1992, 04-28 Permit App: 92002887 ResidenceSPOKANE COUNTY DDP'ARtMENT OF BUILDINGS
W. 1303 BROADWAY AVENUE
SPOKANE, WASHINGTON 99260
(509) 456-3675
I certify that I have examined this permit/application, state that the information contained in it and submitted by me or my agent to compile said permit/application is true
and correct, and authorize Spokane County to proceed with processing. In addition, I have read and understand the INSPECTION REQUIREMENTS/NOTICE
provisions included herein and agree to comply with same. All provisions of laws and ordinances governing this type of work will be complied with whether specified
herein or not. I understand that the issuance of this permit/application and any subsequent inspection approvals or Certificates of Occupancy shall not be construed to
give authority to violate or cancel the provisions of any state or local law regulating construction, or as a warranty of conformance with the provisions of any state or local
laws regulating construction.
SIGNATURE OF APPLICATION
OWNER OR AGENT DATE
PROJECT NUMBER- 92002807
DATE- 04/28/92
***:: h: -:u' THIS I NO.T, to PERMIT ** *•?i'y1.*
PENALTIES WILL BE ASSESSED F (; i R COMMENCING WORK WITHOUT A PERMIT
L..(.1:: STREET-
ADDRESS-
PERMI
T'E.EE'T-:tiD(>I=•(
PLAT
BLOCK -
AREA..
OF BLDGS-
OWNER-
STREET-
t`f}:'j:Rr SS-
L. E:NisE:,R NAME-
STREET-
ADDRESS-
38
[KANE WA 99206
RESIDENCE
00526
H.
.... NATURAL 1,iE:AL.. (.,r:AA
MIDI
PLAT NAME-
I...i.iT-
i_)i4F:L..L.. I Ni..,,.:,::::
(:; is E: M `T' :I: I''J (::
42212 E EIOt
P(::f!f ANE WA `•
WASHINGTON
I ., I::1 :. BOX i;
SPOK ANC WA
TRUST :i f;FiNK
99210
CONTACT NAME- FRANK COBB
BUILDING F I::: •T B fa (::: K ;:';' : FRONT- 30
I..E:.1 t::.. :I:..
,••, .N..._. 33541-9044
I..L:1ME. :i•II•'I ADD
ZONE- Ui:'."-:'.,r
! 7 T I;
W{)±I:r? DEPTH- 125
;.
+:-
R / iii ::
WATER DIST - MODEL
PHONE- 509 924 '9406
PHONE NUMBER- `'j(ji 353 5629
RIGHT- i4 REAR- 52
k' "i :*+r :N:' * P:• 'jt• :)+r /i: •H• * Qi• * T: iui :) i M• :Jt' •M 7$ 7,: 1i• iu• * j1. * 'K :!t• 'jt• I:; 1 * 'i Si i 'n H i i i ii s 'u i 1i
I::. 'u .I. L': G•. ±''� ." ?. � "-� 1"I f^± I. l! ±' . .. is '.: 'N::R"N: c+; :: -M.• :�.' :: },; :n. i s •. i• 9: •!F '.: i::: 3: '.: '1•'
BUILDING
BUILDING
BUILDING
REVIEW COMMENTS
PLAN REVIEW REQUIRED
SETBACK RE::v:F E•:IJ REQUIRED
ENERGY
f't...r:;i"J REVIEW REQUIRED
E:.D
ENGINEER APPROACH/FLOOD PLAIN/DRAINAGE
APPROVAL COMMENTS
9. 9:. i ?l.:.i. * :y..),..),. :J!' 'li' Nt• t,; g,. y,, •;+: •!!•'jk •14 l+r 'Fi 1{. jr .ji. .jk')7 ?4 9+: ii' 1; i t.i . it .. `v ! ; -' •:' "� � i
)... (' .. ::.. .fit ..
CONTRACTOR-
ADDRE-
'J 4::: i:.i ::::
DWELL. UNITSREO PARKINGz
GREMY INC
122i2 E. SIOUX CIR
SPOKA\IE WA 99
DESCRIPTION
i`t:::'E:.i'''tE::14 T' l'
BASEMENT 1.!
RESIDENCE
REMODEL
i;:ii::i":i.. P : t. i:):'::
i 2S `,cif FT=
•.+'Iii". t`f f' =
(:' E-'t:J1.1E'
TYPE
•
VO
1; 1,
V ('J
VO
i
SO FT
40
648
.F (.)0;.{
.. A. s:..... , s -
.;t..j,.:p 34..jp, .)(. .;,: 9k ..:X..)!' .i )t' 9!' :)t' t++r ji• ;n :/i• ?7 :J+: ii' i. •ji::J,i )+i 1: 9'.
PHONE- 509 924 9406
ADDITION- CHANGE i":#%" USE
BLDG i•'iir ; - 24 •i..tiR F1,.
CRITICAL. MAT -
ITEM DESCRIPTION QUANTITY
RESIDENTIAL VALUATION
STATE SURCHARGE
COUNTY EURCHARGE
+i :!+i ;% i*t 'P: ')t: iu: 9i.:!,; i,; :)f..ji. qi: L} .j+i ••: 'ji. 1.... i+r ai- :R' 9+i :N::ur ii• Vii; d!• )e ;i+; ..
CONTRACTOR- 4:; HEATING
ADDRESS- 'i.::i1<::ANE WA
.I...(.1::. i,; (1 `> i:r is ' "i• .1: ON
MECHA-IICAL PERMIT
AIR CONT? INC
AVE
44
�.. �.GAS WIG 000>BTU
GAS LOG
t. .
r°ti .1.if T .i• oN
J.. i1,.i
+`•i , l
FEE AMOUNT
621 50
4
ji..ji• i+i. •j{..j,i •jc :P: in' . •jf- at. ;'.. 9i' 3 .)i 3. 3i' 'R' iri- .....;i....,:. if j;.
PHONE- 509 -84 1407
FEE AMOUNT
{'
NOTICE
It is the responsibility of the permittee, not Spokane County, to see to it that the use described on the front of this permit
complies with applicable codes and requirements and that required inspections are requested. Failure to request required
inspections and obtain the necessary approvals prior to progressing beyond the point where inspections are required may
necessitate removal of certain parts of the construction at the owner's/permittee's expense. At a minimum, the following
inspections ARE REOUIRED by County Code:
1. FOOTING — when forms and reinforcement are in place and prior to placement of concrete.
NOTE: This inspection includes review of the structure's setbacks from property lines. Minimum setbacks are
established by County zoning regulations. Typically, side and rear yard setbacks are measured from property
lines, while setbacks for yards abutting streets are measured from the property line or the center line of the
roadway right-of-way, whichever provides the greater setback from the center line of the roadway right-of-way.
Curb lines and fence lines are not necessarily indicative of property lines. in some residential areas, the County
can own as much as 20 feet of right-of-way between your property and the actual improved street/curb. The
responsibility to comply with applicable setback provisions lies solely with the permittee — neither Spokane
County nor its authorized representatives assume any responsibility for the verification or location of your
property lines. Please verify their location prior to locating your structure. Failure to properly locate the structure
may require its relocation at the owner's/permittee's expense.
2. FOUNDATION — when forms and reinforcement are in place and prior to placement of concrete. (Blocking for a
manufactured home is required to be inspected prior to the installation of skirting.)
3. FRAMING — after all framing, bracing and blocking is in place, and prior to concealing.
4. INSULATION — prior to the installation of drywall.
5. PLUMBING — after rough -in, before covering, and final.
6. MECHANICAL — rough -in of piping, before covering, metal chimneys before concealment, and final.
7. FINAL — when complete and prior to occupancy and/or use. Please provide 24 hours notice.
NOTE: In addition to inspection of the structure, this inspection includes review of site improvements (typically
depicted on the approved site plan) required by ordinance or as a condition of approval of this permit. Items such
as the installation of fire hydrants, fire department access, on-site drainage ("208 swales"), road improvements,
parking, and landscaping are common requirements of a permit/site plan which must be completed prior to final
approval of a building or issurance of a Certificate of Occupancy.
In addition to the above any plumbing or mechanical systems or materials which would be concealed by framing, drywall,
concrete, etc., must be inspected prior to cover. Check with the department for "special inspections" in conjunction with
commercial projects.
CALL 456-3675 FOR INSPECTIONS.
TO INSURE PROMPT SERVICE, PLEASE GIVE 24 HOUR NOTICE.
YOUR INSPECTOR IS
UNDER CERTAIN CIRCUMSTANCES, PARTS OF YOUR PROJECT MAY REQUIRE INSPECTIONS FROM OTHER
AGENCIES:
• road cuts for utilities or drives, State or County Engineer's Office
456-3600
• on-site waste disposal system, Environmental Health District
456-6040
• construction in a flood plain, County Engineer's Office
456-3600
• electrical wiring, State Department of Labor and Industries
456-2792
• sewer connection, County or City Utilities Department
456-3604
EXPIRATION
Unless otherwise noted, this permit will be considered null and void by limitation of the work authorized by the permit is not
commenced or is stopped for a period of 180 days, unless a written request for an extension of the permit is received and
approved by the Building Official prior to expiration. At a minimum an inspection should be requested at least once every 180
days to assure the validity of the permit. A permit may be renewed within one year of the date of expiration for one-half the
original fee, subject to certain limitations — please call us if you have any questions.
MISTAKES?
If you think we've made an error in processing this permit or in conducting inspections pertaining to it, or find erroneous
information in the permit, please bring it to our attention immediately by filing a written request for correction within 10 working
days of discovery. All such requests should be directed to the Department of Buildings at the address found on the face of this
permit.
SPOKANE COUNTY DEPARTMENT OF BUILDINGS
W. 1303 BROADWAY AVENUE
SPOKANE, WASHINGTON 99260
(509) 456-3675
I certify that I have examined this permit/application, state that the information contained in it and submitted by me or my agent to compile said permit/application is true
and correct, and authorize Spokane County to proceed with processing. In addition, I have read and understand the INSPECTION REQUIREMENTS/NOTICE
provisions included herein and agree to comply with same. All provisions of laws and ordinances governing this type of work will be complied with whether specified
herein or not. I understand that the issuance of this permit/application and any subsequent inspection approvals or Certificates of Occupancy shall not be construed to
give authority to violate or cancel the provisions of any state or local law regulating construction, or as a warranty of conformance with the provisions of any state or local
laws regulating construction.
SIGNATURE OF APPLICATION
OWNER OR AGENT DATE
PROJECT NUMBFR,,, 92002a87
APPLICATION DATE- 04
.. t f ... P E » } » ,.. j.: ;. ' t :,j. ';. ;. •;.. " i' 'Y: -»: i1,::,�'. ,u.:,.:y�.
PAGE-
***************************** }`� 1,,.1,11"i �.:{ .i. S': }..r t" C:. 1't i'l I I '}t '1t :n: N:.?t �)p u: •f`i .P.. C .:.H• •}. }.•1.
CONTRACTOR-
rr-:, ::;11.FPLUMBING HEATING
- PO BOX 3992
ADORES:' , E;,O1ti ..;.}>~11::' WA}!yj.,,'.. `"
ITEM M I:} F:: , ' C R is F.: ;' :1: 1.:1 N
TOILETS
SINKS
j.'1'iOWE: R.1
BATH TUBS
KITCHEN SINKS
DISH WASHERS
GARBAGE DISPOSAL
CLOTHES WASHER
FLOOR DRAINS
PERMIT TYPE
min DING PERMIT
MECHANICAL PRMT
'T•
PLUMBING PERMIT
FEE AMOUNT
00
E i ' l.`i (:;1:: ,:.. ; r.)) B'Y' t } (t r1.1: T F: OV .i f; Fi , /ROBIN'
!'E='];i`d1..1::::} BY: ;(ari:l: it i_.i.,,,,l:l:;H ROBIN
PHONE', 509 A9P6
.r •`i 1::'1:'.P:. i•.111i?:jl`'11.
00
6,06
6.60
AMOUNT PAID
-00
-00
,00
AMOUNT OWING
........................
************:k****************** '(•E•(a.tNi<. Y k:.l t.1 * •»• •»: •.}i..»:• }{ * :q..„; *.»• :}k i;. •}i..;,; .}f..»; ti;, :r, * •++: 3i• ae; tip: id' ^i• ii• * iNr y;. i; ;,u
1.
NOTICE
It is the responsibility of the permittee, not Spokane County, to see to it that the use described on the front of this permit
complies with applicable codes and requirements and that required inspections are requested. Failure to request required
inspections and obtain the necessary approvals prior to progressing beyond the point where inspections are required may
necessitate removal of certain parts of the construction at the owner's/permittee's expense. At a minimum, the following
inspections ARE REQUIRED by County Code:
1. FOOTING — when forms and reinforcement are in place and prior to placement of concrete.
NOTE: This inspection includes review of the structure's setbacks from property lines. Minimum setbacks are
established by County zoning regulations. Typically, side and rear yard setbacks are measured from property
lines, while setbacks for yards abutting streets are measured from the property line or the center line of the
roadway right-of-way, whichever provides the greater setback from the center line of the roadway right-of-way.
Curb lines and fence lines are not necessarily indicative of property lines. In some residential areas, the County
can own as much as 20 feet of right-of-way between your property and the actual improved street/curb. The
responsibility to comply with applicable setback provisions lies solely with the permittee — neither Spokane
County nor its authorized representatives assume any responsibility for the verification or location of your
property lines. Please verify their location prior to locating your structure. Failure to properly locate the structure
may require its relocation at the owner's/permittee's expense.
2. FOUNDATION — when forms and reinforcement are in place and prior to placement of concrete. (Blocking for a
manufactured home is required to be inspected prior to the installation of skirting.)
3. FRAMING — after all framing, bracing and blocking is in place, and prior to concealing.
4. INSULATION — prior to the installation of drywall.
5. PLUMBING — after rough -in, before covering, and final.
6. MECHANICAL — rough -in of piping, before covering, metal chimneys before concealment, and final.
7. FINAL — when complete and prior to occupancy and/or use. Please provide 24 hours notice.
NOTE: In addition to inspection of the structure, this inspection includes review of site improvements (typically
depicted on the approved site plan) required by ordinance or as a condition of approval of this permit. Items such
as the installation of fire hydrants, fire department access, on-site drainage ("208 swales"), road improvements,
parking, and landscaping are common requirements of a permit/site plan which must be completed prior to final
approval of a building or issurance of a Certificate of Occupancy.
In addition to the above any plumbing or mechanical systems or materials which would be concealed by framing, drywall,
concrete, etc., must be inspected prior to cover. Check with the department for "special inspections" in conjunction with
commercial projects.
CALL 456-3675 FOR INSPECTIONS.
TO INSURE PROMPT SERVICE, PLEASE GIVE 24 HOUR NOTICE.
YOUR INSPECTOR IS
UNDER CERTAIN CIRCUMSTANCES, PARTS OF YOUR PROJECT MAY REQUIRE INSPECTIONS FROM OTHER
AGENCIES:
• road cuts for utilities or drives, State or County Engineer's Office
456-3600
• on-site waste disposal system, Environmental Health District
456-6040
• construction in a flood plain, County Engineer's Office
456-3600
• electrical wiring, State Department of Labor and Industries
456-2792
• sewer connection, County or City Utilities Department
456-3604
EXPIRATION
Unless otherwise noted, this permit will be considered null and void by limitation of the work authorized by the permit is not
commenced or is stopped for a period of 180 days, unless a written request for an extension of the permit is received and
approved by the Building Official prior to expiration. At a minimum an inspection should be requested at least once every 180
days to assure the validity of the permit. A permit may be renewed within one year of the date of expiration for one-half the
original fee, subject to certain limitations — please call us if you have any questions.
MISTAKES?
If you think we've made an error in processing this permit or in conducting inspections pertaining to it, or find erroneous
information in the permit, please bring it to our attention immediately by filing a written request for correction within 10 working
days of discovery. All such requests should be directed to the Department of Buildings at the address found on the face of this
permit.
110
SpokaneCounty
DEPARTMENT OF BUILDING &SAFETY
West 1303 Broadway Avenue Spokane, WA 99260 (509) 456-3675
PARCEL NUMBER:
INFORMATION WORKSHEET
STREET ADDRESS: 3E'0 i <
CITY/STATE/ZIP: a
SUBDIVISION:
BLOCK: J LOT: ZONE:
LOT AREA:
DISTRICT:
F/A: WIDTH: '� 3 _._. DEPTH: / J R/W:
# OF BUILDINGS: / # OF DWELLINGS:
OWNER: 67-7'1?J ,"' y /A.) c____
WATERDISTRICT: f/B c/C'
PHONE: So cI - %a -c 1 6
MAILING ADDRESS: j. /) a / 2
h
CITY/STATE/ZIP: ® r►
r :/? 72-e
CONTACT: / —7Z/1 ,/C eoi3/3 PHONE: 5 cJ - 9j - 0 6 U
SETBACKS: - FRONT: -30 LEFT: /13 RIGHT: / REAR:
PERMIT USE: / eV. o/ L.. e C /a 1?C S
******************************************************************************
BUILDING INFORMATION
CONTRACTOR LICENSE NUMBER:
CONTRACTOR:
MAILING ADDRESS:
y _7 c2 '/ Q✓/
PHONE:
IMO
ARCHITECT/ENGINEER:
MAILING ADDRESS:
NEW: v REMODEL:
DWELL UNITS:
PHONE:
ADDITION: CHANGE OF USE:
BUILDING HGT: STORIES: /�7i
OCCUPANT LOAD:
BUILDING DIMENSIONS:
Mnii / 3'7`) - 32i2 LQ(L 903
X (WIDTH X DEPTH) SQ. FT.:
GA✓am /60 K
SPRINKLERED: CRITICAL MATERIAL:_
REQUIRED PARKING: # HANDICAP:
Please provide the following informatio7T'for Energy Code compliance: ,
Space heating type (check one)
Forced air electric Electric baseboard or wall mount Propane
L -Forced air gas Heat pump Other:
Flat ceilings R 3 Z Doors U
Vaulted ceilings R 3 F Windows U
Above grade walls R / Glazing area 0- G Z 4/0: /6, 77
Below grade walls R 1 °I Total floor area
Floor R___:: D of heated space 91
Slab on grade R Furnace efficiency rating 'ca
Please indicate on your plans: The location of the radon vent, and the location of the vent fan area.
Square footage
Main floor: % 3
Second floor:
Basement - Finished: q 6 C SL's i3
Unfinished:
C9lJ
Garage: /00
Carport:
Decks:
Additional Areas:
,4,4%' j°/-/ /// 125 :
,ef»4 ,4
kirktAAAAAAAAAAAAAAAk**�cic*flk********AAAkk�ntk�cAk**�IAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAk
LENDER/BOND HOLDER: LtiA X14 IruI !LA". I
ADDRESS: H o. c3 U I 11
rcd l04 , <1`.i Z1O Ds2f
CONTACT:
PHONE: 36-3 5� a�
PLUMBING PERMIT APPLICATION FORM
Information Worksheet
JOB STREET ADDRESS:
CITY/STATE/ZIP: PARCEL NUMBER:
OWNER: PHONE NUMBER:
MAILING ADDRESS:
(Street) (City/State) (Zip)
CONTRACTOR: LICENSE NUMBER:
PHONE NUMBER:
MAILING ADDRESS:
(Street) (City/State)
(Zip)
PLUMBING WORKSHEET/FEE SCHEDULE
DESCRIPTION
TOILETS
SHOWERS
KITCHEN SINKS
GARBAGE DISPOSAL
......................
t # S'
UTILITY SINKS
.......................................
FLOOR DRAINS
FLOOR INKS
BAR SINKS
LAWN SPRINKLER - FOR EACH BACKFLOW DEVICE
WATER SOFTENER
DRINKING FOUNTAIN
NOTE: MINIMUM PERMIT FEE IS $35.00
SIGNATURE
NUMBER
OF UNITS
X EACH
UNIT
= AMOUNT
.-j
x 6.00 =
x6.00 =
x 6.00 =
x6.00 =
x 6.00 =
x 6.00 =
x 6.00 =
x6.00=
x 6.00 =
x 6.00 =
x 6.00 =
x 6.00 =
x 6.00 =
x6.00 =
x 6.00 =
x 6.00 =
x 6.00 =
x6.00 =
x 6.00 =
/
/
/
/
/
--
--
SUBTOTAL
$
PLUS: PROCESSING FEE
+ $ 25.00
EQUALS: TOTAL PERMIT
FEE DUE
= $
Spokane County Division of Buildings '
West 1303 Broadway Avenue Spokane, WA 99260 (509) 456-3675
MECHANICAL PERMIT APPLICATION FORM
information Worksheet
JOB STREET ADDRESS:
CITY/STATE/ZIP: PARCEL NUMBER:
OWNER: PHONE NUMBER:
MAILING ADDRESS:
(Street) (City/State)
CONTRACTOR: LICENSE NUMBER:
PHONE NUMBER:
MAILING ADDRESS:
(Street) (City/State)
MECHANICAL WORKSHEET/FEE SCHEDULE
(Zip)
DESCRIPTION
ELECTRIC/DUCTWORK (SEPARATE SYSTEMS)
GAS WATER HEATER
GAS EQUIPMENT +100,000 BTU DUCTWORK)
BOILER/REFRIG 1-100M BTU
:
BOILER/REFRIG 501-1,000M BTU
:O ILEI I FF: IG 1 OOO
BOILER/REFRIG +1,750M BTU
HEAT PUMP & AIR CONDITIONER 3-15 TONS
ff:'1 W:'Y'liY`:'N1:�Y4l11��i:N riilFiii�i:;JY::;li4]4`a'Y:Y�iii�arL$i'iiiLi�:.:J •ii:(;: !'�ii4'iii�r'•:4i[�.
:::.:::.�A :•: iii: iii is i::. p:4i.�iii::v vi:4}: �::::::vi:v::i:•: ii: i:: i:: '. ii:?: iiiiiiii: ii:i:.::i :ii:}:; ...........
HEAT PUMP & AIR CONDITIONER 30-50 TONS
VENTILATING FANS
TYPE I HOOD (PER 12'OR 12' PTN. OF HOOD)
.......................................,.,
CLOTHES DRYER
GAS LOG
........................
IHI
UNLISTED GAS APPLIANCE <400,000 BTU
`.::li!Y%:IFA''::iY':t.EY►!?:ki1'':�:'lr.isM.i2�li:i`A�Ao:K:iG:ii::ItiYLJI
USED APPLIANCE <400,000 BTU
$ED At 1VG 40O BTU
AIR HANDLER <10,000 CFM
NOTE: MINIMUM PERMIT FEE IS $35.00
(Zip)
NUMBER
OF UNITS
X EACH
UNIT
= AMOUNT
x 10.00 =
x 25.00 =
x 10.00 =
x 12.00 =
x 15.00 =
x 1.00 =
x 12.00 =
x 20.00 =
x 25.00 =
x 35.00 =
x 60.00 =
x 12.00 =
x 20.00 =
x 25.00 =
x 35.00 =
x 60.00 =
x 10.00 =
x 10.00 =
x 50.00 =
x 10.00 =
x 10.00 =
x 10.00 =
x 10.00 =
x 10.00 =
x 50.00 =
x100.00 =
x 50.00 =
x100.00 =
x 12.00 =
x 15.00 =
/
3
r--
---
-
/
SUBTOTAL
$
PLUS: PROCESSING FEE
+ $ 25.00
EQUALS: TOTAL PERMIT
FEE DUE
= $
SIGNATURE
Spokane County Division of Buildings
West 1303 Broadway Avenue Spokane, WA 99260 (509) 456-3675
V)
/3'
/ 4
y /A,
4
l3�n0..-4 tog
ls/+.crrG a 5 v► i3
/s" 7:0.C,
/-2/Z 7 / I -fr::/1 si' /'xE.c, 7-
/ 3 /3
/°/Zvi.027t/
CO NG
Di2ivC-
0
0
l0
. 3g a i /ee#3/e
/%' /.) /G. a A+
6
r
tau4lirr
E. 8620 44thSpokane, Wa. 99206
�iurp�r�iian
Phone 509 926-6217 Fox 509 928-8689
Legend for Radon mitigation system
— —perforated pipe beneath slab
0 solid 4'ABS stack vent pipe
RADON SYSTEM SPECIFICATIONS ATT.
RADON MITIGATION SYSTEM
This radon mitigation system is
designed only for the specific ,lob -
site address designated. The system
is not guaranteed unless installed
by Cavalier Corporation
Sub Slab System YES
SO FT
Craulspaee System
SO FT
Jurisdiction COUNTY t'
Project Number -_
�
War n J . Riddle
Jobsite 3821 S. ROBIE
9-"�-eft ?
Builder GREMY INC.
Address 12212 E. SIOUX CIRCLE
Phone 924-9406
Environmental Protection Agency RCP 910044 1
IMIP
1ENT ;
Qiatnxlier (Engineering
moor
radon services
E. 8620 44th a
Spokane, WA 99206
Phone (509) -6217 FAX (509) 928-8689
RADON SYSTEM SPECIFICATIONS, SPOKANE COUNTY:
it
1. Perforated pipe shall be installed within the native soil
or fill (sand, gravel or soil) at a minimum depth of 1"
below the intended s I$b.
2. The pipe shall be a stfnimum diameter of 4". meet AASHTO
M252, have perforations no wider than 1/16" and have a
minimum of 2.5 square inches of total perforations per
linear foot of pipe.
3. There shall be a minieum of 10 linear feet of perforated
pipe per hundred squsie feet of slab floor space.
4. The pipe shall be laid in a continuous loop. connected at
both ends to the soli4 stack vent pipe.
5. Any slab area, which is larger than 10 square feet, which
is isolated from other slab areas by footings or other
barriers, shall have a perforated pipe installed to the
above specifications. (The pipe can be a single length
rather than a connected loop if the area is too small or
narrow to accomodate a connected loop.)
6. A stack vent of ABS, schedule 40, minimum size 4", shall
be connected to the eiib-slab piping and proceed upwards
to an exit location 011 the roof, and extending 14" above
the roof. The pipe *ball be labeled "radon vent" every
16" or less for its fell length. The pipe's attic
location shall allow a minimum of 4' of head room. When-
ever possible this exit location shall be on the backside
of the roof.
7. Any elbows in the stack vent piping shall have a
centerline radius mi*mum of 1.5 by pipe width.
8. An inline centrifugal fan, minimum 114 cfm @ 3/8" W.C.,
UL listed, manufactured specifically for radon mitigation,
maximum sone level 2.$, shall be installed in the exhaust
line, in the attic.
9. Couplings to connect the vent piping to the fan shall be
elastomeric PVC, Fermeo series 1056 or equal.
10. The fan shall be hard -wired and the breaker labeled "radon
fan".
11. All penetrations and joints in the concrete floor slab
below grade shall be sealed with caulk or grout.
12. A notice shall be permanently attached to the electrical
panel advising the owner or occupant about the radon
system and that he/slii shall test the home for radon
annually. The noticmbshall include Cavalier's name and,
phone number.
13. All craftsmanship shall be of high quality.