2002, 01-31 Permit App: 02000617 Residence Project Number: 02000617 Inv: 1 Application Da 40 Page 1 of 3
THIS IS NOT A PERMIT
Penalties will be assessed for commencing work without a permit
Project Information:
Permit Use: NEW RESIDENCE W/ATTACHED GARAGE-GAS Contact: PARAS GENERAL CONTRACTORS
Address: 3124 S REGAL,#160
C-S -Z: SPOKANE WA 99223
Setbacks: Front 40 Left: 10 Right: 42 Rear: 115 Phone: (509)535-8377
Group Name:
Pr ect Name
Site Information: ;: '..z
Plat Key: 006150 Name: RIDGEMONT ESTATES NO. 3-'HADD District f.
Parcel Number: 45251.9080 Block: 2 Lot: 1
SiteAddress: 2115 S STEEN RD Owner: Name: RIDGEMONT III LMTD PTNSHP
VERADALE,WA USA 99037 Address: 12929 E SPRAGUE AVE
Location::VER SPOKANE,WA 99216-0731
Zoning: SR-1 Suburban Residential 1
Water District: 999 UNKNOWN Hold: ❑
Area: 41.54 Acres Width: 105 Depth: 195 Right Of Way(ft): 60
Nbr of Bldgs: 1 Nbr of Dwellings: 1
Review Information:
Review i
tr qq
Site Plan Review Released By: �: .�:m t / C
---„.
j
Plan ReviewReleased By: : � „ a-y .6,'�
Approach/Drainage Released By: c� --
1 rti'A SCD —
7
'c e
Landuse/Zoning ....,., _
Released :. — —
_ __
_ _
__
. , , . , .
(-:-.1.,, ,,,,., ...,..), .....L_„i c-,.....‘„,:.., _,...)c.k..„.. , ..L.2_ (.,_ ., _i ,_,, ,..--, ,_ _
.......____,....
Sewer ReviewReleased By: ® ( 'OZ
It 1
11.lfl n YI—PZit'4rc'I
c
Operator: DMD Printed By: DMD Print Date: 1/31/2002
Project Number: 02000617 Inv: 1 'Application Date: 1/31/2002 Page 2 of 3
THIS IS NOT A PERMIT
Penalties will be assessed for commencing work without a permit
Permits:
Building Permit
Contractor: PARAS CONSTRUCTION INC Firm: PARAS CONSTRUCTION INC
Address: 3124 S REGAL ST 160 Phone: (509)535-8377
SPOKANE,WA 99223
Building Characteristics
Const Category: New Group: R-3 Type: VN
Nbr Of Dwellings: Occupant Load: Building Height: 27 Stories: 2
Bldg W x D: 65 x 34 Building Sq Ft: 2449 Sprinklers: ❑
Req Parking: Handicap Parking: Critical Materials: El
This Application: Total Project:
Description Grp Type Notes Sq Ft Valuation Sq Ft Valuation
2ND FLOOR R-3 VN 1,038 $64,356.00 1,038 $64,356.00
BASEMENT U R-3 VN 1,411 $16,311.16 1,411 $16,311.16
GARAGE U-i VN 762 $9,144.00 762 $9,144.00
RESIDENCE R-3 VN 1,411 $87,482.00 1,411 $87,482.00
Totals: 4,622 $177,293.16 4,622 $177,293.16
Item Description Units Unit Desc Fee Amount
RESIDENTIAL VALUATION 1 Y OR BLANK $1,285.00
STATE SURCHARGE 1 Y OR BLANK $4.50
RESIDENTIAL SURCHARGE 1 Y OR BLANK $282.70
Permit Total Fees: $1,572.20
Mechanical Permit
Contractor: KELLER HEATING Firm: KELLER HEATING
Address: 7402 E 8TH AVE Phone: (509)926-3551
SPOKANE,WA 99212
Item Description Units Unit Desc Fee Amount
GAS WATER HEATER 1 NUMBER OF $10.00
GAS APPLIANCE>100,000BTU 1 NUMBER OF $15.00
GAS PIPING 3 #OF UNITS $3.00
VENTILATING FANS 3 NUMBER OF $30.00
CLOTHES DRYER 1 NUMBER OF $10.00
GAS LOG OR GAS INSERT 1 NUMBER OF $10.00
HOOD -TYPE II 1 NUMBER OF $10.00
Permit Total Fees: $88.00
Operator: DMD Printed By: DMD Print Date: 1/31/2002
Project Number: 02000617 Inv: 1 Application Date: 1/31/2002 Page 3 of 3
THIS IS NOT A PERMIT
Penalties will be assessed for commencing work without a permit
Plumbing Permit
Contractor: GOLD SEAL MECHANICAL INC Firm: GOLD SEAL MECHANICAL INC
Address: 5524 E BOONE AVE Phone: (509) 535-5944
SPOKANE,WA 99212
Item Description Units Unit Desc Fee Amount
TOILETSBIDETS 3 NUMBER OF $18.00
SINKS 7 NUMBER OF $42.00
SHOWERS 1 NUMBER OF $6.00
TUBS 2 NUMBER OF $12.00
DISH WASHERS 1 NUMBER OF $6.00
GARBAGE DISPOSAL 1 NUMBER OF $6.00
CLOTHES WASHER 1 NUMBER OF $6.00
WAl'ER USING DEVICES 2 NUMBER OF $12.00
Permit Total Fees: $108.00
Notes:
Payment Summary:
Permit Type Fee Amount Invoice Amount Amount Paid Amount Owing
Building Permit $1,572.19 $1,572.19 $0.00 $1,572.19
Mechanical Permit $88.00 $88.00 $0.00 $88.00
Plumbing Permit $108.00 $108.00 $0.00 $108.00
$1,768.19 $1,768.19 $0.00 $1,768.19
Disclaimer:
Submittal of this application certifies the owner(or person(s)authorized by the owner)has both examined and finds the information
contained within to be true and correct,and agrees that all provisions of laws and/or regulations governing this type of work will be
complied with. Subsequent issuance of a permit shall not be contrued to he a permit for,or an approval of,any violation of any of the
provisions of the code or of any other state or local laws or ordinances.
Signature:
Operator: DMD Printed By: DMD Print Date: 1/31/2002
1 PROJECT APPLICATION
SPOKANE COUNTY DIVISION OF BUILDING& CODE ENFORCEMENT
Il
1026 WEST BROADWAY AVENUE
SPOKANE,WA 99260
SPO !, CO 509-477-3675
J
Project Description: 2// 4 41/j V ,@Cs'/DeAir/A"/./De-Air/Al--
TYPE OF APPLICATION
ivBuilding Permit ❑ Change in Use ❑ Grading ❑ Manufactured Home Permit
❑ Relocation ❑ Sign ❑ Tenant (New/Change) ❑ Other
SPECIFIC SITE INFORMATION
Street Address: 21/5 74if\/ )•
Assessor's Tax Parcel Number(s):
Legal Description:
Department Use Only
Water District/Purveyor: Sewer District/Purveyor Road width Setbacks ,Front: Rear:
School District: Fire District: Zoning
Left: Right:
OWNER/APPLICANT INFORMATION
0 Indicate who should be contacted regarding this project
❑ Owner: Phone: ❑Applicant: Phone:
Fax: Fax:
Mailing Address: Mailing Address:
City,State,Zip City,State,Zip
❑ Contractor Phone 535-8377 .. ❑ Architect/Engineer Phone
Paras Construction Inc. Fax 534-4239 Fax
Mailing address Mailing address
3124 S. Regal, #160
City,State Zip City,State Zip
Spokane, WA 99223
WA State Contractor license# Contact name:
PARASCI164KS
PROJECT INFORMATION
Building Information
Building height to peak #of storiesMain floor sq.ft. Unfinished basement sq.ft.
Z� 2 1411 141/
Dimensions Total habitable space 2"`i floor sq.ft. Finished basement sq.ft.
62 /o38 // b—
Occupancy group Construction type Garage sq.ft. Deck sq.ft.
✓o ) FP-Aryl D 7v 2-
Cost of project Heat source(electric,gas,etc.)
Ai G4$
Manufactured Home Sign
Width: Length: ' .':.('hat is the square footage of the sign How high is the sign?
face?
Year: Make: #of signs Area of existing signs
Relocation Fire Safety
Fire Sprinkler _ Tent
Previous address
Paint booth Fire Alarm Fireworks display
Proposed use Value
Special Inspections Required? Non-Residential Energy Code Compliance?
Firm Name
Phone Plans Examiner Phone
Inspectors: Address
Inspector Phone
O Concrete O Welding O Bolting O Reinforcement Address
ADDITIONAL SITE INFORMATION
Are there structures on the property? O Yes V No What is the current property size? �i �/ SF
If yes,identify on site plan (square feet or acres) r `f`
Is any part of the property within 250 feet of a shoreline? What is the current use of this property?'/� N r
If yes,identify on site plan O Yes )6 No Y
Is your property in a designated wildlife habitat area? Will the site be served by a septic system? O Yes % No
O Don't know O Yes NI No
Is any part of the property within a 100 yr flood plain? Are or will there be wells located on the property?
If yes,identify on site plan If yes,identify on the site plan O Yes A No
O Maybe O Don't know O Yes 0 No
Are there any wetlands,streams or ponds within 200 feet of the Is there evidence of fill or excavation on the property?
O Yes ' No
property?
If yes,identify on site plan O Yes rif No
Are there slopes greater than 30%on the property? 30 ft rise in 100 ft) Are critical or hazardous materials used or stored on site?
( %) O Yes 13 O
No AI' No "
DEPARTMENT USE ONLY
Is the property in a designated Stormwater Control Area? Is public sewer available to the site? O Yes O No
O Yes O No
Is the property inside the ASA? O Yes O No Is public water available to the site? O Yes O No
O Yes O No
Is the property inside the PSSA? O Yes O No Is the property located within 1000 feet of a Natural Resource
Area? O Yes O No
Date Received: Staff Representative:
72Z or' PLAN
This site pI n is being sub itted for thepurpose of
obtaining a building permit..nd is a true and correct
representation of the propo-al.All known property
lines/dimensions,curb lines structures and easements ADDRESSf f5-_S_ •
have been identified.Also in'icated are wetlands, ZONE —
bodies of water, slope- .r other critical areas. ROAD �1'd i i (,P
Signed: � %G,l FRS r' r•! ,,?' G
Date: ���/�az COMMS
REVIE'. I.
N
9f rzt /, I i8
17
® �q
1� -
/
Zv.� J I S
co --) • 30 ,
i
E Miall* F
/vloAlum eNT
9r& EoN goAN>
Zits s Sr-eN
i07" , 82oL14.- ,2• P} /40D,7QN gI PC76-Mo/vr 5rA-r .Let 3
\/e #- fr - / eovA'ry
24+cls'i 2-5T/2R