Loading...
2014, 08-20 Energy Compliance Certificatevb314 Property Address: 527 S St Charles Spokane Valley, WA Conditioned Floor Area: 2360 Date: 08/ 20 / 2014 Builder or registered design professional : Viking Builders Signature: Home Energy Audit Tech Le d$town 609 280 0381 R -Values Ceiling: Vaulted R- Floors: Over unconditioned space R - Attic R- 49 Slab on grade floor R - Walls: Above grade R- 21 Doors: Metal R- 5.6 Below, int. R- 21 Glazed R- 3.3 Below, ext. R- R- U -Factors and SHGC NFRC rating (or) Windows U- .30 SHGC- N/A Default rating (nppendiX A ws)C 2012) Skylights U- SHGC- N/A Table 406.2 Option(s) 5B Total 406.2 Credits 1.5 Heating, Cooling & Domestic Hot Water System Type Efficiency Heating Gas forced air 95.2% Cooling Electric central 13 seer DFIW Ele heat pump 50 gal 2.4 EF J Duct & Building Air Leakage All ducts & HVAC in conditioned space (I no ) Air handler present ( yes /XX) Test Target 95 CFM(c@25Pa Test Result Insulation R- 8 92 CFM(u%25Pa Building air leakage target: ACI130 < 5.0 - Tested leakage: ACRS„ = 3.22. - Onsite Z Onsite Renewable Energy Electric Power System System type: Rated annual generation Kwh