Loading...
2005, 11-07 Permit App: 05004070 Fire Damage RepairProject Number: 05004070 Inv: 1 Application Date: 11/07/2005 Page 1 of 2 THIS IS NOT A PERMIT Penalties will be assessed for commencing work without a permit Proiect Information: Permit Use: REPAIR FIRE DAMAGE Contact: COVINGTON CONSTRUCTION Address: 1324 LIBERTY LAKE RD #224 C - S - Z: LIBERTY LAKE, WA 99109 Setbacks: Front 39 Left: 20 Right: 10 Rear: 63 Phone: (509) 891-0056 Group Name: Site Information: Project Name Plat Key: Name: VERA District: Nort Parcel Number: 45154.3102 Block: Lot: SiteAddress: 13811 E RIVERSIDE AVE Owner: Name: STILL, RICK L Location:: CSV Zoning: UR -7 Urban Residential -7 Water District: Area: 10,862 Sq Ft Width: 0 Nbr of Bldgs: 0 Nbr of Dwellings: 0 Review Information: Review Site Plan Review Plan Review Permits: _ Address: 13811 E RIVERSIDE SPOKANE VALLEY, WA 99216 Hold: ❑ Depth: 0 Right Of Way (ft): 0 Originally Released: 11/04/2005 By: CJJANSSE Originally Released: 11/07/2005 By: TMELBOU Operator: CJJ Printed By: CJJ Print Date: 11/07/2005 Project Number: 05004070 Inv: l Application Date: 11/07/2005 Page 2 of 2 THIS IS NOT A PERMIT Penalties will be assessed for commencing work without a permit Contractor: COVINGTON CONSTRUCTION Address: 1324 LIBERTY LAKE RD #224 LIBERTY LAKE, WA 99109 Description Grp RESIDENCE R-3 Item Description RESIDENTIAL PERMIT FE STATESURCHARGE RESIDENTIAL PLAN REVI Building Permit -- --- Firm: COVINGTON CONSTRUCTION Phone: (509) 891-0056 This Application: Valuation $65,000.00 E Tyne Notes Sq Ft VB FIRE 0 REPAIR Totals: 0 Units Unit Desc E 1 SELECT 1 SELECT W 1 SELECT Contractor: COVINGTON CONSTRUCTION Address: 1324 LIBERTY LAKE RD #224 LIBERTY LAKE, WA 99109 $65,000.00 Total Project: Sg Ft Valuation 0 $65,000.00 0 $65,000.00 Fee Amount $748.75 $4.50 $299.50 Permit Total Fees: $1,052.75 Plumbing Permit Firm: COVINGTON CONSTRUCTION Phone: (509) 891-0056 Item Description Units Unit Desc Fee Amount TOILETS/BIDETS 1 NUMBER OF $6.00 SINKS 2 NUMBER OF $12.00 TUBS 1 NUMBER OF $6.00 GARBAGE DISPOSAL 1 NUMBER OF $6.00 Permit Total Fees: $30.00 Notes: _=.a. ... Payment Summary:� Permit Type Fee Amount Invoice Amount Amount Paid Amount Owing Building Permit $1,052.75 $1,052.75 $0.00 $1,052.75 Plumbing Permit $30.00 $30.00 $0.00 $30.00 $1,082.75 $1,082.75 $0.00 $1,082.75 Disclaimer: Submittal of this application certifies the owner (or person(s) authorized by the owner) has both examined and finds the information contained within to be true and correct, and agrees that all provisions of laws and/or regulations governing this type of work will be complied with. Subsequent issuance of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the code or of any other state or local laws or ordinances. Signature: Operator: CJJ Printed By: CJJ Print Date: 11/07/2005 Notes: _=.a. ... Payment Summary:� Permit Type Fee Amount Invoice Amount Amount Paid Amount Owing Building Permit $1,052.75 $1,052.75 $0.00 $1,052.75 Plumbing Permit $30.00 $30.00 $0.00 $30.00 $1,082.75 $1,082.75 $0.00 $1,082.75 Disclaimer: Submittal of this application certifies the owner (or person(s) authorized by the owner) has both examined and finds the information contained within to be true and correct, and agrees that all provisions of laws and/or regulations governing this type of work will be complied with. Subsequent issuance of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the code or of any other state or local laws or ordinances. Signature: Operator: CJJ Printed By: CJJ Print Date: 11/07/2005 Project Number: 05004070 Inv: I Application Date: 11/04/2005 Page 1 of 2 THIS IS NOT A PERMIT Penalties will be assessed for commencing work without a permit Proiect Information: Permit Use: REPAIR FIRE DAMAGE Contact: COVINGTON CONSTRUCTION Address: 1324 LIBERTY LAKE RD #224 C - S - Z: LIBERTY LAKE, WA 99109 Setbacks: Front 39 Left: 20 Right: 10 Rear: 63 Phone: (509) 891-0056 Group Name: Site Information. Project Name Plat Key: Name: VERA District: Nort Parcel Number: 45154.3102 Block: Lot: SiteAddress: 13811 E RIVERSIDE AVE Owner: Name: STILL, RICK L Location:: CSV Address: 13811 E RIVERSIDE SPOKANE VALLEY, WA 99216 Zoning: UR -7 Urban Residential -7 Water District: Hold: ❑ Area: 10,862 Sq Ft Width: 0 Depth: 0 Right Of Way (ft): 0 Nbr of Bldgs: 0 Nbr of Dwellings: 0 Review Information: Review Site Plan Review Released By: Originally Released: 11/04/2005 By: CJJANSSE Plan Review Released By: Permits: _. Building Permit — - — Contractor: COVINGTON CONSTRUCTION Firm: COVINGTON CONSTRUCTION Address: 1324 LIBERTY LAKE RD #224 Phone: (509) 891-0056 LIBERTY LAKE, WA 99109 Description Grp Type Notes RESIDENCE R-3 VB FIRE REPAIR Totals: Operator: CJJ Printed By: CJJ This Application: Sq Ft Valuation 0 $65,000.00 0 $65,000.00 Print Date: Total Project: Sg Ft Valuation 0 $65,000.00 0 11/04/2005 $65,000.00 Project Number: 05004070 Inv: I Application Date: 11/04/2005 Page 2 of 2 THIS IS NOT A PERMIT Penalties will be assessed for commencing work without a permit Notes: ;:,.a, ... Payment Summary Disclaimer: Submittal of this application certifies the owner (or person(s) authorized by the owner) has both examined and finds the information contained within to be true and correct, and agrees that all provisions of laws and/or regulations governing this type of work will be complied with. Subsequent issuance of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the code or of any other state or local laws or ordinances. Signature: Operator: CJJ Printed By: CJJ Print Date: 11/04/2005 Project Number: 05004070 Inv: 1 Application Date: 10/27/2005 Page 1 of 1 THIS IS NOT A PERMIT Penalties will be assessed for commencing work without a permit Project Information: . . Permit Use: REPAIR FIRE DAMAGE Contact: COVINGTON CONSTRUCTION Address: 1324 LIBERTY LAKE RD #224 C - S - Z: LIBERTY LAKE, WA 99109 Setbacks: Front Left: Right: Rear: Phone: (509) 891-0056 Group Name: Site Information: Project Name: Plat Key: Name: VERA District: Nort Parcel Number: 45154.3102 Block: SiteAddress: 13811 E RIVERSIDE AVE Location:: CSV Zoning: UR -7 Urban Residential -7 Water District: Area: 10,862 Sq Ft Width: 0 Nbr of Bldgs: 0 Nbr of Dwellings: 0 Review Information: Lot: Owner: Name: STILL, RICK L Address: 13811 E RIVERSIDE SPOKANE VALLEY, WA 99216 Hold: ❑ Depth: 0 Right Of Way (ft): Permits: Building Permit Contractor: COVINGTON CONSTRUCTION Firm: COVINGTON CONSTRUCTION Address: 1324 LIBERTY LAKE RD #224 Phone: (509) 891-0056 LIBERTY LAKE, WA 99109 This Application: Total Project: Description Grp Type Notes Sq Ft Valuation Sp Ft Valuation RESIDENCE R-3 VB FIRE 0 $65,000.00 0 $65,000.00 REPAIR Totals: 0 $65,000.00 0 $65,000.00 Notes Payment Summary Disclaimer: Submittal of this application certifies the owner (or person(s) authorized by the owner) has both examined and finds the information contained within to be true and correct, and agrees that all provisions of laws and/or regulations governing this type of work will be complied with. Subsequent issuance of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the code or of any other state or local laws or ordinances. Signature: Operator: CJJ Printed By: CJJ Print Date: 10/27/2005 Permit Center pOe 11707 E Sprague Ave, Suite 106 :F ValleSpokane Valley, WA 99206 �F (509)688-0036 FAX: (509)688-0037~ Community Development www.spokanevalley.orz.com. Residential Construction ❑ New Construction ❑ Accessory Bldg Permit Application ❑ Addition/Remodel ❑ Deck a Other: A'/•,o c ar f a fir e SITE ADDRESS / 5, fit/ f ivlr t ASSESSORS PARCEL NO: 1 31 S" V 3/0Z- LEGAL DESCRIPTION: -�r'— �� Name: c kj Address: city: -S;'44r&e P% l/t zip: 2 Phone: f Fax Name: Co✓% fal - Phone: N 3 JF Describe the scope of work in detail: Cost of Project: I $ �S� �� • I . **************The following MUST be complete: (write N/A if not HEIGHT TO PEAK: Name: Cod/ iow Cons f Address: MAIN FLOOR TO SQ. FTG: city: G. L. zip: Phone: Y p%GV,10 Fax: OOf Lie No te: 419 ©10 City Business Lic No: CONSTRUCTION TYPE: Cost of Project: I $ �S� �� • I . **************The following MUST be complete: (write N/A if not HEIGHT TO PEAK: DIMENSIONS: # OF STORIES: TOTAL HABITABLE SPACE: MAIN FLOOR TO SQ. FTG: 2 NLFLOOR SQ. FTG: UNFIN BASEMENT SQ. FTG: IMPERVIOUS SURFACE AREA: FINISHED BASEMENT SQ. FTG: GARAGE SQ. FTG: DECK/COV. PATIO SQ. FTG: 30% SLOPES ON PROPERTY: # OF BEDROOMS: CONSTRUCTION TYPE: HEAT SOURCE: SEWER OR SEPTIC? v��a,vynn�r� The permitee verifies, acknowledges and agrees by their signature that: 1) If this permit is for construction of or on a dwelling, the dwelling is/will be served by potable water. 2) Ownership of this City of Spokane Valley Permit inure to the property owner. 3) The signatory is the property owner or has permission to represent the property owner in this transaction. 4) All construction is to be done in full compliance with the City of Spokane Valley Development Code. Referenced codes are available for review at the City of Spokane Valley Permit Center. 5) This City of Spokane Valley Permit is not a permit or approval for any violation of federal, state or local laws, codes or ordinances. 6) Plans or additional information may be required to be submitted, and subsequently approved before #tit"P!i-eatiar . Signature Method of Payment ❑ Cash Bankcard #: Date (Faxed permit applications will only be accepted with major bankcard) ❑ Check ❑ Mastercard ❑ VISA ❑ Other Authorized Signature: REVISED 8252OD5 Expires: VIN#: Spo"kan'� ems' vley Community Development Plumbing Permit SITE ADDRESS: Permit Center 11707 E Sprague Ave, Suite 106 PERMIT NUMBER: Spokane Valley, WA 99206 (509)688-0036 FAX: (509)688-0037 PERMIT FEE: www.spokaneyalley.org.con nnlication n Commercial Residential Building owner DESCRIPTION OF WORK Name: Phone: Fax: Address: City: State: Zip: Contractor TOTAL AMOUNT Name: Phone: Fax: Address: City: State: Zip: License No: -City Business License No: Contact Name: Phone: AUTHORIZED SIGNATURE: REVISED 8/25/05 DESCRIPTION OF WORK # OF UNITS X COST = TOTAL AMOUNT 1 TOILETS WATER CLOSET, BIDETS X $6.00 = 2 URINALS X $6.00 = 3 TUBS X $6.00 = 4 SHOWERS PER TRAP BATH, STALL, ON-SITE BUILT X $6.00 = 5 SINKS LAVS/BASINS, BAR, FLOOR, KITCHEN, LAUNDRY, UTILITY, JANITOR, PHOTO, X-RAY, FOOD, PREP/CULINARY MEAT X $6.00 = 0 6 DISHWASHER X $6.00 = 7 CLOTHES WASHER Xg$600 = 8 GARBAGE DISPOSAL X 9 WATER SOFTENER X= 10 ELECTRIC HOT WATER TANK NOTE: IF GAS, SEE MECHANICAL X= 11 FLOOR DRAINS AREA, CASE, COIL, TRENCH, CONDENSATE X $6.00 = 12 ROOF DRAINS/OVERFLOW DRAINS X $6.00 = 13 FOUNTAINS, DRINKING X $6.00 = 14 WATER PIPING/DRAIN-IN WASTE, VENT, PLUMBING, REVERSAL NSTALLATION, ALTERATION, REPAIR, REVERSALS X $6.00 = 15 SEWAGE EJECTOR GRINDER, SUMP PUMP X $6.00 = 16 WATER USING DEVICE ICE AN/OR COFFEE MAKER, HOSE BIB, STEAMER PROOFER, CARBONATOR, SWAMP COOLER X $6.00 = 17 CROSS CONNECTION DEVICE VACUUM BREAKER, CHECK VALVE, AND R.P.B.P.D. FOR: VATS, TANKS, BOILERS X $6.00 = 18 INTERCEPTORS GREASE TRAP, SAND TRAP, CHEMICAL HOLDING TANK X $6.00 = 19 MEDICAL GAS r outlet NITROUS, OXYGEN X $6.00 = 20 MISCELLANEOUS PLUMBING FIXTURE X $6.00 = 21 PRIVATE SEWAGE DISPOSAUSYS X $20.00 22 INDUSTRIAL WASTE INTERCEPTOR X $15.00 = METHOD OF PAYMENT: ❑ CASH ❑ CHECK ❑ VISA ❑ MASTERCARD Card# EXPIRES: SUBTOTAL Q• �%v PROCESSING FEE $35.00 TOTAL PERMIT FEE DUE: L AUTHORIZED SIGNATURE: REVISED 8/25/05 SATE pLA/Y ,� _-20'Y r c. s4 'alc 3�-` i Rs�:•r��� yrs Covinigronese consrrrucrion 1rresrorarion.na PROPERTY OWNER Rick Still 13 811 E Riverside Ave Spokane Valley WA 99216 CONTRACTOR Covington Construction & Restoration LLC 1324 Liberty Lake RD. # 224 Liberty Lake WA. 99019 Damage was caused by fire. Work to include, new drywall through out, insulation, vinyl windows, cabinets, plumbing fixtures & electrical. New wall framing at exterior garage walls, all other framing to remain the same. 1324 Liberty Lake Rd, Suite 224 • Liberty Lake, WA 99019 phone: [509] 891-0056 • fax: [509] 891-0059 puiye R Rl�k. �. X3811 �• Spo�Qn� Cont-,pVcive tar �. �. �/q • p9ol9 yy-7't 5w 9 8,7/ - 00501 WHEN INTERIOR ALTERATKINS. AEPMIRS OR A90MONS REOUIRING A PERMIT OCCUR, OA VAa ONE OR MORE SLEEPING ROOMS ARE ADDED OR CRUM 0 ENSTING DWELLINGS. THE DWELLNG tNMT SNALL K PRWADED, WITH SMOKE ALARMS LOCATED AS REQUIRED FOR NEW DWELLINGS. WSEC TABLE 6-2 PRESCRIPTIVE REQUIREMENTS-,' FOR GROUP R OCCUPANCY CLIMATE ZONE 2 * Reference Case 0. Nominal R -values are for wood frame assemblies only or assemblies built in accordance with Section 601.1. 1. Minimum requirements for each option listed. For example, if a proposed design has a glazing ratio to the conditioned floor area of 13%, it shall comply with all of the requirements of the 15% glazing option (or higher). Proposed designs which cannot meet the specific requirements of a listed option above may calculate compliance by Chapters 4 or 5 of this Code. 2. Requirement applies to all ceilings except single rafter or joist vaulted ceilings. 3. Requirement applicable only to single rafter or joist vaulted ceilings. 4. Below grade walls shall be insulated either on the exterior to a minimum level of R-10, or on the interior to the same level as walls above grade. Exterior insulation installed on below grade walls shall be a water resistant material, manufactured for its intended use, and installed according to the manufacturer's specifications. See Section 602.2. 5. Floors over crawl spaces or exposed to ambient air conditions. 6. Required slab perimeter insulation shall be a water resistant material, manufactured for its intended use, and installed according to manufacturer's specifications. See Section 602.4. 7. Int. denotes standard framing 16 inches on center with headers insulated with a minimum of R-5 insulation. COOPERATIVE EXTENSION WSEC Builder's Field Guide 5th Edition WASHINGTON STATE UNIVERSITY 1-7 QENERGY PROGRAM Glazing Glazin U -Factor 9 Doors ,2 Wallint Wall? Wall? , Slab 6 Option Area U- Ceiling2 Vaulted Ceiling Above Below Below ext Below Floors on Vertical Overhead „ % of floor Factor Grade Grade Grade Grade I. 10% 0.40 0.58 0.20 R-38 R-30 R-21 R-21 R-12 R-30 R-10 int II. 15% 0.40 0.58 0.20 R-38 R-30 R-19+ R-21 R-12 R-30 R-10 R-56 III. 17% 0.37 0.58 0.20 R-38 R-30 R-19+ R-21 R-12 R-30 R-10 R-56 IV. 25% 0.35 0.58 0.20 R-38/ R-30/ R-21 R-15 R-12 R-30/ R-10/ Group R-1 U=0.031 U=0.034 int' / U=0.029 F=0.54 Occupancy U=0.054 Only V. Unlimited 0.35 0.58 0.20 R-38 R-30 R-21 R-21 R-12 R-30 R-10 Group R-3 int' Occupancy Only VI. Unlimited 0.32 0.58 0.20 R-38 / R-30 / R-21 R-15 R-12 R-30 / R-10 / Group R-1 U=0.031 U=0.034 int' / U=0.029 F=0.54 Occupancy U=0.054 Only * Reference Case 0. Nominal R -values are for wood frame assemblies only or assemblies built in accordance with Section 601.1. 1. Minimum requirements for each option listed. For example, if a proposed design has a glazing ratio to the conditioned floor area of 13%, it shall comply with all of the requirements of the 15% glazing option (or higher). Proposed designs which cannot meet the specific requirements of a listed option above may calculate compliance by Chapters 4 or 5 of this Code. 2. Requirement applies to all ceilings except single rafter or joist vaulted ceilings. 3. Requirement applicable only to single rafter or joist vaulted ceilings. 4. Below grade walls shall be insulated either on the exterior to a minimum level of R-10, or on the interior to the same level as walls above grade. Exterior insulation installed on below grade walls shall be a water resistant material, manufactured for its intended use, and installed according to the manufacturer's specifications. See Section 602.2. 5. Floors over crawl spaces or exposed to ambient air conditions. 6. Required slab perimeter insulation shall be a water resistant material, manufactured for its intended use, and installed according to manufacturer's specifications. See Section 602.4. 7. Int. denotes standard framing 16 inches on center with headers insulated with a minimum of R-5 insulation. COOPERATIVE EXTENSION WSEC Builder's Field Guide 5th Edition WASHINGTON STATE UNIVERSITY 1-7 QENERGY PROGRAM FIGURE 1 CONSTRUCTION DETAILS FOR THE APA NARROW WALL BRACING METHOD WITHOUT HOLD-DOWNS OVER CONCRETE OR MASONRY BLOCK FOUNDATION Outside Elevation Max. height 10' Extent of header (Two braced -wall segments) Extent of header (One braced wall segment) 9 A 2' to 18' (finished width Fasten sheathing to header with Top to 8d common nails in 3" grid continui 's pattern as shown and 3" o.c. in required pe all framing (studs and sills) typ. R602.3.2 x-1000 Ib header -to -jack -stud strap —� on both sides of opening (Install on backside as shown on Side Elevation, Ref. No. LSTA24) Min. (2) 2x4 typ. Braced wall If panel splice is needed it shall segment pey occur within 24" of mid -height. R602.10� Blocking is not required. Ll Min. width based on 6:1 No. of height -to -width ratio: For jack studs example: 16" min. for 8' height R50per toble 2) Min. 2"x2"x3/16" plate washer Anchor bolt per R403.1.6 Typ. Foundation per code Side Elevation Sheathing filler if needed 16d sinker nails in 2 rows @ 3" o.c. 1000 Ib header - to -jack -stud strap on both sides of opening (Ref. No. LSTA24) 3/8" min. thickness wood structural panel sheathing Not to scale CEILING: '/2" GWB if perpendicular to rafters or trusses 24" o.c. and no water based texture used otherwise 5/8" GWB. LANDING required on both sides of exit doors with min. size of 3 ft. measured in direction of travel by 3 ft. or width of door if greater, and not lower than 1 '/2 in. below threshold. Landing required at other exterior doors is a minimum size of 3 ft travel distance by width of door, and not lower than 7 3/4 in. below threshold provided the door does not swing over the landing. EXHAUST FANS 100 CFM kitchen 50 CFM bathrooms & laundry Vc4Jta-3 no E C ON N P OTD OPENINGS BETWEEN DWELLING AND PRIVATE GARAGE SHALL HAVE: 1 MATERIALS APPROVED FOR ONE HOUR FIRE RESISTIVE CONSTRUCTION ON THE GARAGE SIDE: O 5/8" TYPE "X" GYP BOARD (HABITABLE SPACE ABOVE) OR ❑ 1/2" GYP BOARD (RESIDENCE/ ATTIC, FLOOR/CEILING) 2 OPENINGS BETWEEN GARAGE AND RESIDENCE SHALL BE E�UIPPED WITH SOLID WOOD DOOR, SOLID OR HONEYCOMB CORE STEEL DOORS NOT LESS THAN 13/8'. OR 20 MINUTE FIRE RATED DOORS. PROVIDE DIAGRAMS AND ENGINEERING LAYOUTS FOR ROOF TRUSSES, BEAMS AND FLOOR SYS -i EMS PRIOR TO FRAMING INSPECTIONS SMOKE ALARMS SHALL BE INTERCON- NECTED AND HARD WIRED IN SUCH A MANNER THAT THE ACTIVATION OF ONE ALARM WILL ACTIVATE ALL ALARMS. (BEDROOMS, AREAS APPROACHING BEDROOMS, VAULTED CEILING WITH RISE OF 24" & ON EACH FLOOR) EMERGENCY EGRESS REOUIREMENTS FROM SLEEPN O ROOMS 1) NET CLEAR OPENING: 5.7 SQUARE FEET GRADE FLOOR OPENING'.MAX 44") 5.0 SQUARE FEET 2) NET CLEAR OPENING HEIGHT 24 INCHES 3) NET CLEAR OPENING WIDTH 2OINCHES 4) MAX FINISHED SILL HEIGHT 44" ABOVE FLOOR 5 i EMERGE NCY ESCAPE & RESCUE OPENING SHALL BE Oil RATIONAL FROM THE INSIDE OF THE ROOM WITHOUT THE USE Of KEYS OR TOOLS CITY COPY THIS BUILDING SUBJECT TO FIELD INSPECTION CORRECTIONS .X� EVIE1t}d 1WI C?I, „' OM LANCE IASION