2007, 04-12 Permit App: 07001251 RemodelProject Number: 07001251 Inv: 1
Application Date: 4/12/2007 Page 1 of 2
THIS IS NOT A PERMIT
Penalties will be assessed for commencing work without a permit
Project Information:
Permit Use: FINISH BSMNT
Setbacks: Front
Site Information:
Plat Key: 006156 Name: SHELLEY LAKE 03RD ADD PUD
Left: Right:
Rear:
Contact:
Address:
C - S - Z:
Phone:
Group Name:
Project Name:
CASCADE MEADOWS CONSTRUCTIO
PO BOX 371
SPOKANE VALLEY, WA 99016
(509) 892-7950
District: East
Parcel Number: 45244.2801 Block: 2
SiteAddress: 902 S SHELLEY LAKE LN
Location:: CSV
Zoning: UR -3.5 Urban Residential 3.5
Water District: 010 VERA
Area: 12,094 Sq Ft
Width: 101
Nbr of Bldgs: 1 Nbr of Dwellings: 1
Review Information: =mamma
Lot: 1
Owner: Name: FLINT, JOY ANN
Address: 902 S SHELLEY LAKE LN
VERADALE, WA 99037
Hold: ❑
Depth: 136 Right Of Way (ft): 30
Review
Building Plan Review
Permits:
Released BY:
7
Contractor: CASCADE MEADOWS
Address: PO BOX 371
SPOKANE VALLEY, WA 99016
Description Gra Type Notes
BASEMENT F R-3 VB
Item Description
RESIDENTIAL PERMIT FEE
WSBC SURCHARGE
SF PLNS RVW < 7999 SQ FT
Operator: JD
Building Permit
Totals:
Units
1
1
1
Printed By: JD
Firm: CASCADE MEADOWS CONSTRU
Phone: (509) 892-7950
This Application:
Sq Ft Valuation
1,600 $32,000.00
1,600 $32,000.00
Unit Desc
SELECT
SELECT
SELECT
Permit Total Fees:
Print Date:
Total Project:
Sq Ft Valuation
1,600 $32,000.00
1,600
Fee Amount
$461.95
$4.50
$184.78
$651.23
4/12/2007
$32,000.00
Project Number: 07001251 Inv: 1
Notes:
Application
THIS IS NOT A PERMIT
Penalties will be assessed for commencing work without a permit
Date: 4/12/2007 Page 2 of 2
Payment Summary:
Permit Type
Building Permit
Fee Amount Invoice Amount Amount Paid Amount Owing
$651.23 $651.23
$0.00 $651.23
$651.23 $651.23 $0.00 $651.23
Disclaimer:
Submittal of this application certifies the owner (or person(s) authorized by the owner) has both examined and finds the information
contained within to be true and correct, and agrees that all provisions of laws and/or regulations governing this type of work will be
complied with. Subsequent issuance of a permit shall not be construed to be a permit for, or an approval of, any violation of any of
the provisions of the code or of any other state or local laws or ordinances.
Signature:
Operator: JD Printed By: JD
Print Date: 4/12/2007
Spokane
jValley
Community Development
Residential Construction
Permit Application
Permit Center
11703 E Sprague Ave, Suite B-3
Spokane Valley, WA 99206
(509)688-0036 FAX: (509)688-0037
www.spokanevalley.org
PERMIT NUMBER: )
PERMIT FEE:
I
New Construction
Addition/Remodel
n Other:
Accessory Bldg
Deck
SITE ADDRESS:
loz S'
ASSESSORS PARCEL NO: LEGAL DESCRIPTION:
ding
�
On
JBuilOwner:
Name:
TOTAL HABITABLE SPACE:
ti/k
Address. C/02._S J�
Z 4.e 6 , .
City: // 0 Sta :
Zip:�`40�-2
Phone: (c \ q Z/ — � � Fax:
GARAGE SQ. FTG:
kV/.
Contact Person
Name:
Phone:
g�2-�5sz�
Describe the scope of work in detail:
Contractor: 144e4 (✓0
�9 �r
/}Gast
Name: .JG'V� l'- -54»-
TOTAL HABITABLE SPACE:
ti/k
Address: IPU (30), ?-71
2ND FLOOR SQ. FTG:
lit'
City:` 44, fj State: 40
Zip: 5)64
Phone.( 8/2ct7Fax:
GARAGE SQ. FTG:
kV/.
Contractor tic Non/se/4101 (:..q ['ate:
1. [
h,_,
City Business Lic. No: /
CONSTRUCTION TYPE:
14_4-Cz,�
are,, in, -,s
Proposed Use:
/
Cost of Project: $ f'z crop
a., f �t�;✓ , ,iieztna_ S 'cben
/ Sl.ec-f :: 7 %,/'ei ,�'+c �, •�r
**************The following MUST be complete: (write N/A if not applicable)**********************
HEIGHT TO PEAK:
/1
DIMENSIONS:
# OF STORIES:
fr),-
TOTAL HABITABLE SPACE:
ti/k
MAIN FLOOR TO SQ.
FTG:
l'tif
2ND FLOOR SQ. FTG:
lit'
UNFIN BASEMENT SQ. FTG:
/ (ch.)
IMPERVIOUS SURFACE
AREA:
lvf-
FINISHED BASEMENT
SQ. FTG: /.c,/D
GARAGE SQ. FTG:
kV/.
DECK/COV. PATIO SQ. FTG:
41/9
30% SLOPES ON
PROPERTY:
# OF BEDR6OMS:
Z
CONSTRUCTION TYPE:
14_4-Cz,�
HE SOURCE:
SEWS OR SEPTIC?
The permitee verifies, acknowledges and agrees by their signature that: 1) If this permit is for construction of or on a dwelling, the
dwelling is/will be served by potable water. 2) Ownership of this City of Spokane Valley Permit inure to the property owner. 3) The
signatory is the property owner or has permission to represent the property owner in this transaction. 4) AH construction is to be done
in full compliance with the City of Spokane Valley Development Code. Referenced codes are available for review at the City of
Spokane Valley Permit Center. 5) This City of Spokane Valley Permit is not a permit or approval for any violation of federal, state or
local laws, codes or ordinances. 6) Plans or additional information may be required to be submitted, and subsequently approved before
this application can beRrocessed.
SIGNATURE:
ethod of Paym
Cash
ankcard #:
Authorized Signature:
REVISED 2/15/07
DATE: f -/—/O
❑ Mastercard 0 VISA
Expires: VIN#:
Spokane
11703 E Sprague Ave Suite B-3 ♦ Spokane Valley WA 99206
509.688.0036 ♦ Fax: 509.688.0037 ♦ cityhall@spokanevaltey.org
Residential Plan Submittal Minimums
❑ Completed Building & Mechanical application with: Accurate address, Parcel
Number and/or Legal Description, description of work, owner and contractor
information, signature, and date.
O Two sets of plans including Site Plan, elevations, floor plans, foundation plans
With details, roof plan, framing plans & details.
❑ Show the height of any proposed buildings or accessory structures.
O Floor plan for each floor: Dimension to scale (minimum 1/8") and label each
Room (including sq. footage of house and garage on plans) Show each
level of existing house and square footage of any additions.
O All braced wall panel types: show locations and details of installation, including
engineered design.
❑ Egress windows: Provide at least one window or exterior door approved for
Emergency escape or rescue from a basement and in every room for sleeping.
O Smoke detector locations
❑ 22" X 30" attic access location
❑ 18" X 24" crawl space access:
❑ One-hour separation detail: between house and garage
❑ Floor framing details: Joist type, size, spacing and installation details
❑ Roof framing plan and details
❑ Furnace and hot water heater location.
❑ All header locations: type, size, and connections
❑ Foundation plan
O Insulation information
Project Number: 07001251 Inv: 1
Application
THIS IS NOT A PERMIT
Penalties will be assessed for commencing work without a permit
Date: 4/12/2007 Page 1 of 2
Project Information:
Permit Use: FINISH BSMNT
Setbacks: Front
Site Information:
Plat Key: 006156 Name: SHELLEY LAKE 03RD ADD PUD
Left: Right: Rear:
Contact:
Address:
C - S - Z:
Phone:
Group Name:
Project Name:
CASCADE MEADOWS CONSTRUCTIO
PO BOX 371
SPOKANE VALLEY, WA 99016
(509) 892-7950
District: East
Parcel Number: 45244.2801 Block: 2
SiteAddress: 902 S SHELLEY LAKE LN
Location:: CSV
Zoning: UR -3.5 Urban Residential 3.5
Water District: 010 VERA
Area: 12,094 Sq Ft
Nbr of Bldgs: 1 Nbr of Dwellings: 1
Width: 101
Review Information: ateomfazow-
Review
Building Plan Review
Permits:
Lot: 1
Owner: Name: FLINT, JOY ANN
Address: 902 S SHELLEY LAKE LN
VERADALE, WA 99037
Hold: ❑
Depth: 136 Right Of Way (ft): 30
Released By: z. G
aNfa NZ +..,ten,:': %'"_ -' ° NNWJEF `M , . 3a a%ME
Contractor: CASCADE MEADOWS
Address: PO BOX 371
SPOKANE VALLEY, WA 99016
Description Gro Type Notes
BASEMENT F R-3 VB
Item Description
RESIDENTIAL PERMIT FEE
WSBC SURCHARGE
SF PLNS RVW < 7999 SQ FT
Operator: .JD
Building Permit
Firm: CASCADE MEADOWS CONSTRU
Phone: (509) 892-7950
This Application:
Sq Ft Valuation
1,600 $32,000.00
Totals: 1,600 $32,000.00
Units Unit Desc
1 SELECT
1 SELECT
1 SELECT
Printed By: JD
Permit Total Fees:
Print Date:
Total Project:
Sq Ft Valuation
1,600 $32,000.00
1,600 $32,000.00
Fee Amount
$461.95
$4.50
$184.78
$651.23
4/12/2007
Project Number: 07001251 Inv: 1
Notes:
Application
THIS IS NOT A PERMIT
Penalties will be assessed for commencing work without a permit
Date: 4/12/2007 Page 2 of 2
Payment Summary:
Permit Type
Building Permit
Fee Amount Invoice Amount Amount Paid Amount Owing
$651.23 $651.23 $0.00 $651.23
$651.23 $651.23 $0.00 $651.23
Disclaimer:
Submittal of this application certifies the owner (or person(s) authorized by the owner) has both examined and finds the information
contained within to be true and correct, and agrees that all provisions of laws and/or regulations governing this type of work will be
complied with. Subsequent issuance of a permit shall not be construed to be a permit for, or an approval of, any violation of any of
the provisions of the code or of any other state or local laws or ordinances.
Signature:
Operator: JD Printed By: JD Print Date: 4/12/2007
WSEC TABLE 6-2
PRESCRIPTIVE REQUIREMENTS°'1 FOR GROUP R OCCUPANCY
CLIMATE ZONE 2
* Reference Case
0. Nominal R -values are for wood frame assemblies only or assemblies built in accordance with
Section 601.1.
1. Minimum requirements for each option listed. For example, if a proposed design has a glazing ratio
to the conditioned floor area of 13%, it shall comply with all of the requirements of the 15% glazing
option (or higher). Proposed designs which cannot meet the specific requirements of a listed option
above may calculate compliance by Chapters 4 or 5 of this Code.
2. Requirement applies to all ceilings except single rafter or joist vaulted ceilings.
3. Requirement applicable only to single rafter or joist vaulted ceilings.
4. Below grade walls shall be insulated either on the exterior to a minimum level of R-10, or on the
interior to the same level as walls above grade. Exterior insulation installed on below grade walls
shall be a water resistant material, manufactured for its intended use, and installed according to the
manufacturer's specifications. See Section 602.2.
5. Floors over crawl spaces or exposed to ambient air conditions.
6. Required slab perimeter insulation shall be a water resistant material, manufactured for its intended
use, and installed according to manufacturer's specifications. See Section 602.4.
7. Int. denotes standard framing 16 inches on center with headers insulated with a minimum of R-5
insulation.
WSEC Builder's Field Guide 5th Edition
COOPERATIVE EXTENSION
WASHINGTON STATE UNIVERSITY
ENERGY PROGRAM
1-7
Glazing U -Factor
Door9
U-
Factor
Ceilin z
9
Vaulted
Ceiling
Wall 2
Above
Grade
Wall?
int°
Below
Grade
Wall?
e>3"
Below
Grade
Floors
slabs
on
Grade
Option
Glazing
Area1°:
%of floor
Vertical
Overhead"
I.
10%
0.40
0.58
0.20
R-38
R-30
R-21
int'
R-21
R-12
R-30
R-10
II.
15%
0.40
0.58
0.20
R-38
R-30
R-19+
R-58
R-21
R-12
R-30
R-10
III.
17%
0.37
0.58
0.20
R-38
R-30
R-19+
R-55
R-21
R-12
R-30
R-10
IV.
25%
Group R-1
Occupancy
Only
0.35
0.58
0.20
R-38 /
U=0.031
R-30 /
U=0.034
R-21
int' /
U=0.054
R-15
R-12
R-301
F=0.5410/
V.
Unlimited
Group R-3
Occupancy
Only
0.35
0.58
0.20
R-38
R-30
R-21
int'
R-21
R-12
R-30
R-10
VI.
Unlimited
Group R-1
Occupancy
Only
0.32
0.58
0.20
R-38 /
U=0.031
R-30 /
U=0.034
R-21
int' /
U=0.054
R-15
R-12
R -31F=10
U=0.029
/
4
* Reference Case
0. Nominal R -values are for wood frame assemblies only or assemblies built in accordance with
Section 601.1.
1. Minimum requirements for each option listed. For example, if a proposed design has a glazing ratio
to the conditioned floor area of 13%, it shall comply with all of the requirements of the 15% glazing
option (or higher). Proposed designs which cannot meet the specific requirements of a listed option
above may calculate compliance by Chapters 4 or 5 of this Code.
2. Requirement applies to all ceilings except single rafter or joist vaulted ceilings.
3. Requirement applicable only to single rafter or joist vaulted ceilings.
4. Below grade walls shall be insulated either on the exterior to a minimum level of R-10, or on the
interior to the same level as walls above grade. Exterior insulation installed on below grade walls
shall be a water resistant material, manufactured for its intended use, and installed according to the
manufacturer's specifications. See Section 602.2.
5. Floors over crawl spaces or exposed to ambient air conditions.
6. Required slab perimeter insulation shall be a water resistant material, manufactured for its intended
use, and installed according to manufacturer's specifications. See Section 602.4.
7. Int. denotes standard framing 16 inches on center with headers insulated with a minimum of R-5
insulation.
WSEC Builder's Field Guide 5th Edition
COOPERATIVE EXTENSION
WASHINGTON STATE UNIVERSITY
ENERGY PROGRAM
1-7
cated in the immediate vicinity of the bottom landing of the
stairway.
Exception: An artificial light source is not required at the
top and bottom landing, provided an artificial light source is
located directly over each stairway section.
R303.6.1 Light activation. The control for activation of the
required interior stairway lighting shall be accessible at the
top and bottom of each stairway without traversing any
steps. The illumination of exterior stairways shall be con-
trolled from inside the dwelling unit.
Exception: Lights that are continuously illuminated or
automatically controlled.
R303.7 Required glazed openings. Required glazed openings
shall open directly onto a street or public alley, or a yard or court
located on the same lot as the building.
R303.7.1 Roofed porches. Required glazed openings may
face into a roofed porch where the porch abuts a street, yard
or court and the longer side of the porch is at least 65 percent
open and unobstructed and the ceiling height is not less than
7 feet (2134 mm).
R303.8 Required heating. When the winter design tempera-
ture in Table R301.2(1) is below 60°F (16°C), every dwelling
unit shall be provided with heating facilities capable of main-
taining a minimum room temperature of 68°F (20°C) at a point
3 feet (914 mm) above the floor and 2 feet (610 mm) from exte-
rior walls in all habitable rooms at the design temperature. The
installation of one or more portable space heaters shall not be
used to achieve compliance with this section.
SECTION R304
MINIMUM ROOM AREAS
R304.1 Minimum area. Every dwelling unit shall have at least
one habitable room that shall have not less than 120 square feet
(11.2 m2) of gross floor area.
R304.2 Other rooms. Other habitable rooms shall have a floor
area of not less than 70 square feet (6.5 m2).
I Exception: Kitchens.
R304.3 Minimum dimensions. Habitable rooms shall not be
less than 7 feet (2134 mm) in any horizontal dimension.
Exception: Kitchens.
R304.4 Height effect on room area. Portions of a room with a
sloping ceiling measuring less than 5 feet (1524 mm) or a
furred ceiling measuring less than 7 feet (2134 mm) from the
finished floor to the finished ceiling shall not be considered as
contributing to the minimum required habitable area for that
room.
SECTION R305
CEILING HEIGHT
R305.1 Minimum height. Habitable rooms, hallways, corri-
dors, bathrooms, toilet rooms, laundry rooms and basements
BUILDING PLANNING
shall have a ceiling height of not less than 7 feet (2134 mm).
The required height shall be measured from the finish floor to
the lowest projection from the ceiling.
Exceptions:
1. Beams and girders spaced not less than 4 feet (1219
mm) on center may project not more than 6 inches
(152 mm) below the required ceiling height.
2. Ceilings in basements without habitable spaces may
project to within 6 feet, 8 inches (2032 mm) of the fin-
ished floor; and beams, girders, ducts or other ob-
structions may project to within 6 feet, 4 inches (1931
mm) of the finished floor.
3. Not more than 50 percent of the required floor area of
a room or space is permitted to have a sloped ceiling
less than 7 feet (2134 mm) in height with no portion of
the required floor area less than 5 feet (1524 mm) in
height.
4. Bathrooms shall have a minimum ceiling height of 6
feet 8 inches (2036 mm) over the fixture and at the
front clearance area for fixtures as shown in Figure
R307.2. A shower or tub equipped with a showerhead
shall have a minimum ceiling height of 6 feet 8 inches
(2036 mm) above a minimum area 30 inches (762
mm) by 30 inches (762 mm) at the showerhead.
SECTION R306
SANITATION
R306.1 Toilet facilities. Every dwelling unit shall be provided
with a water closet, lavatory, and a bathtub or shower.
R306.2 Kitchen. Each dwelling unit shall be provided with a
kitchen area and every kitchen area shall be provided with a
sink.
R306.3 Sewage disposal. All plumbing fixtures shall be con-
nected to a sanitary sewer or to an approved private sewage dis-
posal system.
R306.4 Water supply to fixtures. All plumbing fixtures shall
be connected to an approved water supply. Kitchen sinks, lava-
tories, bathtubs, showers, bidets, laundry tubs and washing ma-
chine outlets shall be provided with hot and cold water.
SECTION R307
TOILET, BATH AND SHOWER SPACES
R307.1 Space required. Fixtures shall be spaced as per Figure
R307.2.
R307.2 Bathtub and shower spaces. Bathtub and shower
floors and walls above bathtubs with installed shower heads
and in shower compartments shall be finished with a
nonabsorbent surface. Such wall surfaces shall extend to a
height of not less than 6 feet (1829 mm) above the floor.
2003 INTERNATIONAL RESIDENTIAL CODE® 45
r a tGur t�z „"•.r't v 2
LIsC��
fig1 r
l
It
rL
S ..� 1� / r y •n -. • _.'nom ��...�.. _-.-.._ 22�� �.._... � w j � � C �
"IN Ali
! C 4 i
11 •3� � ;` ��. '✓ it � .;l•�(,i.-.'i t���or`S �'
CA Cr �x
- )
13
�')it � � t, � � l `��_j �` ..,. —_,_-- ,,,""t-.-':_'�.... _._--=".;=—""�-^'.-- •---"� `- � j
I - .
u 4 I ��� H y !
10
�qq t 3 w t
/�� { cl t � , ls;Rl�3alvaFia w vi ` {I
! a �% Z - 1` au` 7UU 1
[ O\J� OT RMA y0lfl" 2kv 3T2Y'L Ffl01
{
3 _ { aUtM by 2IAOIT3392VI1 I
��.cl
ddtt � I
� ,;!! b-. /(('� rye,,• NS Y. 1 ,.F �,., .
(I i
q�r
rr
J& dlk,�
13
it
i
�� ?11� lTv�2l^ICJ.f�I�tJT
!; s �` �1t1011��'ui'
!
i
-- -- 5 2
EMERGENCY EGRESS REQUIREMENTS
FROM SLEEPING ROOMS -
t j NET CLEAR OPENING: . 5.7 SQUARE FELI
GRADE FLOOR OPENING (MAX 44') 5.0 SQUARE FEET
2) NET CLEAR OPENING HEIGHT 241NCHES
3) NET CLEAR OPENINGYNOTH 2O INCHES
4) MAX FINISHED SILL HEIGHT 44'ABOVEFLOOR
5) EMERGENCY ESCAPE & RESCUE OPENING SHALLBE
OPERATIONAL FROM THE "SIDE OF THE ROOMWITHOUT
THE USE OF KEYS OR TOOLS
WHEN INTERIOR ALTERATIONS, REPAIRS OR ADDITIONS
REQUIRING A PERMIT OCCUR. OR WHEN ONE OR MORE:
SLEEPING ROOMS ARE ADDED OR CREATED INEXISTWG
DWELLINGS. THE DWELLING UNIT SHALL BE PROVIDED
WITH SMOKE ALARMS LOCATED AS REQUIRED FOR NEW
DWELLINGS.
SMOKE ALARMS SHALL ,SE
INTERCON-NECTED AND, HARD WIRED IN SUCH A
MANNER THAT THE ACTIVATION OF ONE
ALARM WILL ACTIVATE ALL ALARMS.
(BEDROOMS, AREAS APPROACHING
BEDROOMS;: VAULTED CEILING
WITH RISE OF 24' & ON EACH FLOOR)
EXHAUST FANS
l'601CFM kitchen
50'CF 41bathrooms
&Iauniiry ;idxizat�'
-r;-.; 4t- 1�-rtR4.c o R
i
WINDOW WELL:
Min. 9 sq. ft. horizontal area
�' , Min. 3 ft. horizontal projection and width -
f, Max. 44 in. vertical depth without a ladder
0
'q LL -1
,it -0-7
0
PROVIDE DIAGRAMS AND
ENGINEERING LAYOUTS FOR
ROOF TRUSSES, BEAMS AND
FLOOR SYSTEMS PRIOR TO FRAMING
INSPECTIONS
CITY COPY
THIS BUILDING SUBJECT
TO FIELD INSPECTION CORRECTIONS
njoimie
(2,0DE
ASION