pPM`r' •
7i . i?I.� ,;. ,y ,.1 Cv.t/C,Q61C. ;77,14
1) rllVll liar— 'I �+�"'t.r�..-u►� Td
A
C,11/4.)NeL710nt
pori yI��IP' t�rl�t�(.(t t`� •
{�� alai basecop Post do Deans Couueulion detail(interior condition)
Iib'•
4” t"min,above concrete or poll Cep Inrlelled per manu(Yotmer'a Inelrucllon
.(.i 1t provide healed wood
� • --_ter!'_—.
6"min (�'. ~•
16"min.
rte It
f,, ' • Inlmum2000pal (4a4)
2411 minimum
'.f 11 r Ls rooting Knee bane
24' minimum. -O. 1�Tv ' :, q i--9e.m
•E1.1.1=:�. + II I
�rlk� ]"minimum `➢4�
I ,e VII141 11 (d
`a� '- 'f Ig"min. 4n4
gi..`-".111- ( ,
Natural Grade
• Two 1/Z"diameter log �: 1-.i Kne}p bnoe
`a4-- 7'min to daylight itr..ef-]Z" bolts lop and bottom typic. r�j Post it
�y4 Deem Cowlecter n detail
Past ail l Ictal basecep poi—�1! 'oq cep Tartar.per menuRcturer's hlrwcdon
•
}}tri I.min.above concrete or
II pre Treatedwood •
IB^min.
ill. 24"man '�'�
;_ Overhang IKnee breve i
t77-0777C y`� 6"minimum I �'�fUlj 11'M 1�••tt., 1� j`} •Ivun
L a u1far
r .V 1. i14 �iY '0. ' ii;��
I000 pal cancrela(minimum r.' '' 'r VV NN"
.r: p
3"minimum .' :�: • 111
24"minimum 16"min.(4n4)Ilbi a
t r i it Knee brims 64 it
i " Ili!�I,y} 1 no l/2^diameter log
�_m bolls lop and buuom I)0.1
Natural Crede
8 PRESCRIPTIVE RESIDENTIAL DECK CONSTRUCTION GUIDE
Figure 8: Post-to-Beam Attachment Figure 9: Prohibited Post-to-Beam Attachment
Requirements Condition
"Mt
(1)3x or 4x or
I1F
(2)2x beam (2) 1/2"diameter lhru-
—notch post to
accomodate beam
RIM JOIST REQUIREMENTS Figure 10: Alternate Approved Post-to-Beam
Attach a continuous rim joist to the ends of joists as Column Cap Attachment
shown in Figure 11.Attach decking to the rim joist as
shown in Figure 11.For more decking attachment
requirements, see DECKING REQUIREMENTS. •
(I„
• • •
. . •
Figure 11: Rim Joi4ACpnnection Details
1!MAH 4 (i
joists secure decking to top of rim joist with
#10 x 3"minimum wood screw @ 6"o.c.
NAILS NOT PERMITTED
•
•
•
•
16...-N„
attach rim joist to end of each joist with (5)#10 x 3"
' ® ; minimum wood screws; NAILS NOT PERMITTED (the
k
number of screws may be reduced to 3 if there is no guard
® or,when a guard post is present,its connection is per
rim joist the GUARD POST ATTACHMENT details)
American Wood Council
PROVIDE DIAGRAMS AND
ENGINEERING LAYOUTS FOR
14( 'r- TRUSSES, BEAMS AND
SYSTEMS PRIOR TO FRAMING
`_ NS
CITY COPY
THIS BUILDING SUBJECT
TO FIELD INSPECTION CORRECTIONS
Siaane
trey
REVIEWED FOR COD COMPLIANCE
SPOKANE VALLEY BU DING ISION