Loading...
HomeMy WebLinkAbout1994, 11-07 Permit App: 94011139 ResidencePROJECT NUMBER= 94011139 APPLICATION DATE= 11/07/94 AGE= 01 ****** THIS IS NOT A PERMIT ****** PENALTIES WILL BE ASSESSED FOR COMMENCING WORK WITHOUT A PERMIT SITE STREET= 2117 S ST CHARLES RD PARCEL#= 45264.122OPTN ADDRESS= VERADALE WA 99037 PERMIT USE= RESIDENCE/ATTACHED GARAGE - FORCED AIR GAS PLAT#= 005262 BLOCK= 4 AREA= 00100000 # OF BLDGS= 1 PLAT NAME= AUTUMN CREST 3RD ADD LOT= 2 ZONE= UR 3.5 DIST#= F F/A= F WIDTH= 80 DEPTH= 125 R/W= 60 DWELLINGS= 1 WATER DIST = VERA OWNER= GORDON FINCH HOMES STREET= 9102aMIE COLUMBIA DR ADDRESS= SPOKANE WA 99217 PHONE= 509 926 7013 CONTACT NAME= GORDON FINCH HOMES PHONE NUMBER= 509 926 7013 BUILDING SETBACKS: FRONT= 25 LEFT= 5 RIGHT= 9 REAR= 39 ****************************** REVIEW INFORMATION ***************************** DEPARTMENT REVIEW REQUIREMENT BUILDING REVIEW COORDINATOR - R COMMENTS: BUILDING PLAN REVIEW REQUIRED COMMENTS: 11-7-14/ -11040 LOS 11-9-V BUILDING SETBACK REVIEW REQUIRED COMMENTS: 1 1/ 7-9 BUILDING SEWER PERMIT PENDING COMMENTS: 94-1110-0 qt -g -/252- II - ENGINEER APPROACH/FLOOD PLAIN/DRAINAGE COMMENTS: ******************************* BUILDING PERMIT ******************************* CONTRACTOR= GORDON FINCH HOMES INC STREET= 9102 E COLUMBIA DR ADDRESS= SPOKANE WA 99212 PHONE= 509 926 7013 NEW= X REMODEL= ADDITION= CHANGE OF USE= PROJECT NUMBER= 94011139 APPLICATION DATE= 11/07/94 PAGE= 02 DWELL UNITS= 1 OCCUP. LD= BLDG HGT= 12 STORIES= 1 BLDG W X D = 65 X 59 SQ FT= 1835 SPRINKLER= N REQ PARKING= #HANDICAP= CRITICAL MAT= N DESCRIPTION GROUP TYPE SQ FT VALUATION BASEMENT U R-3 VN 608 6688.00 DECK R-3 VN 180 900.00 GARAGE M-1 VN 780 6240.00 RESIDENCE R-3 VN 1427 78485.00 2ND FLOOR R-3 VN 543 15204.00 ITEM DESCRIPTION QUANTITY FEE AMOUNT RESIDENTIAL VALUATION Y 667.50 STATE SURCHARGE Y 4.50 RADON MONITOR 1 12.57 SALES TAX 1 1.01 RESIDENTIAL SURCHARGE Y 120.15 ******************************* MECHANICAL PERMIT ***************************** CONTRACTOR= RICK'S PLUMBING & HEATING STREET= BOX 3874 ADDRESS= SPOKANE WA 99220 ITEM DESCRIPTION PHONE= 509 534 4090 QUANTITY FEE AMOUNT GAS APPLIANCE<=100,000BTU 1 12.00 GAS LOG OR GAS INSERT 1 10.00 GAS WATER HEATER 1 10.00 GAS PIPING 3 3.00 VENTILATING FANS 5 50.00 ***************************** PLUMBING PERMIT ****************************** CONTRACTOR= BARTON HEATING & A/C INC STREET= 11401 E MONTGOMERY AVE #3 ADDRESS= SPOKANE WA 99206 ITEM DESCRIPTION PHONE= 509 922 5000 QUANTITY FEE AMOUNT TOILETS/BIDETS 3 18.00 TUBS 2 12.00 SHOWERS 1 6.00 SINKS 6 36.00 DISH WASHERS 1 6.00 CLOTHES WASHER 1 6.00 GARBAGE DISPOSAL 1 6.00 FLOOR DRAINS 1 6.00 WATER PIPING - DWV 1 6.00 WATER USING DEVICES 2 12.00 PERMIT TYPE FEE AMOUNT AMOUNT PAID AMOUNT OWING PROJECT NUMBER= 94011139 APPLICATION DATE= 11/07/94 PAGE= 03 PERMIT TYPE FEE AMOUNT AMOUNT PAID AMOUNT OWING BUILDING PERMIT 805.73 .00 805.73 MECHANICAL PRMT 85.00 .00 85.00 PLUMBING PERMIT 114.00 .00 114.00 PROCESSED BY: BURRIS, ROBIN PRINTED BY: BURRIS, ROBIN 1004.73 .00 1004.73 1030.00 ******************************** THANK YOU *********** * ************* METHOD III WORKSHEET JOB ADDRESS: ► 5T C} r i is FURNACE MODEL NUMBER: -5q5 CAV eq2o75 BRAND NAME: NRy4v-cr BTU INPUT: �� 000' WATER HEATER BRAND: BTU INPUT: 35, c-00 CUBIC FEET OF STRUCTURE: BASEMENT SQ. FT 1-1-7 3 X CEILING HEIGHT 3' = 37-y CU.FT. MAIN FLOOR t"�lctZ X CEILING HEIGHT ' = t Q 3 3 to CU.FT. 2ND FLOOR y 3 X CEILING HEIGHT 3' = CU.FT. TOTAL: = 1R -4-1u,14 - 3 o S 60 (1) CU.FT.TOTAL 30 X .35 = X07. k CFM MIN. (2) CU.FT.TOTAL 3 X .50 = i �� • (19 CFM MAX. FORMULA FOR COMBUSTION AIR: (3) 0.4 X 54, oco BTU INPUT = 35, v CFM 1000 A) CFM RATING FOR FURNACE: 35. Z USE (3) ABOVE FOR CFM RATING B) CFM RATING FOR POWER VENT HWT USE 90 CFM IF UNKNOWN C) ATMOSPHERIC TYPE H.W.T. USE 0.8 X 3 �� ow BTU INPUT= —r 1000 TOTAL: (' 3 - Z CFM REQUIRED CAPACITY OF ROUND METAL DUCT IN CFM:, 9" =300 CFM SIZE OF DUCT USED= (o it 10" =400 CFM TO RETURN AIR DROP 12" =670 CFM INSULATED TO A R-4 5"=65 CFM 6" =100 CFM 7"=160 CFM 8" =230 CFM SIZE OF EACH OPENING AS REQUIRED FOR CONFINED SPACE BY U.M.C. SQ.IN. SUBMITTED BY: COMPANY NAME: �s- DATE: i/ /L(/ c(y WATTSUN 5.3 1991 WA STATE ENERGY CODE COMPLIANCE REPOR 11/07/94 FILE: }. WHTT}.1J:iEMFILiHOUSE 14: A_5_SF' �t.v Site: 2117 '3 S. CHARLES VERADAL:, WA 93037 (509926-7613 Analyst: GORDONFINCH Jurisdiction: SPOKANE COUNTY Crtillty: WWR VERA Homeowner: House Type: Single Family ROOT' 2 LJt1VsROOT'Area:i: 2v I { tL Builder: GORDON FINCH Ht+&: 9102 COLUMBIA (509) 926-1013 Weatrier Data: 3pokane, WH Climate Tone: 2 I The PROPOSED design *COMPLIES* with 1391 WA State Energy Code. i COMPONENT PERFORMANCE I ENERGY BUDGET REFERENCE PROPOSED 5'7 551 Btu/hr-F *** *** icWh/ft2-yr REFERENCE DESIGN Reference Component Value X Area = UA BG Wall 7' BG Slab 7' On Grade Slab Floor Ula liig e15% Doors HG ;~all Ceiling, Attic Infiltration U-0.036 613 22.3 F-0.554 88ft 43.8 F-0.540 lulft 54.5 U-0.029 27 0.8 0-0.600 H4.5 230..1 U-0.400 42.0 16.8 0-0.062 2211 17.1 u-0.v3l i483 4o.2 ACM -0.350 13386ft3( 111.3; Reference '. PROPOSED DESIGN COMPONENTS Component Description Value X Area = UA BG Wall RO Uninsulated 7' depth U-0.185 619 114.5 BG Slab F-0.434 88ft 38.2 On Grade Slab R10 2' perim/R5 center F-0.420 101ft 42.4 Fioo'r R30 unvented Joist l6oc 0-0.029 27 v.8 biazlrig @14% 2b1 Vinyl 1/2' w/Ar 0-0.490 357.2 175.0 Doors i>etal 1-3'4 urethane flush U-0.140 42.0 :,.3 Items in parentheses not included in COMPONENT PERFORMANCE totals. Page 1 • • WATTSUN 5.3 1391 WA STATE ENERGY CODE COMPLIANCE REPORT 11/07/94 FILE: F:\WATTSUNS\NEWFILE HOUSE ID: AC552FRLV AG Wall R21 INT T1-il U-0.056 2238 125.3 Skylights @ 251 Wood 1/2" w/Ar U-0.600 4.0 2.4 Ceiling R38 blown Attic STD baffled 0-0.031 1485 46.0 Infiltration Standard Air Sealing ACH-0.350 18386ft3 (111.3) Proposed UA 551 Struc Mass Light Frame, Sheetrock walls N- 3.000 2563 7689 HEATING/COOLING/VENTILATING SYSTEMS PROPOSED Heating System Type: Gas Furnace Make: ARCO AIRE GUA464A0 Model: 1F56-444/ System Efficiency: 83 % Modified Efficiency: 78 % Design ACH: 0.60 Heating Load(at 66F dt): 50194 Btu/hr System Size: 50.2 kBtu/hr Maximum Size @150%: 75.3 kBtu/hr Average Annual Heat: *** MBtu Annual Cost: $ *** Ventilation System: Integrated w/Forced Air Furnace Cooling System: SEER: 0.0 (Unducted) Cooling Load(at 12F dt): *** Btu/hr Recommended Size @125%: *k* tons Annual cool requirement: *** kWh/yr Solar Access: Unshaded w/solar access PROPOSED DUCT SYSTEM Location Avg Rvalue Surface Area SUPPLY All in heated space RETURN All in heated space R- 8.0 142.5 ft2 Page 2 WATTSUN 5.3 1991 WA STATE ENERGY CODE COMPLIANCE REPORT 11/07/94 FILE: F:\WATTSUN5\NEWFILE HOUSE ID: AC552FRLV GLAZING ORIENTATION PROPOSED PROPOSED South ***ft2 North ***ft2 Southeast : *** Northwest : *** East *** West• *** Northeast : *** Southwest : *** Economic and energy consumption estimates are designed for comparative purposes only. Actual cost for heating will vary depending on weather conditions, occupant lifestyle and other factors. Page 3 SPOKANE COUNTY DEPARTMENT OF BUILDINGS ADDRESS ::.. G.5.....s.2 f ! 7 PERMIT �A # / o RESIDENTIAL ENERGY CODE INSPECTION CI IECKLIST ID> o PERIMETER INSULATION Il- 10 o APPROVED FOR COVER BY "GRAVEL BASE o PLASTIC MEMBRANE DATE • WINDOWS & DOORS PER PLANS (,/WINDOWS & DOORS CAULKED o ADVANCED FRAMING: c(SOLEPLATE CAULKED WALLS CEILINGS «PLUMBING//ELECTRICAL PENETRATIONS CAULKED a WALL INSULATION: R - VAULTED CEILING: R- 36 qk BATT INSTALLATION TECHNIQUES SEALED DUCTWORK t'EXHAUST FANS/DUCTS INSTALLED RECESSED LIGHTS g( VAPOR RETARDERS: WALL ✓ CEILING ATTIC VENT BAFFLES COMBUSTION AIR DUCTS INSTALLED pARAWLSPACE VENTILATION ,RADON FAN CIRCUIT o APPROVED FOR COVER BY /26) DATE MSCI IANICAL SYSTEMS s( BATH EXHAUST &KITCHEN EXHAUST A AUTOMATIC WHOLE HOUSE EXHAUST MAKE-UP AIR INTAKES DUC1WORK EQUIPMENT INSTRUCTIONS WEATHERSTRIPPING rek DOORS & WINDOWS sk ATTIC & CRAWL ACCESSES SWITCH & OUTLET COVER PLATES 0 •\INSULATION '9(I LOOR R- .'? re.HEATING FUEL & SYSTEM TYPE: f. ATTIC R- S Ie -BELOW -GRADE WALLS R- v 'TBATT INSTALLATION ECHNIQUES c 'RADON MONITOR • el -SERIAL NUMBER / e 3 09 / 4 PLUMBING 4 WATER HEATER PAD ctSHOWER FLOW FIREPLACE/WOODSTOVE FIREPLACE DOORS FLUE DAMPER COMBUSTION AIR 'C41/41 RAWLSPACE GROUND COVER la WLSPACE VENTILATION 'RADON VENT & LABEL 0 o FINAL APPROVAL BY Fe4-(--e-1 DATE - S! D IJSPCIIK2.0TP ST. CHARLES ROAD 0 0 U) N ...15' TM. 0.00' 15.00'15.00' , I 0' WAGE ESMT.-� � of I 8 '208' POND--- L j, 15.00',„ 15.00' J I BOTTOM 3' 1 e.00_ L 1—e.oa' _ J POND E2 T BO OM EL. 2048.59 U) N z- 6" WIDE D' • INAGE ESMT. 4,8 03M3ii, •SIN3VVAY. •ONDINV1 92.1NOti3 cA :HAIM Qvo GC.-1h1 3NO2 gs" av HD •SS38Ge. LOT 2, BLOCK 4 AUTUMN CREST THIRD ADDITION SCALE: 1"=20' INLAND PACIFIC ENGINEERING South 25 Altomont Spokone,Woshington (509) 535-1410 99202