Loading...
2014, 09-09 Energy Compliance CertificateVB 320 Property Address: 426 S St Charles Spokane Valley, WP Conditioned Floor Area: 1650 Date: 09 / 09 / 2014 Builder or registered design professional : Viking Builders Home Energy Audit Tech Signature: Ale Mown 509 280 0381 R -Values Ceiling: Vaulted R- Floors: Over unconditioned space R - Attic R- 49 Slab on grade floor R- 10 Walls: Above grade R- 21 Doors: Metal R- 5.6 Below, int. R- Glazed R- 3.3 Below, ext. R- R- U -Factors and SHGC NFRC rating (or) Windows U .30 Default rating (Appendix A wsEC 2012) Skylights U- SHGC- N/A SHGC- N/A Table 406.2 Option(s) 5B Total 406.2 Credits 1.5 Heating, Cooling & Domestic Hot Water System Type Efficiency Heating Gas forced air 95.2% Cooling Electric central DHW Electric heat pump 50 gal 2.4 EF Duct & Building Air Leakage All ducts & HVAC in conditioned space ( yes /n) Insulation R- 8 Air handler present (ycs /xsto Test Target 66 CFM(a 25Pa Test Result 61 CFM(d,.25Pa Building air leakage target: ACHS,) < 5.0 - Tested leakage: ACI -i50= 5-, o Onsite Renewable Energy Electric Power System System type: Rated annual generation Kwh