Loading...
2008, 08-12 Permit App: 08003126 Remodel Project Number: 08003126 Inv: I Application Date: 8/12/2008 Page 1 of 2 THIS IS NOT A PERMIT Penalties will be assessed for commencing work without a permit Project Information: Permit Use: INSTALL(2)EGRESS WINDOWS-REFRAME AND Contact: CONSTRUCTION&ALL REMODELING INSULATE BASEMENT Address: 1602 E CENTER RD C-S-Z: SPOKANE WA 99208 Setbacks:Front Left: Right: Rear: Phone: (509)468-9996 Group Name: Site Information: Project Name Plat Key: 000000 Name: Range District: Sout Parcel Number: 45272.1408 Block: Lot: SiteAddress: 12904 E SALTESE RD Owner:Name: DARLING,JASON E&TRACI M Address: 12904 E SALTESE RD Location::CSV SPOKANE VALLEY,WA 99216 Zoning: R-4 SF Res Urban District Water District: 010 VERA Hold: ❑ Area: 11,616 Sq Ft Width: 0 Depth: 0 Right Of Way(ft): 0 Nbr of Bldgs: 0 Nbr of Dwellings: 0 Review Building Plan Review Released By: Originally Released: 8/12/2008 By: tmelbourn Permits: •,f ..�x. ....... ....- >_...J�< - nni'. ...:�. Snx .' --£nom` - •,� f P Building Permit Contractor: CONSTRUCTION&ALL Firm: CONSTRUCTION&ALL REMDLN Address: 1602 E CENTER RD Phone: (509)468-9996 SPOKANE,WA 99208 This Application: Total Project: Description Grp Type Notes Sq Ft Valuation Sq Ft Valuation BASEMENT F R-3 VB BASEMENT 0 $20,000.00 0 $20,000.00 /EGRESS Totals: 0 $20,000.00 0 $20,000.00 Item Description Units Unit Desc Fee Amount RESIDENTIAL PERMIT FEE 1 SELECT $321.25 WSBC SURCHARGE 1 SELECT $4.50 SF PLNS RVW<7999 SQ FT 1 SELECT $128.50 Permit Total Fees: $454.25 Operator: jmm Printed By: jmm Print Date: 8/12/2008 Project Number: 08003126 Inv: 1 Application Date: 8/12/2008 Page 2 of 2 THIS IS NOT A PERMIT Penalties will be assessed for commencing work without a permit Notes: Payment Summary• Permit Type Fee Amount Invoice Amount Amount Paid Amount Owing Building Permit $454.25 $454.25 $0.00 $454.25 $454.25 $454.25 $0.00 $454.25 Disclaimer: Submittal of this application certifies the owner(or person(s)authorized by the owner)has both examined and finds the information contained within to be true and correct,and agrees that all provisions of laws and/or regulations governing this type of work will be complied with. Subsequent issuance of a permit shall not be construed to be a permit for,or an approval of,any violation of any of the provisions of the code or of any other state or local laws or ordinances. Signature: Operator: jmm Printed By: jmm Print Date: 8/12/2008 Permit Center e--..3/(. (4-,Sp crr oe 11703 E Sprague Ave,Suite B-3 -/ PERMIT NUMBER: okane Spokane Valley,�d 99206 'i EY PERMIT FEE: q --e-/‘ r . ' 4. Valle Y (509)688-0036 FAX: (509)688-00.37 www.spokanevalley.org 4 j b ` 2006 Community Development Residential Construction ; New Construction n Accessory Bldg Permit Application ,/rAddition/Remodel n Deck n Other: SITE ADDRESS: / 7\ 9 Q G SA 67—ESE ASSESSORS PARCEL NO: LEGAL DESCRIPTION: Building Owner: Contractor: Name: JA-sor D 4 f 2 L-2-4, ' Name:cor)srQuCijdi.,44 t6 1f/2"10Di-u Address: / 904_ D4_ E S,,,,- L / sE )/ Address: /6 0 2 E Ci n - z© City: c R.) KA_K) State: w/4. Zip: 7/21// City: -p6 XA_ E-, State: 4/A Zip:/q 5Do Phone: a ` 9 ,q D Fax: Phone: //� rp_ _ 5,996 Fax: 4/_ _ s-77-7 o Contractor`��of con g iA e 7?9 Exp h 1 Date: l�P _ 30 _d S Contact Person City Business Lic.No: ,Name: LU ps ry-12-- CCE g. Phone: L4_G — ?9 9 6 Describe the scope of work in detail: Cost of Project: $ 6 000 o� o f �'v►c7 - Lc 7'coa �'G�2ES.S wlhDoc.. ) S, n / / ve-c-cu/ 2 ,- InS�-l/Q�e bo,SQ✓� veyi- C908 rctne GO4 (pgrc c c D/u.A 1, Q r o(vifWQ// /iv►0Iz' s7-4. iL. DookS d ry,pu IcP) V / cJ Proposed Use: /0/2 se: �C **************The following MUST be complete: (write N/A if not applicable)********************** HEIGHT TO PEAK: DIMENSIONS: #OF STORIES: TOTAL HABITABLE SPACE: MAIN FLOOR TO SQ. 2Nu FLOOR SQ. FTG: UNFIN BASEMENT SQ. FTG: IMPERVIOUS SURFACE FTG: �� AREA: FINISHED BASEMENT GARAGE SQ. FTG: DECK/COV. PATIO SQ. FTG: 30% SLOPES ON SQ. FTG: P RTY: #OF BEDROOMS: CONSTRUCTION TYPE: HEAT SOURCE: SEWER R SEPTIC? / 6,45 The permitee verifies, acknowledges and agrees by their signature that: 1) If this permit is for construction of or on a dwelling,the dwelling is/will be served by potable water. 2) Ownership of this City of Spokane Valley Permit inure to the property owner. 3) The signatory is the property owner or has permission to represent the property owner in this transaction. 4) All construction is to be done in full compliance with the City of Spokane Valley Development Code. Referenced codes are available for review at the City of Spokane Valley Permit Center. 5) This City of Spokane Valley Permit is not a permit or approval for any violation of federal,state or local laws, codes or ordinances.6) Plans or additional information may be required to be submitted, and subsequently approved before this application can be pr cessed. ' / SIGNATURE: 4 DATE: Method of Payment: D Cash Check 0 Mastercard ❑ VISA Bankcard#: Expires: VIN#: Authorized Signature: REVISED 2/15/07 RESIDENTIAL CHECK LIST DIRECTIONS: Place a check mark in box next to each document required for complete submittal. o SITE PLAN o Property lines and dimensions ❑ Setbacks to property lines o Direction arrow pointing North and orientation to streets ❑ Distance between buildings o Proposed/existing buildings (footprint and dimensions) ❑ Right of way/easement location &sizes ❑ Utilities, septic tank/drain field locations and distances o Driveway approach size and location BUILDING PLANS (3 SETS) (minimum 1/8 inch scale or completely dimensioned) ❑ Elevations (Front/Rear/Sides)with roof peak and wall height including basement: ❑ Foundation Plan (crawlspace, basement or slab on grade): o Footing sizes and locations ❑ Supporting wood cripple walls or beams ❑ Perimeter concrete foundation wall sizes ❑ Thickened concrete pads supporting o Crawlspace ventilation beams or girder trusses ❑ Floor Plan of each level (finished or unfinished)with dimensions: o Floor Joist direction, size and spacing o Window and door location and sizes o Header, beam or concrete lintel sizes o Window well locations if applicable o Brace wall panel locations ❑ Room usage labels o Water heater and furnace locations ❑ Smoke detector locations o Exhaust fan locations o Attic and crawl space access locations o Deck or concrete patio sizes and locations ❑ Fire Wall construction ❑ Roof Plan: o Engineered truss direction and spacing o Ridge, eave and valley lines o Rafter and over frame direction, size and spacing o Beam and girder size and location ❑ Wall Section Detail including: Roof o Slope/roofing material/underlayment/ice dam protection ❑ Truss or rafter size, spacing &connection o Sheathing size and type o Attic insulation/air space baffle/ventilation Ceiling o Joist size and spacing o Size of ceiling gypsum wall board Wall o Height/top plate/stud size and spacing/sole plate ❑ Siding/exterior house wrap/anchor bolts o Exterior sheathing size and type o Insulation, vapor barrier, gypsum wall board Floor o Joist size and spacing ❑ Sheathing or concrete floor size/insulation Foundation Wall o Concrete or Masonry unit width o Footing bottom to finished ground level depth o Earth to wood separation distance o Horizontal &vertical reinforcement if any Footing o Size o Reinforcement if any Radon o Passive system with 6mil vapor barrier o Active system with 6 mil vapor barrier Miscellaneous Construction Details ❑ Deck: o Floor plan/side view/dimensions o Footings/post/and beam size and locations o Floor Joist/decking direction, size and spacing O Stairway tread rise & run and nosing 0 Handrail/Guard height &spacing For City Use Only_ t.°, PLUS Project Number i ,12 C SCITY OF pokane Project Address a ° 11703 E Sprague Ave Suite B-3 ♦ Spokane Valley WA 99206 509.688.0036 ♦ Fax: 509.688.0037♦ permitcenter®spokanevalley.org As part of our on-going commitment to customer service during the review process of your project application, we are providing you with a TARGET DATE for the initial technical application review. If for any reason we cannot meet this date, we will contact you with a revised target date. Your application review TARGET DATE is The TARGET DATE is the date we estimate your project application will have had its initial technical review. It is not the date for approval or permit issuance. Tips for a Smoother Project Application Review ➢ Submit complete, accurate plans and documents. Extra time may be required for re-submittals as project application reviewers work on multiple applications and it may be several days before they can look at your new or revised information. ➢ Designate a specific contact person to communicate with the City. While the person designated as the applicant's contact person with the City can be changed, one individual with the expertise for dealing with reviewer comments would be the best choice for the entire review process. ➢ Call staff regarding the status of your project only after the target date shown at the top of the page. Although you should be contacted on or by the target date,please feel free to contact us if you haven't heard from us by your target date. Staff may contact you before the target date if the initial review is complete. By following this procedure,you will save time and allow the reviewers to complete the work more expeditiously. Steps in the Permit Process 1. Counter Complete. Your application has been accepted as counter complete. This means all of the required documents, as indicated on your Pre-Application Checklist have been submitted or have been approved for deferred submittal. This does not prevent technical staff from requesting additional information as a result of their technical review. 2. Quality Check. The next step in the process is a quality check to make sure that the application is reviewable and free from substantive flaws that would prevent technical staff from completing the technical review once it is started. When this step is complete, your application will be routed to the appropriate staff and remain in their review queue until it comes up for review. 3. Technical Compliance. Once an application is administratively complete, it is routed to technical staff for compliance review. Depending on the type of project, technical staff may include multiple reviewers. You should be contacted by phone,fax, email,or mail by your TARGET DATE once the initial technical compliance review is complete. 4. Permit Issuance. When the technical compliance review of the application is complete, including any subsequent re- submittals, each reviewer will approve their section of the application and route it to the Permit Center. When all sections of the application are received, a Permit Specialist will process the application and contact the person specified on your application for permit pick-up. Information regarding fees and pre-construction meetings (if required) will be provided by the Permit Specialist at that time. WHITE-APPLICANT PINK-BUILDING FILE REV 9/07 SIVOliwane 4000 Valley EMERGENCY ESCAPE AND RESCUE EGRESS WINDOW *Minimum 20"wide clear opening *Minimum 24"high clear opening *Minimum 5.7 sq ft openable area **5.0 sq ft minimum @ grade floor *Top of sill maximum of 44" above finished floor 1 34'CLEAR 20"CLEAR MN i / "r/ \\N OPENABLE /' AREA .\\ �- 5.7 SQ FT MIN 41"CLEAR {5.O SQ FT MIN `. ./� 0 GRADE FLOOR) OPENABLE AREA 24'CLEAR 5.7 SQ FT MIN MIN • (5.O SO FT MIN •• GRADE FLOOR) •\ // •\• • MINIMUM SIZE MINIMUM SIZE WINDOW WINDOW FOR 20 IN. FOR 24 IN.CLEAR HEIGHT CLEAR WIDTH SILL HEIGHT 44"MAX T FLOOR Grade floor opening is a window or other openings located such that the sill height of the opening is not more than 44" above or below the finished ground level adjacent to the opening. WINDOW WELL LADDER EGRESS *Minimum 36" x 36" *At least 12" in width *Minimum 9 sq.fl clear floor area *Rungs not more than 18" on center *Top of wall a maximum of 44" above *Minimum 3" toe space the floor of the well *Permanently fixed *A guardrail is not required unless an *Non-combustible exit way adjoins the well. *Shall extend to top of wall *Provide drainage DEEP WELLS *If the top of the window well wall is more than 44" above the floor of the well, either a permanently fixed ladder or stair egress is required. *The ladder or stair may encroach a maximum of 6" into the required clear floor space. LADDER OR STAIR PERMITTED NET CLEAR DIMENSIONS WHEN TO ENCROACH MAXIMUM OF FULLY OPENED TO PROVIDE 6 INCHES INTO REQUIRED 9 SQUARE FEET OF OPENING DIMENSIONS WINDOW WELL \\\V/• I 7„ LADDER OR STAIR .\\\ O--0 REQUIRED ,/// \\\ 1 36'MIN \\\ .„. 'iii ' EMERGENCY ESCAPE '///' 7//' OR RESCUE OPENING \\\'///\\ '///.\\\'///s\\\'/ii\\\`///‘\\\'/// \\' WITH FINISHED SILL '///" HEIGHT BELOW '///.\\-\ 0,N\'///. ADJACENT GRADE .\\\. 36'MIN .\\\ '///' *Where bars, grills, covers, screens or similar devices are installed over emergency escape and rescue openings, they must be openable from the inside without the need of special knowledge or special tools, and the force to open them may not be greater than that required of the opening itself. WASHINGTON STATE ENERGY CODE • TABLE 6-2 PRESCRIPTIVE REQUIREMENT S°'1 FOR GROUP R OCCUPANCY CLIMATE ZONE 2 Glazing Glazin U-Factors Walltz Area'°: Wall. Wall. Slabs Option n Door z Vaulted Above Bintelow Below ext Floors on Ceiling %of Floor Vertical Overhead" U-Factor Ceiling3 Grade Grade Grade Grade I. 12% 0.35 0.58 0.20 R-38 R-30 R-21 R-21 R-12 R-30 R-10 int" II.* 15% 0.35 0.58 0.20 R-38 R-30 R-19+ R-21 R-12 R-30 R-10 R-58 III. 17% 0.32 0.58 0.20 R-38 R-30 R-19+ R-21 R-12 R-30 R-10 R-58 IV. 25% 0.35 0.58 0.20 R-38/ R-30/ R-21 R-15 R-12 R-30/ R-10/ Group R-1 U=0.031 U=0.034 int' / U=0.029 F=0.54 and R-2 U=0.054 Occupancies Only V. Unlimited 0.35 0.58 0.20 R-38 R-30 R-19+ R-21 R-12 R-30 R-10 Group R-3 R-58 and R-4 Occupancies Only VI. Unlimited 0.30 0.58 0.20 R-49 or R-38 R-21 R-21 R-12 R-30 R-10 Group R-3 R-38 Adv int' and R-4 Occupancies Only VII. Unlimited 0.32 0.58 0.20 R-38/ R-30/ R-21 R-15 R-12 R-30/ R-10/ Group R-1 U=0.031 U=0.034 int' / U=0.029 F=0.54 and R-2 U=0.054 Occupancies Only * Reference Case 0. Nominal R-values are for wood frame assemblies only or assemblies built in accordance with Section 601.1. 1. Minimum requirements for each option listed. For example,if a proposed design has a glazing ratio to the conditioned floor area of 13%,it shall comply with all of the requirements of the 15%glazing option(or higher). Proposed designs which cannot meet the specific requirements of a listed option above may calculate compliance by Chapters 4 or 5 of this Code. 2. Requirement applies to all ceilings except single rafter or joist vaulted ceilings complying with note 3. 'Adv'denotes Advanced Framed Ceiling. 3. Requirement applicable only to single rafter or joist vaulted ceilings where both(a)the distance between the top of the ceiling and the underside of the roof sheathing is less than 12 inches and(b)there is a minimum 1-inch vented airspace above the insulation. Other single rafter or joist vaulted ceilings shall comply with the"ceiling"requirements.This option is limited to 500 square feet of ceiling area for any one dwelling unit. 4. Below grade walls shall be insulated either on the exterior to a minimum level of R-12,or on the interior to the same level as walls above grade. Exterior insulation installed on below grade walls shall be a water resistant material,manufactured for its intended use,and installed according to the manufacturer's specifications. See Section 602.2. 5. Floors over crawl spaces or exposed to ambient air conditions. 6. Required slab perimeter insulation shall be a water resistant material,manufactured for its intended use,and installed according to manufacturer's specifications. See Section 602.4. 7. Int.denotes standard framing 16 inches on center with headers insulated with a minimum of R-10 insulation. 8. This wall insulation requirement denotes R-19 wall cavity insulation plus R-5 foam sheathing. 9. Doors,including all fire doors,shall be assigned default U-factors from Table 10-6C. 10. Where a maximum glazing area is listed,the total glazing area(combined vertical plus overhead)as a percent of gross conditioned floor area shall be less than or equal to that value. Overhead glazing with U-factor of U=0.40 or less is not included in glazing area limitations. 11. Overhead glazing shall have U-factors determined in accordance with NFRC 100 or as specified in Section 502.1.5. 12. Log and solid timber walls with a minimum average thickness of 3.5"are exempt from this insulation requirement. 34 Effective July 1, 2007 • . clo sr In , ` EMERGENCY EGRESS REQUIREMENTS \, b FROM SLEEPING ROOMS R 1)NET CLEAR OPENING: 5.7 SQUARE FEET 4 LLI C.1 D GRADE FLOOR OPENING(MAX 44") 5.0 SQUARE FEET 2)NET CLEAR OPENING HEIGHT 24 INCHES 33 U.. ht _ 0 3)NET CLEAR OPENING WIDTH 2O INCHES ® pr • O S 4)MAX FINISHED SILL HEIGHT 44•ABOVE FLOOR • 51 EMERGENCY ESCAPE&RESCUE OPENING SHALL BE + A OPERATIONAL FROM THE INSIDE OF THE ROOM WITHOUT 1 S C), 12904 E. Saltese Ave. THE USE OF KEYS OR TOOLS _ 34.5' 10' 11' WHEN INTERIOR ALTERATIONS,REPAIRS OR ADDITIOI .C) .. -?i---7--- I. REQUIRING A PERMIT OCCUR,OR WHEN ONE OR MO m i/I L SLEEPING ROOMS ARE ADDED OR CREATED IN EXISTIN LA _ v W/D sin DWELLINGS, THE DWELLING UNIT SHALL BE PROVIDE v "` office/exercise area WITH SMOKE ALARMS LOCATED AS REQUIRED FOR NE DWELLINGS. M,o d ' g Ao - .p bedroont laundry room/ storage room CEJ Lxt' -LJ' SSMOKE ALARMS SHALL BE INTERCO E' _ ,Xt� 10' NECTED AND HARD WIRED IN SUCH 0 MANNER THAT THE ACTIVATION OF O t ALARM WILL ACTIVATE ALL ALARM 1 . = (BEDROOMS, AREAS APPROACHIN BEDROOMS , VAULTED CEILIN WITH RISE OF 24' & ON EACH FLOOR) cr leD- b EXHAUST FANS 100'CF114 kitchen 26'5" 50 CFM bathrooms - .- - replaec - I _. _- & lantlt�y J&./Lr-r---o H20 access for gas valve om, EXT cc;.i&- furnace [ — sliding ac ess doors WashingStaVentilation / Cons bu-s no N Atm , 1 5, and Indoor Air Quality Code RrcORe_0 \ rec. room/family 2 re uires a sources ecific and walk-in room 9 p closet 1 0 bathroom ( whole house ton ventilation system corner (toilet (vanity// +�j` Egress windows openable sho 5.7 sq. ft. 44" sill closet/Pum 0°4`•, ` __ P / - __ / 1��� ele icai panel - — 5 i egress? H� Aa ctvt_"(pi Awn,. sewer exit (. ) 2)(4 c)A- C?)Z X 1t+j - '•-•• Lha •- • PROVIDE DIAGRAMS AND ENGINEERING LAYOUTS FOR ROOF TRUSSES, BEAMS AND FLOOR SYSTEMS PRIOR TO FRAMING INSPECTIONS CITY COPY THIS BUILDING SUBJECT TO FIELD INSPECTfON CORRECTIONS • SPEW SPOKANE VALLEY BUIL ING D ISION f 2-- OMPQA;CE REVIEWED FOR CODE