Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
2012, 05-23 Permit App: BLD-2012-0716 Carports, Decks, Porches
community Development Department (Staff Use Only) Permit Center CITY OF 11703 East Sprague Avenue, Suite B-3 PERMIT NUMBER: ` Spokane Valley, WA 99206 Spokane Tel: (509) 688-0036 PERMIT FEE: Valley Fax: 688-0037 permitcenitcenterPspokanevallev.orq RESIDENTIAL CONSTRUCTION PERMIT APPLICATION yi NEW CONSTRUCTION ❑ ADDITION/REMODEL El ACCESSORY BUILDING DECK Q OTHER SITE ADDRESS: /` 4/03 E .Q✓e✓(j J_ L.A n e__, • ASSESSORS PARCEL NO.: :5---M , „SwyLEGAL DESCRIPTION: eitiertlzziK is cf BUILDING OWNER NAME: ,/4,'ke 4 it.�,.. L'`9 ieg.i,c.3 NAME: VIA ke AI` PA---- ADDRESS: / ( 3 £ 1Z. e ✓ LA.44,LI_ (.„4,4vL-e CITY: 500ek--(4-4-tVA-Lt el STATE: L IA . ZIP: PHONE: �✓)9 Cqq - lo252z. ' FAX: CELL: CONTACT NAME: IAA j kC A ti PHONE: _5(>9 - CJGj l — (05z FAX: CELL: • CONTRACTOR NAME: D6t ' l�GLAuc 1-,Li / +� ei 4,1 ' • / MAILING ADDRESS: 49--/),1-/-49--/),1-/- 6 6 ci<. / /4 L "Q----- CITY: .5p)LA,Lt e , i STATE: (,4J-•'‘- ZIP: yZG' , PHONE: I FAX: CELL:5•-•C1 9-5'90 7-2n79--76, / / CONTRACTOR LICENSE No.:6/G60D;/yo843 EXPIRES:///L3/ -C�/Z CITY BUSINESS LICENSE NO.: D.S gU_S DESCRIBE THE SCOPE OF /WORK IN DETAIL� AND INDICATE USE & PROPOSED USE: L'6'7`$T✓Ltc, At-,:.4... /0� `7L - Pie 1,46/ 6e.-42.. ,7_3 e ,' - �ec% Cr z .q-/) Pr - /''0574 L,"X 6:,'' i,d/ Dr' gv.,,...<, _ L4,,.,.,a�^4 ��c k LL L,d,sF ****YOU MUST COMPLETE THE FOLLOWING**** b L /a sr= MARK N A IF NOT APPLICABLE Height to Peak: 1, Dimensi ns: , No. of Stories: , Total Habitable �� I< Space: ,Zi7o Main Floor SQ FT: Upper Floor SQ FT: Unfinished Basement SQ Finished Base ent SQ -, `FT: Al - FT: AJ/4 Garage SQ FT:, L Deck/Covered Patio SQ Impervious Surface 30%Slopes on J/4 1-T: - c2,740 Area: Af/4 Property: kr/4 No. of Bedrooms: Construction Type: Heat Source: Sewer Septic: TOTAL COST OF PROJECT: $ /L, 3 q6, cs DISCLAIMER The permitted verifies, acknowledges and agrees by their signature that: 1) if this permit is for construction or on a dwelling,the dwelling is/will be served by potable water. 2) Ownership of this City of Spokane Valley permit inure to the property owner. 3) The signatory is the property owner or has permission to represent the property owner in this transaction. 4) All construction is to be done in full compliance with the City of Spokane Valley Development code. Referenced codes are available for review at the City of Spokane Valley Permit Center. 5) The City of Spokane Valley permit is not a permit or approval for any violation of federal, state or local laws, codes or ordinances. 6) Plans or additional information may be required to be submitted and subs ently approved before this application can be processed. Signature i .1G" s- Date: --5/;2-3/ 6� / Updated 1-11-11 Page 1 of 1 http://www.spokaneva Iley.org/filestorage/124/938/210/948/1496/Bui(ding_Permit_-_Residential_11-11-11.doc RESIDENTIAL CHECK LIST DIRECTIONS: Place a check mark in box next to each document required for complete submittal. o SITE PLAN o Property lines and dimensions o Setbacks to property lines o Direction arrow pointing North and orientation to streets o Distance between buildings o Proposed/existing buildings (footprint and dimensions) o Right of way/easement location &sizes o Utilities,septic tank/drain field locations and distances o Driveway approach size and location BUILDING PLANS (3 SETS) (minimum 1/8 inch scale or completely dimensioned) ❑ Elevations(Front/Rear/Sides)with roof peak and wall height including basement: ❑ Foundation Plan (crawlspace, basement or slab on grade): o Footing sizes and locations ❑ Supporting wood cripple walls or beams o Perimeter concrete foundation wall sizes ❑ Thickened concrete pads supporting o Crawlspace ventilation beams or girder trusses O Floor Plan of each level (finished or unfinished)with dimensions: o Floor Joist direction,size and spacing ❑Window and door location and sizes o Header, beam or concrete lintel sizes ❑Window well locations if applicable o Brace wall panel locations ❑ Room usage labels o Water heater and furnace locations o Smoke detector locations o Exhaust fan locations ❑Attic and crawl space access locations o Deck or concrete patio sizes and locations ❑ Fire Wall construction ❑ Roof Plan: o Engineered truss direction and spacing ❑ Ridge, eave and valley lines o Rafter and over frame direction, size and spacing ❑ Beam and girder size and location ❑ Wall Section Detail including: Roof o Slope/roofing material/underlayment/ice dam protection o Truss or rafter size, spacing&connection o Sheathing size and type ❑Attic insulation/air space baffle/ventilation Ceiling o Joist size and spacing ❑ Size of ceiling gypsum wall board Wall o Height/top plate/stud size and spacing/sole plate ❑ Siding/exterior house wrap/anchor bolts o Exterior sheathing size and type ❑ Insulation, vapor barrier, gypsum wall board Floor o Joist size and spacing ❑ Sheathing or concrete floor size/insulation Foundation Wall o Concrete or Masonry unit width ❑ Footing bottom to finished ground level depth o Earth to wood separation distance ❑ Horizontal&vertical reinforcement if any Footing o Size ❑ Reinforcement if any Radon o Passive system with 6mil vapor barrier ❑Active system with 6 mil vapor barrier Miscellaneous Construction Details ❑ Deck: o Floor plan/side view/dimensions ❑ Footings/post/and beam size and locations o Floor Joist/decking direction, size and spacing 0 Stairway tread rise& run and nosing 0 Handrail/Guard height&spacing �!/23/ZO/.1 /,..----7 c /9 _, /011`14\- r ...._ ..._.___ _ , ,, 0 ' t ' i p/- ' 4/ _bELt‹.. ' / //10 1'p ___9> "%G ''t /q G 3 Wl tie✓ V\/.4-(- k LA+k G „4\-'1/ ,li e✓ In/ - (,k. /0 n __y • Pro Deck DesignTM �h., Plan View 14c_v\elpo: &vac fat s e x e Ado THIS BUILDING SUBJECT TO FIELD INSPECTION CORRECTIONS Warning and Important Instructions: This is not a final design plan or estimate. EDGENET, INC.assumes no responsibility for the correct use or output of this program. All information contained on this page is subject to the terms in the disclaimer located at the end of this document. Advertencia e instrcciones importantes: Esto no es un plan ni una estimaciOn final del diseno. EDGENET, INC.no asume ninguna responsibilidad del use o de la salida correcto de este programa.Toda la informaciOn contenida en esta pagina esta conforme a los terminos en la negacibn,situada en el extremo de este documento. Copyright©1989-2012 Edgenet, Inc. Page 3 of 19 Doc ID 689d8a6f-7a50-432f-8acc-15095c54e79c . . . . a Boise Cascade Single 5-1/8" x 18" BOISE GLULAM®20E-V12/AC Floor Beam\...\FB01 BC CALC®3.0 Design Report-US 1 span I No cantilevers 10/12 slope Wednesday, May 02,2012 Build 517 File Name: BC Job Name: Description:HOME DEPOT McLAUCHLIN\FB01 Address: Specifier: City,State,Zip:, Designer: Customer: Company: Code reports: AITC 117-2004, LA-01365 Misc: 1 1 BO 24-00-00 1 B1 LL 3,600 lbs DL 1,140 lbs LL 3,600 lbs DL 1,140 lbs Total of Horizontal Design Spans=24-00-00 Live Dead Snow Wind Roof Live Trib. Load Summary Tag Description Load Type Ref. Start End 100% 90% 115% 133% 125% 1 Standard Load Unf.Area(psf) L 00-00-00 24-00-00 60 15 05-00-00 Controls Summary Value %Allowable Duration Case Span Disclosure Pos.Moment 28,440 ft-lbs 65.1% 100% 1 1 -Internal Completeness and accuracy of input must End Shear 4,119 lbs 25.3% 100% 1 1 -Left be verified by anyone who would rely on Total Load Defl. L/365(0.789") 65.8% 1 1 output as evidence of suitability for Live Load Defl. U480(0.599") 74.9% 1 1 particular application.Output here based Max Defl. 0.789" 1 1 on building code-accepted design Span/Depth 16.0 78.9%n/a 1 properties and analysis methods. Installation of BOISE engineered wood products must be in accordance with Notes current Installation Guide and applicable Design meets Code minimum (L/240)Total load deflection criteria. building codes.To obtain installation Guide Design meets Code minimum(L/360) Live load deflection criteria. or ask questions,please call Design meets arbitrary(1")Maximum load deflection criteria. (800)232-0788 before installation. Minimum bearing length for BO is 1-5/8". BC CALL®,BC FRAMER®,AJSTT", Minimum bearing length for B1 is 1-5/8". ALLJOIST®,BC RIM BOARDTM BCI®, Entered/Displayed Horizontal Span Length(s)=Clear Span+ 1/2 min.end bearing+ BOISE GLULAMTM SIMPLE FRAMING 1/2 intermediate bearing SYSTEM®,VERSA-LAM®,VERSA-RIM PLUS®,VERSA-RIM®, VERSA-STRAND®,VERSA-STUD®are trademarks of Boise Cascade Wood Products L.L.C. Page 1 of 1 Pro Deck DesignTM Post View - Deck 1 �1tiAh�/ Zb tPM l w��D/t6-Tv�G (064' Colin "n n 10 ft8 in IO ft8in 10 ft8 in , _ f 10ft8in 10ft8in BnsePoint Warning and Important Instructions: This is not a final design plan or estimate. EDGENET, INC. assumes no responsibility for the correct use or output of this program. All information contained on this page is subject to the terms in the disclaimer located at the end of this document. Advertencia e instrcciones importantes: Esto no es un plan ni una estimaci6n final del diseno. EDGENET, INC. no asume ninguna responsibilidad del use o de la salida correcto de este programa.Toda la informaci6n contenida en esta pegina este conforme a los terminos en la negaciOn,situada en el extremo de este documento. Copyright©1989-2012 Edgenet, Inc. Page 6 of 19 Doc ID a47212b5-aedf-412e-a051-3704a2e82b58 • BIGra ir 3 3 Pro Deck DesignTM Post View - Deck 2 Inyvn y Fry 3ft7in 3ft7in 2-/X4 i ]ft 3 in 1 ft 3 in • BasePoint N N n � -. o. o NI N� s.n .-e Warning and Important Instructions: This is not a final design plan or estimate. EDGENET, INC.assumes no responsibility for the correct use or output of this program. All information contained on this page is subject to the terms in the disclaimer located at the end of this document. Advertencia e instrcciones importantes: Esto no es un plan ni una estimaci6n final del diseno. EDGENET, INC. no asume ninguna responsibilidad del use o de la salida correcto de este programa.Toda la informaci6n contenida en esta pagina esta conforme a los tarminos en la negaci6n,situada en el extremo de este documento. Copyright©1989-2012 Edgenet, Inc. Page 7 of 19 Doc ID a47212b5-aedf-412e-a051-3704a2e82b58 ' BIG , Pro Deck DesignTM * .,, Joist Layout View Ladle( '0 ftc'e-ka Pyr 4---.- 2H'—/ Per...1L rc ►4-oU4 �i y of flr * to , , ro , . . x a m , R , , * ro o so e e �o 'o 'a '.o so so 'o .4 .o 0 0 0 0 .o .o 0 a a. a' B. a• a' a' a' a. a' a' a' a' a' a' B' B' CPV ii ' /5 Il 6-1-5 pe r Co-I .S Q' () 4 5x 1 c- -TYP W A A A A A A A A A A A A A A A A W 6 0 0' o B a 0 B 0' 0' a' a' 0' 0' a' B B' B' 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 C 0 0 n C) n n C) n C) C) f) C) C) C) n C) fl C C) C) 3, rii 3- C a. • i(o" 0 1 ft OC A A A iJ .Me 0 J V 1ftOC 10 in OC , ,. J1 .�J B �{ 1 • 0A 0 7 Jel p� 3000 RO'l u 1•V ! 3 . 300Apima ,Notes: ,... All joist and stringer spacing dimensions are measured in OC. Warning and Important Instructions: This is not a final design plan or estimate. EDGENET, INC.assumes no responsibility for the correct use or output of this program. All information contained on this page is subject to the terms in the disclaimer located at the end of this document. Advertencia e instrcciones importantes: Esto no es un plan ni una estimaci6n final del diseno. EDGENET, INC. no asume ninguna responsibilidad del use o de la salida correcto de este programa.Toda la informaciOn contenida en esta pagina este conforme a los terminos en la negacidn,situada en el extremo de este documento. Copyright©1989-2012 Edgenet, Inc. Page 8 of 19 Doc ID a47212b5-aedf-412e-a051-3704a2e82b58 REVIEWED FOR CODE CO SPOKANE VALLEY BUILDING pLIDISI N CITY COPY