24968 DRAINAGE TECHNICAL REPORT
~
~
INLAND PACI F IC E'I`J GINEERlNG, INC.
~
- -
~
; .
7
,
-,OiUd
OMIStr (60. -Ad3d HOVOaddV
JC] 3SV3'k3H 01 HO!E!d
:.'v« `5JN1AAVkicl +Obao~d
❑3~~~~~l~~ :.rV . ' ' iif1oC]o NQI..E'.]nd1SNC7 J
, I I w 3NYI 103 rOH d
i dX3 30NVld 3 0:)'d
.031d300V~3lVa
~ f4 irl #A -(I ~ON08d '
~ .r IAAR 2 4 1~8
~ SOVOU 3J.VA]Vd
sN~-, rir ~ t .~r~HlSr~~3 S~E c,~ja~`f E~
'1►dN10IHD i~•~_..►~~
3013=10 5b-D3N19N3 AiNnCYo3~MWS
QFFiCf~L PUBLIC f)C?{;1jF,'4ENT
~POKAtiE r-(]'UNTV' EN'.aINH~'b- OFFIC~
~ OR G N ~
~ROJECTM ' 4
~
~ETURN TV V'l#~~~ ~~~~~~ER
~ ~POKANE # COEUR D'ALENE
DRAINAGE TECHNICAL REPORT
for the
RIVERWALK 9TH
ADDITION PUD
MARCH 1998
-0 y&Z38
Prepared for:
K.C. CONSTRUCTION
P.O. Box 1455
Hayden Lake, Idaho 83855
Prepared By :
Inland Pacific Engineering Comparry
707 W. 7th Avenue Suite 200
Spokane, WA 99204
(509) 458-6840
DRAINAGE REPORT
for the
Riverwalk 9th Addition PUD
Plat
Spokane County, Washington
March 1998 I
The design improvcments shown in this set of plans and calculations conform to the
applicable editions of the Spokane County Standards for Road and Sewer Construction
and tbe Spokane County Guidelines for Stormwater Management. All design deviations
have been approved by the Spokane County Engineer. I approve these plans
(calculations) for construction.
This report has been prepazed by Susan K. Murphy, E.I.T. of Inland Pacific Engineering Company
under the direction of the undersigned professional engineer whose seal and signature appear hereon.
Todd R. Whipple, P.E.
Riverwalk 9th Addition PUD
Drainage Narrative
GENERAL
Riverwalk 9th Addition PUD Plat is a 10.88 acre development of 38 single family residential lots
and 5 tract areas located north and east of the intersection of Indiana Avenue and Barker Road,
witlun Spokane County, Washington. The site is currently vacant with field grass, alfalfa and
fallow fields as the predominant land cover and vegetation. Single family residential
development lies directly to the south and east. A vicinity and location map have been included
within the technical section of this document.
PURPOSE ~
The purpose of this report is to determine the extent of storm drainage facilities which will be
required to dispose of the increase in stormwater runoff created by the development of the
Riverwalk 9th Addition plat. The storm drainage facilities on this project will be designed to
dispose of runoff from a ten year design storm, as required by the Spokane County Guidelines
for Stormwater Management, though calculations are also included to verify that the facilities
also contain the 50-year storm. This development is within the Aquifer Sensitive Area of
Spokane County and is subject to'208' requirements. For this project, the 10- and 50-year curve
from the Spokane, Medical Lake, Reardon, Cheney and Rockford intensity curves was used, as
well as the SCS iso-pluvial rainfall curves.
A1VAL YSIS METHODOLOGY
Per the Spokane County Guidelines for Stormwater Management, the Rational Method, which is
recommended for basins less than ten acres in size, will be used to determine the peak discharges
and runoff volumes for all onsite basins.
PRUJECT DESCRIPTION
This phase of the Riverwalk 9th Addition plat comprises 38 lots of the approved 393 lots in the
approved preliminary plat and SEPA documents. The Riverwalk 9th Addition subdivision is
located in the NE 1/4 of the SW 1/4 of Section 8, T. 25 N., R. 45 E., W.M. within Spokane
County, Washington.
TOPOGRAPHY
The existing site naturally drains to the north and west, sloping gently towards the Spokane River
from Indiana Avenue. Within the plat the natural topography was used as much as possible to
Inland Pacific Engineering Comparry 1 Riverwalk 9th Addition Drainage Report
I
,
route storm drainage. However, due to the flat slopes and the County's minimum requirements
for slope, the roadway profiles have been forced down to facilitate drainage by localizing low
spots for pond placement. Due to the flat slopes encountered, no concentrated pre-existing flows
were observed nor were there any signs that anything other than sheet flow and ground
absorption have occurred on this site.
The general slopes within this plat vary from flat to nearly flat with the maximum existing slope
at 0.01 ft./ft. Generally, the area within this platted portion of the overall preliminary plat would
be characterized as flat. For development purposes as stated the natural sloping was used for
design and is maintained as possible throughout the project.
SOILS
As can be seen from the accompanying soils map from the Spokane County Soils Survey as
performed by the SCS, the site consists of one type of soils within the Class B type. This soil
type is described as follows.
GgA - Garrison gravelly loam, 0 to 5 percent slopes: Soils within this soil type are some what
excessively drained soils formed in gravelly glacial outwash material from a variety of igneous
rock. Surface runoff is slow, and the hazard of erosion is slight. Spokane County Guidelines for
Stormwater Manap-ement indicate this to be a Soil Group Type B and pre-approved for drywell
installation.
Hydrologic Soil Classifccation - B
DRAINAGE NARRATIVE
Offsite
Based upon the general geographic tendencies of this site, no appreciable amounts of offsite
flows are expected for this phase.
Onsite
As this plat is within the aquifer sensitive azea of Spokane County all onsite drainage will be
collected and treated using the "208" runoff inethod as described in the Spokane County
Guidelines for Stormwater Management. To facilitate this analysis the Riverwalk 9th Addition
plat was divided into 17 permanent sub-basins ( A through P). Basins have been combined
where practical to utilize the same pond. Table 1 lists the basins and pond combinations for easy
reference.
Inland Pacific Engineering Company 2 Riverwalk 9th Addltion Drainage Report
Table No. 1
WEIGHTED "C"" SUMMARY
Basins Total Area Street Imp. Weighted
(SF/AC) Area (SFIAC} "C"
A 48590/1.12 10748/0.25 0.32
B 16900/0.39 4598/0.11 0.36
C 64650/1.48 11380/0.26 0.28
D 32500/0.75 6174/0.14 0.29
E 28040/0.64 11277/0.26 0.45
F 24650/0.57 5161 /0.12 0.31
G 27650/0.63 6092/0.14 0.32
HI, JK 60250/1.38 11470/0.26 0.29
P 13560/0.31 6502/0.15 0.51
"208" Calculations
Within each basin the streets are divided into sub-basins by high and low roadway profiles.
These facilities capture upstream stormwater runoff from the impervious street surface and direct
the runoff into grassy '208' ponds. As shown on the '208' calculation worksheets included, the
'208' storage volume provided is adequate to perform '208' treatment for the runoff created by the
first half inch of rainfall.
Cur6 Inlets and Catch Basin Calculations
It is necessary to check the adequacy of the curb inlets, inlets or catch basins provided to divert
the runoff from the gutter into the '208' ponds. Should these be required, the curb inlet
calculation sheets included show the required lengths of curb openings, as well as the adequacy
of the inlet grates or catch basin grates. For curb inlets greater than 4.0', either multiple curb
inlets are added or the curb inlets are lengthened as required.
DRAINAGE CALCULATIUNS SUMMARY
Calculations have been included for Drainage Basin considerations such as Peak Flow, Time of
Concentration, "208" sizing, drywell requirements, inlet sizing and curb inlets, as well as culverts
Inland Pacific Engineering Company 3 Rivenvalk 9th Addition Drainage Report
- ,
and pipe flows, some of which are summarized below with the remaining calculations included
in the appendix.
Within the calculation section and where it has been determined necessary for clarity, several
sketches, as well as details from the plans have been incorporated to demonstrate assumptions
and conclusions.
BASIN DESCRIPTIONS
Basins A through P
Within this plat, and due to the general geographic features, several basic assumptions were
followed and can be used to describe each basin. First, due to the relative flatness of the plat and
project vicinity, minimum road grade is limited to 0.008 ft./ft; second, large tract ponds if
practical will be used in the open space area; third, all other ponds will be of the lot pond
configuration; fourth, that where practical, drywells will be minimized by combining basins and
providing piping between ponds. All of these steps have been used in various basins throughout
the drainage design of this project.
There are four basins, L, M, N, and O which have been analyzed in the predeveloped and
developed condition to verify that the developed flow is less than the predeveloped flow. The
four basins are backyard areas whose natural slope directs flow away from the front yards,
toward the plat boundary and is therefore not included in any of the other basins. They have been
isolated and labeled on the basin map, and due to landscaping presumed to be installed in the
developed condition, the runoff will be lower than the predeveloped state. No treatment is
required in this condition.
Inland Pacific Engineering Company 4 Riverwalk 9th Addition Drainage Repon
Table No. 2- Pond and 208 Basin Summary
Rivervvalk 9th Addition - BASIN SUMMARY
Basin ' Pond 20$ Volume 208 Area 208 Area Drywclls
Reyuired (cf) Requircd (sf) Pravided (sf)* Requirecl
,
A A 377 754 1147 1-"B"
B B 192 3 84 422 1-"A"
„
C C 474 948 992 1-"B"
D D 257 514 524 1-"A"
E E 470 940 975 1-"A"
F F 215 430 491 1-"A"
G G 254 508 593 1-"A"
HI H 133 266 272 -
HI I 95 190 190 -
JK J 87 174 178.5 -
JK K 163 326 370.5 -
HI, JK - - - _ 1 _ "B„
P P 271 542 542 1-44A "
`208' area is calculated as (bottom area)(0.5'); side slope volume is not included.
- Type A is a Spokane Standard Drywell - Single Depth, Capacity 0.3 cfs
- Type B is a Spokane Standard Drywell - Double Depth, Capacity 1.0 cfs
Inland Pacific Engineering Company s Riverwalk 9th Addition Drainage Repon
,
Table No. 3- Curb Inlet/Catch Basin Summai-tv
Xtiverwalk 8th Addition Piat - Curb Inlet and Catch Basins Summary
Basin Pond Curb Inlet Catch Basin
Condition Condition)
~
A A Sump -
B B Sump -
C C Sump Sump
,
D D Sump -
E E Sump Sump
F F Sump -
G G Sump -
HI H Continuous -
,
HI I Sump -
JK J Sump -
JK K Continuous -
P P Continuous -
Per Spokane County Guidelines curb drops in a sump condition have a capacity of 4.0 cfs
Per WSDOT Hydraulics Manual, Grate Inlet, has a sump capacity of 13.0 cfs
NOTE:
Only curb drop and grate calculations were performed for those
cases "On Grade"; cur6 drops and catch basins in sump condition
are assumed to handle 4.0 cfs.
Inland Pacific Engineering Comparry 6 Riverwalk 9th Addition Drainage Report
-
_ - /
Yr~W1~ 11w_ -
t
. ' ~1ap ~'N' J
er 1:
~ 290
~ Pe~s~eo
Oa~s A+e.
~
~ .
cw. a
~
1i w ~ ~ ~ ~ i ~ ~ ~ ~ ~ 3 ~
ci ~ or.«... ; M.e..a
~ .M~ TAM~...
t~M
lrMd Ma ~ WeN~let Aw-
pIhM~My Aw. MW p
VAL* #A... c) fis c)rrfi:ir 1s ~ ~ .
a - . .
. w~.~e....
Cr4M Mt. •
~ j
~
P IO J T
' . /
~ • .
LIPCA ION .
fC Cl
~ ~ ~ A... _ ~ I •
t
Ave. ~ O
Sp
c ~i f
~ A V ~v wubn ~w. ~
M+tlen An.
, Wew11Aa.
d ~ w
Av1. Lin1~ ~w. 3 ~ .
~++g• VatleY Vlew
: ` .~.~+pi'
s..~. ~ ~
cr ~ Golf Caurse
~ ,~sL"' aA.w. w.. ~ ►vd`M ` f ' .
wf •
MaadowWood
~ Golf Caurse
G 1'•l`il Al'i'Cti
a
~ Poat nw,wF
Ot(lce a~.ov Uberty Uke
a ' S PubNc Goll Course
Ya a jK. ~ ~ 1~ Aw, t H1 Mr.
A i
b~d .
1sIAw ZS iC 'M~O~ ~ t l~,~b'L Me.
~ _ ~
j~, ~ e..4,. a.
.r
N~ A~r j~ ~ p / a
~ Cr,uer. q is d ~
. ~
~ ywvM. oc ~ ~
Posl .
Q11tce
~ M* ►w. , ~ MI~ Aw. ' .
l.illrrh' l.;il:c ~ a~
G~ `
~ u~r +
. .
Weighted Runoff Coefficient Calculation
Project: Riverwalk 9th Addition
Basin: A IPE Job 96238
Total Area (acres): 1.12 Designer: SKM
Imp. Area (acres): 0.25 Date: 09/22
Grass Area (acres): 0.87
Imp. Area "C": 0.90
Grass Area "C": 0.15
(Imp. Area)(Imp. "C")= 0.2250
(Grass Area)(Grass "C")= 0.1305
1.1200 0.3555
Weighted "C"= 0.3555
0.32
1.1200
Weighted Runoff Coefficient Calculation
Project: Riverwalk 9th Addition
Basin: B IPE Job 95238
Total Area (acres): 0.39 Designer: SKM
Imp. Area (acres): 0.11 Date: 09/22
Grass Area (acres): 0.28
Imp. Area "C": 0.90
Grass Area "C": 0.15
(Imp. Area)(Imp. "C")= 0.0990
(Grass Area)(Grass "C")= 0.0420
0.3900 0.1410
Weighted "C"= 0.1410
0.36
0.3900
Weighted Runoff Coefficient Calculation
Project: Rivenn►alk 9th Addition
Basin: C IPE Job 96238
Total Area (acres): 1.48 Designer: SKM
Imp. Area (acres): 0.26 Date: 09/22
Grass Area (acres): 1.22
Imp. Area "C": 0.90
Grass Area "C": 0.15
(Imp. Area)(Imp. "C")= 0.2340
(Grass Area)(Grass "C")= 0.1830
1.4800 0.4170
Weighted "C"= 0.4170
0.28
1.4800
Weighted Runoff Coefficient Calculation
Project: Riverwalk 9th Addition
Basin: D IPE Job 96238
Total Area (acres): 0.75 Designer: SKM
Imp. Area (acres): 0.14 Date: 09/22
Grass Area (acres): 0.61
Imp. Area "C": 0.90
G rass Area "C": 0.15
(Imp. Area)(Imp. "C")= 0.1260
(Grass Area)(Grass "C")= 0.0915
0.7500 0.2175
Weighted "C"= 0.2175
0.29
0.7500
Weighted Runoff Coefficient Calculation
Project: Riverwalk 9th Addition
Basin: E IPE Job 96238
Total Area (acres): 0.64 Designer: SKM
Imp. Area (acres): 0.26 Date: 09/22
Grass Area (acres): 0.38
Imp. Area "C": 0.90
Grass Area "C": 0.15
(Imp. Area)(Imp. "C")= 0.2340
(Grass Area)(Grass "C")= 0.0570
o.s4oo 0.2910
Weighted "C"= 0.2910
0.45
0.6400
Weighted Runoff Coefficient Calculation
Project: Riverwalk 9th Addition
Basin: F IPE Job 96238
Total Area (acres): 0.57 Designer: SKM
Imp. Area (acres): 0.12 Date: 09/22
Grass Area (acres): 0.45
Imp. Area "C": 0.90
Grass Area "C": 0.15
(Imp. Area)(Imp. "C")= 0.1080
(Grass Area)(Grass "C")= 0.0675
0.5700 0.1755
Weig hted "C"= 0.1755
0.31
0.5700
Weighted Runoff Coefficient Calculation
Project: Riverwalk 9th Addition
Basin: G IPE Job 96238
Total Area (acres): 0.63 Designer: SKM
Imp. Area (acres): 0.14 Date: 09/22
Grass Area (acres): 0.49
Imp. Area "C": 0.90
Grass Area "C": 0.15
(Imp. Area)(Imp. "C"}= 0.1260
(Grass Area)(Grass "C")= 0.0735
0.6300 0.1995
Weighted "C"= 0.1995
0.32
0.6300
Weighted Runoff Coefficient Calculation
Project: Riverwalk 9th Addition
Basin: H IPE Job 96238
Total Area (acres): 0.07 Designer: SKM
Imp. Area (acres): 0.07 Date: 09122
Grass Area (acres): 0.00
Imp. Area "C": 0.90
Grass Area "C": 0.15
(Imp. Area)(Imp. "C")= 0.0630
(Grass Area)(Grass "C")= 0.0000
0.0700 0.0630
Weighted "C"= 0.0630
0.90
0.0700
Weighted Runoff Coefficient Calculation
Project: Riverwalk 9th Addition
Basin: I IPE Job 96238
Total Area (acres): 0.46 Designer: SKM
Imp. Area (acres): 0.13 Date: 09/22
Grass Area (acres): 0.33
Imp. Area "C": 0.90
Grass Area "C": 0.15
(Imp. Area)(Imp. "C")= 0.1170
(Grass Area)(Grass C")_ - 0.0495 ~
0.4600 0.1665
Weighted "C"= 0.1665
0.36
0.4600
Weighted Runoff Coefficient Calculation
Project: Riverwalk 9th Addition
Basin: J IPE Job 96238
Total Area (acres): 0.92 Designer: SKM
Imp. Area (acres): 0.14 Date: 09/22
Grass Area (acres): 0.78
Imp. Area "C": 0.90
Grass Area "C": 0.15
(Imp. Area)(Imp. "C")= 0.1260
(Grass Area)(Grass "C")= 0.1170 ~
0.9200 0.2430
Weighted "C"= 0.2430
0.26
0.9200
Weighted Runoff Coefficient Calculation
Project: Riverwalk 9th Addition
Basin: K I PE Job 96238
Total Area (acres): 0.09 Designer: SKM
Imp. Area (acres): 0.09 Date: 09/22
Grass Area (acres): 0.00
Imp. Area "C": 0.90
Grass Area "C": 0.15
(Imp. Area)(Imp. "C")= 0.0810
(Grass Area)(Grass "C")= 0.0000
0.0900 0.0810
Weighted "C"= 0.0810
0.90
0.0900
Weighted Runoff Coefficient Catculation
Project: Riverwalk 9th Addition
Basin: HI & JK IPE Job 96238
Total Area (acres): 1.38 Designer: SKM
Imp. Area (acres): 0.26 Date: 09/16
Grass Area (acres): 1.12
Imp. Area "C": 0.90
Grass Area "C": 0.15
(imp. Area)(Imp. "C")= 0.2340
(Grass Area)(Grass "C")= 0.1680
1.3800 0.4020
Weig hted "C"= 0.4020
0.29
1.3800
Weighted Runoff Coefficient Calculation
Project: Riverwalk 9th Addition
Basin: P IPE Job 96238
Total Area (acres): 0.31 Designer: SKM
Imp. Area (acres): 0.15 Date: 03/19
Grass Area (acres): 0.16
Imp. Area "C": 0.90
Grass Area "C": 0.15
(Imp. Area)(Imp. "C")= 0.1350
(Grass Area)(Grass "C")= 0.0240
0.3100 0.1590
Weighted "C"= 0.1590
0.51
0.3100
BOWSTRING METHOD PROJECT: Riverwalk 9th Addition
PEAK FLOW CALCULATION PROJECT Riverwalk 9th Addition DETENTION BASIN DESIGN BASIN: A
BASIN: A 10-Year Design Storm DESIGNER: S. Murphy
Tot. Area 1.12 Acres DATE: 09122
Imp. Area 10748 SF
C = 0.32
Time Increment (min) 5
CASE 1 Time of Conc. (min) 7.00
Outflow (cis) 1
120 ft. Overiand Flow Design Year Flow 10
Area (acres) 1.12
Cl = 0.15 Impervious Area (sq ft) 10748
L= 120 ft. 'C' Factor 0.32
n= 0.40 '208' Volume Provided 573.5
S= 0.020 Area' C 0.358
Tc = 4.95 min., by Equation 3-2 of Guidelines
Time Time Inc. Intens. Q Devel, Vol.ln Vol.Out Storege
202 ft. Gutter flow (min) (sec) (iNhr) (cfs) (cu ft) (cu ft) (cu ft)
-
-
Z1= 50.0 For Z2 7.00 420 2.68 0.96 541 420 121
Z2 = 3.5 Type B =1.0
n= 0.016 Rolled = 3.5 5 300 3.18 1.14 458 300 158
S= 0.010 10 600 224 0.80 596 600 -4
15 900 1.77 0.63 662 900 -238
d= 0.148 ft. 20 1200 1.45 0.52 698 1200 -502
25 1500 1.21 0.43 112 1500 -788
A R Q Tc Tc total I Qc 30 1800 1.04 0.37 724 1800 -1076
35 2100 0.91 0.33 732 2100 -1368
0.59 0.07 0.96 2.05 7.00 2.68 0.96 40 2400 0.82 0.29 747 2400 -1653
45 2700 0.74 0.27 754 2700 -1946
Qpeak for Case 1= 0.96 ds 50 3000 0.66 0.24 766 3000 -2234
55 3300 0.64 0.23 790 3300 -2510
60 3600 0.61 0.22 818 3600 -2782
CASE 2 65 3900 0.60 4.22 669 3900 -3031
70 4200 0.58 0.21 903 4200 -3297
Case 2 assumes a Time of Concentratian less than 5 minutes so that the 75 4500 0.56 020 932 4500 -3568
peak flow =.90(3.18)(Imp. Area) = 0.71 cfs 80 4800 0.53 0.19 939 4800 -3861
85 5100 0,52 0.19 977 5100 -4123
90 5400 0.50 0.18 993 5400 -4407
So, the Peak flow for the Basin is the greater of the two flows, 95 5700 0.49 0.18 1026 5700 -4674
0.96 cfs 100 6000 0.48 0.17 1057 6000 -4943
208' DRAINAGE POND CALCULATIONS
Required'208' Storage Volume
= Impervious Area x.5 in I 12 inlft 448 cu ft
208' Storage Volume Provided 573.5 cu ft
DRYVNELL REQUIREMENTS -10 YR. DESIGN STORM
Maximum Storage Required by Bowstnng 158 cu ft
Number and Type of Drywells Required 0 Single
1 Double
BOWSTRING METHOD PROJECT: Riverwalk 9th Addition
PEAK FLOW CALCULATION PROJECT Riverwalk 9th Addition DETENTION BASIN DESIGN BASIN: B
BASIN: B 10-Year Design Storm DESIGNER: S. Murphy
Tot. Area 0.39 Acres DATE: 09115
Imp.Area 4598 SF
C = 0.36
Time Increment (min) 5
CASE 1 Time of Conc. (min) 6,59
Outflow (cfs) 0.3
65 ft, Overiand Flow Design Year Flow 10
Area (acres) 0.39
Ct = 0.15 Impenrious Area (sq ft) 4598
L= 65 ft. 'C' Faclor 0,36
n= 0.40 '208' Volume Provided 211
S= 0.020 Area ' C 0.140
Tc = 3.43 min., by Equation 3-2 of Guidelines
Time Time Inc. Intens. Q Devel, Vol.ln Vol.Out Storage
249 ft. Gutter flow (min) (sec) (iNhr) (cfs) (cu ft) (cu fl) (cu ft)
Z1= 50.0 For Z2 6.59 395 2.75 0,39 205 119 86
Z2 = 3.5 Type B =1.0
n= 0.016 Rolled = 3.5 5 300 3.18 0.45 179 90 89
S= 0.010 10 600 2.24 0.31 231 180 51
15 900 1.77 0.25 257 270 -13
d= 0.106 fl. 20 1200 1.45 0,20 272 360 -88
25 1500 1.21 0.17 218 450 -172
A R Q Tc Tc total I Qc 30 1800 1.04 0.15 282 540 -258
35 2100 0.91 0.13 285 630 -345
0.30 0,05 0.39 3.16 6.59 2.75 0.39 40 2400 0.82 0.12 292 720 -428
45 2700 0.74 0.10 294 810 -516
Qpeak for Case 1= 0.39 cfs 50 3000 0.68 0.10 299 900 -601
55 3300 0.64 0.09 309 990 -681
60 3600 0.61 0.09 320 1080 -760
CASE 2 65 3900 0.60 0.08 340 1170 -830
70 4200 0.58 0.08 353 1260 -907
Case 2 assumes a Time of Concentration less than 5 minutes so that the 75 4500 0.56 0.08 364 1350 -986
peak flow =.90(3.18)(Imp. Area) = 0.30 cfs 80 4800 0.53 0,07 367 1440 -1073
85 5100 0.52 0.07 382 1530 -1148
90 5400 0.50 0.07 389 1620 -1231
So, the Peak flow for the Basin is the greater of the two flows, 95 5700 0.49 0.07 401 1710 -1309
0.39 cfs 100 6000 0.48 0.07 413 1800 -1387
208' DRAINAGE POND CALCULATIONS
Required '208' Storage Volume
= Impenrious Area x.5 in /12 iNfl 192 cu ft
208' Storage Vatume Provided 211 cu ft
DRYWELL REQUIREMENTS -10 YEAR DESIGN STORM
Maximum Storage Required by Bowstring 89 cu fl
Number and Type oi Drywells Required 1 Single
0 Double
BOWSTRING METHOD PROJECT: Rivenrralk 9th Addition
PEAK FLOW CALCULATION PROJECT Riverwalk 9th Addition DETENTION BASIN DESIGN BASIN: C
BASIN: C 10-Year Design Storm DESIGNER: S. Murphy
Tot. Area 1.48 Acres DATE: 09115
Imp. Area 11380 SF
C = 0.28
Time inaement (min) 5
CASE 1 Time of Conc. (min) 6.96
Outflow (cfs) 1
50 ft. Overland Flow Design Year Flow 10
Area (acres) 1.48
Ct = 0.15 Imperoious Area (sq ft) 11380
L= 50 ft. 'C' Factor 0,28
n= 0.40 '208' Volume Provided 496
S= 0.020 Area' C 0.414
Tc = 2.93 min., by Equaiion 3-2 of Guidelines
Time Time Inc. Intens. Q Devel. Val.ln Vol.Out Storage
447 fl. Gutter flow (min) (sec) (inlhr) (cfs) (cu ft) (cu ft) (cu ft)
Z1= 50.0 For Z2 6.96 417 2.69 1.11 623 417 206
Z2 = 3.5 Type B =1.0
n= 0.016 Rolled = 3.5 5 300 3.18 1.32 530 300 230
S= 0.013 10 600 2.24 0.93 689 600 89
15 900 1.77 0.73 764 900 -136
d= 0.150 ft. 20 1200 1.45 0.60 806 1200 -394
25 1500 1.21 0.50 823 1500 -671
A R Q Tc Tc total I Qc 30 1800 1.04 0,43 837 1800 -963
35 2100 0.91 0.38 845 2100 -1255
0.60 0.07 1.11 4.03 6.96 2.69 1.11 40 2400 0.82 0.34 864 2400 -1536
45 2100 0.74 0.31 871 2700 -1829
Qpeak for Case 1= 1.11 cfs 50 3000 0.68 0.28 885 3000 -2115
55 3300 0.64 0.27 913 3300 -2387
60 3600 0.61 0.25 946 3600 -2654
CASE 2 65 3900 0.60 0.25 1005 3900 -2895
70 4200 0.58 0.24 1044 4200 -3156
Case 2 assumes a Time of Concentration less than 5 minutes so that lhe 75 4500 0.56 0.23 1077 4500 -3423
peak flow =.90(3.18)(Imp. Area) = 0.75 cfs 80 4800 0.53 0.22 1085 4800 -3715
85 5100 0.52 0.22 1130 5100 -3970
90 5400 0.50 0.21 1148 5400 -4252
So, the Peak flow for the Basin is the greater of the two Flows, 95 5700 0,49 0.20 1186 5700 -4514
1.11 cfs 100 6000 0.48 0.20 1222 6000 -4778
208' DRAINAGE POND CALCULATIONS
Required '208' Storage Volume
= Impervious Area x.5 in I 12 iNft 474 cu ft
208' Storage Volume Provided 496 cu ft
DRYWELL REQUIREMENTS -10 YEAR DESIGN STORM
Maximum Storage Required by Bowstring 230 cu ft
Number and Type of Drywells Required 0 Single
1 Double
BOWSTRING METHOD PROJECT: Riverwalk 9th Addition
PEAK FLOW CALCULATION PROJECT Riverwalk 9th Addition DETENTION BASIN DESIGN BASIN: D
BASIN: D 10-Year Design Stortn DESIGNER: S. Murphy
Tot. Area 0.75 Acres DATE: 09J15
Imp. Area 6174 SF
C = 0.29
Time Increment (min) 5
CASE 1 Time of Canc. (min) 6.87
Outflow (cfs) 0.3
120 ft. Overland Flow Design Year Flow 10
Area (acres) 0.75
Ct = 0.15 Impervious Area (sq ft) 6174
L= 120 ft. 'C' Facta 0.29
n= 0.40 '208' Volume Provided 262
S= 0.020 Area' C 0.217
Tc = 4.95 min., by Equation 3-2 of Guidelines
Time Time Inc. Intens, Q Devel. Vol.ln Vol.Out Storage
200 ft, Gutter flow (min) (sec) (iNhr) (cts) (cu ft) (cu ft) (cu R)
Z1= 50.0 For 72 6.87 412 2.70 0.59 325 124 201
Z2 = 3.5 Type B =1.0
n= 0.016 Rolled = 3.5 5 300 3.18 0.69 278 90 188
S= 0.016 10 600 2.24 0.49 361 180 181
15 900 1.77 0.38 400 270 130
d= 0.113 ft. 20 1200 1.45 0.32 423 360 63
25 1500 1.21 0.26 432 450 -16
A R Q Tc Tc total I Qc 30 1800 1.04 0.23 439 540 -101
35 2100 0.91 0.20 443 630 -187
0.34 0.06 0.59 1.93 6.87 2.70 0.59 40 2400 0.82 0.18 453 720 _267
45 2700 0.74 0.16 457 810 -353
Qpeak for Case 1= 0.59 cfs 50 3000 0.68 0.15 464 900 -436
55 3300 0.64 0.14 479 990 -511
60 3600 0.61 0.13 496 1080 -584
CASE 2 65 3900 0.60 0,13 527 1170 -643
70 4200 0.58 0.13 548 1260 -712
Case 2 assumes a Time of Concentration less lhan 5 minutes so lhat the 75 4500 0.56 0,12 565 1350 -785
peak Bow =.90(3.18)(Imp. Area) = 0.41 cfs 60 4800 0.53 0.12 569 1440 -871
85 5100 0.52 0.11 593 1530 -937
90 5400 0.50 0.11 603 1620 -1017
So, the Peak flow for lhe Basin is the greater of the two flows, 95 5700 0.49 0.11 622 1710 •1088
0 59 cis 100 6000 0.48 0.10 641 1800 -1159
208' DRAINAGE POND CALCULATIONS
Required'208' Storage Volume
= Impervious Area x.5 in 112 inlft 257 cu ft
208' Storage Volume Provided 262 cu ft
DRYWELL REQUIREMENTS -10 YEAR DESIGN STORM
Maximum Storage Required by Bowstring 201 cu fl
Number and Type of Drywells Required 1 Single
0 Double
BOWSTRING METHOD PROJECT: Riverwalk 9th Addition
PEAK FLOW CALCULATION PROJECT Riverwalk 9th Addition DETENTION BASIN DESIGN BASIN: E
BASIN: E 10-Year Design Storm DESIGNER: S. Murphy
Tot. Area 0.64 Acres DATE: 03123
Imp. Area 11277 SF
C = 0.45
Time Increment (min) 5
CASE 1 Time of Conc, (min) 5.00
Outflow (cfs) 0.3
17 ft. Overland Flow Design Year Flow 10
Area (acres) 0.64
Ct = 0.15 Impervious Area (sq ft) 11277
L= 17 ft. 'C' Factor 0.45
n= 0.02 '208' Volume Provided 487.5
S= 0.020 Area' C 0.288
Tc = 0.22 min., by Equation 3-2 of Guidelines
Time Time Inc. Intens. Q Devel. Vol.ln Vol.Out Storage
135 ft. Gutter flow (min) (sec) (iNhr) (cfs) (cu ft) (cu ft) (cu ft)
Z1 = 50,0 For Z2 5.00 300 3,18 0.92 368 90 278
Z2 = 3.5 Type B =1.0
n= 0.016 Rolled = 3.5 5 300 3.18 0.92 368 90 278
S= 0.010 10 600 2.24 0,65 453 180 273
15 900 1.77 0.51 511 270 241
d= 0.146 ft. 20 1200 1.45 0,42 544 360 184
25 1500 121 0.35 558 450 108
A R Q Tc Tc total I Qc 30 1800 1.04 0.30 570 540 30
35 2100 0.91 0.26 577 630 -53
0.57 0.07 0.92 1,39 5.00 3.18 0.92 40 2400 0.82 0.24 591 720 -129
45 2700 0.74 0.21 597 610 -213
Qpeak for Case 1= 0.92 cfs 50 3000 0.68 0.20 607 900 -293
55 3300 0.64 0.18 627 990 -363
60 3600 0.61 0.18 650 1080 -430
CASE 2 65 3900 0.60 0.17 692 1110 -478
70 4200 0,58 0.17 719 1260 -541
Case 2 assumes a Time of Concentration less than 5 minutes so that the 75 4500 0.56 0.16 742 1350 -608
peak flow =.90(3.18)(Imp. Area) = 0.74 cfs 80 4800 0.53 0.15 748 1440 -692
85 5100 0.52 0.15 719 1530 -751
90 5400 0.50 0.14 792 1620 -828
So, the Peak flow for the Basin is the greater of the two flows, 95 5700 0.49 0.14 819 1710 -891
0.92 cfs 100 6000 0.48 0.14 844 1800 -956
208' DRAINAGE POND CALCULATIONS
Required'208' Storage Volume
= Impervious Area x.5 in 112 inlft 470 cu ft
208' Storage Volume Provided 487.5 cu ft
DRYWELL REQUIREMENTS -10 YEAR DESIGN STORM
Maximum Storage Required by Bowstring 278 cu ft
Number and Type of Drywells Required 1 Single
0 Double
BOWSTRING METHOD PROJECT: Riverwalk 9th Addition
PEAK FLOW CALCULATION PROJECT Riverwalk 9lh Addition DETENTION BASIN DESIGN BASIN: F
BASIN F 10-Year Design Storm DESIGNER: S. Murphy
Tot. Area 0.57 Acres DATE: 09115
Imp. Area 5161 SF
C = 0.31
Time Increment (min) 5
CASE 1 Time of Conc. (min) 5.95
Outflow (cfs) 0.3
140 ft. Overland Flow Design Year Flow 10
Area (acres) 0.57
Ct = 0,15 Impenrious Area (sq ft) 5161
L= 100 ft. 'C' Factor 0.31
n= 0.40 '208' Volume Provided 223.5
S= 0.020 Area' C 0.177
Tc = 4.44 min., by Equation 3-2 of Guidelines
Time Time Inc. Intens, Q Devel. Vol.ln Vol.Out Storage
146 fl. Gutter flow (min) (sec) (iNhr) (cis) (cu ft) (cu ft) (cu ft)
-
Z1= 50.0 ForZ2 5.95 357 2,90 0.51 246 107 139
Z2 = 3.5 Type B =1.0
n= 0.016 Rolled = 3.5 5 300 3,18 0.56 226 90 136
S= 0.014 10 600 224 0.40 286 180 106
15 900 1.77 0.31 319 270 49
d= 0.109 ft. 20 1200 1.45 0.26 339 360 -21
25 1500 121 0.21 347 450 -103
A R Q Tc Tc total I Qc 30 1800 1.04 0.18 353 540 -187
- - - 35 2100 0.91 0.16 357 630 -273
0.32 0.05 0.51 1.52 5.95 2.90 0.51 40 2400 0.82 0,14 365 720 -355
45 2700 0.74 0,13 369 810 -441
Qpeak for Case 1= 0.51 cfs 50 3000 0.68 0,12 375 900 -525
55 3300 0.64 0.11 387 990 -603
60 3600 0.61 0.11 401 1080 -679
CASE 2 65 3900 0.60 0.11 426 1170 -744
70 4200 0.58 0.10 443 1260 -817
Case 2 assumes a Time of Concentration less than 5 minutes so that the 75 4500 0.56 0.10 457 1350 -893
peak flow =.90(318)(Imp. Area) = 0.34 cfs 80 4800 0.53 0.09 461 1440 -979
85 5100 0.52 0.09 480 1530 -1050
90 5400 0.50 0.09 488 1620 -1132
So,1he Peak flow for lhe Basin is the greater of the two flows, 95 5700 0.49 0.09 504 1710 -1206
0.51 cfs 100 saoa 0.48 0.08 519 1600 -1281
208' DRAINAGE POND CALCULATIONS
Required'208' Storage Volume
= Imperoious Area x.5 in ! 12 in/ft 215 cu ft
208' Storage Volume Provided 223.5 cu ft
DRYWELL REQUIREMENTS -10 YEAR DESIGN STORM
Maximum Storage Required by Bowstring 139 cu fl
Number and Type of Drywells Required 1 Single
0 Double
BOWSTRING METHOD PROJECT: Riverwalk 81h AddiGon
PEAK FLOW CALCULATION PROJECT Riverwalk Sth Addition DETENTION BASIN DESIGN BASIN: G
BASIN: G 10•Year Design Storm DESIGNER: S. Murphy
Tot. Area 0.63 DATE: 09115
Imp. Area 6092 SF
C = 0.32
Time Increment (min) 5
CASE 1 Time of Conc. (min) 5.00
Outflow (cfs) 0.3
50 ft. Overland Flow Design Year Flow 10
Area (acres) 0.63
Ct = 0.15 Impervious Area (sq ft) 6092
L= 50 ft. 'C' Factor 0.32
n= 0.40 '208' Volume Provided 296.5
S= 0.020 Area' C 0.202
Tc = 2.93 min., by Equation 3-2 of Guidelines
Time Time Inc. Intens. Q Devel, Vol.ln Vol.Out Storage
210 ft. Gutter flow (min) (sec) (iNhr) (cfs) (cu ft) (cu ft) (cu ft)
Z1 = 50.0 For Z2 5.00 300 3.18 0.64 258 90 168
Z2 = 3.5 Type B =1.0
n= 0.016 Rolled = 3,5 5 300 3.18 0,64 258 90 168
S= 0.016 10 600 224 0.45 317 180 137
15 900 1,77 0.36 358 270 88
d= 0.117 ft. 20 1200 1.45 0.29 381 360 21
25 1500 1.21 024 391 450 -59
A R Q Tc Tc total I Qc 30 1800 1.04 0.21 399 540 -141
35 2100 0,91 0.18 404 630 -226
- - -
0.36 0.06 0,64 1.98 5.00 3.18 0.64 44 2400 0.82 0,17 414 720 -306
45 2700 0.74 0.15 418 810 -392
Qpeak 1or Case 1= 0.64 cfs 50 3000 0.68 0.14 425 900 -475
55 3300 0.64 0.13 439 990 -551
60 3600 0.61 0.12 455 1080 -625
CASE 2 65 3900 0.60 0.12 484 1170 -686
70 4200 0.58 0,12 503 1260 -757
Case 2 assumes a Time of Concentration less than 5 minutes so that the 75 4500 0.56 0,11 520 1350 -830
peak flow =.90(3.18)(Imp. Area) = 0.40 cfs 80 4840 0.53 0.11 524 1440 -916
85 5100 0.52 0.10 545 1530 -985
90 5400 0.50 0.10 555 1620 -1065
So, the Peak flow for the Basin is the greater of the rivo flows, 95 5700 0.49 0.10 573 1710 -1137
0.64 cfs 100 6000 0.48 0.10 590 1800 -1210
208' DRAINAGE POND CALCULATIONS
Required'208' Storage Volume
= Impervious Area x.5 in ! 12 inlft 254 cu ft
208' Storage Volume Provided 296.5 cu ft
ORYWELL REQUIREMENTS -10 YEAR DESIGN STORM
Maximum Storage Required by Bowstring 168 cu ft
Number and Type of Drywells Required 1 Single
0 Double
BOWSTRING METHOD PROJECT: Rivervvalk 9th Addition
PEAK FLOW CALCULATION PROJECT Riverwalk 9th Addition DETENTION BASIN DESIGN BASIN: H
BASIN: H 10-Year Design Storm DESIGNER: S. Murphy
Tot. Area 0.01 Acres DATE: 09116
Imp. Area 3188 SF
C = 0.90
Time Increment (min) 5
CASE 1 Time of Conc. (min) 5.00
Outflow (cfs) 0
40 ft. Overland Flow Design Year Flow 10
Area (aaes) 0.07
Ct = 0.15 Impervious Area (sq ft) 3188
L= 40 ft. 'C' Factor 0.9
n= 0.40 '208' Volume Provided 136
S= 0.020 Area " C 0.063
Tc = 2.56 min., by Equation 3-2 of Guidelines
Time Time Inc. Intens. Q Devel. Vol.ln Vol.Out Storage
143 ft. Gutter flow (min) (sec) (iNhr) (cfs) (cu ft) (cu ft) (cu ft)
Z1= 50.0 FotZ2 5.00 300 3.18 0.20 81 0 81
Z2 = 3.5 Type B =1.0
n= 0.016 Rolled = 3.5 5 300 3.18 0.20 81 0 81
S= 0.011 10 600 2.24 0.14 99 0 99
15 900 1.77 0.11 112 0 112
d= 0.080 ft. 20 1200 1.45 0.09 119 0 119
25 1500 1.21 0.08 122 0 122
A R Q Tc Tc total I Qc 30 1800 1.04 0.07 125 0 125
35 2100 0.91 0.06 126 0 126
- -
-
0.17 0.04 0.20 2.09 5.00 3.18 0.20 40 2400 0.82 0.05 129 0 129
45 2700 0.74 0.05 131 0 131
Qpeak for Case 1= 020 cfs 50 3000 0.68 0.04 133 0 133
55 3300 0.64 0.04 137 0 137
60 3600 0.61 0.04 142 0 142
CASE 2 65 3900 0.60 0.04 151 0 151
70 4200 0.58 0.04 157 0 157
Case 2 assumes a Time of Concentration less than 5 minutes so that the 75 4500 0.56 0.04 162 0 162
peak Oow =.90(3,18)(Imp. Area) = 0.21 cfs 80 4800 0.53 0.03 164 0 164
85 5100 0.52 0,03 170 0 170
90 5400 0.50 0,03 173 0 173
So, the Peak flaw for the Basin is the greater of the iwo flows, 95 5700 0.49 0.03 179 0 179
0.21 cfs 100 6000 0.48 0,03 185 0 185
208' DRAINAGE POND CALCULATIONS
Required'208' Storage Volume
= Imperoious Area x.5 in 112 iNft 133 cu ft
208' Storage Volume Prov'rded 136 cu ft
DRWVELL REQUIREMENTS -10 YEAR DESIGN STOR
Maximum Storage Required by Bowstring 170 cu ft
Number and Type of Drywells Required ERR Single
ERR Double
BOWSTRING METHOD PROJECT: Riverwalk 9th Addition
PEAK FLOW CALCULATION PROJECT Riverwalk 9th Addiiion DETENTION BASIN DESIGN BASIN: I
BASIN I 10-Year Oesign Storm DESIGNER: S. Murphy
Tot. Area 0.46 Aaes DATE: 09118
Imp. Area 5472 SF
C = 0.36
Time Increment (min) 5
CASE 1 Time of Conc. (min) 5.43
Outflow (cfs) 0.3
40 ft. Overland Flow Design Year Flow 10
Area (acres) 0.46
Ct = 0.15 Impervious Area (sq ft) 5472
L= 40 ft. 'C Factor 0.36
n= 0.40 '208' Volume Provided 231
S= 0.020 Area ' C 0.166
Tc = 2.56 min., by Equation 3-2 of Guidelines
Time Time Inc. Intens. Q Devel. Vol.ln Vol.Out Storage
250 ft. Gutter flow (min) (sec) (inmr) (cfs) (cu ft) (cu ft) (cu ft)
Z1= 50.0 For Z2 5.43 326 3.07 0.51 222 98 124
Z2 = 3.5 Type B =1.0
n= 0.016 Rolled = 3.5 5 300 3.18 0.53 212 90 122
S= 0.011 10 600 2.24 0.37 264 180 84
15 900 1.77 0.29 296 270 26
d= 4.115 ft, 20 1200 1.45 0.24 315 360 -45
25 1500 1.21 0.20 323 450 -127
A R Q Tc Tc total I Qc 30 1800 1.04 0.17 329 540 -211
35 2100 0.91 0.15 333 630 -297
0.35 0.06 0.51 2.87 5.43 3.07 0.51 40 2400 0.82 0.14 341 720 -379
45 2700 0.74 0.12 344 810 -466
Qpeak for Case 1= 0,51 cfs 50 3000 0.68 0.11 350 900 -550
55 3300 0.64 0.11 361 990 -629
60 3600 0.61 0.10 375 1080 -705
CASE 2 65 3900 0.60 0.10 399 1170 -771
70 4200 0,58 0.10 414 1260 -846
Case 2 assumes a Time of Concentration less than 5 minutes so that the 75 4500 0.56 0.09 428 1350 -922
peak flow =.90(3.18)(Imp. Area) = 0.36 cfs 80 4800 0.53 0.09 431 1440 -1009
85 5100 0.52 0.09 449 1530 -1081
90 5400 0.50 0.08 456 1620 -1164
So, the Peak flow for the Basin is the greater of the lwo flows, 95 5100 0.49 0,08 472 1710 -1238
0.51 cfs 100 6000 0.48 0.08 486 1800 -1314
' 208' DRAINAGE POND CALCULATIONS
Required'208' Storage Volume
= Impervious Area x.5 in 112 iNft 218 cu ft
208' Storage Volume Provided 231 cu fl
DRYWELL REQUIREMENTS -10 YEAR DESIGN STORM
Maximum Slorage Required by Bowstring 124 cu ft
Number and Type of Drywells Required 1 Single
0 Double
BOWSTRING METH00 PROJECT: Riverwalk 9th Addition
PEAK FLOW CALCULATION PROJECT Rivervwalk 9th Addition DETENTION BASIN DESIGN BASIN: J
BASIN; J 10-Year Design Stonn DESIGNER: S. Murphy
Tot. Area 0.92 Acres DATE: 09115
Imp. Area 5998 SF
C = 0.14
Time Inaement (min) 5
CASE 1 Time of Conc. (min) 6.84
Outflow (cfs) 0,3
50 ft, Overland Flow Design Year Flow 10
Area (acres) 0.92
Ct = 0.15 Impenrious Area (sq ft) 5998
L= 50 ft. 'C' Fador 0.14
n= 0,40 '208' Volume Provided 274.5
S= 0.020 Area " C 0.129
Tc = 2.93 min., by Equation 3-2 of Guidelines
Time Time Inc. Intens. Q Devel. Val.ln Vol.Out Storage
311 fl. Gutter flow (min) (sec) (iNhr) (cfs) (cu ft) (cu fl) (cu ft)
Z1 = 50.0 For Z2 6.84 411 2.71 0.35 192 123 69
Z2 = 3.5 Type B =1.0
n= 0.016 Rolled = 3.5 5 300 3.18 0.41 165 90 75
S= 0.011 10 600 2.24 0.29 213 180 33
15 900 1.77 0.23 237 270 -33
d= 0.100 fl. 20 1200 1.45 0.19 250 360 -110
25 1500 1.21 0.16 256 450 -194
A R Q Tc Tc total I Qc 30 1800 1.04 0.13 260 540 -280
35 2100 0.91 0.12 263 630 -367
0,27 0.05 0,35 3.92 6.84 2,71 0.35 40 2400 0.82 0.11 268 720 -452
45 2700 0.74 0.10 271 810 -539
Qpeak for Case 1= 0.35 cfs 50 3000 0.68 0.09 275 900 -625
55 3300 0.64 0.08 284 990 -706
60 3600 0.61 0.08 294 1080 -786
CASE 2 65 3900 0.60 0.08 312 1170 -858
70 4200 0.58 0.07 324 1260 -936
Case 2 assumes a Time of Concentration less than 5 minutes so that the 75 4500 0.56 0.07 335 1350 -1015
peak flow =.90(3.18)(Imp. Area) = 0.39 cfs 80 4800 0.53 0.07 337 1440 -1103
85 5100 0.52 0.07 351 1530 -1179
90 5400 0.50 0.06 357 1620 -1263
So, the Peak flow for the Basin is the greater of the two flows, 95 5700 0.49 0.06 369 1710 -1341
0.39 cfs 100 6000 0.48 0.06 380 1800 -1420
208' DRAINAGE POND CALCULATIONS
Required'208' Storage Volume
= Impervious Area x.5 in I 12 iNft 250 cu ft
208' Storage Volume Provided 274.5 cu ft
DRYWELL REQUIREMENTS -10 YEAR DESIGN STORM
Maximum Storage Required by Bowstring 75 cu ft
Number and Type oi Drywells Required 1 Single
0 Double
BOWSTRING METHOD PROJECT: Riverwalk 9th Addition
PEAK FLOW CALCULATION PROJECT Riverwalk 9th Addition OETENTION BASIN DESIGN BASIN: K
BASIN: K 10-Year Design Stortn DESIGNER: S. Murphy
Tot. Area 0,09 Acres DATE: 09J15
Imp. Area 3908 SF
C = 0,90
Time Inaement (min) 5
CASE 1 Time of Conc. (min) 5.00
Outflow (cfs) 0
50 ft. Overland Flow Design Year Flow 10
Area (aaes) 0.09
Ct = 0.15 Impervious Area (sq ft) 3908
L= 50 ft. 'C' Fador 0.9
n= 0.40 '208' Volume Provided 185
S= 0,020 Area " C 0.081
Tc = 2.93 min., by Equation 3-2 of Guidelines
Time Time Inc. Intens. Q Devel. Vol.ln Vol.Out Storage
143 ft. Gutter flow (min) (sec) (iNhr) (cfs) (cu ft) (cu ft) (cu ft)
Z1= 50.0 For Z2 5.00 300 3.16 0.26 104 0 104
Z2 = 3.5 Type B =1.0
n= 0.016 Rolled = 3.5 5 300 3.18 0.26 104 0 104
S= 0.011 10 600 2.24 0.18 127 0 127
15 900 1.77 0.14 144 0 144
d= 0.089 ft. 20 1200 1.45 0,12 153 0 153
25 1500 1.21 0.10 157 0 157
A R Q Tc Tc total I Qc 30 1800 1.04 0.06 160 0 160
35 2100 0.91 0.07 162 0 162
0.21 0.04 0.26 1.95 5.00 3.18 0.26 40 2400 0.82 0.07 166 0 166
45 2700 0.74 0.06 168 0 168
Qpeak for Case 1= 0.26 cfs 50 3000 0.68 0.06 171 0 171
55 3300 0.64 0.05 176 0 176
60 3600 0.61 0.05 183 0 183
CASE 2 65 3900 0.60 0.05 194 0 194
70 4200 0.58 0.05 202 0 202
Case 2 assumes a Time of Concentratian less than 5 minutes so that the 75 4500 0.56 0.05 209 0 209
peak flow =.90(3.18)(Imp. Area) = 0.26 cfs 80 4800 0.53 0.04 210 0 210
85 5100 0.52 0.04 219 0 219
90 5400 0.50 0.04 223 0 223
So, lhe Peak flow for the Basin is the greater of the two flows, 95 5700 0.49 0.04 230 0 230
0.26 cfs 100 6000 0.48 0.04 237 0 237
208' DRAINAGE POND CALCULATIONS
Required'208' Storage Volume
= Impervious Area x.5 in ! 12 inlft 163 cu ft
208' Storage Volume Pravided 185 a+ ft
DRYWELL REQUIREMENTS -10 YEAR DESIGN STOR
Maximum Storage Required by Bowstring 219 cu ft
Number and Type of Drywells Required ERR Single
ERR Double
BOWSTRING METHOD PROJECT: Riven+ralk 9th Addition
PEAK FLOW CALCULATION PROJECT Riverwalk 9th Addition DETENTION BASIN DESIGN BASIN: Combined HI 6 JK
BASIN: Combined HI 6 JK 10-Year Design Storm DESIGNER: S. Murphy
Tot. Area 1.38 Aaes DATE: 09116
Imp. Area 11470 SF
C = 0.29
Time Inaement (min) 5
CASE t Time of Conc. (min) 5.83
Outflow (cfs) i
50 ft. Overland Flow Design Year Flow 10
Area (acres) 1.38
Ct = 0.15 Impervious Area (sq ft) 11470
L= 50 ft. 'C' Factor 0.29
n= 0.40 '208' Volume Provided 505.5
S= 0.020 Area' C 0.400
Tc = 2.93 min., by Equa6on 3-2 of Guidelines
Time Time Inc. Intens. Q Devel. Vol.ln Vol.Out Storage
311 ft. Gutter flow (min) (sec) (iNhr) (cfs) (cu ft) (cu ft) (cu ft)
Z1= 50.0 For Z2 5.83 350 2.95 1.18 552 350 203
Z2 = 3.5 Type B =1.0
n= 0.016 Rolled = 3.5 5 300 3.18 1.27 512 300 212
S= 0.011 10 600 2.24 0.90 644 600 44
15 900 1.77 0.71 722 900 -178
d= 0.157 ft. 20 1200 1.45 0.58 765 1200 435
25 1500 1.21 0.48 784 1500 -716
A R Q Tc Tc total I Qc 30 1800 1.04 0.42 799 1800 -1001
35 2100 0.91 0.36 808 2100 -1292
0.66 0.08 1.18 2.90 5.83 2.95 1.18 40 2400 0.82 0.33 827 2400 -1573
45 2700 0.74 0.30 835 2700 -1865
Qpeak for Case 1= 1.18 cfs 50 3000 0.68 0.27 849 3000 -2151
55 3300 0.64 0.26 876 3300 -2424
60 3600 0.61 0.24 908 3600 -2692
CASE 2 65 3900 0.60 0.24 965 3900 -2935
70 4200 0.58 0.23 1002 4200 -3198
Case 2 assumes a Time of Concentration less than 5 minutes so that the 75 4500 0,56 0.22 1035 4500 -3465
peak flow =.90(3.18)(Imp. Area) = 0.75 cfs 80 4800 0.53 0.21 1043 4800 -3757
65 5100 0.52 0.21 1086 5100 -4014
90 5400 0.50 0.20 1104 5400 -4296
So, the Peak flow for the Basin is the greater of the two flows, 95 5700 0.49 0.20 1141 5700 -4559
1 18 cfs 100 6000 0.48 0,19 1175 6000 -4825
, 208' DRAINAGE POND CALCULATIONS
Required '208' Slorage Volume
,r,
= Impervious Area x.5 in ! 12 iNft 478 cu ft
206' Starage Volume Provided 505.5 cu ft
DRYWELL REQUIREMENTS -10 YEAR DESIGN STORM
Maximum Storage Required by Bowstring 212 cu ft
Number and Type of Drywells Required 0 Single
1 Double
BOWSTRING METHOD PROJECT: Riverwalk 9th Addition
PEAK FLOW CALCULATION PROJECT Riverwalk 9th Addition DETENTION BASIN DESIGN BASIN: Predeveloped L
BASIN; Predeveloped L 10-Year Design Storm DESIGNER; S. Murphy
Tot. Area 0.76 Acres DATE: 09118
Imp, Area 0 SF
C = 0.30
Time Inaement (min) 5
CASE 1 Time of Conc. (min) 14.78
Outflow (cfs) 0
470 ft. Overiand Flow Design Year Flow 10
Area (acres) 0.76
Ct = 0.15 Impervious Area (sq ft) 0
L= 470 ft. 'C' Facior 0.3
n = 0.40 '208' Volume Provided
S= 0.008 Area' C 0228
Tc = 14.78 min., by Equation 3-2 of Guidelines
Time Time Inc. Intens. Q Devel. Vol.ln Vol.Qut Storage
0 ft. Gutter flow (min) (sec) (iNhr) (cfs) (cu ft) (cu ft) (cu ft)
Z1= 50.0 For Z2 14.78 887 1.80 0.41 486 0 486
Z2 = 3.5 Type 8 =1.0
n= 0.016 Rolled = 3.5 5 300 3.18 0.73 291 0 291
S= 0.005 10 600 2.24 0.51 411 0 411
15 900 1.77 0.40 485 0 485
d= 0.122 ft. 20 1200 1.45 0.33 496 0 496
25 1500 121 0.28 497 0 497
A R Q Tc Tc total I Qc 30 1640 1.04 0.24 498 0 498
35 2100 0.91 0.21 498 0 498
0.40 0.06 0.41 0.00 14.78 1.80 0.41 40 2400 0.82 0.19 505 0 505
45 2700 0.74 0.17 506 0 506
Qpeak for Case 1= 0.41 cis 50 3000 0.68 0.16 512 0 512
55 3300 0.64 0.15 526 0 526
60 3600 0.61 0.14 543 0 543
CASE 2 65 3900 0.60 0.14 575 0 575
70 4200 0.58 0.13 595 0 595
Case 2 assumes a Time of Concentration less than 5 minutes so that Ihe 75 4540 0.56 0.13 613 0 613
peak flow =.90(3.18)(Imp. Area) = 0.00 cfs 80 4800 0.53 0.12 616 0 616
85 5100 0.52 0.12 640 0 640
90 5400 0.50 0.11 650 0 654
So, the Peak flow for the Basin is the greafer of the two flows, 95 5100 0.49 0.11 670 0 670
0.41 cfs 100 6000 0.48 0,11 690 0 690
208' DRAINAGE POND CALCULATIONS
Required'208' Storage Volume
= Impervious Area x.5 in 112 inlfl 0 cu ft
208' Storage Volume Provided cu ft
DRYWELL REQUIREMENTS -10 YEAR DESIGN STORM
Maximum Storage Required by Bowstring 640 cu ft
Number and Type of Drywells Required 0 Single
ERR Double
B(}WSTRING METH4D F'ROJECT: Riverwalk 9Eh Addfiqn
PEAK FLOW CRLCIJLATIC}N PRC?JEGT Riverwalk 9kh AddiEion bETENTION BASIN DESIGN BASIN: Qeveloped L
6,4SIN: Developed L 10-Y20f De51gPl St41'Rl DESIGNER: 5 Murphy
Tot, Area 6.76 Acres DATE: 09l18
lmp. Area D SF
C- D.15
Time incremenl (min) 5
CASE 1 Time raf Conc. (min) 14.78
Outflow (cfs) 0
470 it. Overland Flaw Design Year Flow 10
Area (acres) 016
Ct = 0,15 Imperviaus Area (sq ft) fl
L = 470 ft. 'C' Factnr 0,15
n ~ 0.44 '208' Valume Prauided
S= 0,408 Area e C 0.114
Tc ~ 14.78 min., by Equation 3-2 of Guidelines
Tirne Time Ine. In#ens. Q DeveL VaOJn Vol.Dut Storage
0ft, Gutter flow (min) (sec) (iNhr) f cfsy f cu ft1 {cu R) itai fl}
Z1= 50.0 For Z2 14.78 887 1.80 0,20 243 4 243
Z2 = 3.5 Type B =1.0
n= OM6 Rolled = 3,5 5 300 3.18 0.36 145 0 146
s= 0.005 10 600 2.24 0.26 205 a 205
15 900 1.77 0,20 242 tl 242
d= 4.093 ff. 20 1200 1.45 0.17 248 4 248
25 1500 1.21 0.14 248 0 248
A R a Tc Tctotal I Qc 34 1840 1.G4 0,12 249 0 249
=a==-==- ==a= 35 2100 4.91 0.10 249 0 249
0.23 0.05 0.20 0.00 14,78 1.80 024 40 2400 a.82 4,09 253 0 253
45 2700 0.74 0.08 253 0 253
Qpeak for Case 1- 0_20 cfs 50 3000 0.68 0.08 266 0 256
55 3300 O.fi4 0.07 253 0 263
60 3600 O.61 0,07 279 d 271
CRSE 2 65 3900 0.60 0.07 287 0 287
lD 4200 0.58 0A7 298 0 298
Case 2 assurnes a Tirne of Concentratinn less than 5 minutes sa that ¢he 75 4500 0.56 0.06 307 Q 307
peak flnw =.90(3.18)(Imp. Area) = 4,00 cfs 80 4800 0.53 OAfi 308 0 308
85 5100 0.52 0.06 320 o 320
90 5400 0.54 0.48 325 Q 325
Sa, the Peax now for !he 8asin is the grealer n(the twa flows, 95 5700 0.49 0.46 335 0 335
0.2 0 cfs 100 6000 0.48 0.05 345 0 345
208" aRAINAt3E POND CALCIJLATI{]NS
Required'208' Starage VaEume
= Imperviuus Area x.5 in 112 ir/ft U cu ft
208' Slarage Volume Pravided cu ft
aRYWELL REraUIREMENTS-1aYEAR pESIGN SroRM
Maximum Starage Required by Bowstring 320 cu ft
,
~r
' Nurnber and 7ype of Drywells Requ~red 0 Single
ERR Qouble
BOWSTRING METHOD PROJECT: Riveiwalk 9th Addifion
PEAK FLOW CALCULATION PROJECT Riverwalk 9ih Addftion DETENTION BASIN DESIGN BASIN: Predeveloped M
BASIN: Predeveloped M 10-Year Design Storm DESIGNER: S. Murphy
Tot. Area 0.16 Acres DATE: 09118
Imp. Area 0 SF
C = 0.30
Time Increment (min) 5
CASE 1 Time of Conc. (min) 5.00
Outflow (cfs) 0
80 ft. Overland Flow Design Year Flow 10
Area (acres) 0.16
Ct = 0.15 Impervious Area (sq ft) 0
L= 60 ft. 'C' Factor 0.3
n = 0.40 '208' Volume Provided
S= 0.010 Area ' C 0.048
Tc = 4.78 min., by Equation 3-2 of Guidelines
Time Time Inc. Intens. Q Devel. Vol.ln Vol.Out Storage
0 ft. Gutter flow (min) (sec) (in/hr) (cfs) (cu ft) (cu ft) (cu ft)
-
Z1 = 50.0 For Z2 5.00 300 3.18 0.15 61 0 61
Z2 = 3.5 Type B =1.0
n= 0,016 Rolled = 3.5 5 300 3.18 0.15 61 0 61
S= 0,005 10 600 2.24 0.11 75 0 75
15 900 1.71 0.08 85 0 85
d= 0,065 ft. 20 1200 1.45 0.07 91 0 91
25 1500 121 0.06 93 0 93
A R Q Tc Tc total I Qc 30 1800 1.04 0.05 95 0 95
35 2100 0.91 0.04 96 0 96
0.19 0.04 0.15 0.00 5.00 3.18 0.15 40 2400 0.82 0.04 98 0 98
45 2700 0.74 0.04 100 0 100
Qpeak for Case 1= 0.15 cfs 50 3000 0.68 0.03 101 0 101
55 3300 0.64 0.03 105 0 105
60 3600 0.61 0.03 108 0 108
CASE 2 65 3900 0.60 0.03 115 0 115
70 4200 0.58 0.03 120 0 120
Case 2 assumes a Time of Concentration less than 5 minutes so that the 75 4500 0.56 0.03 124 0 124
peak flow =.90(3.18)(Imp. Area) = 0.00 cfs 80 4800 0.53 0.03 125 0 125
85 5100 0.52 0.02 130 0 130
90 5400 0.50 0.02 132 0 132
So, the Peak 8ow for the Basin is the greater of the two flows, 95 5700 0.49 0.02 136 0 136
0.15 cfs 100 6000 0.48 0.02 141 0 141
208' DRAINAGF POND CALCULATIONS
Required'208' Storage Volume
= Impervious Area x.5 in ! 12 inlft 0 cu ft
208' Storage Volume Provided cu ft
DRYWELL REQUIREMENTS -10 YEAR DESIGN STORM
Maximum Storage Required by 8owstnng 130 cu ft
Number and Type of Drywells Required 0 Single
ERR Double
BOWSTRING METHOD PROJECT: Riverwalk 9th Addition
PEAK FLOW CALCULATION PROJECT Riverwalk 9th Addition DETENTION BASIN DESIGN BASIN: Developed M
BASIN Developed M 10-Year Design Storm DESIGNER: S. Murphy
Tot. Area 0.16 Acres DATE: 09118
Imp. Area 0 SF
C = 0.15
Time Increment (min) 5
CASE 1 Time of Conc. (min) 5.00
Outflow (cfs) 0
80 ft. Overland Flow Design Year Flow 10
Area (aaes) 0.16
Ct = 0.15 Impervious Area (sq ft) 0
L= 80 ft. 'C' Factor 0.15
n = 0.40 '208' Volume Provided
S= 0.010 Area' C 0.024
Tc = 4.78 min., by Equation 3-2 of Guidelines
Time Time Inc. Intens. Q Devel, Vol.ln Vol.Out Staage
0 ft. Gutter flow (min) (sec) (iNhr) (cfs) (cu ft) (cu ft) (cu ft)
Z1= 50.0 For Z2 5.00 300 3.18 0.08 31 0 31
Z2 = 3.5 Type B =1.0
n= 0.016 Rolled = 3.5 5 300 3.18 0.08 31 0 31
S= 0,005 10 600 2.24 0.05 38 0 38
15 900 1.77 0.04 43 0 43
d= 0,065 ft. 20 1200 1.45 0.03 45 0 45
25 1500 121 0.03 47 0 47
A R Q Tc Tc total I Qc - 30 1800 1.04 0.02 47 0 47
35 2100 0.91 0.02 48 0 48
0.11 0.03 0,08 0.00 5.00 3.18 0.08 40 2400 0.82 0.02 49 0 49
45 2700 0.74 0.02 50 0 50
Qpeak for Case 1= 0.08 cfs 50 3000 0.68 0.02 51 0 51
55 3300 0.64 0.02 52 0 52
60 3600 0.61 0.01 54 0 54
CASE 2 65 3900 0,60 0.01 58 0 58
70 4200 0.58 0.01 60 0 60
Case 2 assumes a Time of ConcenVation less than 5 minutes so lhat the 75 4500 0.56 0.01 62 0 62
peak flow =.90(3.18)(Imp. Area) = 0.00 cfs 80 4800 0.53 0.01 62 0 62
85 5100 0.52 0.01 65 0 65
90 5400 0.50 0.01 66 0 66
So, the Peak flow for the Basin is the greater of the twa flows, 95 5700 0,49 0,01 68 0 68
0.08 cfs 100 6000 0.48 0.01 70 0 70
208' DRAINAGE POND CALCULATIONS
Required '208' Storage Volume
= Impervious Area x.5 in ! 12 iNft 0 cu ft
208' Storage Volume Provided cu ft
DRYVYELL REQUIREMENTS -10 YEAR DESIGN STORM
Maximum Storage Required by Bowstring 65 cu ft
Number and Type of Orywells Required 0 Single
ERR Double
BOWSTRING METHOD PROJECT: Riverwalk 9th Addition
PEAK FLOW CALCULATION PROJECT Riverwalk 9lh Addition DETENTION BASIN DESIGN BASIN: Predeveloped N
BASIN: Predeveloped N 10-Year Design Storm DESIGNER: S. Murphy
Tot. Area 0.26 Acres DATE: 09N8
Imp. Area 0 SF
C = 0.30
Time Incremenl(min) 5
CASE 1 Time of Conc. (min) 5.00
Outflow (cfs) 0
50 ft. Overland Flow Design Year Flow 10
Area (aaes) 0.26
Ct = 0.15 Impervious Area (sq ft) 0
L= 50 ft. 'C' Factor 0.3
n = 0.40 '208' Valume Provided
S= 0.008 Area " C 0.078
Tc = 3.85 min., by Equation 3-2 of Guidelines
Time Time Inc. Intens. Q Devel. Vol.ln Vol.Oul Storage
0 ft. Gutter flow (min) (sec) (iNhr) (cfs) (cu ft) (cu ft) (cu ft)
Z1= 50.0 For Z2 5.00 300 3.18 0.25 100 0 100
Z2 = 3.5 Type B =1.0
n= 0.016 Rolled = 3.5 5 300 3.18 0.25 100 0 100
S= 0.005 10 600 2.24 0.17 123 0 123
15 900 1.77 0.14 138 0 138
d= 0.102 ft. 20 1200 1.45 0.11 141 0 147
25 1500 1.21 0.09 151 0 151
A R a Tc Tc total I Qc 30 1800 1.04 0.08 154 0 154
35 2100 0.91 0.07 156 0 156
0.28 4.05 0.25 0.00 5.00 3.18 0,25 40 2400 0.82 0.06 160 0 160
45 2700 0,14 0.06 162 0 162
Opeak for Case 1= 0.25 cfs 50 3000 0,68 0.05 165 0 165
55 3300 0.64 0.05 170 0 170
60 3600 0.61 0.05 176 0 176
CASE 2 65 3900 0.60 0.05 187 0 187
70 4200 0.58 0.05 195 0 195
Case 2 assumes a Time of Concentration less than 5 minules so that the 75 4500 0.56 0.04 201 0 201
peak flow =.90(318)(Imp. Area) = 0.00 cfs 80 4800 0.53 0.04 203 0 203
85 5100 0.52 0.04 211 0 211
90 5400 0.50 0.04 215 0 215
So, the Peak flow for the Basin is the greater of the two flows, 95 5700 0.49 0.04 222 0 222
0.25 cfs 100 6000 0,48 0.04 228 0 228
208' DRAINAGE POND CALCULATIONS
Required '208' Storage Volume
= Imperoious Area x.5 in /12 iNft 0 cu ft
208' Storage Volume Provided cu ft
DRYWELL REQUIREMENTS -10 YEAR DESIGN STORM
Maximum Storage Required by Bowstring 211 cu ft
Number and Type of Drywells Required 0 Single
ERR Double
BOWSTRING METHOD PROJECT: Riverwalk 9th Addition
PEAK FLOW CALCULATION PROJECT Riverwalk 9th Addition DETENTION BASIN DESIGN BASIN: Developed N
BASIN: Developed N 10-Year Design Storm DESIGNER: S. Murphy
Tot. Area 0.26 Aaes DATE: 09118
Imp. Area 0 SF
C = 0.15
Time Inaement (min) 5
CASE 1 Time of Conc. (min) 5.00
Outflow (cfs) 0
50 ft. Overland Flow Design Year Flow 10
Area (aaes) 0.26
Ct = 0.15 Imperoious Area (sq ft) 0
L= 50 ft. 'C' Factor 0.15
n = 0.40 '208' Volume Provided
S= 0,008 Area' C 0.039
Tc = 3.85 min., by Equation 3-2 of Guidelines
Time Time Inc. Intens. Q Devel. Vol.ln Vol.Out Storage
0 fl. Gutter flow (min) (sec) (iNhr) (cfs) (cu fl) (cu ft) (cu ft)
-
-
Z1= 50.0 For Z2 5.00 300 3.18 0.12 50 0 50
Z2 = 3.5 Type B =1,0
n= 0.016 Rolled = 3.5 5 300 3.18 0.12 50 0 50
S= 0,005 10 600 224 0.09 61 0 61
15 900 1.77 0.07 69 0 69
d= 0.078 ft. 20 1200 1.45 0.06 14 0 74
25 1500 1.21 0.05 76 0 76
A R Q Tc Tc total I Qc 30 1800 1.04 0.04 77 0 77
- - 35 2100 0.91 0.04 18 0 78
-
0.16 0.04 0,12 0.00 5.00 3,18 0.12 40 2400 0.82 0.03 80 0 80
45 2700 0.74 0.03 81 0 81
Qpeak for Case 1= 0.12 cfs 50 3000 0.68 0.03 82 0 82
55 3300 0.64 0.02 85 0 85
60 3600 0.61 0.02 88 0 88
CASE 2 65 3900 0.60 0.02 94 0 94
70 4200 0.58 0.02 97 0 97
Case 2 assumes a Time of Concentration less than 5 minutes so that the 75 4540 0.56 0.02 101 0 101
peak Oow =.90(3.18)(Imp. Area) = 0.00 cfs 80 4800 0.53 0.02 101 0 101
85 5100 0,52 0.02 105 0 105
90 5400 0.50 0.02 107 0 107
So, the Peak flow for the Basin is the greater of the two flows, 95 5700 0.49 0,02 111 0 111
0.12 cfs 100 6000 0.48 0.02 114 0 114
208' DRAINAGE POND CALCULATIONS
Required '208' Storage Volume
= Impervious Area x.5 in f 12 iNft 0 cu ft
208' Storage Volume Provided cu ft
DRYWELL REQUIREMENTS -10 YEAR DESIGN STORM
Maximum Storage Required by Bowstnng 105 cu ft Number and Type of Drywells Required 0 Single
ERR Double
BOWSTRING METHOD PROJECT: Riverwalk 9th Addition
PEAK FLOW CALCULATION PROJECT Riverwalk 9lh Addition DETENTION BASIN DESIGN BASIN: Predeveloped 0
BASIN: Predeveloped 0 10-Year Design Storm DESIGNER: S. Murphy
Tot. Area 0.85 Acres DATE: 09118
Imp. Area 0 SF
C = 0.30
Time Increment (min) 5
CASE 1 Time of Conc. (min) 5.46
Outflow (cfs) 0
100 ft. Overiand Flow Design Year Flow 10
Area (acres) 0.85
Ct = 0.15 Impervious Area (sq ft) 0
L= 100 ft. 'C' Factor 0.3
n = 0.40 '208' Volume Provided
S= 0.010 Area ' C 0.255
Tc = 5.46 min., by Equa6on 3-2 of Guidelines
Time Time Inc. Intens. Q Devel. Vol.ln Vol.Out Storage
0 ft. Gutter flow (min) (sec) (iNhr) (cfs) (cu ft) (cu ft) (cu fl)
-
-
Z1= 50.0 For Z2 5,46 328 3.06 0.78 343 0 343
Z2 = 3.5 Type B =1,0
n= 0.016 Rolled = 3.5 5 300 3.18 0.81 326 0 326
S= 0.005 10 600 2.24 0.57 406 0 406
15 900 1.77 0.45 457 0 457
d= 0.156 ft. 20 1200 1.45 0.37 485 0 485
25 1500 1.21 0.31 497 0 497
A R Q Tc Tc total I Qc 30 1800 1.04 0.27 507 0 507
- = 35 2100 0.91 0.23 513 0 513
0.65 0.08 0.76 0.00 5.46 3.06 0.78 40 2400 0.82 0.21 525 0 525
45 2700 0.74 0.19 531 0 531
Qpeak for Case 1= 0.78 cfs 50 3000 0.68 0.17 540 0 540
55 3300 0.64 0.16 557 0 557
60 3600 0.61 0.16 577 0 577
CASE 2 65 3900 0.60 0.15 614 0 614
70 4200 0.58 0,15 638 0 638
Case 2 assumes a Time of ConcenVation less than 5 minutes so that the 75 4500 0.56 0,14 659 0 659
peak flow =.90(3.18)(Imp. Area) = 0.00 cfs 80 4800 0.53 0,14 664 0 664
85 5100 0.52 0.13 691 0 691
90 5400 0.50 0.13 703 0 703
So, the Peak flow for the Basin is the greater of the two flows, 95 5700 0.49 0.12 726 0 726
0.78 cfs 100 6000 0.48 0.12 748 0 748
208' DRAINAGE POND CALCULATIONS
Required'208' Storage Volume
= Imperoious Area x.5 in I 12 iNft 0 cu ft
208' Storage Volume Provided cu fl
DRYWELL REQUIREMENTS -10 YEAR DESIGN STORM
Maximum Storage Required by Bowstring 691 cu ft
Number and Type of Drywells Required 0 Single
ERR Double
BOWSTRING METHOD PROJECT: Rivenvalk 9th Addition
PEAK FLOW CALCULATION PROJECT Riverwalk 9th Addition DETENTION BASIN OESIGN BASIN: Developed 0
BASIN: Developed 0 10-Year Design Stortn DESIGNER: S. Murphy
Tot. Area 0.85 Acres DATE: 09118
Imp. Area 0 SF
C = 0.15
Time Increment (min) 5
CASE 1 Time of Conc. (min) 5.46
Outflow (cfs) 0
100 ft. Overland Flow Design Year Flow 10
Area (acres) 0.85
Ct = 0.15 Impervious Area (sq ft) 0
L= 100 ft. 'C' Factor 0.15
n = 0.40 '208' Volume Provided
S= 0.010 Area' C 0,128
Tc = 5.46 min., by Equation 3-2 of Guidelines
Time Time Inc. Intens. Q Devel. Vol,ln Vol.Out Storage
0 ft. Gutter flow (min) (sec) (iNhr) (cfs) (cu ft) (cu ft) (cu ft)
Z1 = 50.0 For Z2 5.46 328 3.06 0.39 171 0 171
Z2 = 3.5 Type B =1.0
n= 0.016 Rolled = 3.5 5 300 3.18 0.41 1630 163
S= 0.005 10 600 2.24 0.29 203 0 203
15 900 1.77 0.23 228 0 228
d= 0.120 ft. 20 1200 1.45 0.18 242 0 242
25 1500 1.21 0.15 249 0 249
A R Q Tc Tc total I Qc 30 1800 1.04 0.13 253 0 253
35 2100 0.91 0.12 257 0 257
0.39 0.06 0.39 0.00 5.46 3.06 0.39 40 2400 0.82 0.10 263 0 263
45 2700 0.74 0.09 265 0 265
Qpeak for Case 1= 0.39 cfs 50 3000 0.68 0.09 270 0 270
55 3300 0.64 0.08 278 0 278
60 3600 0.61 0.08 289 0 289
CASE 2 65 3900 0.60 0.08 307 0 307
70 4200 0.58 0.07 319 0 319
Case 2 assumes a Time of Concentration less than 5 minutes so that the 75 4504 0.56 0.07 329 0 329
peak flow =.90(3.18)(Imp. Area) = 0.00 cfs 60 4800 0.53 0.07 332 0 332
85 5100 0.52 0.07 346 0 346
90 5400 0.50 0,06 351 0 351
So, the Peak flow for the Basin is the greater of the two flows, 95 5700 0.49 0.06 363 0 363
0.39 cfs 100 6000 0.48 0.06 374 0 374
208' DRAINAGE POND CALCULATIONS
Required'208' Storage Volume
= Impervious Area x.5 in 112 inlft 0 cu ft
208' Storage Volume Provided cu ft
DRYWELL REQUIREMENTS • 10 YEAR DESIGN STORM
Maximum Storage Required by Bowstring 346 cu ft
Number and Type of Drywells Required 0 Single
ERR Double
BOWSTRING METHOD PROJECT: Riverwalk 9th Addition
PEAK FLOW CALCULATION PROJECT Riverwalk 9th Addition DETENTION BASIN DESIGN BASIN: P
BASIN: P 10-Year Design Storm DESIGNER: S. Murphy
Tot. Area 0.31 Acres DATE: 03/23
Imp. Area 6502 SF
C = 0.59
Time Increment (min) 5
CASE 1 Time of Conc. (min) 5.00
Outflow (cfs) 0.3
45 ft. Overland Flow Design Year Flow 10
Area (acres) 0.31
Ct = 0.15 Impenrious Area (sq ft) 6502
L= 45 ft. 'C Factor 0.59
n= 0.16 '208' Volume Pravided 271
S= 0.020 Area + C 0.183
Tc = 1.59 min., by Equation 3-2 of Guidelines
Time Time Inc. Intens, Q Devel. Vol.ln Vol.Out Storage
120 ft. Gutter flow (min) (sec) (inlhr) (cfs) (cu ft) (cu ft) (cu ft)
Z1= 50.0 For Z2 5.00 300 3.18 0.58 234 90 144
Z2 = 1 Type B =1.0
n= 0.016 Rolled = 3.5 5 300 3.18 0.58 234 90 144
S= 0.008 10 600 2.24 0.41 288 180 108
15 900 1.77 0.32 324 270 54
d= 0.130 ft. 20 1200 1.45 0,27 345 360 -15
25 1500 1.21 0.22 355 450 -95
A R Q Tc Tc total I Qc 30 1800 1.04 0.19 362 540 -178
35 2100 0.91 0.17 366 630 -264
0.43 0.06 0.58 , 1.49 5.00 3.18 0.58 40 2400 0.82 0.15 375 720 -345
45 2700 0.74 0.14 379 810 -431
Qpeak for Case 1= 0,58 cfs 50 3000 0.68 0.12 386 900 -514
55 3300 0.64 0.12 398 990 -592
60 3600 0.61 0.11 413 1080 -667
CASE 2 65 3900 0.60 0.11 439 1170 -731
10 4200 0.58 0.11 456 1260 -804
Case 2 assumes a Time of Concentration less than 5 minutes so that the 75 4500 0.56 0.10 471 1350 -879
peak flow =.90(3.18)(Imp. Area) = 0.43 cfs 80 4840 0.53 0.10 475 1440 -965
85 5100 0.52 0.10 495 1530 -1035
90 5400 0.50 0.09 503 1620 -1117
So, the Peak flow for the Basin is the greater of the two flows, 95 5700 0,49 0.09 520 1110 •1190
0.58 cfs 100 6000 0.48 0.09 536 1800 -1264
208' DRAINAGE POND CALCULATIONS
Required'208' Storage Volume
= Impervious Area x.5 in I 12 inlft 271 cu R
208' Storage Volume Provided 271 cu ft
DRYWELL REQUIREMENTS -10 YEAR DESIGN STORM
Maximum Slorage Required by Bowstring 144 cu ft
Number and Type of Drywells Required 1 Single
0 Double
50-year STORM BOWSTRING METHOD PROJECT: Riverwalk 9th Addition
PEAK FLOW CALCULATION PROJECT Rivenvalk 9th Addition DETENTION BASIN DESIGN BASIN: A
BASIN: A DESIGNER: S. Murphy
Tot. Area 1.12 Aaes DATE: 09121
Imp, Area 10748 SF
C = 0.32
Time Inc,rement (min) 5
CASE 1 Time of Conc, (min) 6.81
Outflow (cfs) 1
120 ft. Overiand Flow Design Year Flow 50
Area (acxes) 1.12
Ct = 0.15 Impervious Area (sq ft) 10748
L= 120 ft. 'C' Factor 0.32
n= 0.40 50-year Volume Provided 573.5
S= 0.020 Area' C 0.358
Tc = 4.95 min., by Equafion 3-2 of Guidelines
Time Time Inc. Intens. Q Devel. Vol.ln Vol.Out Staage
202 ft. Gutter flow (min) (sec) (iNhr) (cfa) (cu ft) (cu ft) (cu ft)
Z1= 50.0 6.81 409 3.95 1.42 776 409 368
72 = 3.5
n= 0.016 5 300 4.58 1.64 660 300 360
S= 0.010 10 600 3.20 1.15 847 600 247
15 900 2.45 0.88 912 900 12
d= 0.172 ft. 20 1200 1.95 0.70 936 1200 -264
25 1500 1.62 0.58 952 1500 -548
A R Q Tc Tc total I Qc 30 1800 1.56 0.56 1084 1800 -716
35 2100 1.28 0.46 1027 2100 -1073
0.79 0.09 1.42 1.86 6.81 3.95 1.42 40 2400 1.19 0.42 1078 2400 -1322
45 2700 1.08 0.39 1099 2700 -1601
Qpeak for Case 1= 1.42 cfs 50 3000 0.99 0.35 1114 3000 -1886
55 3300 0.92 0.33 1134 3300 -2166
60 3600 0.87 0.31 1166 3600 -2434
CASE 2 65 3900 0.82 0.29 1187 3900 -2713
70 4200 0.80 0.29 1244 4200 -2956
Case 2 assumes a Time of Concentration less than 5 minutes so that the 75 4500 0.77 0.28 1280 4500 -3220
peak flow =.90(4.58)(Imp. Area) = 1.02 cfs 80 4800 0.75 0.27 1328 4800 -3472
85 5100 0.72 0.26 1352 5100 -3748
90 5400 0.71 0.25 1409 5400 -3991
So, the Peak flaw for the Basin is the greater of the two flows, 95 5700 0.69 0,25 1444 5700 -4256
1.42 cfs 100 6000 0.67 0.24 1474 6000 4526
208' DRAINAGE POND CALCULATIONS
Required'208' Storage Volume
= Impervious Area x.5 in 112 inlft 448 cu ft
'208' Volume Provided 573.5 cu ft
DRYWELL REQUIREMENTS - 50 YEAR DESIGN STORM
Maximum Slorage Required by Bowstring 368 cu ft
Number and Type of Drywells Required 0 Single
1 Double
INLAND PACIFIC ENGINEERING
50-year STORM BOWSTRING METHOD PROJECT: Riverwalk 9th Addition
PEAK FLOW CALCULATION PROJECT Riverwalk 9th Addition DETENTION BASIN DESIGN BASIN: B
BASIN: B DESIGNER: S. Murqhy
Tot. Area 0.39 Acres DATE: 09115
Imp.Area 4598 SF
C = 0,36
Time Increment (min) 5
CASE 1 Time of Conc. (min) 6.30
Outflow (cfs) 0.3
65 fl, Overland Flow Design Year Flow 50
Area (aaes) 0.39
C1= 0.15 Impenrious Area (sq ft) 4598
L= 65 fl. 'C' Fador 0.36
n= 0.40 50-year Volume Provided 211
S= 0.020 Area' C 0.140
Tc = 3.43 min., by Equation 3-2 of Guidelines
Time Time Inc. Intens. Q Devel. Vol.ln Vol.Out Storage
249 fl. Gutter flow (min) (sec) (iNhr) (cfs) (cu ft) (cu fl) (cu ft)
Z1= 50.0 6.30 378 4.13 0.58 294 113 180
Z2 = 3.5
n= 0.016 5 300 4.58 0.64 258 90 168
S= 0.010 10 600 3.20 0.45 327 180 147
15 904 2,45 0.34 354 270 84
d= 0.123 ft. 20 1200 1.95 0.27 364 360 4
25 1500 1.62 0.23 370 450 -80
A R Q Tc Tc total I Qc 30 1800 1.56 0.22 422 540 -118
- 35 2100 1.28 0.18 400 630 -230
-
0.40 0.06 0.58 2.87 6.30 4.13 0.58 40 2400 1.19 0.17 421 720 -299
45 2700 1,08 0.15 429 810 -381
Qpeak for Case 1= 0.58 cfs 50 3000 0.99 0.14 435 900 -465
55 3300 0.92 0.13 443 990 -547
60 3600 0.87 0,12 455 1080 -625
CASE 2 65 3900 0.82 0.12 464 1170 -706
70 4200 0.80 0.11 486 1260 -774
Case 2 assumes a Time of Concentration less than 5 minutes so that lhe 75 4500 0.77 0.11 500 1350 -850
peak flow =.90(4.58)(Imp. Area) = 0.44 cfs 80 4800 0.75 0.11 519 1440 -921
85 5100 0.72 0.10 529 1530 -1001
90 5400 0.71 0.10 551 1620 -1069
So, the Peak flow for the Basin is the greater of lhe two flows, 95 5700 0.69 0.10 565 1710 -1145
0.58 cfs 100 6000 0,67 0.09 576 1800 -1224
208' DRAINAGE PQND CALCULATIONS
Required'208' Storage Volume
= Impervious Area x.5 in I 12 iNft 192 cu ft
50 year Volume Provided 187.5 cu ft
DRYWELL REQUIREMENTS - 50 YEAR DESIGN STORM
Maximum Storage Required by Bowstring 180 cu fl
R Number and Type of Drywells Required 1 Single
0 Double
INLAND PACIFIC ENGINEERING
50-year STORM BOWSTRING METHOD PROJECT: Riverwalk 9th Addition
PEAK FLOW CALCULATION PROJECT Riverwalk 9th Addition DETENTION BASIN OESIGN BASIN: C
BASIN C DESIGNER: S. Murphy
Tot. Area 1.48 Acres DATE: 09l15
Imp. Area 11380 SF
C = 0,28
Time Increment (min) 5
CASE 1 Time of Conc, (min) 6.51
Outflow (cfs) 1
50 ft. Overland Flow Design Year Flow 50
Area (aaes) 1.48
Ct = 0.15 Impervious Area (sq ft) 11380
L= 50 ft. 'C' Faclor 0.28
n= 0.40 50-year Volume Provided 496
S= 0.020 Area ' C 0.414
Tc = 2.93 min., by Equation 3-2 of Guidelines
Time Time Inc. Intens. Q Devel. Vol.ln Vol.Out Starage
447 ft. Gutter flow (min) (sec) (inmr) (cfs) (cu ft) (cu fl) (cu ft)
- -
Z1= 50.0 6.51 391 4.06 1.68 680 391 490
Z2 = 3.5
n= 0.016 5 300 4.58 1.90 763 300 463
S= 0.013 10 600 3.20 1.33 972 600 372
15 900 2.45 1.02 1049 900 149
d= 0.174 R. 20 1200 1.95 0.81 1077 1200 -123
25 1500 1.62 0.67 1096 1500 -404
A R Q Tc Tc lotal I Qc 30 1800 1.56 0.65 1249 1800 -551
35 2100 1.28 0.53 1184 2100 -916
- - - -
0.81 0.09 1.68 3.58 6.51 4.06 1.68 40 2400 1.19 0.49 1244 2400 -1156
45 2700 1.08 0.45 1268 2700 -1432
Qpeak for Case 1= 1.68 cfs 50 3040 0.99 0.41 1285 3000 -1715
55 3300 0.92 0.38 1309 3300 -1991
60 3600 0.87 0.36 1346 3600 -2254
CASE 2 65 3900 0.82 0.34 1370 3900 -2530
70 4200 0,80 0.33 1436 4200 -2764
Case 2 assumes a Time of Concentration less than 5 minutes so thal the 75 4500 0.77 0.32 1478 4500 -3022
peak flow =.90(4.58)(Imp. Area) = 1.08 cfs 80 4800 0.75 0,31 1533 4600 -3267
85 5100 0.72 0.30 1561 5100 -3539
90 5400 0.71 0.29 1628 5400 -3772
So, the Peak flow for the Basin is the greater of the two flows, 95 5700 0.69 0.29 1668 5700 -4032
1.68 cfs 100 6000 0.67 0.28 1703 6000 -4297
208' DRAINAGE POND CALCULATIONS
Required'208' Storage Volume
= Impervious Area x.5 in 112 iNft 474 cu fl
50 year Volume Provided 496 cu fl
DRYWELL REQUIREMENTS - 50 YEAR DESIGN STOR
Maximum Storage Required by Bowstring 490 cu ft
Number and Type of Drywells Required 0 Single
~ 1 Double
INLAND PACIFIC ENGINEERING
50-year STORM BOWSTRING METHOD PROJECT: Riverwalk 9th AddKion
PEAK FLOW CALCUlATION PROJECT Riverwalk 9th Addition DETENTION BASIN DESIGN BASIN: D
BASIN: D DESIGNER: S. Murphy
Tot. Area 0.75 Acres DATE: 09115
Imp. Area 6174 SF
C = 0,29
Time Increment (min) 5
CASE 1 Time of Conc. (min) 6,70
Outflow (cfs) 0,3
120 ft. Overland Flow Design Year Flow 50
Area (aaes) 0.75
Ct = 0.15 Impervious Area (sq ft) 6174
L= 120 ft. 'C' Factor 0,29
n= 0.40 50-year Volume Provided 262
S= 0.020 Area' C 0.217
Tc = 4.95 min., by Equation 3-2 of Guidelines
Time Time Inc. Iniens. Q Devel. Vol.ln Val.Out Storage
200 ft. Gutter flow (min) (sec) (inlf►r) (cfs) (cu ft) (cu R) (cu ft)
Z1= 50.0 ' 6.70 402 3.99 0.87 468 121 341
Z2 = 3.5
n= 0.016 5 300 4.58 1.00 400 90 310
S= 0.016 10 600 3.20 0.70 513 180 333
15 900 2.45 0.53 552 270 282
d= 0.131 ft. 20 1200 1.95 0.42 567 360 201
25 1500 1.62 0.35 577 450 127
A R Q Tc Tc total I Qc 30 1840 1.56 0.34 657 540 117
- - 35 2100 128 0.28 623 630 -7
0.46 0.07 0.87 1.75 6.70 3.99 0.87 40 2400 1.19 0.26 654 720 -66
45 2700 1.08 0.23 666 810 -144
Qpeak for Case 1= 0.87 cfs 50 3000 0.99 0.22 675 900 -225
55 3300 0.92 0.20 688 990 -302
60 3600 0.87 0.19 707 1080 -373
CASE 2 65 3900 0.82 0.18. 720 1170 -450
70 4200 0.80 0.17 755 1260 -505
Case 2 assumes a Time of Concentration less than 5 minutes so that the 75 4500 0.77 0.17 777 1350 -573
peak flow =.90(4.58)(Imp. Area) = 0.58 efs 80 4800 0.75 0.16 805 1440 -635
85 5100 0.72 0.16 820 1530 -710
90 5400 0.71 0.15 855 1620 •765
So, the Peak flow for the Basin is the greater of the two Bows, 95 5700 0.69 0.15 876 1710 -834
0.87 cfs 100 6000 0,67 0.15 894 1800 -906
208' DRAINAGE POND CALCULATIONS
Required'208' Storage Volume
= Impervious Area x.5 in / 12 iNft 257 cu ft
50 year Volume Provided 262 cu ft
DRYWELL REQUIREMENTS - 50 YEAR DESIGN STORM
Maximum Storage Required by Bowstring 347 cu ft
Number and Type of Drywells Required 1 Single
0 Double
INLANO PACIFIC ENGINEERING
50-year STORM BOWSTRING METHOD PROJECT: Riverwalk 9th Addition
PEAK FLOW CALCULATION PROJECT Riverwalk 9th Addition DETENTION BASIN DESIGN BASIN: E
BASIN: E DESIGNER: S. Murphy
Tot. Area 0.64 Acres DATE: 03/23
Imp. Area 11277 SF
C = 0.45
Time Increment (min) 5
CASE 1 Time of Conc. (min) 5.00
Outflow (cfs) 0.3
17 ft. Overland Flow Design Year Flow 50
Area (acres) 0.64
Ct = 0.15 Impervious Area (sq ft) 11277
L= 17 ft. 'C' Factor 0.45
n= 0.02 50-year Volume Provided 487.5
S= 0.020 Area ' C 0.288
Tc = 0.25 min., by Equation 3-2 of Guidelines
Time Time Inc. Intens. Q Devel. Vol.ln Vol.Out' Storage
135 ft. Gutter flow (min) (sec) (in/hr) (cfs) (cu ft) (cu ft) (cu ft)
Z1 = 50.0 5,00 300 4.58 1.32 530 90 440
Z2 = 3.5
n= 0,016 5 300 4.56 1.32 530 90 440
S= 0.010 10 600 3.20 0.92 647 180 467
15 940 2.45 0.71 707 270 437
d= 0.167 ft. 20 1200 1.95 0.56 731 360 371
25 1500 1.62 0.47 747 450 297
A R Q Tc Tc total I Qc 30 1800 1.56 0.45 855 540 315
- -
- 35 2100 1,28 0.31 812 630 182
0.75 0.08 1.32 1.27 5.00 4.58 1.32 40 2400 1.19 0.34 854 720 134
45 2700 1.08 0.31 872 810 62
Qpeak for Case 1= 1.32 cfs 50 3000 0.99 0.29 884 900 -16
55 3300 0.92 0.26 901 990 -89
60 3600 0.87 0.25 928 1080 -152
CASE 2 65 3900 0.82 0,24 945 1170 -225
70 4200 0.80 0.23 991 1260 -269
Case 2 assumes a Time of Concentration less than 5 minutes so that the 75 4500 0,77 0.22 1021 1350 -329
peak flow =.90(4.58)(Imp. Area) = 1.07 cfs 80 4800 0.75 0.22 1059 1440 -381
85 5100 0.72 0.21 1079 1530 -451
90 5400 0.71 0.20 1125 1620 -495
So, the Peak flow for the Basin is the greater of the two flows, 95 5100 0.69 0.20 1153 1710 -557
1.32 cfs 100 6000 0.67 0.19 1177 1800 -623
208' ORAINAGE POND CALCULATIONS
Required'208' Storage Volume
= Impervious Area x.5 in / 12 inlft 470 cu ft
50 year Volume Provided 487.5 cu ft
DRYWELL REQUIREMENTS - 54 YEAR DESIGN STORM
Maximum Storage Required by Bowstring 467 cu ft
Number and Type of Drywells Required 1 Single
0 Double
INLAND PACIFIC ENGINEERING
50-year STORM BOWSTRING METHOD PROJECT: Riverwalk 9th Addition
PEAK FLOW CALCULATION PROJECT Riverwalk 9th Addition DETENTION BASIN DESIGN BASIN: F
BASIN; F DESIGNER: S. Murphy
Tot. Area 0.57 Acres DATE: 09115
Imp. Area 5161 SF
C = 0.31
Time Increment (min) 5
CASE 1 Time of Conc. (min) 5.83
Outflow (cfs) 0.3
100 fl. Overland Flow Design Year Flow 50
Area (acres) 0.57
Ct = 0.15 Impervious Area (sq ft) 5161
L= 100 ft. 'C' Factor 0.31
n= 0.40 50-year Volume Provided 223.5
S= 0,020 Area • C 0.177
Tc = 4.44 min., by Equation 3-2 af Guidelines
Time Time Inc. Intens. Q Devel. Vol,in Vol.Out Storage
146 ft. Gutter flow (min) (sec) (iNhr) (cfs) (cu ft) (cu fl) (cu ft)
Z1= 50.0 5.83 350 4.29 0.76 356 105 251
Z2 = 3.5
n= 0.016 5 300 4.58 0.81 325 90 235
S= 0.014 10 600 3.20 0.57 406 180 226
15 900 2.45 0.43 441 270 171
d= 0.127 fl. 20 1200 1.95 0.34 454 360 94
25 1500 1.62 0.29 463 450 13
A R Q Tc Tc toial I Qc 30 1800 1.56 0.28 529 540 -11
- 35 2100 1.28 0.23 502 630 -128
0.43 0.06 0.76 1.39 5.83 4.29 0.76 40 2400 1.19 0.21 527 720 -193
45 2700 1.08 0.19 538 810 -272
Qpeak for Case 1= 0.76 cfs 50 3000 0.99 0.17 546 900 -354
55 3300 0.92 0.16 556 990 -434
60 3604 0.87 0.15 572 1080 -508
CASE 2 65 3900 0.82 0.14 582 1170 -588
70 4200 0.80 0.14 611 1260 -649
Case 2 assumes a Time of Concentration less than 5 minuies so that the 75 4500 0.77 0.14 628 1350 -722
peak flow =.90(4.58)(Imp. Area) = 0.49 cfs 80 4800 0.75 0.13 652 1440 -788
85 5100 0.72 0.13 664 1530 -866
90 5400 0.71 0.13 692 1620 -928
So, lhe Peak flow for the Basin is the greater of the two flows, 95 5700 0.69 0.12 709 1710 -1001
0.76 cfs 100 6000 0.67 0.12 724 1800 -1076
208'nRaiNAGE POND CALCULATIONS
Required'206' Storage Volume
~ = Impervious Area x.5 in I 12 inlft 215 cu ft
50 year Volume Provided 223.5 cu fl
DRYWELL REQUIREMENTS • 50 YEAR DESIGN STORM
Maximum Storage Required by Bowstring 251 cu ft
Number and Type of Drywells Required 1 Single
0 Double
IN;AND PACIFIC ENGINEERING
50-year STORM BOWSTRING METHOD PROJECT: Riverwalk 9th Addition
PEAK FLOW CALCULATION PROJECT Riverwalk 9th Addition DETENTION BASIN DESIGN BASIN: G
BASIN: G OESIGNER: S. Murphy
Tot. Area 0.63 Acres DATE: 09115
Imp. Area 6092 SF
C = 0.32
Time Inaement (min) 5
CASE 1 Time of Conc. (min) 5.00
Outflow (cfs) 0.3
50 ft. Overland Flow Design Year Flaw 50
Area (aaes) 0.63
Ct = 0.15 Imperoious Area (sq ft) 6092
L= 50 ft. 'C' Factor 0.32
n= 0.40 50-year Volume Provided 296.5
S= 0.020 Area • C 0.202
Tc = 2.93 min., by Equation 3-2 of Guidelines
Time Time Inc, Intens. Q Devel. Vol.ln Vol.Out Storage
210 ft. Gutter flow (min) (sec) (infir) (cfs) (cu ft) (cu ft) (cu ft)
Z1 = 50.0 5.00 300 4.58 0.92 371 90 281
Z2 = 3.5
n= 0.016 5 300 4.58 0.92 371 90 281
S= 0.016 10 600 3.20 0.65 453 180 273
15 900 2.45 0.49 495 270 125
d= 0,221 ft. 20 1200 1.95 0.39 512 360 152
25 1500 1.62 0.33 523 450 73
A R Q Tc Tc total I Qc 30 1800 1.56 0.31 598 540 58
35 2100 1.28 0.26 568 630 -62
1.34 0.11 3.52 1.29 5.00 4,58 0.92 40 2400 1.19 0.24 598 720 -122
45 2700 1.08 0.22 610 810 -200
Qpeak for Case 1= 0.92 cfs 50 3000 0.99 0.20 619 900 -281
55 3300 0.92 0.19 631 990 -359
60 3600 0.87 0.18 649 1080 -431
CASE 2 65 3900 0,82 0.17 662 1170 -508
70 4200 0.80 0.16 694 1260 -566
Case 2 assumes a Time of Concentration less than 5 minutes so that the 75 4500 0.77 0.16 714 1350 -636
peak flow =.90(4.58)(Imp. Area) = 0.58 cfs 80 4800 0.75 0.15 741 1440 -699
85 5100 0.72 0.15 755 1530 -775
90 5400 0.71 0.14 788 1620 -832
So, the Peak flow for the Basin is the greater of the two flows, 95 5700 0.69 0.14 807 1710 -903
0.92 cfs 100 6000 0.67 0.14 824 1800 -976
208' DRAINAGE POND CALCULATIONS
Required '208' Slorage Volume
= Impervious Area x.5 in ! 12 iNft 254 cu ft
50 year Volume Provided 296.5 cu ft
DRYWELL REQUIREMENTS - 50 YEAR DESIGN STORM
Maximum Storage Required by Bowstring 281 cu ft
Number and Type of Drywells Required 1 Single
0 Double
INLAND PACIFIC ENGINEERING
50-year STORM BOWSTRING METHOD PROJECT: Riven+ralk 9th Addition
PEAK FLOW CALCULATION PROJECT Riverwalk 9th Addition DETENTION BASIN DESIGN BASIN: H
BASIN: H DESIGNER: S. Murphy
Tot. Area 0.07 Aaes DATE: 09l15
Imp. Area 3188 SF
C = 0.90
Time Increment (min) 5
CASE 1 Time of Conc. (min) 5.04
Outflow (ds) 0
40 ft. Overland Flow Design Year Flow 50
Area (acres) 0.01
Ct = 0.15 Impervious Area (sq ft) 3188
L= 40 ft. 'C' Factor 0,9
n= 0.40 50-year Volume Provided 136
S= 0.020 Area' C 0.063
Tc = 2.56 min., by Equation 3-2 of Guidelines
Time Time Inc. Intens. Q Devel, Vol.ln Vol.Oul Storage
143 ft Gutter flow (min) (sec) (iNhr) (cfs) (cu ft) (cu ft) (cu ft)
Z1= 50.0 5.00 300 4.58 0.29 116 0 116
Z2 = 3.5
n= 0.016 5 300 4.58 0.29 116 0 116
S= 0.011 10 600 3.20 0.20 142 0 142
15 900 2.45 0.15 155 0 155
d= 0.093 ft. 20 1200 1.95 0.12 160 0 160
25 1500 1.62 0.10 164 0 164
A R Q Tc Tc total I Qc 30 1800 1.56 0.10 187 0 187
35 2100 1.28 0.08 178 0 178
0.23 0.05 0.29 1.89 5.00 4.58 0.29 40 2400 1.19 0.07 187 0 167
45 2700 1.08 0.07 191 0 191
Qpeak for Case 1= 0.29 cfs 50 3000 0.99 0.06 193 0 193
55 3300 0.92 0.06 197 0 197
60 3600 0.87 0.05 203 0 203
CASE 2 65 3900 0.82 0.05 207 0 207
70 4200 0.80 0.05 217 0 217
Case 2 assumes a Time of Concentration less ihan 5 minutes so that the 15 4500 0.77 0.05 223 0 223
peak flow =.90(4.58)(Imp. Area) = 0.30 cfs 80 4800 0.75 0.05 232 0 232
85 5100 0.72 0.05 236 0 236
90 5400 0.71 0,04 246 0 246
So, the Peak flow for the Basin is the greater of the two flows, 95 5700 0.69 0.04 252 0 252
0.30 cfs 100 6000 0.67 0.04 258 0 258
208' DRAINAGE POND CALCULATIONS
Required '208' Storage Volume
= Impervious Area x.5 in I 12 inlfl 133 cu ft
50 year Volume Provided 136 cu ft
DRYWELL REQUIREMENTS -10 YEAR DESIGN STOR
Maximum Storage Required by Bowstring 236 cu ft
Number and Type of Drywells Required 0 Single
ERR Double
INLAND PACIFIC ENGINEERING
50-year STORM BOWSTRING METHOD PROJECT: Riverwalk 9th Addition
PEAK FLOW CALCULATION PROJECT Riverwalk 9th Addition DETENTION BASIN DESIGN BASIN: I
BASIN: I DESIGNER: S. Murphy
Tot. Area 0.46 Acres DATE: 09115
Imp. Area 5412 SF
C = 0.36
Time Inaement (min) 5
CASE 1 Time af Conc. (min) 5.00
Outflow (cis) 0.3
40 ft. Overland Flow Design Year Flow 50
Area (aaes) 0.46
Ct = 0.15 Impervious Area (sq ft) 5472
L= 40 ft. 'C' Fador 0.36
n= 0.40 50-year Volume Provided 231 ~
S= 0.020 No8 f C 0.16
Tc = 2.56 min., by Equation 3-2 of Guidelines
Time Time Inc. Intens. Q Devel. Vol.ln Vol.Out Storage
143 ft. Gutter flow (min) (sec) (infir) (cfs) (cu ft) (cu ft) (cu ft)
-
-
Z1= 50.0 5.00 300 4.58 0.76 305 90 215
Z2 = 3.5
n= 0.016 5 300 4.58 0.76 305 90 215
S= 0.011 10 600 3.20 0.53 372 180 192
15 900 2.45 0.41 407 270 137
d= 0.133 ft. 20 1200 1.95 0.32 420 360 60
25 1500 1.62 0.27 430 450 -20
A R Q Tc Tc total I Qc 30 1800 1.56 0.26 491 540 -49
35 2100 1.28 0.21 467 630 -163
0.47 0.07 0.76 1.49 5.00 4.58 0.76 40 2400 1.19 0.20 491 720 -229
45 2700 1.08 0.18 501 810 -309
Qpeak for Case 1= 0J6 cfs 50 3000 0.99 0.16 509 900 -391
55 3300 0.92 0.15 518 990 -472
60 3600 0.81 0.14 533 1080 -547
CASE 2 65 3900 0.82 0.14 543 1170 -627
70 4200 0.80 0.13 570 1260 -690
Case 2 assumes a Time of Concentration less than 5 minutes so that the 75 4500 0.77 0.13 581 1350 -763
peak flow =.90(4.58)(Imp. Area) = 0.52 cfs 80 4800 0.75 0.12 609 1440 -831
85 5100 0.72 0.12 620 1530 -910
90 5400 0.71 0.12 647 1610 -973
So, the Peak flow for Ihe Basin is the greater of the two flows, 95 5700 0.69 0.11 663 1710 -1047
0.76 cfs 100 6000 0.67 0.11 677 1800 -1123
208' DRAINAGE POND CALCULATIONS
Required'208' Storage Volume
= Impenrious Area x,5 in I 12 iNft 228 cu ft
50 year Volume Provided 231 cu ft
DRYYYELL REQUIREMENTS -10 YEAR DESIGN STOR
Maximum Storage Required by Bowstring 215 cu ft
Number and Type of Drywells Required 1 Single
0 Double
INLAND PACIFIC ENGINEERING
50-year STORM BOWSTRING METHOD PROJECT: Riveneralk 9lh Addiiion
PEAK FLOW CALCULATION PROJECT Riverwalk 9th Addition DETENTION BASIN DESIGN BASIN: J
BASIN: J DESIGNER: S. Murphy
Tot. Area 0.92 Acres DATE: 09115
Imp. Area 5998 SF
C = 0.14
Time Increment (min) 5
CASE 1 Time of Conc. (min) 6.49
Outflow (cfs) 0.3
50 ft. Overland Flow Design Year Flow 50
Area (acres) 0.92
Ct = 0.15 Impenrious Area (sq ft) 5998
L= 50 ft. 'C' Fador 0,14
n= 0.40 50-year Volume Provided 274.5
S= 0.020 Area' C 0.129
Tc = 2.93 min., by Equation 3-2 of Guidelines
Time Time Inc. Intens. Q Devel, Vol.ln Vol.Out Storage
311 ft. Gutter flow (min) (sec) (iNhr) (cfs) (cu ft) (cu ft) (cu fl)
Z1= 50.0 6.49 389 4.07 0.52 273 117 156
Z2 = 3.5
n= 0.016 5 300 4.58 0.59 237 90 147
S= 0.011 10 600 3.20 0.41 302 180 122
15 900 2.45 0.32 326 270 56
d= 0.116 ft. 20 1200 1.95 0.25 335 360 -25
25 1500 1.62 0.21 341 450 -109
A R Q Tc Tc total I Qc 30 1800 1.56 0.20 388 540 -152
35 2100 1.28 0.16 366 630 -262
-
0.36 0.06 0.52 3.56 6.49 4.07 0.52 40 2400 1.19 0.15 387 720 -333
45 2700 1.08 0.14 394 810 -416
Qpeak for Case 1= 0.52 cfs 50 3000 0.99 0.13 399 900 -501
55 3300 0.92 0.12 407 990 -583
60 3600 0.87 0.11 418 1060 -662
CASE 2 65 3900 0.82 0.11 426 1170 -744
70 4200 0.80 0.10 446 1260 -814
Case 2 assumes a Time of Concentration less than 5 minutes so that the 75 4500 0.77 0.10 459 1350 -891
peak flow = 90(4.58)(Imp. Area) = 0.57 cfs 80 4800 0.75 0.10 476 1440 -964
85 5100 0.12 0.09 485 1530 -1045
90 5400 0.71 0.09 506 1620 -1114
So, the Peak flow for the Basin is the greater o( the two 8ows, 95 5700 0.69 0.09 518 1710 -1192
0.57 cfs 100 6000 0.67 0.09 529 1800 -1271
208' DRAINAGE POND CALCULATIONS
Required '208' Storage Volume
= Impervious Area x.5 in I 12 inlft 250 cu ft
50 year Volume Provided 274.5 cu ft
DRYWELL REQUIREMENTS -10 YEAR DESIGN STOR
Maximum Storage Required by Bowstring 156 cu ft
Number and Type oi Drywells Required 1 Single
0 Double
INLAND PACIFIC ENGINEERING
50-year STORM BOWSTRING METHOD PROJECT: Riverwalk 9th Addition
PEAK FLOW CALCULATION PROJECT Riverwalk 9th Addition DETENTION BASIN DESIGN BASIN: K
BASIN: K DESIGNER: S. Murphy
Tot. Area 0.09 Acres DATE: 09115
Imp. Area 3908 SF
C = 0.90
Time Inaement (min) 5
CASE 1 Time of Conc. (min) 5.00
Outflow (cfs) 0
50 ft. Overland Flow Design Year Flow 50
Area (aaes) 0.09
Ct = 0.15 Imperoious Area (sq ft) 3908
L= 50 ft. 'C' Factor 0.9
n= 0.40 '208' Volume Provided 185
S= 0.020 Area' C 0.081
Tc = 2.93 min., by Equation 3-2 of Guidelines
Time Time Inc. Intens. Q Devel, Vol.ln Vol.Out Storage
143 ft. Gutter flow (min) (sec) (iNhr) (cfs) (cu ft) (cu ft) (cu ft)
Z1 = 50.0 5.00 300 4.58 0.37 149 0 149
Z2 = 3.5
n= 0.016 5 300 4.58 0.31 149 0 149
S= 0.011 10 600 3.20 0.26 182 0 182
15 900 2.45 0,20 199 0 199
d= 0.102 ft. 20 1200 1.95 0.16 206 0 206
25 1500 1,62 0.13 210 0 210
A R Q Tc Tc total I Qc 30 1800 1.56 0.13 240 0 240
35 2100 1.28 0,10 226 0 228
0.28 0.05 0.37 1.78 5.00 4.58 0.37 40 2400 1.19 0.10 240 0 240
45 2700 1.08 0.09 245 0 245
Qpeak for Case 1= 0.37 cfs 50 3000 0.99 0.08 249 0 249
55 3300 0.92 0.07 254 0 254
60 3600 0.87 0.07 261 0 261
CASE 2 65 3900 0.82 0.07 266 0 266
70 4204 0.80 0.06 279 0 279
Case 2 assumes a Time of Concentration less than 5 minutes so that the 75 4500 0.77 0.06 287 0 287
peak flow =.90(4.58)(Imp. Area) = 0.37 cfs 80 4800 0.75 0.06 298 0 298
85 5100 0.72 0.06 303 0 303
90 5400 0.71 0.06 316 0 316
So, the Peak flow for the Basin is lhe greater oi the two flows, 95 5700 0.69 0,06 324 0 324
0.37 cfs 100 6000 0.67 0.05 331 0 331
208' DRAINAGE POND CALCULATIONS
Required'208' Storage Volume
= Impervious Area x,5 in ! 12 inlft 163 cu ft
50 year Volume Provided 185 cu ft
ORYWELL REQUIREMENTS -10 YEAR DESIGN STOR
Maximum Storage Required by Bowstring 303 cu ft
Number and Type of Drywells Required 0 Single
ERR Double
INLAND PACIFIC ENGINEERING
50-year STORM BOWSTRING METHOD PROJECT: Riverwalk 9th Addition
PEAK FLOW CALCULATION PROJECT Rivervvalk 9th Addition DETENTION BASIN DESIGN BASIN: HI & JK
BASIN; HI & JK DESIGNER: S. Murphy
Tot. Area 1,38 Acres DATE: 09118
Imp. Area 11470 SF
C = 0.29
Time Inaement (min) 5
CASE 1 Time af Conc. (min) 5.02
OuHlow (cfs) 1
50 R. Overland Flow Design Year Flow 50
Area (aaes) 1.38
Ct = 0.15 Impervious Area (sq ft) 11470
L= 50 ft. 'C' Factor 0.29
n= 0,40 '208' Volume Provided 505.5
S= 0.020 Area' C 0,400
Tc = 2.93 min., by Equation 3-2 of Guidelines
Time Time Inc. Intens. Q Devel. Vol,ln Vol.Out Storage
250 ft. Gutter flow (min) (sec) (iNhr) (cfs) (cu ft) (cu ft) (cu ft)
Z1 = 50.0 5.02 301 4.57 1.83 738 301 437
Z2 = 3.5
n= 0.016 5 300 4.58 1,83 737 300 437
S= 0.011 10 600 3.20 1.28 899 600 299
15 900 2.45 0.98 983 900 83
d= 0.185 it. 20 1200 1.95 0.78 1016 1200 -184
25 1500 1.62 0.65 1039 1500 -461
A R Q Tc Tc lotal t Qc 30 1800 1.56 0.62 1188 1800 -612
- 35 2100 1.28 0.51 1128 2100 -972
0.92 0.09 1.83 2.09 5.02 4.57 1.83 40 2400 1,19 0.47 1187 2400 -1213
45 2700 1.08 0.43 1211 2700 -1489
Qpeak for Case 1= 1.83 cfs 50 3000 0.99 0.40 1229 3000 -1771
55 3300 0.92 0.37 1253 3300 -2047
60 3600 0.67 0.35 1289 3600 -2311
CASE 2 65 3900 0.82 0.33 1313 3900 -2587
70 4200 0.80 0.32 1377 4200 -2823
Case 2 assumes a Time oi Concentration less than 5 minutes so that the 75 4500 0.77 0.31 1416 4500 -3082
peak flow =.90(4.58)(Imp. Area) = 1.09 cfs 80 4800 0,75 0.30 1471 4800 -3329
85 5100 0,72 0.29 1499 5100 -3601
90 5400 0,71 0.28 1563 5400 -3837
So, the Peak flow for the Basin is the greater of the two flows, 95 5700 0.69 0,28 1602 5700 -4098
1.83 cfs 100 6000 0.67 027 1636 6000 -4364
208' DRAINAGE POND CALCULATIONS
Required'208' Storage Volume
= Impervious Area x.5 in I 12 iNft 478 cu ft
50 year Volume Provided 505.5 cu ft
DRYWELL REQUIREMENTS -10 YEAR DESIGN STOR
Maximum Storage Required by Bowstring 437 cu ft
Number and Type of Drywells Required 0 Single
1 Double
INLAND PACIFIC ENGINEERING
50-year STORM BOWSTRING METHOD PROJECT: Riverwalk 91h Addition
PEAK FLOW CALCULATION PROJECT Rivenhralk 9th Addition DETENTION BASIN DESIGN BASIN: P
BASIN: P DESIGNER: S. Murphy
Tot. Area 0.31 Acres DATE: 03123
Imp. Area 6502 SF
C = 0.59
Time Increment (min) 5
CASE 1 Time of Conc, (min) 5.00
Outflow (cfs) 0.3
45 ft. Overland Flow Design Year Flow 50
Area (acres) 0.31
Ct = 0.15 Impervious Area (sq ft) 6502
L= 45 ft. 'C Factor 0.59
n= 0.02 '208' Volume Provided 271
S= 0.020 Area ' C 0,183
Tc = 0.40 min., by Equation 3-2 of Guidelines
Time Time Inc. Intens. Q Devel. Vol.ln Vol.Out Storage
120 ft. Gutter flow (min) (sec) (in/hr) (cfs) (cu ft) (cu ft) (cu ft)
Z1 = 50.0 5.00 300 4.58 0.84 337 90 247
Z2 = 1
n= 0.016 5 300 4.58 0.84 337 90 247
S= 0.011 10 600 3.20 0.59 411 160 231
15 900 2.45 0.45 449 270 179
d= 0.141 ft. 20 1200 1,95 0.36 464 360 104
25 1540 1.62 0.30 475 450 25
A R Q Tc Tc total I Qc 30 1800 1.56 0.29 543 540 3
= - 35 2100 1.28 0.23 516 630 -114
-
0.51 0.07 0.84 1.21 5,00 4.58 0.64 40 2400 1.19 0,22 542 720 -178
45 2700 1.08 0.20 553 810 -257
Qpeak for Case 1= 0.84 cfs 50 3000 0.99 0.18 562 900 -338
55 3300 0.92 0.11 572 990 -418
60 3600 0.87 0.16 589 1080 -491
CASE 2 65 3900 0.82 0.15 600 1170 -570
70 4200 0.80 0.15 629 1260 -631
Case 2 assumes a Time of Conoentration less than 5 minutes so that the 75 4500 0.77 0.14 648 1350 -702
peak flow =.90(4.58)(Imp. Area) = 0.62 cfs 80 4800 0.75 0.14 672 1440 -768
85 5100 0.72 0.13 685 1530 -845
90 5400 0.71 0.13 714 1620 -906
So, the Peak flow for the Basin is the greater of the two flows, 95 5700 0.69 0.13 732 1710 -978
0.84 cfs 100 6000 0,67 0.12 748 1800 -1052
208' DRAINAGE POND CALCULATIONS
Required '208' Storage Volume
= Impervious Area x.5 in 112 in/ft 271 cu ft
50 year Volume Provided 271 cu ft
DRYWELL REQUIREMENTS • 10 YEAR DESIGN STOR
Maximum Storage Required by Bowstring 247 cu ft
Number and Type of Orywells Required 1 Single
0 Doub4e
INLAND PACIFIC ENGINEERING
RIVERWALK 9TH ADDITION
CURB INLET CALCULATIONS
Curb Inlet Depression = 2 in.
Standard Curb Inlet Length = 4 ft.
Upstream 10 yr. Gutter Roughness Reciprocal Depth Length
Curb Drop Impervious Peak Flow Slope Coeff. Cross slope of Flow Required
Pond Station R!L Area c.f.s. S n Z Zln d* Qa/La'* Q!(QalLa) Remarks
H 15+25 L 3188 0.21 0.0110 4.0160 50 3125 0.08 0.054 3,86 Need 1- 4' curb inlet
K 16+59 L 5998 0.39 0.0110 0.0160 50 3125 0.10 4.069 5,68 Need 2- 4' curb inlets
P 29+32 L 6502 0.56 0.0080 0.0160 50 3125 0.12 0.065 6,86 Need 2- 4' curb inlets