Loading...
2008, 08-26 Permit App: 08003274 Deck Project Number: 08003274 Inv: 1 Application Date: 8/26/2008 Page 1 of 2 THIS IS NOT A PERMIT Penalties will be assessed for commencing work without a permit Project Information: Permit Use: NEW 12 X 16 DECK Contact: MANDERE CONSTRUCTION Address: 13964 N OHIO C-S-Z: RATHDRUM,ID 83858 Setbacks:Front Left: Right: Rear: Phone: (208)687-3308 Group Name: Site Information: Project Name: Plat Key: 000000 Name: Range District: East Parcel Number: 46353.1701 Block: Lot: SiteAddress: 5020 N REES RD Owner:Name: ROGERS,L D&S L Address: 5020 N REES RD Location::CSV SPOKANE VALLEY,WA 99216-304 Zoning: R-3 SF Res District Water District: 001 TRENTWOOD Hold: Area: 10,935 Sq Ft Width: 80 Depth: 136 Right Of Way(ft): 0 Nbr of Bldgs: 1 Nbr of Dwellings: 1 Review Information: .. . maw. .: .. . . ,._. . . Review Building Plan Review Released By: Originally Released: 8/26/2008 By: tmelbourn Landuse/Zoning/HE Conditions Released By: Originally Released: 8/25/2008 By: mpalaniuk Permits: Operator: jmm Printed By: JD Print Date: 8/26/2008 Project Number: 08003274 Inv: 1 Application Date: 8/26/2008 Page 2 of 2 THIS IS NOT A PERMIT Penalties will be assessed for commencing work without a permit Building Permit Contractor: OWNER Firm: OWNER Phone: (000)000-0000 This Application: Total Project: Description Grp Type Notes Sq Ft Valuation Sq Ft Valuation DECK OPEN R-3 VB 192 $2,880.00 192 $2,880.00 Totals: 192 $2,880.00 192 $2,880.00 Item Description Units Unit Desc Fee Amount RESIDENTIAL PERMIT FEE 1 SELECT $83.25 WSBC SURCHARGE 1 SELECT $4.50 SF PLNS RVW<7999 SQ FT 1 SELECT $33.30 Permit Total Fees: $121.05 Payment Summary Permit Type Fee Amount Invoice Amount Amount Paid Amount Owing Building Permit $121.05 $121.05 $0.00 $121.05 $121.05 $121.05 $0.00 $121.05 Disclaimer: Submittal of this application certifies the owner(or person(s)authorized by the owner)has both examined and finds the information contained within to be true and correct,and agrees that all provisions of laws and/or regulations governing this type of work will be complied with. Subsequent issuance of a permit shall not be construed to be a permit for,or an approval of,any violation of any of the provisions of the code or of any other state or local laws or ordinances. Signature: Operator: jmm Printed By: JD Print Date: 8/26/2008 Permit Center - Sn lae - 11703 E Sprague Ave, Su B 3 ��.° Spokane Valley,WA � VALLEY PERMIT NUMBER:, �`r PERMIT FEE: 3� jValleY. (509)688-0036 FAX: (509)688-0037 www.spokanevalley.org 1, 1 2[10b Community Development Residential Construction , 3LCnnstruction Accessory Bldg Permit Application n Addition/Remodel Int: Deck n Other: SITE ADDRESS: 5-0 20 Al. Rees RD, S Kiar� °61\12L ' LOQ 9ctal(P ASSESSORS PARCEL NO: y(p'S3, )1 rll LEGAL DESCRIPTION: 1.1.enrkii e\<Spn Shin LI aa. Building Owner: Contractor: Name: LA pie y p. R 0 G GQs Name: fvE iQ0 FF 6ttA,t/D>E,e£ !/S9' Address: 50.20 /f/. /P GS AD. Address: /3 9 ,1 4/. 4 Hi 0 City: SOOKgv� (/act fiy State:w4 Zip:992,, City: /C/4774 a/QUM State: leD Zip: o Phone: .D f, 9_-G .59C.5 Fax: Phone:_ . G Q7 •3308 Fax: -2d 8 '&(7• 94z4/ Contractor Lic No: Exp Date: Contact Person City Business Lic.No: Name: 1114 . Rer tit S Phone: co q . figgiffsrsi Qat. -3953 Maki()EC. )'IDSDP Describe the scope of work in detail: Cost of Project: $ 3 5OO.00 7-44 R. J'vud.1/ 'L2 2 *' 4-7t/A Q£P.Ac G W ,r7/ A ,Wed at/- Proposed Use: PC oAmL - at ,Av(. , 5crftimi6 , i44-z,fide, **************The following MUST be complete: (write N/A if not applicable)********************** HEIGHT TO PEAK: DIMENSIONS: #OF STORIES: TOTAL HABITABLE SPACE: /V/A N� /or X /4 A//4 4/ II MAIN FLOOR TO SQ. 2 FLOOR SQ. FTG: UNFIN BASEMENT SQ. FTG: IMPERVI US SURFACE FTG: /A //� P /WA AREA: ou/4 FINISHED BAS MENT GARAGE SQ. FTG: DEC . • • ' = 0. FTG: 30% SLOPES ON n SQ. FTG: /l/ A /(,/d) /9.2 a' - PROPERTY: 4//T #OF BEDR OMS: CONSTRUCTION TYPE: •- - •UR ' SEWER OR SEPTIC? n//A /e iPasr ,h4 /9 -Sftelte The permitee verifies, acknowledges and agrees by their signature that: 1) If this permit is for construction of or on a dwelling,the dwelling is/will be served by potable water. 2) Ownership of this City of Spokane Valley Permit inure to the property owner. 3) The signatory is the property owner or has permission to represent the property owner in this transaction. 4) All construction is to be done in full compliance with the City of Spokane Valley Development Code. Referenced codes are available for review at the City of Spokane Valley Permit Center. 5) This City of Spokane Valley Permit is not a permit or approval for any violation of federal, state or local laws,codes or ordinances.6) Plans or additional information may be required to be submitted, and subsequently approved before this application can be rocessed. SIGNATURE: DATE: $-11-0g Method of Payment: ❑ Cash ❑ Check ❑ Mastercard ❑ VISA Bankcard#: Expires: VIN#: Authorized Signature: REVISED 2/15/07 RESIDENTIAL CHECK LIST DIRECTIONS: Place a check mark in box next to each document required for complete submittal. ❑ SITE PLAN o Property lines and dimensions o Setbacks to property lines ❑ Direction arrow pointing North and orientation to streets o Distance between buildings o Proposed/existing buildings (footprint and dimensions) o Right of way/easement location &sizes o Utilities, septic tank/drain field locations and distances o Driveway approach size and location BUILDING PLANS (3 SETS) (minimum 1/8 inch scale or completely dimensioned) ❑ Elevations (Front/Rear/Sides)with roof peak and wall height including basement: ❑ Foundation Plan (crawlspace, basement or slab on grade): o Footing sizes and locations o Supporting wood cripple walls or beams o Perimeter concrete foundation wall sizes o Thickened concrete pads supporting o Crawlspace ventilation beams or girder trusses ❑ Floor Plan of each level (finished or unfinished)with dimensions: o Floor Joist direction, size and spacing o Window and door location and sizes o Header, beam or concrete lintel sizes o Window well locations if applicable o Brace wall panel locations o Room usage labels o Water heater and furnace locations o Smoke detector locations o Exhaust fan locations o Attic and crawl space access locations o Deck or concrete patio sizes and locations o Fire Wall construction ❑ Roof Plan: o Engineered truss direction and spacing o Ridge, eave and valley lines o Rafter and over frame direction, size and spacing o Beam and girder size and location ❑ Wall Section Detail including: Roof o Slope/roofing material/underlayment/ice dam protection o Truss or rafter size, spacing &connection ❑ Sheathing size and type ❑ Attic insulation/air space baffle/ventilation Ceiling o Joist size and spacing ❑ Size of ceiling gypsum wall board Wall o Height/top plate/stud size and spacing/sole plate o Siding/exterior house wrap/anchor bolts o Exterior sheathing size and type ❑ Insulation, vapor barrier, gypsum wall board Floor o Joist size and spacing ❑ Sheathing or concrete floor size/insulation Foundation Wall ❑ Concrete or Masonry unit width ❑ Footing bottom to finished ground level depth o Earth to wood separation distance o Horizontal &vertical reinforcement if any Footing o Size ❑ Reinforcement if any Radon o Passive system with 6mil vapor barrier ❑ Active system with 6 mil vapor barrier Miscellaneous Construction Details g Deck: %Floor plan/side view/dimensions Footings/post/and beam size and locations ig.Floor Joist/decking direction, size and spacing 0 Stairway tread rise &run and nosing 10 Handrail/Guard height &spacing 1' Pro• ec l- New project El TY 1 , New pre-app meeting El o P ne Transmittal Plan revisions City of Spokane Valley Transmittal Date: ...•O'Valley Community Development Thursday,August 21,2008 Department 11703 E.Sprague Ave,Suite B3 Spokane Valley,WA 99206 Phone:509.688.0036 Site Address: 5020 N REES RD Project Number: 08003274 Parcel Number: 46353.1701 Zoning: R-3 Water District: TRENTWOOD Fire District: FD 01 Applicant: MANDERE CONSTRUCTION Owner: ROGERS, L D & S L 13964 N OHIO 5020 N REES RD RATHDRUM, ID 83858 SPOKANE VALLEY, WA 99216-304 (208) 687-3308 e-mail: e-mail: Contact: MANDERE CONSTRUCTION Occupant: 13964 N OHIO e-mail: RATHDRUM, ID 83858 (208) 687-3308 e-mail D L F I I r� M i l--� FE Contractor: MANDERE CONSTRUCTION INC Arch/Engineer: 13694 N OHIO ST 1m- AU:.; i 3 %.(ri RATHDRUM, ID 83858 D) if� (509) 891-6096 D) -11L- L - B n I 5 e-mail: it Project NEW 12 X 16 DECK Description: Building Landuse Engineer Utilities Health Fire Dist Assessor APPLICATION CONSTRUCTION PLANS i SITE PLAN ` ) TDS Please send all plan review and project comments via e-mail to the highlighted individuals. • For City Use Only CITY OF .:. PLUS Project Number -)2.----,1 Spokane Project Address O Q g� 5 Z ,y Valle ° y 11703 E Sprague Ave Suite B-3 ♦ Spokane Valley WA 99206 509.688.0036 ♦ Fax: 509.688.0037 ♦ permitcenter@spokanevalley.org As part of our on-going commitment to customer service during the review process of your project application, we are providing you with a TARGET DATE for the initial technical application review. If for any reason we cannot meet this date, we will contact you with a revised target date. Your application review TARGET DATE is -6 0:1 \ O`�° The TARGET DATE is the date we estimate your project application will have had its initial technical review. It is not the date for approval or permit issuance. Tips for a Smoother Project Application Review ➢ Submit complete, accurate plans and documents. Extra time may be required for re-submittals as project application reviewers work on multiple applications and it may be several days before they can look at your new or revised information. > Designate a specific contact person to communicate with the City. While the person designated as the applicant's contact person with the City can be changed, one individual with the expertise for dealing with reviewer comments would be the best choice for the entire review process. > Call staff regarding the status of your project only after the target date shown at the top of the page. Although you should be contacted on or by the target date,please feel free to contact us if you haven't heard from us by your target date. Staff may contact you before the target date if the initial review is complete. By following this procedure,you will save time and allow the reviewers to complete the work more expeditiously. Steps in the Permit Process 1. Counter Complete. Your application has been accepted as counter complete. This means all of the required documents, as indicated on your Pre-Application Checklist have been submitted or have been approved for deferred submittal. This does not prevent technical staff from requesting additional information as a result of their technical review. 2. Quality Check. The next step in the process is a quality check to make sure that the application is reviewable and free from substantive flaws that would prevent technical staff from completing the technical review once it is started. When this step is complete, your application will be routed to the appropriate staff and remain in their review queue until it comes up for review. 3. Technical Compliance. Once an application is administratively complete, it is routed to technical staff for compliance review. Depending on the type of project, technical staff may include multiple reviewers. You should be contacted by phone,fax, email,or mail by your TARGET DATE once the initial technical compliance review is complete. 4. Permit Issuance. When the technical compliance review of the application is complete, including any subsequent re- submittals, each reviewer will approve their section of the application and route it to the Permit Center. When all sections of the application are received, a Permit Specialist will process the application and contact the person specified on your application for permit pick-up. Information regarding fees and pre-construction meetings (if required) will be provided by the Permit Specialist at that time. WHITE—APPLICANT PINK—BUILDING FILE REV 9/07 • 46' north edge of deck to north side — Wabash Road of property Road Sign •zir a' Fire Hydrant Sewer Location Land Size 10,935 sq. ft. PLAN NTNG DEPT. AP• •OVER • House—28' 6" depth BY „ DA'E: '2// 461 czt - V) CL) 0 (24 Tree 3 v, Shed 14) cD CD C) n Deck Plan 16 feet wide 57' deck edce to hack of lot 12 feet wide 71. 5 feet 6 inches high Deck 12 2X10 joists placed 16" apart • • AL cu bu bA 59' front of lot to deck edge Driveway c.7 o Garage 25' depth 0 28' south side of deck to south side of property N T W F SITE PLAN LARRY ROGERS—NEW DECK AUGUST/SEPTEMBER,2008 a . Wabash Road Road Sian a Fire Hydrant Sewer Location T,and Size 10.915 soft. House 3 --� Shed a) Tree b 0 N CD c� T1 CD CD CD -* Deck Garage Deck FI1an Driveway 16 feet wide 12 feet wide 5 feet 6 inches high 12 2X10 joists placed 16" apart N W F SITE PLAN LARRY ROGERS—NEW DECK S AUGUST/SEPTEMBER, 2008 f4 RSL/N G /S i4l.GA("VCIM _ 4"nunlnlum clear ,/ I;i T , -Decking T 1 / • minimum r • ower ,/ J6" / plLdmum V'21'4',11- «'1 -�,.yicr..i_11 4-11,7-w-.r-,. i..(,.•tf;.,agl;`.I_.�=:.:;,,i1 - ;;,:_r_. •.b.-.t1::•:=i'nl. I r,; I tl'.•h ,�'� 161�r< ,it t-1 �r( - r'1 c ! h 1 -„r• r}._ aj V 11 t•try r' ::j!• � - ledger anaehment must be bolted through Decking j i �/ /� y/�/ •y I l An Imam ov neuter. ��,pH' ���ir A . • A ,�Lt�)! 2X �v (� P�,1 Vl� s eCl n��M never tlomole edge of ! t. +���t (' iemLer to sealer of ,1•. • r �''':. (�!/ a� �t 13 !• C, bolt to be Pia” • _I_ . �i l�l�lloQ �/fil !S e� 1(I: minimum tr•:'�' Mader "•• Joist cli f Joist it � ) /_ II !' If elver than 4'-0" 1 (Y Irgrealer thou 4'-0" 4 .._ lc/0 519(S.rS provide a min.of , 4n4provide biio■min.or ;il. 4a4 barer al post- /" n �•'• .b Warne at poet. Sti Ivbew evpnesllvm Relating Dualling ��/ 5uPpoK PDS ! 4 / . Io-berm connecllone • '� hlr '1; (Mulmum poet y Height shell not be r'� _ 014-0(45C- „ .f� Height s um Foal it, mare hep 10 Rel) 20 M ',r/u S Heighteheilnot be r( �. T12 ,4fic,D i_]�d 7 mete Wen 10 feel) 1.1. J/ (•w GC SitiU 9 Po s`3 5 .ti • J �, pPM`r' • 7i . i?I.� ,;. ,y ,.1 Cv.t/C,Q61C. ;77,14 1) rllVll liar— 'I �+�"'t.r�..-u►� Td A C,11/4.)NeL710nt pori yI��IP' t�rl�t�(.(t t`� • {�� alai basecop Post do Deans Couueulion detail(interior condition) Iib'• 4” t"min,above concrete or poll Cep Inrlelled per manu(Yotmer'a Inelrucllon .(.i 1t provide healed wood � • --_ter!'_—. 6"min (�'. ~• 16"min. rte It f,, ' • Inlmum2000pal (4a4) 2411 minimum '.f 11 r Ls rooting Knee bane 24' minimum. -O. 1�Tv ' :, q i--9e.m •E1.1.1=:�. + II I �rlk� ]"minimum `➢4� I ,e VII141 11 (d `a� '- 'f Ig"min. 4n4 gi..`-".111- ( , Natural Grade • Two 1/Z"diameter log �: 1-.i Kne}p bnoe `a4-- 7'min to daylight itr..ef-]Z" bolts lop and bottom typic. r�j Post it �y4 Deem Cowlecter n detail Past ail l Ictal basecep poi—�1! 'oq cep Tartar.per menuRcturer's hlrwcdon • }}tri I.min.above concrete or II pre Treatedwood • IB^min. ill. 24"man '�'� ;_ Overhang IKnee breve i t77-0777C y`� 6"minimum I �'�fUlj 11'M 1�••tt., 1� j`} •Ivun L a u1far r .V 1. i14 �iY '0. ' ii;�� I000 pal cancrela(minimum r.' '' 'r VV NN" .r: p 3"minimum .' :�: • 111 24"minimum 16"min.(4n4)Ilbi a t r i it Knee brims 64 it i " Ili!�I,y} 1 no l/2^diameter log �_m bolls lop and buuom I)0.1 Natural Crede 8 PRESCRIPTIVE RESIDENTIAL DECK CONSTRUCTION GUIDE Figure 8: Post-to-Beam Attachment Figure 9: Prohibited Post-to-Beam Attachment Requirements Condition "Mt (1)3x or 4x or I1F (2)2x beam (2) 1/2"diameter lhru- —notch post to accomodate beam RIM JOIST REQUIREMENTS Figure 10: Alternate Approved Post-to-Beam Attach a continuous rim joist to the ends of joists as Column Cap Attachment shown in Figure 11.Attach decking to the rim joist as shown in Figure 11.For more decking attachment requirements, see DECKING REQUIREMENTS. • (I„ • • • . . • Figure 11: Rim Joi4ACpnnection Details 1!MAH 4 (i joists secure decking to top of rim joist with #10 x 3"minimum wood screw @ 6"o.c. NAILS NOT PERMITTED • • • • 16...-N„ attach rim joist to end of each joist with (5)#10 x 3" ' ® ; minimum wood screws; NAILS NOT PERMITTED (the k number of screws may be reduced to 3 if there is no guard ® or,when a guard post is present,its connection is per rim joist the GUARD POST ATTACHMENT details) American Wood Council PROVIDE DIAGRAMS AND ENGINEERING LAYOUTS FOR 14( 'r- TRUSSES, BEAMS AND SYSTEMS PRIOR TO FRAMING `_ NS CITY COPY THIS BUILDING SUBJECT TO FIELD INSPECTION CORRECTIONS Siaane trey REVIEWED FOR COD COMPLIANCE SPOKANE VALLEY BU DING ISION