Loading...
2011, 02-17 Permit App: 11000338 Residence Project Number: 11000338 Inv: 1 Application Date: 2/17/2011 Page 1 of 3 THIS IS NOT A PERMIT Penalties will be assessed for commencing work without a permit Project Information: Permit Use: NEW SFR-SEWER Contact: C W CONSTRUCTION Address: 10061 BELLA RIDGE DR C-S-Z: COEUR D ALENE ID 83814 Setbacks:Front Left: Right: Rear: Phone: (208)699-7096 Group Name: Site Information: Project Name: "irwfft ' TM!%:wZ4,4 ,,". ., _ «am.:.."?".,,„'uv„#!,' Plat Key: Name: Range District: Nort Parcel Number: 45173.2403 Block: Lot: SiteAddress: 9808 E SPRINGFIELD LN Owner:Name: WILHELM,JAY Address: PO BOX 425 Location::CSV NEWMAN LAKE,WA 99025 Zoning: R-3 SF Res District Water District: 011 MODERN Hold: ❑ Area: 6,328 Sq Ft Width: 0 Depth: 0 Right Of Way(ft): 0 Nbr of Bldgs: 0 Nbr of Dwellings: 0 Review Information: .. .: Review Building Plan Review Released By: — — ', Originally Released: 2/14/2011 By: tmelbourn Landuse/Zoning/HE Conditions Released By: with conditions to pave driveway. Originally Released: 2/17/2011 By: lbarlow, Sewer Review Released By: _Originally Released: 2/11/2011 By: JLMain Permits: aaperato.: ,mrn Printed By: jmm Print Date: 2/17/2011 Project Number: ,11000338 Inv: 1 Application Date: 2/17/2011 Page 2 of 3 THIS IS NOT A PERMIT Penalties will be assessed for commencing work without a permit Building Permit Contractor: C W CONSTRUCTION Firm: C W CONSTRUCTION Address: 10061 BELLA RIDGE DDR Phone: (208)699-7096 COEUR D'ALENE ID 83814 This Application: Total Project: Description Grp Type Notes Sq Ft Valuation Sq Ft Valuation 1&2 FAMILY R-3 VB 520 $52,494.00 520 $52,494.00 2ND FLOOR R-3 VB 1,133 $84,079.93 1,133 $84,079.93 DECK OPEN R-3 VB 126 $1,890.00 126 $1,890.00 GAR WOOD U-1 VB 520 $9,880.00 520 $9,880.00 Totals: 2,299 $148,343.93 2,299 $148,343.93 Item Description Units Unit Desc Fee Amount RESIDENTIAL PERMIT FEE 1 SELECT $1,268.15 WSBCC SURCHARGE 1 SELECT $4.50 SF PLNS RVW<7999 SQ FT 1 SELECT $507.26 SFR/UUP SITE PLN REVIEW 1 SELECT $50.00 Permit Total Fees: $1,829.91 Mechanical Permit Contractor: C W CONSTRUCTION Firm: C W CONSTRUCTION Address: 10061 BELLA RIDGE DDR Phone: (208)699-7096 COEUR D'ALENE ID 83814 Item Description Units Unit Desc Fee Amount GAS WATER HEATER 1 NUMBER OF $11.00 GAS PIPING 2 #OF UNITS $2.00 • VENTILATING FANS 1 DUCT 4 NUMBER OF $44.00 CLOTHES DRYER 1 NUMBER OF $10.00 RANGE 1 NUMBER OF $10.00 Permit Total Fees: $77.00 Operator: jmm Printed By: jmm Print Date: 2/17/2011 Project Number: ,11000338 Inv: I Application Date: 2/17/2011 Page 3 of 3 THIS IS NOT A PERMIT Penalties will be assessed for commencing work without a permit Plumbing Permit Contractor: C W CONSTRUCTION Firm: C W CONSTRUCTION Address: 10061 BELLA RIDGE DDR Phone: (208)699-7096 COEUR D'ALENE ID 83814 Item Description Units Unit Desc Fee Amount TOILETSBIDETS 3 NUMBER OF $18.00 SHOWERS 1 NUMBER OF $6.00 TUBS 2 NUMBER OF $12.00 DISH WASHERS 1 NUMBER OF $6.00 GARBAGE DISPOSAL 1 NUMBER OF $6.00 CLOTHES WASHER 1 NUMBER OF $6.00 FLOOR DRAINS 1 NUMBER OF $6.00 MISCELLANEOUS FIXTURES 1 NUMBER OF $6.00 , Permit Total Fees: $66.00 The driveway must be hardpaved. The minimum dimensions of the hardpaving are 17'X 20'. FOR 212 N LOCUST,214 N LOCUST&216 N LOCUST(SHP-12-06),A,;6-FOOT HIGH SIGHT OBSCURING FENCE,WALL OR LANDSCAPING MUST BE INSTALLED ON THE NORTH, SOUTH AND EAST PROPERTY LINE PRIOR TO ANY BUILDINGPERMITS. Payment Summary: .00.6,044— .. a0, ._ .00.&m,4 0 ._. _ ..'.0 r4,0 1,, 00 ...,.. Permit Type Fee Amount Invoice Amount Amount Paid Amount Owing Building Permit $1,829.91 $1,829.9.1 $509.50 $1,320.41 Mechanical Permit $77.00 $77.00 $0.00 $77.00 Plumbing Permit $66.00 $66.00 $0.00 $66.00 $1,972.91 $1,972.91 $509.50 $1,463.41 Disclaimer: • Submittal of this application certifies the owner(or person(s)authorized by the owner)has both examined and finds the information contained within to be true and correct,and agrees that all provisions of laws and/or regulations governing this type of work will be complied with. Subsequent issuance of a permit shall net be construed to be a permit for,or an approval of,any violation of any of the provisions of the code or of any other state or local laws or ordinances. Signature: Operator: jmm Printed By: jmm Print Date: 2/17/2011 Community Develo ment Deia1 EIV (S aff Use Only) ,. Permit Center (:�� r ERMIT .r' JT R - 11703 East Sprag Avenue, suite B-3 �i—ERMIT N MBER: A ritTYOF � Spokane Valley, W 99206 ►�J Okalle Tel: (509) 688-00 6 ', PERMIT F E: Fax: (509) 688-00 Project# r JJJ Valley r17ii�i oermitcenterPspo i evallev.or'i . gO Submittal# RESIDENTIAL CONSTRUCTION PERMIT APPLICATION xi NEW CONSTRUCTION 0 ADDITION/REMODEL 0 ACCESSORY BUILDING 0 DECK / 0 OTHER SITE ADDRESS: 000 v SpRiNc_ DIEL-D LANt ASSESSORS PARCEL NO.: 45 1'13 . Z4o ' LEGAL DESCRIPTION: Lc7r / cpit/r(rvFw INl. BUILDING OWNER NAME: NAME: ADDRESS: CITY: STATE: ZIP: PHONE: FAX: CELL: CONTACT NAME: PHONE: FAX: CELL: CONTRACTOR NAME: 7Z(5 kAiitf(EGrvl d .b.0,. CAN (A sTri-0 (--rroPv MAILING ADDRESS:/ I VOW� 13C1-(-A W 1 DL7E P R IV CITY: ✓LEIJR 2 JL [` STATE: I pAA0 ZIP: 03c3 (4 PHONE: 2-Os -( i ---7°(O `•f �j FAX: 7.--00 -7-10 —3olo3cELL: CONTRACTOR LICENSE NO.: ONC/ON AIOVILXPIRES: Cp./Pito/2- CITY BUSINESS LICENSE NO.:T1O5(03&06US DESCRIBE THE SCOPE OF WORK IN DETAIL AND INDICATE USE & PROPOSED USE: NEW , 1?l=cfDENT1A-L SiN LE �r4n jLy 140 w,-E- 'fa 6E c_pN 'FD STx 7oiv ge06 E. Sm,'v T FiEz1 Liv. ****YOU MUST COMPLETE THE FOLLOWING**** MARK N/A IF NOT APPLICABLE Height to Peak: / Dimensions: • No. of Stories: Total Habitable Z� Zoo )'1O Z Space: fic.5 3 Main Floor S T: Upper Floor SQ FT: Unfinis d Basement SQ Finished Basement SQ V-VL WDSF 6 C2—,11.705F FT: FT: Garage SQ FT: Deck/ ver d Patio SQ Impervious Surface 30%/ Slopes on 52-0 5f A(L FT: S F Area: Property: 0 No. of Bedrooms: 3 Construction Type: NEW Heat Source:(7f}S Sewer or Septic:sifleitSaUER TOTAL COST OF PROJECT: $ DISCLAIMER 0 O -(k.J cad The permitted verifies, acknowledges and agrees by their signature that: 1) if this permit is for construction c a p f F1 C.1 be served by potable water. 2) Ownership of this City of Spokane Valley permit inure to the property owner Q t owner or has permission to represent the property owner in this transaction. 4) All construction is to be done ,02„M,,r Spokane Valley Development code. Referenced codes are available for review at the City of Spokane Vail Spokane Valley permit is not . permit or approval or any violation of federal, state or local laws, codes or a information may be require."t' be_ubmitted a •e ubsequently approved before this application can be process �itj "1 d� ` / 14 /Tob 1 Signature i Date: Updated 1-11-11 Page 1 of 1 http://www.spoka nevalley.org/filestorage/124/938/210/948/1496/Building_Permit_-_Residential_11-11-11.doc RESIDENTIAL CHECK LIST DIRECTIONS: Place a check mark in box next to each document required for complete submittal. ❑ SITE PLAN ❑ Property lines and dimensions ❑ Setbacks to property lines ❑ Direction arrow pointing North and orientation to streets ❑ Distance between buildings ❑ Proposed/existing buildings (footprint and dimensions) ❑ Right of way/easement location &sizes ❑ Utilities, septic tank/drain field locations and distances ❑ Driveway approach size and location BUILDING PLANS (3 SETS) (minimum 1/8 inch scale or completely dimensioned) ❑ Elevations (Front/Rear/Sides)with roof peak and wall height including basement: ❑ Foundation Plan (crawlspace, basement or slab on grade): ❑ Footing sizes and locations ❑ Supporting wood cripple walls or beams ❑ Perimeter concrete foundation wall sizes ❑ Thickened concrete pads supporting ❑ Crawlspace ventilation beams or girder trusses ❑ Floor Plan of each level (finished or unfinished)with dimensions: ❑ Floor Joist direction, size and spacing ❑Window and door location and sizes ❑ Header, beam or concrete lintel sizes ❑Window well locations if applicable ❑ Brace wall panel locations ❑ Room usage labels ❑Water heater and furnace locations ❑ Smoke detector locations ❑ Exhaust fan locations ❑ Attic and crawl space access locations ❑ Deck or concrete patio sizes and locations ❑ Fire Wall construction ❑ Roof Plan: ❑ Engineered truss direction and spacing ❑ Ridge, eave and valley lines ❑ Rafter and over frame direction, size and spacing ❑ Beam and girder size and location ❑ Wall Section Detail including: Roof ❑ Slope/roofing material/underlayment/ice dam protection ❑ Truss or rafter size, spacing &connection ❑ Sheathing size and type ❑ Attic insulation/air space baffle/ventilation Ceiling ❑ Joist size and spacing ❑ Size of ceiling gypsum wall board Wall ❑ Height/top plate/stud size and spacing/sole plate ❑ Siding/exterior house wrap/anchor bolts ❑ Exterior sheathing size and type ❑ Insulation, vapor barrier, gypsum wall board Floor ❑ Joist size and spacing ❑ Sheathing or concrete floor size/insulation Foundation Wall ❑ Concrete or Masonry unit width ❑ Footing bottom to finished ground level depth ❑ Earth to wood separation distance ❑ Horizontal &vertical reinforcement if any Footing ❑ Size ❑ Reinforcement if any Radon ❑ Passive system with 6mil vapor barrier ❑Active system with 6 mil vapor barrier Miscellaneous Construction Details ❑ Deck: ❑ Floor plan/side view/dimensions ❑ Footings/post/and beam size and locations ❑ Floor Joist/decking direction, size and spacing ❑ Stairway tread rise& run and nosing ❑ Handrail/Guard height&spacing Community Development Department Permit Center (Staff Use Only) ` . ' S IT C * 11703 East Sprague Avenue,Suite B-3 PERMIT NUMBER: ss�� Spokane Valley,WA 99206 i. ler Tel: (509) 688-0036 PERMIT FEE: Fax: (509) 688-0037 40000 permitcenter@ispokanevallev.org APPROACH PERMIT APPLICATION PROJECT ADDRESS: QC70j E. SARIN(.�.�/FL12 L*rvE START DATE: 2... / 11- u/ ANTICIPATED COMPLETION DATE: (0//5/// BUILDING OWNER NAME: MAILING ADDRESS: CITY: STATE: ZIP: CONTACT PERSON NAME: PHONE: FAX: CELL: CONTRACTOR NAME: ("1\1 bONS ✓C770A/ MAILING ADDRESS: (OD(&( 13ELLA gDOE DR CITY: (/oEUf? 1, /ILi NE STATE: 7)4440 ZIP: t3,38 1 PHONE: k e -YJ [ i -7 ''AA,,/(0 FAX: 7 of - VI 3b6 3 CELL: 2 Q CONTRACTOR LICENSE No.: �jINtoNwGgZILCEXPIRES: CITY BUSINESS LICENSE NO.:III 05 036SB US PROJECT DESCRIPTION (Please Provide Site Sketch) NI Residential Driveway 0Commercial/Industrial Driveway 0 Existing Curb &Gutter 0I Rural Road Section Culvert Installation El Sidewalk Repair/Construction Di Other Conditions: • • Bond/Insurance certification must be On file with the City. DISCLAIMER The permitted verifies,acknowledges and agrees by their signature that: 1)if this permit is for construction or on a dwelling,the dwelling is/will be served by potable water. 2) Ownership of this City of Spokane Valley permit inure to the property owner. 3) The signatory is the property owner or has permission to represent the property owner in this transaction. 4) All construction is to be done In full compliance with the City of Spokane Valley Development code. Referenced codes re available for review at the City of Spokane Valley Permit Center. 5) The City of Spokane Valley permit Is not a permit r approval for ny violation of federal, state or local laws, codes or ordinances. 6) Plans or additional Information may be required . .e su mitted and su quently approved before this application can be processed. / / , Signature /(/' Date: -7///// el , Updated 1-11-11 Page 1 of 1 http://www.spokaneva Iley.org/filestorage/124/938/210/948/1496/Approach_Permit_1-11-11.doc APPROACH PERMIT APPLICATION • ' REQUIRED SKETCH INFORMATION (Revised 1/25/10) Provide required measurements (in sketch boxes), and include street name. Check all existing conditions that apply: ❑ Sidewalk ❑ Drainage Ditch ft wide 0 Drywell (show location on sketch) ft from back of curb 0 Other (please describe below) 0 Streetside Swale L'� DISTANCE FROM L'I NEAREST PROPERTY LINE IMAY BE LEFT OR RIGHT SIDE) Li FT(SEE TABLE) w a / \ 7 cei a; ' , CONCRETE CURB APPROACH RETURN 'WN THROAT WIDTH TABIFT WING I- CURB IF CORNER LOT, DISTANCE FROM STREET NAME CURB RETURN n FT(SEE TABLE) STREET WITH CURB w I DISTANCE FROM D I- - NEAREST PROPERTY LINE MAY BE LEFT OR RIGHT SIDE) �i FT(SEE TABLE) w cL cc ASPHALT 15'RADIUS RADIUS al APPROACH RETURN ------------ EDGE OF I---THROAT WIDTH nFT----1I ASPHALT (SEE TABLE) �IF CORNER LOT, DISTANCE FROM STREET NAME RADIUS RETURN =FT(SEE TABLE) STREET WITH ASPHALT EDGE Approach Requirements: • Maximum 2 approaches per property frontage; one on arterials. • Total width of approaches not to exceed 50%of frontage width. Residential Approaches Commercial Approaches Distance from Curb/Radius Return 15'minimum 75'minimum Separation between Approaches (measured See Page 7-27 from centerline to centerline of each None specified in City Street Standards approach) Throat Width (flat portion) 16'min., 30'max. 30'min., 40'max. Wing Width (at curb line) 4 feet typical 4 feet typical Minimum Distance from Side Property Line (@ r/w) 5.0' 5.0' Minimum Distance from Crosswalk 5' 5' Permit Center °` el 11703 E Sprague Ave,Suite B-3 PERMIT NUMBER: Vd Spokane Valley,WA 99206 (509)688-0036 FAX:(509)688-0037 PERMIT FEE: Community Development www.spokanevalley.org Plumbing Permit Application 111Commercial r5<1 Residential SITE ADDRESS: 41 SOP, S r zt N(1 f IELD LANE Building Owner Name: Phone: Fax: Address: City: State: Zip: Contractor ,4J ppt S1J j 1-Ti ON Name: (" IS wIL L/1/1 Phone: Zz —(o19_7Dq Fax: 2,78 -30(03 Address: l 00 Co I (3E.LLA R(OC E DR City: &DEV? D ALINE State: D Zip: 83$3/4 License No: ems/COIJLC- City Business Lic: �(o5( 306 vVS Contact �q Name: � f5 V v x Phone: 2 Dg —4CIG� DESCRIPTION OF WORK #OF UNITS X COST = TOTAL AMOUNT 1 TOILETS WATER CLOSET,BIDETS J X $6.00 = 2 URINALS X $6.00 = 3 TUBS 2- X $6.00 4 SHOWERS(PER TRAP) BATH,STALL,ON-SITE BUILT I X $6.00 LAYS/BASINS,BAR,FLOOR,KITCHEN, 5 SINKS LAUNDRY,UTILITY,JANITOR,PHOTO, X $6.00 = X-RAY,FOOD,PREP/CULINARY MEAT 6 DISHWASHER I X $6.00 = 7 CLOTHES WASHER X $6.00 = 8 GARBAGE DISPOSAL I X $6.00 = 9 WATER SOFTENER X $6.00 = 10 ELECTRIC WATER HEATER NOTE: IF GAS,SEE MECHANICAL X $6.00 = AREA,CASE,COIL,TRENCH, 11 FLOOR DRAINS CONDENSATE X $6.00 = 12 ROOF DRAINS/OVERFLOW DRAINS X $6.00 = 13 FOUNTAINS,DRINKING X $6.00 = WATER PIPING/DRAIN-IN WASTE, NSTALLATION,ALTERATION,REPAIR, 14 VENT,PLUMBING,REVERSAL REVERSALS X $6.00 = 15 SEWAGE EJECTOR GRINDER,SUMP PUMP X $6.00 ICE AN/OR COFFEE MAKER,HOSE BIB, 16 WATER USING DEVICE STEAMER X $6.00 = PROOFER,CARBONATOR,SWAMP COOLER VACUUM BREAKER,CHECK VALVE, AND R.P.B.P.D.FOR: VATS,TANKS, 17 CROSS CONNECTION DEVICE BOILERS X $6.00 = GREASE TRAP,SAND TRAP, 18 INTERCEPTORS CHEMICAL HOLDING TANK X $6.00 = 19 MEDICAL GAS(per outlet) NITROUS,OXYGEN X $6.00 20 MISCELLANEOUS PLUMBING FIXTURE X $6.00 = 21 PRIVATE SEWAGE DISPOSAUSYS X $20.00 = 22 INDUSTRIAL WASTE INTERCEPTOR X $15.00 = SUBTOTAL METHOD OF PAYMENT: PROCESSING FEE ❑CASH 0 CHECK 0 VISA ❑MC EXPIRES: $35.00 Card# VIN: TOTAL PERMIT FEE DUE: AUTHORIZED SIGNATURE: REVISED 8/26/05 Permit Center 1 1170703 E Sprague Ave,Suite B-3 PERMIT NUMBER: ►�j�� Spokane Valley,WA 99206 j�` (509)688-0036 FAX:(509)688-0037 Community Development www.spokanevalley.org PERMIT FEE: Mechanical Permit Application n Commercial 151 Residential SITE ADDRESS: loos SeR(No 1 ,EL 17 Lf14E Building Owner Name: Phone: Fax: Address: City: State: Zip: Contractor G W CONSTRocr oN Name: C I S W I LtiEL m Phone: Z a e-(,q' -701(0 Fax: 7 05 -jig -30G,3 Address: t Dn(a f ig,£LGA tzfp6E Pe- City: LnEvi vALEA,E State: /D Zip: b38 r4 License No: (ANI Co NI W C- et Z 1 L City Business Lic: ,r i`0 5(,,S(0 g liNS Contact / Name: ( ft r /15 I Lel E L M Phone: 2 v - (o lei 7 0( 1 , DESCRIPTION OF WORK #OF UNITS X COST = TOTAL AMOUNT 1 FUEL BURNING APPLIANCE Equal to or less than 100,000 X $12.00 = 2 FUEL BURNING APPLIANCE More than 100,000 X $15.00 = 3 UNLISTED APPLIANCE(Additional Fee) Equal to or less than 400,000 X $50.00 = 4 UNLISTED APPLIANCE(Additional Fee) More than 400,000 X $100.00 = 5 USED APPLIANCE(WSEC min.AFUE rating) Equal to or less than 400,000 X $50.00 = 6 USED APPLIANCE SEC min.AFUE ratin ) More than 400,000 X $100.00 = 7 BOILER/REFRIGERATION 1-100M BTU X $12.00 = 8 BOILER/REFRIGERATION 101-500M BTU X $20.00 = 9 BOILER/REFRIGERATION 501-1,000M BTU X $25.00 = 10 BOILER/REFRIGERATION 1,001 -1,750M BTU X $35.00 = 11 BOILER/REFRIGERATION More than 1,750M BTU X $60.00 = 12 GAS LOG,GAS INSERT,GAS FIREPLACE X $10.00 = 13 RANGE I X $10.00 = 14 DRYER I X $10.00 = 15 FUEL BURNING WATER HEATER 1 X $10.00 = 16 MISC.FUEL BURNING APPLIANCE X $10.00 = 17 GAS PIPING(each outlet) 7. - X $1.00 = 18 DUCT SYSTEMS _ X $10.00 = 19 VENTILATING FANS 0�' 5 X $10.00 = 20 AIR HANDLER(DOES NOT include ducting) Equal to or less than 10,000 CFM X $12.00 = 21 AIR HANDLER(DOES NOT include ducting) Greater than 10,000 CFM X $15.00 = 22 EVAPORATIVE COOLERS X $10.00 = 23 TYPE I HOOD X $50.00 = 24 TYPE II HOOD X $10.00 = 25 HEAT PUMP/AIR CONDITIONER 0-3 TON X $12.00 = 26 AIR CONDITIONER 4-15 TON X $20.00 = 27 AIR CONDITIONER 15-30 TON X $25.00 = 28 AIR CONDITIONER 30-50 TON X $35.00 = 29 AIR CONDITIONER More than 50 TON X $60.00 = 30 LPG STORAGE TANK X $10.00 = 31 WOOD OR PELLET STOVE/INSERT X $10.00 = 32 WOOD STOVE-FREE STANDING X $25.00 = 33 REPAIR&ADDITIONS X $15.00 = 34 VENTILATION SYSTEMS X $12.00 = 35 VENTILATION MECHANICAL EXHAUST X $12.00 = 36 INCINERATOR-RESIDENCE X $19.00 = 37 INCINERATOR-COMMERCIAL X $22.00 = METHOD OF PAYMENT: SUBTOTAL ❑CASH 0 CHECK 0 VISA 0 MC EXPIRES: PROCESSING FEE $35.00 CARD#: VIN: TOTAL PERMIT FEE DUE: AUTHORIZED SIGNATURE: REVISED 8/26/05 Washington State Energy Code:Component Performance Worksheet,Type R-3 Occupancies Wilhelm Heating System Size Ducts are located in unconditioned space❑ Conditioned Floor Area 1519 Equipment size over design load 150% . Conditioned Building Volume 12152 Btu/hour output 41,687 Weather Station Spokane AP • KW 12.2 Component Performance,R-3 occupancies Code Target Values Proposed Design Values Area UA Area UA Vertical Glazing U= 0.300 228 68.4 217 75.8 Overhead Glazing U= 0.500 0 0.0 0 0.0 Doors U= 0.200 41 8.1 41 6.5 FlatA/aulted Ceilings U= 0.027 1045 28.2 1045 32.4 Wall(above grade) U= 0.056 1508 84.4 1519 86.6 Floors U= 0.029 487 14.1 487 24.8 Slab on Grade F= 0.360 91 32.8 91 49.1 Below Grade 2'depth,wall U 0.042 0 0.0 0 0.0 2'depth,slab F= 0.590 0 0.0 0 0.0 3.5'depth,wall U 0.041 0 0.0 0 0.0 3.5'depth,slab F= 0.640 0 0.0 0 0.0 7'depth,wall U= 0.037 0 0.0 0 0.0 7'depth,slab F= 0.570 0 0.0 0 0.0 Target UA Total 236.0 Proposed UA Total 275.2 Target Credits from Chpt.9 1.0 Proposed Credits from Chpt. 9 0.0 If the Proposed UA<_the Target UA, and the Proposed Credits From Chpt.9 are z 1 than the home meets the 2009 WSEC. Check other code requirements Copyright 2010,WSUEEP10-009(Version 10)Copied by permission from Washington State University Extension Energy Program. (see copyright restrictions) 2/11/2011 1 of 6 1 Washington State Energy Code:Component Performance Worksheet,Type R-3 Occupancies . Vertical Glazing Plan Component Glazing Width Height ID Description _ Ref. U Qt. Feet I"°" Feet i"cn. Area UA 2g1 Wood/vinyl,Low-el 1/2"+argon v 10-6B 0.350 2 10 42 5.8 2.0 2gl Wood/vinyl,Low-el 1/2"+argon V 10-66 0.350 2 10 72 10.0 3.5 2g1 Wood/vinyl,Low-el 1/2'+argon NY10-6B 0.350 1 30 42 _ - 8.8 3.1 2g1 Wood/vinyl,Low-el 1/2"+argon v 10-6B 0.350 1 48 60 20.0 7.0 2gl Wood/vinyl,Low-el 1/2"+argon V 10-6B 0.350 3 60 48` 60.0 21.0 2g1 Wood/vinyl,Low-el 1/2"+argon V 10-6B 0.350 1 24366.0 2.1 2gl Wood/vinyl,Low-el 1/2"+argon V 10-6B 0.350 1 72 72 36.0 12.6 2g1 Wood/vinyl,Low-el 1/2"+argon V 10-6B 0.350 1 36 42 40:5 3.7 2g1 Wood/vinyl,Low-el 1/2"+argon v 1Q-6B 0.350 1 24 36 6,0 2.1 2g1 Wood/vinyl,Low-el 1/2"+argon V 10-6B 0.350 1 60 42 17.5 6.1 2g1 Wood/vinyl,Low-el 1/2"+argon v 10-6B 0.350 1 72 72 ' 36.0 12.6 v 0 0.000 0.0 0.0 V 0 0.000. 0.0 0.0 V 0 0.000 0.0 0.0 V 0 0.000 0.0 0.0 V 0 0.000 0.0 0.0 V 0 0.000 0.0 0.0 V 0 0.000 0.0 0.0 V 0 0.000 0.0 0.0 V 0 0.000 0.0 0.0 V 0 0.000 0.0 0.0 V 0 0.000 0.0 0.0 v 0 0.000 0.0 0.0 V 0 0.000 0.0 0.0 0 0.000 0.0 0.0 0 0.000 0.0 0.0 V 0 0.000 0.0 0.0 V 0 0.000 0.0 0.0 0 0.000 0.0 0.0 0 0.000 0.0 0.0 0 0.000 0.0 0.0 V 0 0.000 0.0 0.0 V 0 0.000 0.0 0.0 0 0.000 0.0 0.0 0 0.000 0.0 0.0 Iv 0 0.000 0.0 0.0 0 0.000 0.0 0.0 V 0 0.000 0.0 0.0 0 0.000 0.0 0.0 V 0 0.000 0.0 0.0 V 0 0.000 0.0 0.0 V 0 0.000 0.0 0.0 V 0 0.000 0.0 0.0 Iv 0 0.000 0.0 0.0 0 0.000 0.0 0.0 Copyright 2010,WSUEEP10-009(Version 10)Copied by permission from Washington State University Extension Energy Program. (see copyright restrictions) 2/11/2011 2 of 6 Washington State Energy Code:Component Performance Worksheet,Type R-3 Occupancies Overhead Glazing: Plan Component Glazing Width Height ID Description Ref. U Qt. Feet " ' Feet Inch Area UA v 0 0.000 0.0 0.0 v 0 0.000 0.0 0.0 v 0` 0,000' 0.0 0.0 V 0 0.000 0.0 0.0 v 0 0.000 0.0 0.0 v 0 0.000 0.0 0.0 V 0 0.000 0.0 0.0 Sum of Area and UA 0.0 0.0 FlatNaulted Ceilings Plan Component Attic ID Description Ref. U Area UA R38 blown Attic STD baffled V 10-7 0.031 1045.0 32.4 v 0 0.000 0.0 V 0 0.000 0.0 V 0 0.000 0.0 Sum of Area and UA 1045.0 32.4 Copyright 2010,WSUEEPIO-009(Version 10)Copied by permission from Washington State University Extension Energy Program. (see copyright restrictions) 2/11/2011 4 of 6 Washington State Energy Code: Component Performance Worksheet,Type R-3 Occupancies V 0 0.000 0.0 0.0 v 0 0.000 0,0 0.0 V 0` 0.000 0.0 0.0 v 0 0.000 0.0 0.0 V 0 0.000 0.0 0.0 v 0 0,000 00 0.0 V 0 0.000 0.0 0.0 Sum of Area and UA ` 216.6 75.8 Glazing Area Weighted U 0.350 Exterior Doors Plan Component Door Width Height ID Description Ref. U Qt. Feet 1nen Feet "`h Area UA 1 Exempt Door if less than 24 SF #N/A NA 1 36 81 20.3 Insulated Steel,Wood Edge(ISteeIWE) V 10-6C 0.160 1 36 81 20.3 3.2 InsOtated-Stee, -- �n 6C 0 160 1 as A' 20.3 3.2 V 0 0.000 0.0 0.0 V 0 0.000 0.0 0.0 V 0 0.000 0.0 0.0 V 0 0.000 ' 0.0 0.0 V 0 0.000 . 0.0 0.0 V 0 0.000 0.0 0.0 v 0 0.000 0.0 0.0 v 0 0.000 0.0 0.0 If exempt door is selected, must be s 24 SF. Sum of Area and UA 40.5 6.5 Copyright 2010,WSUEEP10-009(Version 10)Copied by permission from Washington State University Extension Energy Program. (see copyright restrictions) 2/11/2011 3 of 6 Washington State Energy Code:Component Performance Worksheet,Type R-3 Occupancies Walls(Above Grade) Plan Component Wall ID Description Ref. U Net Area UA R21 cavity+RO foam STD 2X6W Lap V 10-5 0.057 1519.0 86.6 v 0 0.000 0.0 V 0 0.000 0.0 v 0 0.000 0.0 v 0 0.000 0.0 v 0 0.000 0.0 0 0.000 0.0 V 0 0;000 0.0 v 0 0.000 0.0 v 0 0.000 0.0 v 0 ' 0.000 0.0 . 0 0.000 0.0 0 0.000 0.0 Sum of Net Wall Area and UA 1519.0 86.6 Floor(over crawl or exterior) Plan Component Floor ID Descr!ption Ref. U Area UA R30 Wood Joist Exposed V 10-4A 0.051 487.0 24.8 - 0 0.000 0.0 V 0 0.000 0.0 V 0 0.000 0.0 Sum of Area and UA 487.0 24.8 Slab on Grade(less than 2 feet below grade) Plan Component Slab Slab ID Description Ref. F Length UA R10 2'vertical V 10-2 0.540 91.0 49.1 0 0.000 0.0 v 0 0.000 0.0 V 0 0.000 0.0 Sum of Area and UA 91.0 49.1 Copyright 2010,WSUEEPIO-009(Version 10)Copied by permission from Washington State University Extension Energy Program. (see copyright restrictions) 2/11/2011 5 of 6 Washington State Energy Code:Component Performance Worksheet,Type R-3 Occupancies Below Grade Wall:2 foot depth Plan Component Wall Wall Wall Slab Slab Slab ID Description Ref. U Area UA F Length UA CI 0 0.000 0.0 0.000 0.0 0 0 0.000 0.0 0.000 0.0 CI 0 0.000 0.0 0.000 0.0 0 0 0.000 0.0 0.000 0.0 Sum of Area, Length and UA 0.0' 0.0 0.0 0.0 Below Grade Wall:3.5 foot depth. Plan Component Wall Wall Wall Slab Slab Slab ID Description Ref. U Area UA F Length UA v 0 0.000 0.0 ` 0.000 0.0 v 0 0.000 0.0 0.000 0.0 V 0 0.000 0.0 0.000 0.0 v 0 0.000 0.0 0.000 0.0 Sum of Area, Length and UA 0.0 0.0 0.0 0.0 Below Grade Wall:'7 foot depth Plan Component Wall Wall Wall Slab Slab Slab ID Description Ref. U Area UA F Length UA V 0 0.000 0.0 0.000 0.0 v 0 0.000 0.0 0.000 0.0 V 0 0.000 0.0 0.000 0.0 V 0 0.000 0.0 0.000 0.0 Sum of Area, Length and UA 0.0 0.0 0.0 0.0 Chapter 9 Options Total of 1 Credit Required Opt. Opt. Description 1a High Efficiency HVAC Equipment 1 ❑ lb High Efficiency HVAC Equipment 2 ❑, 1c High Efficiency HVAC Equipment 3 ❑ 2 High Efficiency HVAC Distribution System ❑ 3a Efficient Building Envelope 1 ❑ 3b Efficient Building Envelope 2 ❑ 3c Super-Efficient Building Envelope 3 ❑ 4a Air Leakage Control and Efficient Ventilation ❑' 4b Additional Air Leakage Control and Efficient Ventilation ❑ 5a Efficient Water Heating ❑, 5b High Effieciency Water Heating ❑ 6 Small Dwelling Unit ❑ 7 Large Dwelling Unit [] 8 Renewable Electric Energy CI *1200 kwh 0.0 Total Credits 0.00 Copyright 2010,WSUEEP10-009(Version 10)Copied by permission from Washington State University Extension Energy Program. (see copyright restrictions) 2/11/2011 6 of 6 58 . , (.o,3z8 sF DE !O 40' q Li) ,s t 802_ 0' uTILITY DRAINIAc7E - — - - - - - - - - - - - - EASEMENT /13 • _35 E. S vR,N CIFIEu LN. : RECEIVED APPROVED BY �- �'� - '1�, c)CI�t�tiy� r CSV PERMIT CENTER al«I 1,1 FEB t1 oii Project# II— O Nolle_ Submittal For City Use Only PLUS Project Number ..:78 SiÔkane Project Address /'(c{Ute Y k4000 �}-��s q ; allevy® 11703 E Sprague Ave Suite B-3 • Spokane Valley WA 99206 509.688.0036 • Fax: 509.688.0037 ♦ permitcenter@spokanevalley.org As part of our on-going commitment to customer service during the review process of your project application, we are providing you with a TARGET DATE for the initial technical application review. If for any reason we cannot meet this date, we will contact you with a revised target date. Your application review TARGET DATE is The TARGET DATE is the date we estimate your project application will have had its initial technical review. It is not the date for approval or permit issuance. Tips for a Smoother Project Application Review ➢ Submit complete, accurate plans and documents. Extra time may be required for re-submittals as project application reviewers work on multiple applications and it may be several days before they can look at your new or revised information. ' Designate a specific contact person to communicate with the City. While the person designated as the applicant's contact person with the City can be changed, one individual with the expertise for dealing with reviewer comments would be the best choice for the entire review process. ➢ Call staff regarding the status of your project only after the target date shown at the top of the page. Although you should be contacted on or by the target date,please feel free to contact us if you haven't heard from us by your target date. Staff may contact you before the target date if the initial review is complete. By following this procedure,you will save time and allow the reviewers to complete the work more expeditiously. Steps in the Permit Process 1. Counter Complete. Your application has been accepted as counter complete. This means all of the required documents, as indicated on your Pre-Application Checklist have been submitted or have been approved for deferred submittal. This does not prevent technical staff from requesting additional information as a result of their technical review. 2. Quality Check. The next step in the process is a quality check to make sure that the application is reviewable and free from substantive flaws that would prevent technical staff from completing the technical review once it is started. When this step is complete, your application will be routed to the appropriate staff and remain in their review queue until it comes up for review. 3. Technical Compliance. Once an application is administratively complete, it is routed to technical staff for compliance review. Depending on the type of project, technical staff may include multiple reviewers. You should be contacted by phone,fax, email,or mail by your TARGET DATE once the initial technical compliance review is complete. 4. Permit Issuance. When the technical compliance review of the application is complete, including any subsequent re- submittals, each reviewer will approve their section of the application and route it to the Permit Center. When all sections of the application are received, a Permit Specialist will process the application and contact the person specified on your application for permit pick-up. Information regarding fees and pre-construction meetings (if required) will be provided by the Permit Specialist at that time. WHITE-APPLICANT PINK-BUILDING FILE REV 9/07