Loading...
1994, 11-04 Permit App: 94011076 ResidencePROJECT NUMBER= 94011076 APPLICATION~` PAGE= 01 ****** THIS IS NOT A PERMIT ****** PENALTIES WILL BE ASSESSED FOR COMMENCING WORK WITHOUT A PERMIT SITE STREET= 2,25 S ST CHARLES RD ADDRESS= VERADALE WA 99037 PARCEL#= 45264.122OPTN PERMIT USE= RESIDENCE/ATTACHED GARAGE - FORCED AIR GAS PLAT#= 005262 PLAT NAME= AUTUMN CREST 3RD ADD BLOCK= 4 LOT= 5 ZONE= UR 3.5 DIST#= F AREA= 00100000 F/A= F WIDTH= 80 DEPTH= 125 R/W= 60 # OF BLDGS= 1 # DWELLINGS= 1 WATER DIST = VERA OWNER= GORDON FINCH HOMES STREET= 910224 E COLUMBIA DR ADDRESS= SPOKANE WA 99217 PHONE= 509 926 7013 CONTACT NAME= GORDON FINCH PHONE NUMBER= 509 926 7013 BUILDING SETBACKS: FRONT= 25 LEFT= 10 RIGHT= 15 REAR= 49 ****************************** REVIEW INFORMATION ***************************** DEPARTMENT REVIEW REQUIREMENT BUILDING CONTRACTOR LICENSE REQUIRED COMMENTS: BUILDING PLAN REVIEW REQUIRED COMMENTS: Los ?y BUILDING SETBACK REVIEW REQUIRED COMMENTS: BUILDING SEWER PERMIT PENDING COMMENTS: Nmeleig- -4/-6,4/ 11-7-N ENGINEER APPROACH/FLOOD PLAIN/DRAINAGE COMMENTS: ******************************* BUILDING PERMIT ******************************* CONTRACTOR= GORDON FINCH HOMES INC STREET= 9102 E COLUMBIA DR ADDRESS= SPOKANE WA 99212 PHONE= 509 926 7013 • r NEW= X REMODEL= ADDITION= CHANGE OF USE= PROJECT NUMBER= 94011076 APPLICATION DATE= 11/04/94 PAGE= 02 DWELL UNITS= 1 OCCUP. LD= BLDG HGT= 12 STORIES= 1 BLDG W X D = 55 X 46 SQ FT= 1347 SPRINKLER= N REQ PARKING= #HANDICAP= CRITICAL MAT= N DESCRIPTION GROUP TYPE SQ FT VALUATION BASEMENT U R-3 VN 1347 14817.00 DECK R-3 VN 180 900.00 GARAGE M-1 VN 528 4224.00 RESIDENCE R-3 VN 1347 74085.00 ITEM DESCRIPTION QUANTITY FEE AMOUNT RESIDENTIAL VALUATION Y 617.00 STATE SURCHARGE Y 4.50 RADON MONITOR 1 12.57 SALES TAX 1 1.01 RESIDENTIAL SURCHARGE Y 111.06 ******************************* MECHANICAL PERMIT ***************************** CONTRACTOR= BARTON HEATING & A/C INC STREET= 11401 E MONTGOMERY AVE #3 ADDRESS= SPOKANE WA 99206 ITEM DESCRIPTION PHONE= 509 922 5000 QUANTITY FEE AMOUNT GAS APPLIANCE<=100,000BTU 1 12.00 GAS LOG OR GAS INSERT 1 10.00 GAS WATER HEATER 1 10.00 GAS PIPING 3 3.00 VENTILATING FANS 4 40.00 ***************************** PLUMBING PERMIT ****************************** CONTRACTOR= RICK'S PLUMBING & HEATING STREET= BOX 3874 ADDRESS= SPOKANE WA 99220 ITEM DESCRIPTION PHONE= 509 534 4090 QUANTITY FEE AMOUNT TOILETS/BIDETS 2 12.00 TUBS 1 6.00 SHOWERS 1 6.00 SINKS 5 30.00 DISH WASHERS 1 6.00 CLOTHES WASHER 1 6.00 GARBAGE DISPOSAL 1 6.00 FLOOR DRAINS 1 6.00 WATER PIPING - DWV 1 6.00 WATER USING DEVICES 2 12.00 PERMIT TYPE FEE AMOUNT AMOUNT PAID AMOUNT OWING PROJECT NUMBER= 94011076 APPLICATION DATE= 11/04/94 PAGE= 03 PERMIT TYPE FEE AMOUNT AMOUNT PAID AMOUNT OWING BUILDING PERMIT 746.14 .00 746.14 MECHANICAL PRMT 75.00 .00 75.00 PLUMBING PERMIT 96.00 .00 96.00 917.14 PROCESSED BY: BURRIS, ROBIN PRINTED BY: BURRIS, ROBIN .00 917.14 ******************************** THANK YOU ************************************ WATTSUN 5.4 1991 WA STATE ENERGY CODE COMPLIANCE REPORT 11/04/94 FILE: C:\\WATTSUN5\\NEWFILE HOUSE ID: BG Slab F-0.511 Floor R30 _invented joist 16._ic U-0.029 029 Glazing i1111% **2g1 vinyl 1/2" U-0.480 Doors **METAL INSULATED W/RAISED PANEL U-0. 220 AG Wall R21 INT T1-li LJ -0.056 Skylights 0 2G1 Wood 1/2" w/1'_'w-E U-0,520 Ceiling R38 blown Attic STD baffled U-0.031 R49 blown Scissor 4:12 STD baffled U-0.038 Infiltration Standard Air Sealing ACH-0.350 Struc Mass Light Frame, Sheetrock walls 28ft 8 294. C ) 21.0 1122 8. 0 956 402 14J12ft3 14.3 O. c"_ 141. 1 4.6 62.8 4. 2 29. 6 15.3 ( 87.9) Proposed UA M- 3. 000 2700 493 8100 HEATING/COOLING/VENTILATING SYSTEMS Heating System Type: Make: System Efficiency: Modified Efficiency: Design ACH: Design Load(at 66F dt) : Duct Losses (% Dsn Load) : Total Lead: System Size: Average Annual Heat: Annual Cost: : PROPOSED Gas Furnace DEFAULT 78 % 0 0.60 43486 Btu/hr 0 Btu/hr( 0%) 43486 Btu/hr 65000 Btu/hr (150%) *** MBt u *** Ventilation System: Integrated w/Forced Air Furnace Cooling System: SEER: Cooling Load(at 12F dt): System Size(%Over): Annual Cool Requirement: Solar Access: 0. c) (Und uct ed ) Bt u/hr tons (I 125%) *** kWh/yr Partially Shaded PROPOSED DUCT SYSTEM Location Avg Rva l ue Surface Area SUPPLY All in heated space RETURN All in heated space R-11.0 108.0 ft2 Page 2 - WATTSUN 5.4 1991 WA STATE ENERGY CODE COMPLIANCE REPORT 11/04/94 FILE: C:\\WATTSUN5\\NEWFILE HOUSE ID: Site: Analyst: TOM BAGGOT Jurisdiction: SPOKANE COUNTY BUILDING Utility: INLAND POWER AND LIGHT Homeowner: : House Type: Single Family Floor Area: 2700 ft2 Builder: Weather Data: Spokane, WA Climate Zorae: 2 The PROPOSED design *COMPLIES* with 1991 WA State Energy Cede. COMPONENT PERFORMANCE ENERGY BUDGET REFERENCE PROPOSED 493 493 Btu/hr-F *** *** kWh/ft2--yr REFERENCE DESIGN Comp Inept Reference Value X Area = UA BG Wall 3.5' U-0.041 291 11.9 BG Slab 3.5' F-00.640 83ft 53.1 BG Wall 7' U-0.036 616 22.2 BG Slab 7' F-0.554 88ft 48.8 Floor U-0. 0`9 8 0. 2 Glazing 11115/ U-0. 600 405.0 243.0 Doors U-0. 400 21.0 8.4 AG Wall U-0.062 1011 62.7 Ceiling, Attic U-0.031 1366 42.3 Infiltration ACH-0. 350 14512ft3 ( 87.9) Reference UA 493 PROPOSED DESIGN COMPONENTS Component Description Value X Area = UA BG Wall BG Slab EAG Wall BG Slab BG Wall R19 Batt 3.5' depth RO Uninsulated 7' depth RO Uninsulated 3.5' depth U-0.041 193 7.9 F-0.625 55 f t 34.4 U-0.185 616 114.0 F-0.434 88ft 38.2 U-0.271 98 26.6 Items i n parentheses not included i n COMPONENT PERFORMANCE totals. ** Denotes non-standard values - check calculation of thermal value. WATTSUN 5.4 1991 WA STATE ENERGY CODE COMPLIANCE REPORT 11/04/94 FILE: C:\\WATTSUNS\\NEWFILE HOUSE ID: GLAZING ORIENTATION PROPOSED PROPOSED South ft2 North ft2 Southeast : Northwest : East West : Northeast : Southwest : Economic and energy consumption estimates are designed for comparative SPOKANE COUNTY DEPARTMENT OF BUILDINGS ADDRESS PERMIT Yir4.45 94. /ld 7 C o RESIDENTIAL ENERGY CODE INSPECTION CHECKLIST pi PERIMETER INSULATION R -/C, X GRAVEL BASE o PLASTIC MEMBRANE o APPROVED FOR COVER BY ►`'"C'C:' DATE • XZ WINDOWS & DOORS PER PLANSk WINDOWS & DOORS CAULKED VAPOR RETARDERS: WALL L o ADVANCED FRAMING: WALLS CEILINGS WALL INSULATION: R- 21 O VAULTED CEILING: R- `5 x BAIT INSTALLATION TECHNIQUES SOLEPLATE CAULKED CEILING 1. PLUMBING//ELECTRICAL PENETRATIONS CAULKED /SEALED DUCTWORK « EXHAUST FANS/DUCTS INSTALLED rs( RECESSED LIGHTS # ATTIC VENT BAFFLES AL COMBUSTION AIR DUCTS INSTALLED h,A/-RAWLSPACE VENTILATION 0<RADON FAN CIRCUIT o APPROVED FOR COVER BY /G� ,' DATE • gt,MECI IANICAL SYSTEMS c BATH EXHAUST gC KITCHEN EXHAUST ,4 AUTOMATIC WHOLE HOUSE EXHAUST ,at MAKE-UP AIR INTAKES 9(DUCIWORK A EQUIPMENT INSTRUCTIONS HEATING FUEL & SYSTEM TYPE: 0 RADON MONITOR cif SERIAL NUMBER /D 3 49 4 WEATHERSTRIPPING DOORS & WINDOWS g ATTIC & CRAWL ACCESSES SWITCH & OUTLET COVER PLATES 0 X INSULATION o FLOOR R - At ATTIC R- - S' 'BELOW -GRADE WALLS R- /c a BATT INSTALLATION TECHNIQUES PLUMBING , WATER HEATER PAD SHOWER FLOW FIREPLACE/WOODSTOVE FIREPLACE DOORS FLUE DAMPER COMBUSTION AIR CRAWLSPACE GROUND COVER 'WA WLSPACE VENTILATION sf RADON VENT & LABEL 0 o FINAL APPROVAL BY 1%'C.!6., v DATE - & 4 S 0 INSPl Q1(2A iP •SIN3WW0'/ 1NOd3 SCALE: 1" =20' Oe) •H10IM OVO8 3NOZ S--91114$140 ',S S70ZS .SS3800 T. CHARLES ROAD q-- SIDEWALK & CURB INLETS t 5' TYP. i I • 15.00' 15.00' o; 0 0 1 ! :� I L 15.00' 15.00' - . 1231-18.70: —�� TECO - 1 0 0 ui N 80.00' DRAINAGE ESMT. '208' POND BOTTOM POND El BOTTOM _nen o_ 25' BLD . SETBACK WIDE DRAINAGE ESMT. 0 0 ui N ( LOT 5, BLOCK 4 AUTUMN CREST THIRD ADDITION INLAND PACIFIC ENGINEERING South 25 Altamont Spokane.WaehIngton (509) 535-1410 99202