Loading...
2004, 03-11 Permit: BLD-04-03740 Garage CITY Spokane .,,,.01,lalley ACCESSORY BUILDING PERMIT 11707 E.Sprague Ave., Suite 106 Spokane Valley,WA 99206 Permit#: BLD-04-03740 Job Address: 412 N SONORA ST Applied: 03/11/2004 SPOKANE VALLEY WA 99037 Issued: 04/01/2004 Description: 24 X 24 GARAGE W/BREEZEWAY TO MANUFACTURED HOME Expires: 09/07/2004 Subdivision: Lot: Blk: Parcel No: Zoning: Owner: FERGUSON, EVELYN Applicant: MOBILE CORRAL Phone: (509)928-3003 Address: 15906 E SPRAGUE AVE VERADALE,WA 99037-8964 Contractor: MOBILE CORRAL HOMES Phone: (509)928-3003 Address: 15906 E SPRAGUE AVE Lic No: MOBILCI093O6 VERDALE WA 99037 General Information: Fees: VALUATION 14544 PLAN CHECK FEE 25.13 BUILDING HEIGHT TO PEAK 12 BASIC PERMIT FEE 251.25 DIMENSIONS 24 X 34 WSBCC SURCHARGE 4.50 #OF STORIES 1 Total Calculated: 280.88 FRONT SETBACK 36+ Deposits/Receipts: 280.88 REAR SETBACK 50+ LEFT SETBACK 5 Total Due: 0.00 RIGHT SETBACK N/A OCCUPANCY GROUP u-1 CONSTRUCTION TYPE wood STRUCTURES ON PROPERTY 2 CURRENT PROPERTY SIZE 105 X 135 SERVED BY SEPTIC SYSTEM no WELLS LOCATED ON PROPERTY no Disclaimer: The permitee verifies,acknowledges and agrees by their signature that: 1)If this permit is for construction of or on a dwelling,the dwelling is/will be served by potable water. 2) Ownership of this City of Spokane Valley Permit inure to the property owner. 3)The signatory is the property owner or has permission to represent the property owner in this transaction. 4)All construction is to be done in full compliance with the City of Spokane Valley Development Code. Referenced codes are available for review at the City of Spokane Valley Permit Center. 5)This City of Spokane Valley Permit is not a permit or approval for any violation of federal,state or local laws,codes or ordinances. Ownership of resulting development rights granted by any issued permit inure to the property owner. dAvjA ,A1di44 STjs/2x Date Print Name Signature Staff Initials THIS IS NOT A RECEIPT THIS IS NOT A PERMIT Sithrokane / Penalties will be assessed for commencing work without a permit 4_. 00Valley ACCESSORY BUILDING 11707 E.Sprague Ave.,Suite 106 Spokane Valley,WA 99206 Application#: BLD-04-03740 Job Address: 412 N SONORA ST Applied: 03/11/2004 SPOKANE VALLEY WA 99037 Issued: Description: 24 X 24 GARAGE W/BREEZEWAY TO MANUFACTURED HOME Expires: 09/07/2004 Subdivision: Lot: Blk: Parcel No: Zoning: Owner: FERGUSON, EVELYN Applicant: MOBILE CORRAL Phone: (509)928-3003 Address: 15906 E SPRAGUE AVE VERADALE,WA 99037-8964 Contractor: MOBILE CORRAL HOMES Phone: (509)928-3003 Address: 15906 E SPRAGUE AVE Lic No: MOBILCI093O6 VERDALE WA 99037 General Information: Fees: VALUATION 14544 PLAN CHECK FEE 25.13 BUILDING HEIGHT TO PEAK 12 BASIC PERMIT FEE 251.25 DIMENSIONS 24 X 34 WSBCC SURCHARGE 4.50 #OF STORIES 1 Total Calculated: 280.88 FRONT SETBACK 36+ Deposits/Receipts: 0.00 REAR SETBACK 50+ LEFT SETBACK 5 Total Due: 280.88 RIGHT SETBACK N/A OCCUPANCY GROUP u-1 CONSTRUCTION TYPE wood STRUCTURES ON PROPERTY 2 CURRENT PROPERTY SIZE 105 X 135 SERVED BY SEPTIC SYSTEM no WELLS LOCATED ON PROPERTY no THIS IS NOT A RECEIPT EJEL-'AP Al. J iJs on! !? Al, So v».r4 ST. , AI IW•SI ,n- k-4.,[ -- /05%011 N of �� OA 9 is beat 8WO"ir.won WI CO" ° $�° ect a .--- �peva es snd ea!Vis• tn9 � tt,e '� a v+d� NO In citioN 001' IXOt litres Won s 6 .+0 Or ADDRESS i...v+ ZONE ' boditmees , ,,. '.! , ROAD WIDTH Sl�ynsd' 44.6:,_____ �^ Q� FRONT FLANKING------- COMMENTS I/ Dec REVIEWED SY APAIIINY, . t/ • la'CoVEREA 15 t6t'Af' 0 VI ‘M 4'/XZ'ri GARAGE 2L$X Ng MFG .FEON� W c , to 1 t I I I \d''."' IS# "'"1/. I I.�ib tai •• • ll , • IpS.01, 1/12 AI. £owDleA Sr. • THESE PLANS MUST ; , QRI THEB KEPT City of . , • ., SITE SPOKANE VALLEY BUILDING DEPARTMENT • 11707 E.Sprauge Avenue,#106,Spokane Valley,Washington 99206-Tel 509-921-1000-Fax 509-921-1008 QA)1/4d, kkA,thil.CLQ ,)1 }3) al ` @,,t14/7i, ebtitetmlvi 'LiNtia,Z60 glowing is a typical cross-section for a residential garage.It may or may not represent the proposed project.If you arc using this tail as a portion ofyourplan submittal,please complete the requested information in the boxes provided on both sides ofthis sheet. :ompleted sheet,along with any additional information needs to be submitted with your application and be on site at the time of pcction. ®ENGINEERED TRUSS OR, ❑RAFTER SIZE AND SPACING ( U"P1@ O.C. ROOFING MATERIAL Jrre3 7 -,'::* -,,.....,...,-- ----; )OFING PAPER 4115 MINIMUM /,c,;' Lerx7• . ••. 's . 0O SHEATHING TYPE SL 4 f�,2 � b ---�—�'� \� � SOLID BLOCKI G DOUBLE TOP PLATE STUDS . • TREATED SILL BETWEEN TRUSSES 1/2"X 9"ANCHO - )BOLTS®6'0"O,C. WALL HEIGHT &' i 3 1/2"CONCRETES • . cu ( •� .--i :.` " ,Y. 'E—2 X k• © /4, O.C. • • SIDING ,PRESSURE (2)#4 REBAR ' •ti' . 7!!`a'eVi�•i2 m0iRD . TREATED I • PLATE ANCHORBOLTS ALTERNATE FOUNDATION FOR -1 ACCESSORY BUILDINGS FROM - 1/2"X 9" 1000 SQ.FT.TO 3000 SQ.FT. 4.if MINIMUM(7" 6"min. •tt; f_ s • . )TE: (ill 1111' - 8.. CONCRETE)6' Diagonal wall bracing required on igll `.x� O.C. OR each corner and every 25 feet of wall. FOUNDAT1ONDEPTH = ' 3 1/2 APPROVED Walls within 3 feet of a property line or t/J c — " . 18 (Detached) fi I CONCRETE ANCHOR within 6 feet of a dwelling must be 1 hour 24"(Attached) �..............J SLAB INSTALLED PER rated. (5/8"type "X"gypsum sheathing on both sides of wall).Openings are not 6"X 12"FOOTING MANUFACTURER permitted in these walls.Garages over SECTION AA 3,000 sq.ft.require protection when closer than 20 feet to the property line. .— Parapets may be required. Doors entering a garage from the ' " • • : , •• • 6" min. ALTERNATE house must be 1 3/8"solid core or carry a 4''°`'ilii ' . FOUNDATION )20 minute fire rating(self-closing hinges 1 '. . • stIt�llil (DETACHEDI UNDER 1000 required). These common walls must also _— . -. Iul - 12" min. SQ. FT.) be protected on the garage side with 5/8" N 1 (2) #4 Rebar type'x' gypsum sheathing. gYe -ON H. 1' ') it/2. d. Sl,.,,,¢ • .gy vAl H. -� .t) • • FOUNDATION PLAN . • PLEASE COMPLETE THE FOLLOWING INFORMATION AND ADD ON THE DRAWING BELOW ssh4zs1!GU 1 D tt 'n''r�, 4'1/44'7 BUILDING DIMENSIONS � y��''' `^ i&C )\.,19). •i a XIS 1/-412,00,) GARAGE DOOROPENINGAND HEADERSIZE: 7 Sc/L ' r,1 S lq x 12 & rt1 � '"H $ "' INDICATE THE LOCATION AND SIZE OF ALL WINDOWS AND DOORS ON THE P •I VI. 'ih9'a�" , AlA. itiotoff.stogas *lac Line Wid 2� A _G'1,�� 3304 RidgeL/lj, cid�. 7 - -- -1 �-i l sly, • o ii il , .._ ) A A 3 ' If • c i rA L • • 1 L J ease note that while every effort is made to assure the accuracy of the information contained in this brochure it is not warranted for accuracy. uis document is not intended to address all aspects or regulatory requirements for a project and should serve as a starting point for your investiga- m. For detailed information on a particular project,permit,or code requirementrefer directly to applicable file and/or code/regulatory documents or intact the appropriate division or staff.