2011, 03-07 Duct Leakage Affidavit
Energy Code Support V\AS 11Ni.1FON5 AT1.t1NIVE.lt'I]V Permit #: //- Oolag Duct Leakage Affidavit House address or lot number: / / 707 kv ✓frc 'f Lei City: 5e, k t,Q V14 del Cond. Floor Area (ft2): a 3 / 1 Zip: qqA o 6. Source (circle one): (lar ) Estimated Measured ❑ Duct tightness testing is not required for this residence per exceptions listed at the end of this document Air Handler in conditioned space?g[,yes ❑ no Air Handler present during test? Kyes ❑ no Circle Test Method: Leakage to Outside otal Lea ca Maximum duct leakage: Post Construction, total duct leakage: (floor area x .08) = CFM©25 Pa Post Construction, leakage to outdoors: (floor area x .06) = CFM@25 Pa Rough -In, total duct leakage with air handler installed: (floor area x .06) = / . PCFM@25 Pa Rough-ln, total duct leakage with alr handler not installed: (floor area x .04) = CFM©25 Pa Test Result: Jr2 CFM@25Pa Ring (circle one if applicable):blOpen Duct Tester Location: / 2lliA"ri 4) c O( I certify that these duct leakage rates are Company Name: 1 2 3 Pressure Tap Location: —� r5,1 ?Ay accurate and determined usi�ngg standard duct testing protocol. Technician: ,(.5177 �C� / 144/4 GIjG� Technician Signat61e: I (31-? Date: 3:7— /1 Phone Number: «.y -i Y) S Washington State Energy Code reference: 503.10.3 Sealing. All ducts, air handlers, filter boxes, and building cavities used as ducts shall be sealed. Joints and seams shall comply with Section M1601.3 of the International Residential Code or 603.9 of the International Mechanical Code. Duct tightness testing shall be conducted to verify that the ducts are sealed. A signed affidavit documenting the test results shall be provided to the jurisdiction having authority by the testing agent. When required by the building official, the test shall be conducted in the presence of department staff. Exceptions: 1. Duct tightness test is not required if the air handler and all ducts are located within conditioned space. 2. Duct testing is not required if the furnace is a nondirect vent type combustion appliance installed in an unconditioned space. A maximum of six feet of connected ductwork in the unconditioned space is allowed. All additional supply and return ducts shall be within the conditioned space. Ducts outside the conditioned space shall be sealed with a mastic type duct sealant and insulated on the exterior with R-8 insulation for above grade ducts and R-5 water resistant insulation when within a slab or earth. �0wFie Ooc y mc -r- 3-31-1 104 % (! _7S, eFr„ 5-0 y•oS5)/(A311 cfA)r. g) 76s-r01s/230?'IPy ,00aall