1974, 09-25 Permit App: K5893 Residence County of Spokane, Washington
BUILDING CODES DEPARTMENT, COURTHOUSE, SPOKANE, WASHINGTON 99201
i APPLICATION FOR LAND USE OR STRUCTURE PERMIT ,
�
GENERAL REQUIREMENTS PERMIT FEE r ")r
PERMIT REQUIRED. A land use or structure permit is required by County Resolution to erect a building or structure of any
kind or alter any building or structure already erected, or to change a land use. Construction must conform with the
Spokane County Building Code and Zoning Ordinance. Construction is subject to inspection.
WATER. Water supply must be approved by the County and State Health Departments. Where work on water connections disturbs
the surface, shoulders or ditches of County Roads, permission must be obtained from the County Engineer's Office.
SEWAGE SYSTEM. Permits are required in all cases by County Resolutions Nos, 45-133 and 47.235.
SET-BACK FROM PROPERTY LINES. In most zones and under most circumstances, a set-back from the front property line, of at
least 25' is required, a 5' side yard, 15' side yard from a flanking street, and a 25' rear yard are required.
STATE HIGHWAYS. Where the structure abuts a State Highway, clearance must be obtained pertaining to set-back and ingress
and egress.
COUNTY ROADS. Work on street right-of-way may not be performed until staked by County Road Department and work must be
performed in accordance with stakes. Points of ingress and egress must be approved by the County Engineer.
MOVING OF BUILDINGS. A permit is required to move an existing building. When a building is moved on a County or State
Highway clearance must be obtained from the County Engineer and/or State Highway Department.
ACCESS Y BUILDINGS. Accessory buildings (garages, sheds, etc.) require a separate permit.
RESTRI TIVE COVENANTS. Builders should check provisions of covenants or dedications and easements running with the land
which re enforceable through civil action. County Officials can not bring action to enforce covenants or dedications.
APPLICANT FILL IN BELOW THIS LINE
Name of Owner Kappen Construction, Inc. Address 2312 N. Pines Road Phone 928.86. 0
Aehitect_ Phone Engineer Phone
Contractor Kappen Construction, Inc. Address 2312 N. Pines Road Phone '...'"
Legal Description of Property (Give complete description from deed, tax receipt, etc.) _
_ Lot 8 Blk._ 3 Wellelsey Manor Second Addition
b v 11�- _ i o -- --- --
DESCRIPTION OF WORK:New X Addition Remodel_ Moving ..Bldg.Zone__._.,LFire Zone .27
Size of Lot qc X 142 _ Sewage System Septic tankStories l 2
Const. frame Dimensions 40 x 25 x 22 X 24 _Total Sq.Ft.2008 Valuation33'750.00
(Frame,concrete,brick,etc.)
Rooms 6 Baths 2 _Basement full Foundation Const. concrete _ .Chimney brick Fireplace two
(Full, part, none) (Kind) (Number)
Heat. System_ Electric _Type of Roofing OMP _ Ext. Finish Wood Int. Wall FinishgypSUM brd•
Use of Bldg.Residence No. of Units 1 Bedrooms 4
Garage or Carport Attached attached garage
g' P Private llctatched
PLOT PLAN
Draw sketch with dimensions showing: (I) property lines; (2) street or road locations; (3) location of existing and
proposed buildings; (4) distance to property lines and s (5) dimensions of buildings; (6) location of sewage sys-
tem and water supply lines.
NORTH c.- State icense No.
Ind. Ins. Acct. No.
12 C / — 74_
see attached
REQUIRED
Main floor 1000 sq. ft. Plumbing Pe it
* garage 528 sq, ft. m Heating Permit
w Basement 480 sq. ft. ,P Sewage Permit
-1 2008 sq. ft. -1
Plans Re •'••.
Plans Chec.
III Plans Returned
Plans Picked Up
Plans Mailed
SOUTH
I hereby c ify in.€ormation s mitted is correct and there are no other structures located on this property except
as shown. L 4 / &, , September 25, 1974
Owner or Agent Date
A LAND USE OR STRUCTURE PERMIT MUST BE ON THE PREMISES BEFORE CONSTRUCTION COMMENCES.
THIS IS NOT A PERMIT.
(.9-A-1- 1,14c0^ 0 DO NOT WRITE BELOW THIS LINE I e
Your M5—vetm,.?ddress will be �� ��� c, A V e zone is !1 SI T
--,,
Sewage Permit Number Issued Building Permit `' ceipt c4 if Issued - .
Remarks
Form 523 Bldg. Code . s
a
7
1
KAPPEN CONSTRUCTION, INC.
2312 N. Pines Road 0L
Spokane, Washington 99216 Requested Price S57, 17- 0.
Wa 4-0771 Lot Cost $3 , 750 . 00
PLOT PLAN
RICH AVENUE 1 ELEVATIONS:
TN ' Crown of Street
0, 95 ' I
= Finish Floor v''/,!.' 7
GlyiT --
�' ,,:\
\ \ A
5 Y concret . A 4
drive i
30'-
f
P °'
.1 czi
4-2" walkway --
1 ft . verh ,-- , -142 `_ fc-h �o'
4tlT 22-1 HOUSE
0 13 , FOUNDATION 24,,x4()24,,x4()4
Basic 1400 Dbl . gar . 1 FT. OVERHANG ON
HOUSE .
FF = `7CV C'1.1 .t��J 1 N i GARAGE 24x22
: ,s; 62 '- IqD
17_1000 gal .
12 ' 12 ' 12 '
N - - -
I
r-+ , 1
i
- � - - fi
r-1 r-1 r-1
.� I ,
i I f i 1
I
•
,0. 95 '
Scale: 1" = 20.'
Basic: 1400 T Sg. Ft. 1400 ; Legal Lot 8 , Block 3, Wellesley Manor Second Add .
FHA Case # ; Job # L -
195 Address: Rich Avenue
r-
Mortgage Co. SFR SPECIAL INSTRUCTIONS: St . Gable Roof, Cath .
Power Co. ,Dishwasher
Water Co.
WWP : Trentwood Double Car Garage (22x24)
4 2 fireplaces
P1 umber : Excavator Brick veneer
L. Harty 1 o s a u g h 2 had r nems hal 1_