1992, 02-28 Permit App: 92001149 Residence -
SPOKANE COUNTY DEPARTMENT OFZUILLllNGS
W. 1303 BROADWAY AVENUE
SPOKANE,WASHINGTON 99260
(509)456-3675
I certify that I have examined this permit/application,state that the information contained in it and submitted by me or my agent to compile said permit/application is true
and correct, and authorize Spokane County to proceed with processing. In addition, I have read and understand the INSPECTION REQUIREMENTS/NOTICE
provisions included herein and agree to comply with same.All provisions of laws and ordinances governing this type of work will be complied with whether specified
herein or not.I understand that the issuance of this permit/application and any subsequent inspection approvals or Certificates of Occupancy shall not be construed to
give authority to violate or cancel the provisions of any state or local law regulating construction,or as a warranty of conformance with the provisions of any state or local
laws regulating construction.
SIGNATURE OF APPLICATION
OWNER OR AGENT DATE
PROJECT NUMBER= 9200-'049 APPLICATION DATE=" 02/28/92 PAGE= 01
**•** THIS IS NOT A PERMIT ******
PENALTIES; WILL.. BE ASSESSED FOR COMMENCING WORK WITHOUT A PERMIT
SITE STREET= 19024 E RIVERSIDE AVE- • PARCEL.4:= 17553-1807
ADDRESS:::: GREENACRES WA 99016
PERMIT USE= RESIDENCE -- ELECTRIC WAL.I... MOUNTS
PL..AT4= 001 092 PLAT NAME= GUTHRIE ' S VALLEY VIEW 05TH ADD
BL..00K.::- 8 LOT= 7 ZONE= UR--3 .5 DIST (:
AREA- F:/A=: F WIDTH= 80 DEPTH=- 120 RiW- 50
w OF BL.DGS:-: 4 DWELLINGS= 1 WATER DIST = CONSOLIDATED TRRG ti
OWNER= NATIONAL.. LENDER SERVICES INC PHONE= 509 534 5314
STREET= 5 502 E:: 3RD AVE::
ADDRESS= SPOKANE WA 99212
CONTACT NAME= KEN MICKELSON PHONE Nl.)MT:tER- 509 534 5314
BUILDING SETBACKS : FRONT-- 30 LEFT=1 7.W. RIGHT= :90 / 3R1AR::: 66
x•x• ' •*u***•x•* •** ••x**x*** :******* REVIEW INF'ORMA'TI(:lN ***•x**** •*it•it•*9(iir:•x• •*•x******
DEPARTMENT REVIEW COMMENTS ..... APPROVAL COMMENT
_
BUILDING "LAN REVIEW REQUIRED 1 "eQ _ 5..... `..1 .. .
BUILDING SETBACK REVIEW REQUIRED
02' ( '/° ArY f
BUILDING ENERGY PLAN REVIEW REQUIRED. .0 MP.U. .
ENGINEER APPROACH/FLOOD PLAIN/DRAINAGE: /47° 3 .... • ',140.-4&.!dam
HEALTHDIST NEW OR ADDITIONAL. WASTE WATER 1-1(.41› a-- 9-yo-47-
W4 m#2-
(1
•h:•}i*�t*#�i*7r*is*•k•*k***• : n;at•*iii�t 3i* :**•1i B 1.1 I L..D i N G F'E:.R M I 1 ,i,4N p: :�:k N•1+::+4 ,f R 7C A i+:ii•i+ .kk A
CONTRACTOR= NAT:i.ONAI... LENDER SERVICES INC PHONE= 509 534 5314
STREET= 5502 E 3RD AVE
ADDRESS= SPOKANE WA 9921 2
NEE:-: X REMODEL= ADDITION= - CHANGE OF USE=
DWEL.i_. UNITS= 1 OCCU 'a LD-: BLDG NGT:- STORIES=
BLDG W x D ::- x SQ FT= 960 SPRINKLER=R= N
REQ PARKING= :M•HANDICAF'-= CRITICAL MAT= N
-re :x••x*•;t*:>i•**•x-rt••»:•ae•ft•x* •sex*•;t '* : •* •r• PL..i.JMRING PERMIT •*' *x•x*******••r~;*•x*•**••******•*****•
CONTRACTOR= UNKNOWN PHONE:
. STREET:::: UNKNOWN
ADDRESS= UNKNOWN WA UNKNOWN
PROCESSED BY : WE NDE:L.., GLORIA
PRINTED D .Y. : WENDEL.., GLORIA
•ii*if•N•*it••ii•§k**ib•N••Hi*')f•h:3t•ri••»•#*•k ai•Mr yr•k i{*3e*it•* THANK YI.l E,( 'r.'$1•:ri•N:is•1t•7l••1C•){•*:a'!t•?{3l•')k'/F•!{'r:•h•r:*'lk*')t••)t•Jk'R•'N.•3¢ir'n'tt•$:
f ♦ 4,
I y
NOTICE
It is the responsibility of the permittee, not Spokane County, to see to it that the use described on the front of this permit
complies with applicable codes and requirements and that required inspections are requested. Failure to request required
inspections and obtain the necessary approvals prior to progressing beyond the point where inspections are required may
necessitate removal of certain parts of the construction at the owner's/permittee's expense. At a minimum, the following
inspections ARE REQUIRED by County Code:
1. FOOTING—when forms and reinforcement are in place and prior to placement of concrete.
NOTE:This inspection includes review of the structure's setbacks from property lines.Minimum setbacks are
established by County zoning regulations.Typically,side and rear yard setbacks are measured from property
lines, while setbacks for yards abutting streets are measured from the property line or the center line of the
roadway right-of-way,whichever provides the greater setback from the center line of the roadway right-of-way.
Curb lines and fence lines are not necessarily indicative of property lines.In some residential areas,the County
can own as much as 20 feet of right-of-way between your property and the actual improved street/curb.The
responsibility to comply with applicable setback provisions lies solely with the permittee—neither Spokane
County nor its authorized representatives assume any responsibility for the verification or location of your
property lines.Please verify their location prior to locating your structure.Failure to properly locate the structure
may require its relocation at the owner's/permittee's expense.
2. FOUNDATION—when forms and reinforcement are in place and prior to placement of concrete.(Blocking for a
manufactured home is required to be inspected prior to the installation of skirting.)
3. FRAMING—after all framing, bracing and blocking is in place,and prior to concealing.
4. INSULATION— prior to the installation of drywall.
5. PLUMBING—after rough-in, before covering,and final.
6. MECHANICAL—rough-in of piping, before covering, metal chimneys before concealment,and final.
7. FINAL—when complete and prior to occupancy and/or use. Please provide 24 hours notice.
NOTE:In addition to inspection of the structure,this inspection includes review of site improvements(typically
depicted on the approved site plan)required by ordinance or as a condition of approval of this permit.Items such
as the installation of fire hydrants,fire department access,on-site drainage("208 swales"),road improvements,
parking,and landscaping are common requirements of a permit/site plan which must be completed prior to final
approval of a building or issurance of a Certificate of Occupancy.
In addition to the above any plumbing or mechanical systems or materials which would be concealed by framing, drywall,
concrete, etc., must be inspected prior to cover. Check with the department for "special inspections" in conjunction with
commercial projects.
CELL 456-3675 FOR INSPECTIONS.
TO INSURE PROMPT SERVICE, PLEASE GIVE 24 HOUR NOTICE.
YOUR INSPECTOR IS
UNDER' CERTAIN CIRCUMSTANCES, PARTS OF YOUR PROJECT MAY REQUIRE INSPECTIONS FROM OTHER
AGENCIES:
• road cuts for utilities or drives,State or County Engineer's Office
456-3600
• on-site waste disposal system, Environmental Health District
456-6040
• construction in a flood plain, County Engineer's Office
456-3600
• electrical wiring, State Department of Labor and Industries
456-2792
• sewer connection, County or City Utilities Department
456-3604
EXPIRATION
Unless otherwise noted, this permit will be considered null and void by limitation of the work authorized by the permit is not
commenced or is stopped for a period of 180 days, unless a written request for an extension of the permit is received and
approved by the Building Official prior to expiration.At a minimum an inspection should be requested at least once every 180
days to assure the validity of the permit.A permit may be renewed within one year of the date of expiration for one-half the
original fee,subject to certain limitations—please call us if you have any questions.
MISTAKES?
If you think we've made an error in processing this permit or in conducting inspections pertaining to it, or find erroneous
information in the permit,please bring it to our attention immediately by filing a written request for correction within 10 working
days of discovery.All such requests should be directed to the Department of Buildings at the address found on the face of this
permit.
, ��1�'� �:� m:��/N b� /� nu'���� 141J4 FC.,
~ ` ' ~
. "
SP
�/
r��0 ... vv/ /m}/qO[�U� ' ' ~,"«wwm^ � y -. •
�A THIS APPROVED PLN.. IP ~' "n � v««� /ou ^ �
- ��-
4.-70' AT (509) = �v«0 �yO09U T�UVSYT�cI�XL/4qlH/0?&LoFF°( -TBENCH W1D111 -~�
/ /�7- 7 BLOCK � E ---'
�- �/ / LJL_ L/\~ [\ `�� '~---�
GUT LN / / [- `� ' ' - - -~� •
�� �� ' / / / \-� L- `J ��1/� �- L- / ��~L�~
� '-- -'' ---- ' ----'- c-- 1'' -- u«/c' c(--E-1?
/ __-----8D'- ----- _�� '
e----__--________________ -------�
18w`• ----------------- --------__________________ /
IN -
U7/1 / [ y /v
���[ ENT
' �0 - - - - - - - - - - - L'
. /
/ ` * � /
/ , '~ / ���
/ / / v,
'..
.
|| '/
~// . cr ~'-1~ * +�«
.
�~<�/. I��/
//./ '•
~' ,. / ____ y / ' // 66
'/./// ~ ' p �� - �~ ' . ^ -
/
./
/ / � � �
.
' | \ 7
i | / ' ' '
� ���
� / '
| / \
layw�/1* J000 GA -
/ � pK0�L 3rf7tCf
CQ�J /
J2O~
/...
al
' *' 1,14STEA ~---- / ' � |
. 8[0RO(M /��yI�0 / / ``
�-� /
��LhIm / N.
/ /
�---_�__--^_�_-- . / .
1""'
- '
/ -7 --T^I.om/'
� .
, �
/ F--�-1~r" / � ' |
| /
J �—I—._�-1 |- |
.. ._D._R...r._.v_.: .'--- 1
�� ` /
�
5 � /IlN �84DF 3
0-"-
I
LA
i- �----'------ > |
------ '------ � | «»w' / 7
-�_�_.'
r,-_,#_._
, .____
------- ----- --- ------
. (50. .._______________ ____
.
~ .
'
•
.
.....___.
_--_ °~~�~~�~~~~.
Spokane County
DEPARTMENT OF BUILDING & SAFETY
West 1303 Broadway Avenue Spokane, WA 99260 (509) 456-3675
INFORMATION WORKSHEET
PARCEL NUMBER: /15- fe07
STREET ADDRESS: / l v t 1\-) c)'
`- U v
CITY/STATE/ZIP: J 1)CO , lH /D
SUBDIVISION: u V' U l'Q-c
BLOCK: S LOT: ZONE: DISTRICT:
LOT AREA: F/A: WIDTH: SU DEPTH: ( --C) R/W:
# OF BUILDINGS: / # OF DWELLINGS: WATER DISTRICT:
OWNER: Al c( z^c • PHONE: - 5.3y- 63/y
MAILING ADDRESS: -C-56, 2 31, c(
CITY/STATE/ZIP: S V' a Z ( �-
CONTACT: PHONE: -S3 S/- (5.3/
SETBACKS: - FRONT: B7) LEFT: n C RIGHT: e e REAR:
PERMIT USE:
****************************************************************************
BUILDING INFORMATION
CONTRACTOR LICENSE NUMBER:
CONTRACTOR: mJ44_,t1z.v„¢2A ��-,�L .�C y� 1 c� eHONE: - y - y
MAILING ADDRESS:
ARCHITECT/ENGINEER: PHONE: - -
MAILING ADDRESS:
NEW: REMODEL: ADDITION: CHANGE OF USE:
DWELL UNITS: OCCUPANT LOAD: BUILDING HGT: STORIES:
BUILDING DIMENSIONS: X (WIDTH X DEPTH) SQ. FT. :
REQUIRED PARKING: # HANDICAP: SPRINKLERED: CRITICAL MATERIAL:
Please provide the following information for i''nergy Code compliance:
Space heating type (check one)
Forced air electric Electric baseboard or wall mount Propane
Forced air gas Heat pump Other:
Flat ceilings R .19)e Doors Aoki"#
Vaulted ceilings R is Windows
Above grade walls R- Glazing area /I
Below grade walls R — Total floor area
Floor R of heated space (ik C
Slab on grade R--- Furnace efficiency rating -----
Please
—Please indicate on your plans: The location of the radon vent, and the location of the vent fan area.
Square footage
Main floor: C i fr`
Second floor:
Basement- Finished:
Unfinished:
Garage:
Carport:
Decks:
Additional Areas:
i +
WATTSUN 5 .2 1991 WA STATE ENERGY CODE COMPLIANCE REPORT 02/25/92
FILE : C : \WATTDATA\NATLEND4 .WS HOUSE ID: NATLEND4
Site : 1902/ E , Riverside Analyst : TAS
Spokane County , WA Jurisdiction : Spokane County
( ) - Utility : WWP
Homeowner : House Type : Single Family/Duplex
Floor Area : 960 ft2
( )
Builder : National Lender Services Weather Data : Spokane , WA
Climate Zone : L
( ) -
The PROPOSED design *COMPLIES* with 1991 WA State Energy Code .
REFERENCE PROPOSED
COMPONENT PERFORMANCE 160 155 Btu/hr-F
ENERGY BUDGET 3 .61 3 .75 kWh/ft2-yr
REFERENCE DESIGN
Reference
Component Value X Area = UA
Floor U-0 .029 960 27 .8
Glazing @15% U-0 .400 144 .0 57 .6
Doors U-0 .200
42 .0 8 .4
AG Wall U-0 .044 830 36 .5
Ceiling , Attic U-0 .031 960 29 .8
Infiltration ACH-0 .350 7680ft3( 46 .5 )
Reference UA 160
PROPOSED DESIGN COMPONENTS
Component Description Value X Area = UA
Floor **R-30 vented joist 24"oc U-0 .028 960 26 .9
Glazing @10% **Vinyl frame dbl . glz .w/AR U-0 .380 65 .0 24 .7
**Vinyl dbl .glz . patio w/AR U-0 .480 34 .0 16 .3
Doors Metal 1-3/4" urethane flush U-0 . 140 21 .0 2 .9
**Metal 1-3/4 " urethane raised panel U-0 . 170 21 .0 3 .6
AG Wall R19 ADV T1-11 U-0 .058 875 50 .8
Ceiling R38 blown Attic STD baffled U-0 .031 960 29 .8
Items in parentheses not included in COMPONENT PERFORMANCE totals .
** Denotes non-standard values - check calculation of thermal value .
---= Page 1
WATTSUN 5 .2 1991 WA STATE ENERGY CODE COMPLIANCE REPORT 02/25/92
FILE: C :\WATTDATA\NATLEND4 .WS HOUSE ID: NATLEND4
Infiltration Standard Air Sealing ACH-0 .350 7680ft3 ( 46 .5 )
Proposed UA 155
Struc Mass Light Frame , Sheetrock walls M- 3 .000 960 2880
HEATING/COOLING/VENTILATING SYSTEMS
PROPOSED
Heating System Type : Electric : Zoned
System Efficiency : 100 %
Modified Efficiency : 100 %
Design ACH : 0 .60
Heating Load( at 66F dt ) : 15486 Btu/hr
System Size : 4 .5 kW
Maximum Size @150% : 6 .8 kW
Average Annual Heat : 4680 kWh
Annual Cost : $ 257
Ventilation System: Integrated Spot
& Whole House
Cooling Load( at 12F dt ) : 14646 Btu/hr
Recommended Size @125% : 1 .7 tons
Solar Access : Partially Shaded
GLAZING ORIENTATION
PROPOSED PROPOSED
South : ft2 North : ft2
Southeast : Northwest :
East : 51 .0 West : 48 .0
Northeast : Southwest :
Economic and energy consumption estimates are designed for comparative
purposes only . Actual cost for heating will vary depending on weather
conditions , occupant lifestyle and other factors .
WATTSUN 5 .2 COMPONENT CHECKLIST 02/2.5/92
FILE : C : \WATTDATA\NATLEND4 .W5 HOUSE ID : NATLEND4
Name : Floor Area : 960 ft2
Address: 19023 E , Riverside Heating Type : Electric: Zoned
Reference : 1991 WA State Energy Code
FRAMING INSPECTION
Approved plans :
Are available onsite
Air leakage :
Soleplate is caulked or glued to subfloor . Rim joists between
stories are caulked/sealed .
All holes in building envelope ( i .e . exterior ceilings , walls , and
floors ) are caulked/sealed , including all electrical , plumbing ,
and HVAC penetrations .
Outlets , switch boxes and recessed fixtures on exterior walls are
caulked/sealed with approved sealant , or have foam face gaskets
installed .
Any recessed lights are IC rated , air tight , and sealed to the
ceiling sheetrock .
Wall framing:
Net wall area : 875 ft2
Advanced framing with studs spaced 24 " o .c . , R-10 insulated
headers and no isolated cavities which cannot be insulated .
Structural panels:
All structural sheathing is stamped "Exposure I " or "Exterior " .
Windows :
( Vinyl frame dbl . glz .w/AR 65 .0 ft2 )
( Vinyl dbl .glz . patio w/AR 34 .0 ft2 )
Windows are installed as shown on the approved plans . The rough
opening around windows and doors is caulked/sealed .
Exhaust fans , spot ventilation:
Bathroom fans are 50 CFM , kitchen fans are 100 CFM . Fan ducting
has minimal bends and terminates outside of the building .
The whole house exhaust fan is between 50 and 75 CFM .
The whole house fan is rated at 1 .5 sones or less ( unless remotely
located ) .
INSULATION INSPECTION
Wall insulation :
CR19 ADV T1-11 875 .0 ft2 )
Insulation fills all exterior wall cavities . It is not compressed
and is cut to fit around wires , pipes , and outlet boxes . Recessed
= Page 1
WATTSUN 5 .2 COMPONENT CHECKLIST 02/25/92
FILE: C : \WATTDATA\NATLEND4 .WS HOUSE ID : NATLEND4
fixtures in exterior walls have at least R-5 insulation behind
them .
Vapor retarder : 1 .0 perm or less vapor retarder ( e .g . poly , kraft
paper , perm rated paint ) is installed on the warm side of
insulation in floors , ceilings and walls .
Recessed lights :
Any recessed light fixtures in the thermal envelope are certified
under ASTM E-283 and labeled showing compliance , or are sealed
around the exterior to be air tight .
FINAL INSPECTION
Crawl space moisture barrier :
A six mil black polyethelene ground cover is installed on
crawlspace floor .
Floor Insulation:
( R-30 vented ,joist 24"oc 960 .0 ft2 )
Insulation is supported in a permanent manner without compression .
Crawlspace ventilation:
At least 3 .2 Ft2 of net free ventilation is provided
in the crawlspace .
Pipe insulation:
All water pipes in unheated spaces are insulated to R-3 .
Hot water :
Electric water heater labeled as meeting ASHRAE Standard 90A-1980
or 1987 NAECA . Tank has R-10 non-compressible pad underneath if
located over slab or in unconditioned space . Shower heads allow a
maximum flow rate of 3 .0 gallons per minute .
Doors:
( Metal 1-3/4 " urethane flush 21 .0 ft2 )
( Metal 1-3/4 " urethane raised panel 21 .0 ft2 )
Weatherstripping , threshhold , and doorsweep are properly adjusted
and seal well .
Ceiling:
( R38 blown Attic STD baffled 960 .0 ft2 )
Insulation is installed to the manufacturer 's recommended density
and coverage . Attic access doors are insulated and
weatherstripped .
Heating system:
Electric : Zoned
The heating system does not exceed: 6 .8 kW .
Page 2 --
WaTTSUN 5 .2 COMPONENT CHECKLIST 02/25/92
FILE: C: \WATTDATA\NATLEND4 .WS HOUSE ID: NATLEND4
-------------
Ventilation:
The ventilation system has been checked for proper operation . If
designed for intermittent operation , the system is controlled
automatically by a time-of-day timer set to run for a minumum of
eight hours per day . If designed for continuous operation , the
system is directly wired to a dedicated circuit in the electrical
panel .
Make-up air :
Ports or registers supplying outside air in the quantity of 10 CFM
are located in each bedroom and the main living area .
Radon monitor :
Radon monitor supplied to residents .
Exhaust duct insulation :
All exhaust ducts in unheated spaces are insulated to R4 .
Page 3 ---
p SPOKANE COUNTY DEPARTMENT OF BUILDINGS
(r
o ,ATE / 167-2i/ 167-2i �
ADDRESS 5 � �1 ..&J S' e RESIDENTIAL ENERGY CODE INSPECTION CHECKLIST
o PERMIT 72 -
SUB-SLAB
Li.,. ___ • _ _
_ ._._. _ . ____ ._,___ . _
. r>,
• PERIMETER INSULATION R- /mom_ ..RAVEL BASE o PLASTIC MEMBRANE
0
o APPROVED FOR COVER BY DATE
0
0
=1 N'' t]I=AT-i t�N �& AU L
•
o % , INDOWS &DOORS PER PLANS jW INDOWS&DOORS CAULKED o VAPOR RETARDERS:
o • ADVANCED FRAMING: o-SOLEPLATE CAULKED • WALL pj°5fr' C.
CEILING //
o WALLS h UMBING//EL.ECTRICAL4111 . CEILINGS a VENT BAFFLES
PENETRATIONS CAULKED .
• WALL INSULATION: R-/9 K o S
• VAULTED CEILING: R- `3 O I4lD
o aL,EXFAUST FANS/DUCTS b-CF-IAWLSPACE VENTILATION
INSTALLATION INSTALLED
o TECHNIQUES SON FAN CIRCUIT
0
0
0 o APPROVED FOR COVER BY ,,'� ,__ DATE
o
• o * p C
o MECHANICAL SYSTEMS o WEATHERSTRIPPING o PLUMBING
0
• TH EXHAUST oeI6ORS &WINDOWS ATER HEATER PAD
0
• ITCHEN EXHAUSTTTIC &CRAWL ACCESSES ROWER FLOW
• - TOMATIC WHOLE HOUSE 6-6" TCH &OUTLET COVER
EXHAUST PLATES o FIREPLACE DOORS
AKE-UP AIR INTAKESdrr
ev;4# i✓ o FLUE DAMPER
. :• - -••a-• o INSULATION o COMBUSTION AIR
o EQUIPMENT INSTRUCTIONS o FLOOR R- 3 (2
•
Ili 4-- ATING FUEL&SY,STE TYPE: o ATTIC R- 5 ✓• o WLSPACE GROUND COVER.
$ 49 T e d e - ` ' '•• . D TT T RAWLSPACE VENTILATION
M -r .6-457(T1 INSTALLATION
0 RATjpN M0N 1op TECHNIQUES J
:rc� — / 1