2014, 10-30 Energy Compliance CertificateConditioned Floor AreaL. ( 2 -
Builder
Builder or registered design professional : r
NFRC rating (or)
Default rating (Chapter 10 W EC 2009)
All ducts & HVAC in conditioned space ( yes /no )
Test Method: Total leakage Leakage to exterior Air handler present
Test Target CFM@25Pa Test Result CPM@25Pa
Building air leakage target: SLA<0.00030 - Tested leakage: SLA= L(, 30
uucr ► esr►ng ca►cu►aror (mew consrrucr►anJ
House address or lot #:
Conditioned Floor Area:
Duct tester location:
Pressure tap location:
Ring (if applicable):
`-1 Z-[ il.L'° , 11,P1 ,2cYL4
Z G, Z V
Y
t,.z,,,y, - o [
Open ❑ 1 D 2 [1 ❑
At Rough -in or Post Construction
Test Method
Standards
Calculated
Target
Test'
CFM25
Air Handler Present (Leakage
to Exterior or Total Leakage)
< 4 CFM2; per 100 sf of CFA
Air Handier not Present
<_ 3 CFM25 per 100 sf of CFA
(Leakage to Exterior or Total Leakage)
1. Test CFM25 must be equal to or less than the calculated target.
Air Leakage testing Calculator (Blower Door Tes
Conditioned Floor Area:
Ceiling Hieght (ft)
2c.,2 g
Calculated Volume (cubic feet)
Y
0
Standard
Tested CFM50
Calculated Test
Result (ACH50)
__5.0 ACH50 (CFM50X
60 _ conditioned Volume)
/ S— 1
(.__(,,4 o
Glossary
Rough-ln: After installation of the complete air distribution system but before installation of insulation and
sheet rock. Allows for access to all duct seams and connections for re-evaluation of seal integrity if standard
is not met in intitial test.
Post Construction: At or near final inspection. The home must be complete enough to pressurize the home
to 25 pa.
Total Leakage: Aggregation of the entire systems duct leakage in a duct test.
Leakage to Exterior: Aggregation of all duct system Teaks to the exterior of the CFA in a duct test.
Pascal (pa): Unit of pressure
CFA: Conditioned floor area in square feet
CFM25: Cubic feet per minute of air leakage at 25 pascals of pressure
CFM50: Cubic feet per minute of air leakage at 50 pascals of pr€
Conditioned Volume: Volume of conditioned space (CFA X ceil
ACH50: Air changes per hour at 50 pascals of pressure
(_;2' ,JIL-(