HomeMy WebLinkAbout2014, 03-27 Energy Compliance CertificateWilMJAYPI
Property Address: 501 S St Charles Spokane Valley
Conditioned Floor Area: 2494 Date: 03 / 27/ 2014
Builder or registered design professional :
Viking Builders
Home Energy Audit Tech
Signature: h(leQBtown 509 280 0381
R-6 aloes
Ceiling: Vaulted R- Hones: Over unconditioned space R- 3 0
Attic R- 49 Slab on grade floor R- / t
\Valls: Above grade R- 21 Doors: Metal
Below, int, R -
Below, ext, R- R-
R- 5.3
Glazed R- 3.3
U -factors and SHGC
NERC rating(or) Windows U- .30 SIIGC- N/A
❑ciiult rating (areeidis A WSW 2012)
Skylights LJ- SHGC- N/A
Table 406.2 Option(s) 5B
Total 406.2 Credits 1.5
Heating, Gaoling & Domestic Hot Nater
System
Type
Efficiency
Heating
Gas forced air
92.1%
Cooling
Electric central
13 c t-Lv`d
Dl I W
Electric heat pump 60 gal
2.4 EF
Duct & Building Air Leakage
All ducts & MVAC in conditioned space ( / no ) Insulation R- 8
Air handler present ( yes .)(1)( )
Test Target 100 CFM(c.?5Pa Test Result 100 CP@25Pa
Building air leakage target: ACl1;,, < 5.0 - Tested leakage: ACI I;(, 3. 1
Onsite Renewable Energy Electric Power System
System type: Rated annual generation
kwh
5-1