1992, 11-12 Permit App: 92010004 Residence , • SPOKANE COUNTY DEPARTMENT OF BUILDINGS
W. 1303 BROADWAY AVENUE
SPOKANE,WASHINGTON 99260
(509)456-3675
['certify that I have examined this permit/application,state that the information contained in it and submitted by me or my agent to compile said permit/application is true
and correct, and authorize Spokane County to proceed with processing. In addition, I have read and understand the INSPECTION REQUIREMENTS/NOTICE
provisions included herein and agree to comply with same.All provisions of laws and ordinances governing this type of work will be complied with whether specified
herein or not.I understand that the issuance of this permit/application and any subsequent inspection approvals or Certificates of Occupancy shall not be construed to
give authority to violate or cancel the provisions of any state or local law regulating construction,or as a warranty of conformance with the provisions of any state or local
laws regulating construction.
SIGNATURE OF APPLICATION
OWNER OR AGENT DATE
\)-11L-- -- ' 'ZI ) -7 7
PROJECT NUMBER= 9201 000.4 APPLICATION DATE- 11 /12/92 PACE= 01
**3tr:.*3i• THIS IS NOT A PERMIT * --,
PENALTIES W:i:I..,I... BE:: ASSESSED FOR COMMENCING WORK WITHOUT A PERMIT
T
SITE STREET= 1908 S STANLEY LN P tRt:'E"I...4:=: 35261 . 1086
ADDRESS- SPOKANE WA 992.02
PERMIT USE= RESIDENCE .... NrtT'URfiI... GAS
PLATO= 005025 PLAT NAME,- DEVON RIDGE
BLOCK== i LOT= 21 ZONE= UR-3.5 01:ST:k:-:: F
ARE:(:s4": F/A::: F WIDTH- ' ' DEPTH- 149 t/W- '30
0 OF TtL.DGG5'::- 4 DWELLINGS- i WATER DIST -: SPO CO WATER 0T. 1.O;'.
OWNER:-: LANCASTER HOMES PHONE- 206 2323
STREET= i4.41e TTI E::I... ' I"'F:D RD 4200
0
ADDRESS= BEI_.L.EVUE WA 98007
CONTACT NAME::: I...ANDC'A;4TFF? HOME::S' PHONE: NUMBER= 509 4%5 7400
BUILDING EETBACKS FRONT- 55 LEFT 13 RIGHT= 5 REAR= 65
•b:3i•*3t•*•3i•3i•3t 3t •3!:3i•3':•3f•3t•3t•****A•3t•3i•1<3t•R•3t•3r 3t•3i• REVIEW INFORMATION **********a***************
DEPARTMENT REVIEW COMMENTS APPROVAL. COMMENTS
BUILDING PLAN REVIEW V:CI.:W Rf"t>!(.t:I:RE:.D /1......1. _42--
BUILDING
..!b2-'T:{(._ CI...D:i:t ; SETBACK RE::t7:IE::W REQUIRED _..\1 , r_. lert
.. .. -2--
BUILDING
.X 5UI.t...D1.NG ENERGY PLAN REVIEW REQUIREi 1
It ,
ENGINEER APPROACH, FLOOD PLAIN DRAINAGE:: .
,i ��i
' liyr�� 0 / 7as.6.04-s^� ,(] " a r ' .. _ f
it.*3i•3S 3t it• .3t•it*N..x•]�•�: . t :••7t•*T:'P it it i 3t•i, t� ..I.i.Li)I t4,fa I''E:.E41"1 K. 1 .*it tt t it it ,.it it i+:p:•': ... ' t:n"M 1E*it.3t it
CONTRACTOR=tR. LANCASTER HOMES PHONE- 206 644 2323
...T..I.t t - 1441.03 HI I. ' RE RD4200AIYDR,t` ... BEL.LE..a UE WA 9800
NEW:::: X REMODEL:::: ADDITION= CHANGE OF USE::::
DWELL I.1i41 T =:, ICIC:("UF' I...0:::: BLDG HC;T: 10STORIES-
BLDG
TOR'::C E S-.
BLDG U D C '-. - . .. ,,0 SQ FT:-: '''.00 SPRINKLER=
�.
• REQ PARKING- :hHAND:I:CAP-:: CRITICAL.. MAT- .N
't, ,C4"•RF`T.r:U.tt GROUP , TYPE:: SO FT VALUATION
BASEMENT U R-3 VN 1 .05 1 .4355.00
GARAGE M....I VN 04 5632..00
RESIDENCE E;'•• ", VN 1 3i)5 70470.00
2ND FLOOR F; t I f 930 J.''.'::1 1 0:.00
ITEM DESCRIPTION QUAN..# ITY F E E AMOUNT
RESIDENTIAL VAL(.lATION Y 695.50
>TATE SURCHARGE HARGE:_ Y' 4 .50
'RESIDENTIAL SURCHARGE Y 125, 19
RADON MONITOR 'i 12 ,57
SALES TAX 1 1 , 01
i<:k 3k 3i 3i 3t h:3E 3t a if i 3i 3:3i.**3t fi-•)~3t :••3¢3r:t(..;t it it 3t 3E 3t MECHANICAL. P I..:F•M: ' *3i 3c 3:is i~r it it it 3t it 3!ri i*it m r 3i 3r'r.3r iF. 3':
CONTRACTOR-:: (.UNKNOWN PHONE-
STREET=
''F'ONE--
S'T'R1''EET-:: UNKNOWN
ADDRESS:::: UNKNOWN WA UNKNOWN
ITEM DESCRIPTION QUANTITY FEE AMOUNT
GAS WATER HEATER --ii
10. 00
GA HTC F:'QUI ''t;t100, 000 HT(.E i 12,00
GAS PIPING 7
GAS LOG 'i 10,00
**3i'.r.*•'r;N:*3i.3i•'r.•*3t. N•**3i..ri.:>`**3{3;.3i•3t• :• 3i. ( I...UMF1:Nt.
I''i':.t,!"f; *************3(-****************
CONTRACTOR- UNKNOWN PHONE-
,`:iTRE I:T UNI<NOWN
SPOKANE COUNTY DEPARTMENT OF BUILDINGS
W. 1303 BROADWAY AVENUE
SPOKANE,WASHINGTON 99260
(509)456-3675
I certify that I have examined this permit/application,state that the information contained in it and submitted by me or my agent to compile said permit/application is true
and correct, and authorize Spokane County to proceed with processing. In addition, I have read and understand the INSPECTION REQUIREMENTS/NOTICE
provisions included herein and agree to comply with same.All provisions of laws and ordinances governing this type of work will be complied with whether specified
herein or not.I understand that the issuance of this permit/application and any subsequent inspection approvals or Certificates of Occupancy shall not be construed to
give authority to violate or cancel the provisions of any state or local law regulating construction,or as a warranty of conformance with the provisions of any state or local
laws regulating construction.
SIGNATURE OF APPLICATION
OWNER OR AGENT DATE
PROJECT NUMBER= 92010004 APPLICATION DATE= 11 /12/92 PAGi::::: 02
ITEM DESCRIPTION QUANTITY FEE AMOUNT
TOILETS 4 24 :00
SINKS 30.00
SHOWERSI 6.00
BATH TUBS ., 12.00
KITCHEN `>'INK i 6.00
Ti:i: HWASHERS .i 6,00
GARBAGE D:ISPO Al... 1 6.00
CLOTHES WASHER R i . 0i•?
UTILITY SINKS I 6.00
LAWN SPR.KL.E"R PER BACKFLOW 1 6 :.00
PERMIT TYPE FE:.E. AMOUNT AMOUNT PAID AMOUNT OWING
BUILDING PERMIT 1338., 00 838. 77
MECHANICAL i='F'h T 35.00 0 0 0 35.00
PLUMBING PERMIT 108.00 .,+00 108.00
•
981 . 77 .00 981 .77
PROCESSED BY : BARRY HUSFLOEN
PRINTED BY : BARRY HUSLOEN
,fi. r nNp4* irphr*a { iNMhe k 4r *± Ni ih K (* THANK y . 1 *wre hri3K*# ry **ri*** r c r»r*yNk ; n „ n.n....,�....�,..
•
I
•
•
t
NOTICE
It is the responsibility of the permittee, not Spokane County, to see to it that the use described on the front of this permit
complies with applicable codes and requirements and that required inspections are requested. Failure to request required
inspections and obtain the necessary approvals prior to progressing beyond the point where inspections are required may
necessitate removal of certain parts of the construction at the owner's/permittee's expense. At a minimum, the following
inspections ARE REQUIRED by County Code:
1. FOOTING —when forms and reinforcement are in place and prior to placement of concrete.
NOTE:This inspection includes review of the structure's setbacks from property lines.Minimum setbacks are
established by County zoning regulations.Typically,side and rear yard setbacks are measured from property
lines, while setbacks for yards abutting streets are measured from the property line or the center line of the
roadway right-of-way,whichever provides the greater setback from the center line of the roadway right-of-way.
Curb lines and fence lines are not necessarily indicative of property lines.In some residential areas,the County
can own as much as 20 feet of right-of-way between your property and the actual improved street/curb.The
responsibility to comply with applicable setback provisions lies solely with the permittee— neither Spokane
County nor its authorized representatives assume any responsibility for the verification or location of your
property lines.Please verify their location prior to locating your structure.Failure to properly locate the structure
may require its relocation at the owner's/permittee's expense.
2. FOUNDATION—when forms and reinforcement are in place and prior to placement of concrete.(Blocking for a
manufactured home is required to be inspected prior to the installation of skirting.)
3. FRAMING—after all framing, bracing and blocking is in place,and prior to concealing.
4. INSULATION — prior to the installation of drywall.
5. PLUMBING —after rough-in, before covering, and final.
6. MECHANICAL— rough-in of piping, before covering, metal chimneys before concealment,and final.
7. FINAL—when complete and prior to occupancy and/or use. Please provide 24 hours notice.
NOTE:In addition to inspection of the structure,this inspection includes review of site improvements(typically
depicted on the approved site plan)required by ordinance or as a condition of approval of this permit.Items such
as the installation of fire hydrants,fire department access,on-site drainage("208 swales"),road improvements,
parking,and landscaping are common requirements of a permit/site plan which must be completed prior to final
approval of a building or issurance of a Certificate of Occupancy.
In addition to the above any plumbing or mechanical systems or materials which would be concealed by framing, drywall,
concrete, etc., must be inspected prior to cover. Check with the department for "special inspections" in conjunction with
commercial projects.
CALL 456-3675 FOR INSPECTIONS.
TO INSURE PROMPT SERVICE, PLEASE GIVE 24 HOUR NOTICE.
YOUR INSPECTOR IS
UNDER CERTAIN CIRCUMSTANCES, PARTS OF YOUR PROJECT MAY REQUIRE INSPECTIONS FROM OTHER
AGENCIES:
• road cuts for utilities or drives, State or County Engineer's Office
456-3600
• on-site waste disposal system, Environmental Health District
456-6040
• construction in a flood plain, County Engineer's Office
456-3600
• electrical wiring, State Department of Labor and Industries
456-2792
• sewer connection, County or City Utilities Department
456-3604
EXPIRATION
Unless otherwise noted,this permit will be considered null and void by limitation of the work authorized by the permit is not
commenced or is stopped for a period of 180 days, unless a written request for an extension of the permit is received and
approved by the Building Official prior to expiration.At a minimum an inspection should be requested at least once every 180
days to assure the validity of the permit.A permit may be renewed within one year of the date of expiration for one-half the
original fee, subject to certain limitations—please call us if you have any questions.
MISTAKES?
If you think we've made an error in processing this permit or in conducting inspections pertaining to it, or find erroneous
information in the permit,please bring it to our attention immediately by filing a written request for correction within 10 working
days of discovery.All such requests should be directed to the Department of Buildings at the address found on the face of this
permit.
f !
,• pc .0
( /)411".. 4 /
if (Iv 6
, /*CI t-11L 09
' 1 5�fre °
•
11 \ .
•• 0
• OC)
\\/..
7"----N ?)\.....'' ',,,, .
Ct
:;.11.4, _,_ '' 'L ao
,, .
1•..�...
trF ii N�• r, ^
M N '0
::;r:i= l
tr.) 1
l'`•-...k......e.:2.....
uiral _ .--th-..-3-‘'IrVaii,T= uw18 fi- le .4:104 4/ , ••Z
F 1.0
y _---1 w 44\ ' 4/.t'
^
D ��SCE
I. r � CJf.
IC, 41 �C - •• ��
` U�
►r. �, .,
✓I r
I /
� '4 , �/
. . . . . . . . ,. . . . . . . r to
. •
4 I --) _I ,< c. /
. . • • • I s( O /
ri _._____-\ — •-- • • .
L • . , s
4 796 /' . �; .:
•
•
` mss • •
•
\--- C 1 /8
_______________--------7-----, -1/44- .
/ . 63 . ,----n I
0
R / , , 7.-/*
v/1 7_/„
,.
r ./\ ______ ______ ____ 0
/q /N
__)(./------ \. ________
1--- D ,
J.E. P4111.1.1=11 U t 5 I Ci N ASSOCIATE MEMBER OF THE AMERICAN INSTITUTE OF ARCHITECTS
ARCHITECTURAL DRAFTING AND DESIGN SERVICES SOUTH 4524 STONE, SPOKANE. WA. 99223 (509) 448-5813
November 30, 1992
Spokane County Building Department
W. 1303 Broadway
Spokane, Wa. 99201
Re: Foundation footings for lots 20 & 21 of the final PUD plate
of Devon Ridge.
To Whom It May Concern,
It has come to the attention of J.E. MILLER DESIGN that the foundation
footings were poured without any horizontal reinforcement. From our best
understanding of the local building codes there are no requirements for
horizontal reinforcement in the footings. In addition to the local code
the forms for the footings and the vertical reinforcement in the foundation
wall were inspected and approved by Dave Silva of the Spokane County
Building Department. Therefor J.E. MILLER DESIGN recognizes the local code
and agrees with the approved site inspection authorized by Dave Silva.
Sincerely,
/// i
Jeffrey E. Miller
Associate AIA
II