2003, 07-29 Permit App: BD-03-826 Residential Sprinkler
�rwu ne 11707 E. SPRAGUE, STE 106 SPOKANE VALLEY, WA 99206 �� (509)688-0036 FAX (509)688-0037 PROJECT TRANSMITTAL: 'TRANSMITTAL DA 1'b: SITE INFORMATION PERMIT INFORMATION Site Address:• C s Parcel Number: Subdivision: Block: Lot: Zoning: Water Dist: Owner:�9)A. � 1 I ( c) Address: Building Inspector: Permit Number: 3_ cr2Issue Date: Permit Use: Applicant: Contact: Contractor: fl FA Phone: Phone: Setbacks — Front: Left: Right: Rear: BUIL GS: APPROVALS LANNING: E GINEERS: HE TH: FIRE DISC . WATER DIST: APPROVALS >TORMWATER: )1'HER: City of SPOKANE VALLEY BLD O.P. 23C Building, Fire and Public Works Fees Receipt Applicant/Business Permit No.FDr53� Project Name Date "7-eQ1 ,o3 Site Address OHO Please Receipt the Following: Check Number? Payers Name --Re',,, c I , Ct Address iC (, r c, F I BUILDING DEPARTMENT 001.059.322.10.01 001.059.322.10.02 001.059.322.10.03 001.059.322.10.04 001.059.322.10.06 001.059.322.90.01 001.059.345.83.01 001.059.345.83.03 001.059.342.40.02 001.059.237.10.98 001.059.237.10.02 FIRE DEPARTMENT # 001.059.322.10.07 001.059.322.10.08 001.059.322.10.09 001.059.322.10.10 001.059.322.10.11 001.059.322.10.12 001.059.322.10.13 001.059.321.30.00 001.059.342.40.01 001.059.237.10.99 OTHER: Receipt Number R ( 2 City Cid w.4 Zip cz2e-) Building Permit Plumbing Permit Grading Permit Mechanical Permit Demolition Permit Misc. Permits and Fees Plans Check Fee Energy plans check fee SPECIAL Inspections Bonds / Deposits WSBCC Surcharge * Plans check fee Sprinkler plans check F. A. Plans check Misc. plans check Fire Alarm inspections Sprinkler inspections Misc. Inspections Fireworks Permit UFC permit fees Bonds / Deposit PUBLIC WORKS 001.059.322.40.00 001.059.342.40.03 001.059.237.10.99 ** Right of Way Special Inspections Bonds/Deposits (cash)** TOTAL AMOUNT DUE * To be sent to Wash. State Building Code Council quarterly. # 65% of figure to be sent to the Fire Department Quarterly, except bonds etc. * * Liability Insurance verification may also be required. • s-vb1d23c 4-21-03 JUN 30 2003 12:23 FR y•of Spokane Valley )7 East Sprague Avenue, Suite 106 :ane Valley, WA 99206 TO 5355623 P.02/04 PERMIT # BUILDING PERMIT APPLICATION PHONE (.509)688-0036 FAX # (509)688-0037 Sox 1 OWNER pr,,, c: v (i,4t • JOB LOCATION /23C 7 5, 5-kel., ied VV i/r Aie-(v OWNER'S ADDRESS /a 413- E_I ., CITY 5rel e PHONE jese0 5 3 i-C'5S Y 037 DESCRIBE JOB 1—frtS4e, It a 14P 1144 hip % 'Sr" IC 1 - 51.464A 1 r- t r� 400d-tvt� THIS PROPERTY IS OWNED BY: SINGLE/MARRIED >C PARTNERSHIP CORP. OX 2 CONTRACTOR'S NAME �0A YL' 1 tAj PHONE CONTRACTOR'S ADDRESS CITY CONTRACTOR'S REG.# EXPIRATION DATE (CARD MUST BE PRESENTED AND COPIED OR VERIFIED) )X 3 CONTACT PERSON OF PROJECT %;4 ,-v` I 1 PHONE CITY ZIP . ADDRESS assasa—:x� -- ' XX 5 ESTIMATED PROJECT COST $ EXISTING BLDG. VALUATION $ . �.�. X 6 PROPERTY TAX ACCOUNT NUMBER LEGAL DESCRIPTION X 7 BUILDING SQUARE FOOTAGE (Existing / proposed) 1ST FLOOR 3RD FLOOR / OTHER / BASEMENT UNFINISHED / DECK • 2ND FLOOR / BASEMENT FINISHED / GARAGE / CARPORT / TOTAL / HEIGHT TO PEAK OF BUILDING FT. (8 ( ), SINGLE FAMILY ( .) MULTIFAMILY (NO. OF UNITS ( ) COMMERCIAL / INDUSTRIAL ( ) TENANT IMPROVEMENT ( ) NEW CONSTRUCTION ( ) EXISTING STRUCTURE • TOTAL AREA OF PROPERTY SQ. FT. IMPERVIOUS SURFACE SQ. FT. IIFY UNDER THE PENALTY OF PERJURY THAT THE INFORMATION FURNISHED BY ME IS TRUE AND • • RECT TO THE BEST OF MY KNOWLEDGE AND FURTHER THAT I AM AUTHORIZED BY THE OWNER OF THE dE PREMISESTO-PERFORM i1AE-WIK FOR WHICH THE APPLICATION IS MADE. ' [ER / AGENT DATE J� •eby authorize the City of Spokane Valley to charge the fee for this permit to my credit card: Mastercard the name of the Holder • Expiration Date Signature JUN 30 2003 12:23 FR TO 5355623 P.04/i4 Neil y terns 1. Commercial a. Plans check, inspection, & permit Based on value G o CMZ 2. Residential -- each riser $ 60.00 _ _ plus each plug or head $ 1.10 X) . D. Fire extinguishing system: (other than sprinklers) $ 50.001. Fire extinguishing'system plus each. nozzle $ 1.50 E. Standpipe installation: Class I and Class II Class III . $ 58.00 $ 70.00 F. Fire Pump Installation: $ 55.00 G. Power generators installation: $ 55.00 H. Flammable and combustible liquids storage tanks installation: 1. , Underground, 1st tank $ 55.00 • plus each additional tank on same site $ ,35.50 2. Above 'groun.d tank $ 55.0 plus each ad itional tank on the same site 3. Annual permit fee for storage $ 30.00 Hazardous materials storage tAnks installation: 1. Less than 500 gallons - each $ 75.00 2. 500 -1,199 gallons each .$104.00 3. 1,200 gallois or more $147.00 J. Liquefied petroleum tanks- installation 1. Less than 500 gallons 2. 500 - 9,999 gallons 3. 10,000 gallons or more K. Gaseous oxygen systems installation: 1. Less than 6,000 cubic feet 2. 6,000 -11,999 cubic feet 3. 12,000 cubic feet or more L. Nitrous systems installation: 1. phis each outlet r FEE err A-1 rcvised 5-21.03 1030 hours 10 $ 84.00 $104.00 $147.00 $ 78.00 $ 90.00 $118.00 $ 95.00 12.00 Page 1 Material Submittal Project Name: Darling Residence Description Section 1 - Pipe and Fittings Manufacturer Part/Model Number 1. Blazemaster CPVC Pipe & Fittings 2. 3. 4. 5. 6. 7. 8. Section 2 - Hangers and Swav Bracing 1. CPVC Hangers 2. 3. 4. 5. 6. 7. 8. Section 3 - Valves and Accessories Blazemaster Central SPOKANE VALLEY FIRE DEPT. Approved As Noted Date: By: • e"j>--- 0)".e2- I A16'.YL-0- 1. Riser Manifold Central 513 2. Fire Department Connection 3. Double Check Valve Assembly Febco 850 4. 5. 6. 7. • 8. 9. 10. 11. 12. Section 4 - Alarms and Supervisory Devices 1. Part of Riser Manifold (Above) 2. 3. 4. 5. 6. 7. 8. Section 5 - Fire Sprinklers and Accessories Size 1"-2" 1-1/2" 1-1/2" 1-1/2" 1. Residential Concealed Pendent Sprinkler GEM LFII 1/2" 2. 3. 4. 5. 6. : : : : : : : : : : : : : : . : : : : : : : : : : : : : :•: : : : : : : : : : : : : : : : : : : : : : : Nyco Flow Control Tyco Fire Products FIRE SPRINKLER PIPE & FITTINGS SUBMITTAL SHEET TYCO FIRE PRODUCTS 451 North Cannon Avenue Lansdale, Pennsylvania 19446 www.tyco-fire.com TECHNICAL SERVICES TEL (800) 381-9312 • FAX: (800) 791-5500 E-MAIL techserv@tycofp.com No. 19-1.5 TD915 4-1.1.20 9/2001 cERneneo Introduction Tyco Fire Products (TFP) BlazeMaster® CPVC pipe and fittings are designed exclusively for use in wet pipe automatic fire sprinkler systems. They are made from a specially developed thermoplastic compound composed of post chlorinated polyvinyl chloride (CPVC) resin and state of the art additives. TFP BlazeMaster® CPVC products are easier to install than traditional steel pipe systems, and at Technical Data the same time, they provide superior heat resistance and strength as compared to traditional CPVC and PVC piping materials used in the plumbing trade. Various adapters are available to connect CPVC pipe to metallic piping. All female pipe thread adapters have brass inserts for durability. Grooved adapters connect directly to grooved end valves and metallic pipe, with flexible grooved end couplings. Sizes: 3/4" - 3" Maximum Working Pressure: 175 psi Approvals: UL, FM, CUL, NSF, Dade County, LPCB, MEA, and the City of Los Angeles Note: See current TFP BlazeMaster Installation Instructions and Technical Manual, for exact listing/approval information Pipe Manufacture Source: U.S.A. Material: Pipe: ASTM F442, SDR 13.5 Fittings: ASTM F438 (Sch. 40) and ASTM F439 (Sch. 80) Color: Orange Nom.Pipe Size Avg. O.D. Inches Avg. I.D. Inches Wt. Lbs./Ft. Wt. H2O filled Pipe Lbs./Ft. Ft. of Pipe per Lift Wt. per Lift Lbs. 1/4" 1.050 0.874 0.17 0.43 7875 1413 1" 1.315 1.101 0.26 0.67 5040 1320 11/4" 1.660 1.394 0.42 1.07 2835 1191 11/2" 1.900 1.598 0.55 1.40 2205 1136 2" 2.375 2.003 0.86 2.20 1260 1063 2 '/2" 2.875 2.423 1.26 3.22 1215 1531 3" 3.500 2.952 1.87 4.79 720 1344 Fittings 45° Elbow T/0 Part No. Size Sch. T/O Wt. 80050 3/4" 40 3/8" 0.08 Ib. 80051 1" 40 3/8" 0.11 Ib. 80052 11/4 40 3/6" 0.20 Ib. 80053 11/4" 80 '/16" 0.31 Ib. 80054 2" 80 3/4" 0.56 Ib. 80055 21/2" 80 3/4" 0.89 Ib. 80056 3" 80 1" 1.19 Ib. Tee Part No. Size Sch. T/O Wt. 80000 3/4" 40 5/8" 0.11 Ib. 80001 1" 40 3/" 0.19 Ib. 80002 11/." 40 78" 0.26 Ib. 80003 11/2" 80 1" 0.51 Ib. 80004 2" 80 13/8" 0.90 Ib. 80005 21/2" 80 19/,6" 1.59 Ib. 80006 3" 80 111/46" 2.41 Ib. Reducing 90° Elbow T/O' Part Size Sch. T/O Wt. No. Size Sch. 1 2 Ib. 80032 1" x 3/4" 40 11/16" 13/16" 0.16 Reducing Cross Part Size Sch. T/02 Wt. No. Size Sch. bt. 1 80026 80015 1" x 3/4" 40 11/,6" 11/16" 0.28 90° Elbow Part No. Size Sch. T/O Wt. 80025 3/4" 40 9/,6" 0.09 Ib. 80026 1" 40 1/4" 0.14 Ib. 80027 11/4" 40 7/8" 0.21 Ib. 80028 11/2" 80 11/16" 0.40 Ib. 80029 2" 80 11/4" 0.79 Ib. 80030 21/2" 80 11/2" 1.14 Ib. 80031 3" 80 113/16" 1.82 Ib. Cross Part No. Size Sch. T/O Wt. 80009 3/4" 40 9/16" 0.13 Ib. 80010 1" 40 15/16" 0.23 Ib. 80011 11/4" 40 1$/16' 0.34 Ib. 80012 11/2" 80 11/46" 0.67 Ib. 80013 2" 80 13/8" 1.00 Ib. 80014 21/2" 80 19/,6" 1.91 Ib. 80008 3" 80 173/,6" 2.89 Ib. Coupling -�r T/0 Part No. Size Sch. T/O Wt. 80075 3/4' 40 '/8" 0.07 Ib. 80076 1" 40 1/8" 0.11 Ib. 80077 11/4" 40 3/,e" 0.12 Ib. 80078 11/2" 80 3/,6" 0.25 Ib. 80079 2" 80 3/18" 0.38 Ib. 80080 21/2" 80 3/16" 0.67 Ib. 80081 3" 80 3/18" 0.91 Ib. Grooved Coupling Adapter Cap Part No. Size Sch. T/O Wt. 80100 3/4" 40 5/16" 0.04 Ib. 80101 1" 40 3/8" 0.06 Ib. 80102 11/4" 40 1/2" 0.10 Ib. 80103 11/2" 80 5/8" 0.20 Ib. 80104 2" 80 5/8" 0.31 Ib. 80105 21/2" 80 '/8" 0.58 Ib. 80106 3" 80 1" 0.88 Ib. T/0 Part No. Size Sch. T/O Wt. Pipe OD 80160 11/4" x 11/4" Grooved 40 2 5/18" 0.78 Ib. 11/4" (1.660") 80161 11/2" x 11/2" Grooved 80 2 5/,6" 0.95 Ib. 11/2" (1.900") 80162 2" x 2" Grooved 80 2 5/18" 1.42 Ib. 2" (2.375") 80163 21/2" x 21/2" Grooved 80 2 5/16" 2.28 Ib. 21/2" (2.875") 80164 3" x 3" Grooved 80 2'/4' 3.00 Ib. 3" (3.500") 80168 3" x 76.1 mm Grooved 80 21/4' 2.72 Ib. 76.1 mm (3.000") Female Adapter T/O Part No. Size Sch. T/O Wt. 80142 3/4" x 3/4' NPT 40 5/e1. 0.41 Ib. 80145 1" x 1" NPT 40 3/4" 0.63 Ib. 80146 1'/4" x 11/4" NPT 40 '/e° 1.03 Ib. 80147 11/2" x 112" NPT 80 1" 1.42 Ib. 80148 2" x 2" NPT 80 13/8" 2.66 Ib. Male Adapter T/O Part No. Size Sch. T/O Wt. 80157 3/4' x 3/4" NPT 40 15/,6" 0.33 Ib. 80158 1" x 1" NPT 40 13/8" 0.56 Ib. Reducing Coupling Part No. Size Sch. T/O Wt. 80220 1" x 3/4" 40 1/8" 0.08 Ib. Reducer Bushing Part No. Size Sch. T/O Wt. 80200 1" x3/4' 40 /,e" 0.04 Ib. 80201 11/4" x3/4" 40 7/,8" 0.11 Ib. 80202 11/4" x 1" 40 5/,6' 0.12 Ib. 80203 11/2" x 3/4" 80 5/8" 0.16 Ib. 80204 11/2" x 1" 80 1/2" 0.14 Ib. 80205 11/2" x 1'/4" 80 3/8" 0.17 Ib. 80206 2" x3/4" 80 3/4" 0.27 Ib. 80207 2" x 1" 80 "/,6" 0.26 Ib. 80208 2" x 11/41" 80 9/,e" 0.24 Ib. 80209 2" x 11/2" 80 7/,611 0.19 Ib. 80215 21/21" x 1" 80 115/,6" 0.42 Ib. 80214 21/2" x 11/4" 80 13/4" 0.45 Ib. 80213 21/2" x 1'/2" 80 15/8" 0.46 Ib. 80211 21/2" x 2" 80 19/,8" 0.29 Ib. 80210 3" x 2" 80 2 3/16" 0.72 Ib. 80212 3" x 2'/2" 80 115/16" 0.47 Ib. Reducing Tee Part No. Size Sch. T/O Wt. 1 2 3 Ib. 80132 3/4" x 3/4" x 1" 403/4" 3/4" 5/8" 0.14 80133 1" x 3/4" x 3/4" 40 '/2" '3/46" 3/4" 0.14 80134 1" x 3/4" x 1" 40 5/8" 3/4" 3/4" 0.17 80260 1" x 1" x 3/4" 40 3/44 3/44 11/16" 0.16 80135 11/411 x 1" x 3/4" 40 '/,6" 3/4' 5/16" 0.21 80136 1'/4" x 1" x 1" 40 "/16" 3/4° 5/,6" 0.22 80137 114" x 1" x 11/4" 40 73/,6" 15/,6" 13/,6" 0.26 80261 11/4" x 11/4' x 3/4" 40 5/9" 5/e '/81 0.23 80262 11/4" x 1'/4" x 1" 40 3/4" 3/4" '/s" 0.26 80138 1'/4" x 11/4" X 11/2" 80 1" 1" 1" 0.43 80140 172" x 11/4" x 3/4" 80 '/2" 5/6" 1" 0.36 80141 11/211 x 11/4" x 1" 80 1/2" 5/6" 11/5" 0.38 80263 1'/2° x 11/2" x 3/4" 808/16" 9/16" 1" 0.36 80264 11/211 x 1'/2" x 1" 80 9/16" 9/,6" 1" 0.38 80275 172" x 11/2" x 11/4" 80 7/8" 7/8" 1" 0.45 80265 2" x 2" x 3/4" 80 3/4" 3/4" 13/8" 0.61 80266 2" x 2" x 1" 80 7/8" 7/8" 13/8" 0.66 80274 2" x 2" x 1'/4' 80 1" 1" 13/8' 0.74 80267 2" x 2" x 1'/2" 80 11/8" 1'/8" 13/8" 0.78 80271 21/2" x 2'/2" x 1" 80 111/16" 1 -he" 19/,6" 1.43 80272 21/2" x 2'/21" x 11/4" 80 111/18' 1"/,e 19/,e" 1.46 80273 21/2" x 21/2" x 11/2" 80 1"/1e 111/18' 19/16" 1.48 80276 21/2" x 21/2" x 2" 80 111/16' 1 "/16' 19/,6" 1.50 80270 3" x 31" x 112" 80 13/4" 13/4" 113/,6' 2.28 80268 3" x 3" x 2" 80 13/4' 13/4" 13/4' 2.25 80269 3" x 3" x 21/2" 80 13/4" 13/4" 115/,6" 2.44 Sprinkler Head Adapter with Brass Threaded Insert - T/O -- Part No. Size Sch. T/O Wt. 80175E 3/." x'/2" NPT 80 716" 0.20 Ib. 80176E 1" x1/2" NPT 80 716" 0.22 Ib. 80177WL 3/6" x1/2" NPT 40 9/,6" 0.16 Ib. 80179 1 x 3/4" NPT 40 3/4" 0.43 Ib. Sprinkler Head Adapter (Spigot) with Brass Threaded Insert Part No. Size Sch. TIO Wt. 80177L 3/4" X1/2" NPT 40 1/2" 0.16 Ib. 80178 1" x 1/2" NPT 40 1/2" 0.20 Ib. Sprinkler Head Adapter 90° Elbow with Brass Threaded Insert PartT/0Wt. No. Size Sch. T/O 1 2 80199 3/4" x 1/2" NPT 40 5/80 15/16" 0.20 80189 1" x1/2" NPT 40 13/16" 13/16" 0.26 Sprinkler Head Adapter Tee with Brass Threaded Insert Sprinkler Head Adapter with Brass Threaded Insert TL - T/0 Part No. Size Sch. T/O Wt. 80175W 1/4" x1/2" NPT 40 7/4" 0.19 Ib. 80176W 1" x'/2" NPT 40 7/16" 0.18 Ib. Back -to -Back Cross with Brass Threaded Insert Part Size Sch. T/O Wt. No. Size Sch. 1 2 Ib. 80462 1" x 1" x1/2" NPT x 'b" NPT 40 5/a' 11/8' 0.46 80463 1" x 1" x1/2" NPT x'/2" NPT 40 5/6" 15/16" 0.47 Back -to -Back Tee with Brass Threaded Insert T/0 T/0 .- IR T/O' Part Size Sch. T/O Wt. No. 2 3 1 2 Ib. 80459 1" x1/2" NPT x'/2" NPT 40 "/,6" 15/16" 0.48 80460 1" x1/2" NPT x '/2" NPT 40 "/16" 1'/6" 0.46 Part No. Size Sch. T/O Wt. Ib. 1 2 3 80250 3/4" x 3/4" X '/2 NPT 40 5/e' 5/8" 1" 0.22 80251 1" x 1" x'/2" NPT 40 11/16" "/,6" 73/16" 0.29 80249 1" x 1" x 1" NPT 40 15/16" 15/1e' 17/16" 0.73 80256 1'/4" x 1" X'/2" NPT 40 7/16" 9/16" 11/6" 0.30 80252 1'/." x 11/4" X'/2" NPT 40 7/,6" 1/46" 11/6" 0.31 80257 1'/2" x 11/4" x'/2" NPT 80 9/16" 5/6" 17/16' 0.43 80254 1'/2" x 11/2" x'/2" NPT 80 9/15" 9/,6" 17/,6" 0.46 80258 2" x 11/2" x 1/2" NPT 80 1/2" 5/6" 15/6" 0.56 80253 2" x 2" x1/2" NPT 80 1/2" 1/2" 15/8' 0.62 Limited Warranty Products manufactured by Tyco Fire Products are warranted solely to the original Buyer for ten (10) years against defects in material and workmanship when paid for and properly installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment by Tyco Fire Products. No warranty is given for products or components manufactured by companies not affiliated by ownership with Tyco Fire Products or for products and components which have been subject to misuse, improper installation. corrosion, or which have not been installed, maintained. modified or repaired in accordance with applicable Standards of the National Fire Protection Association (NFPA), and/or the standards of any other Authorities Having Jurisdiction. Materials found by Tyco Fire Products to be defective shall be either repaired or replaced, at Tyco Fire Products sole option. Tyco Fire Products neither assumes, nor authorizes any person to assume for it. any other obligation in connection with the sale of products or parts of products. Tyco Fire Products shall not be responsible for sprinkler system design errors or inaccurate or incomplete information supplied by Buyer or Buyer's representatives. IN NO EVENT SHALL TYCO FIRE PRODUCTS BE LIABLE, IN CONTRACT, TORT, STRICT LIABILITY OR UNDER ANY OTHER LEGAL THEORY. FOR INCIDENTAL, INDIRECT, SPECIAL OR CONSEQUENTIAL DAMAGES, INCLUDING BUT NOT LIMITED TO LABOR CHARGES. REGARDLESS OF WHETHER TYCO FIRE PRODUCTS WAS INFORMED ABOUT THE POSSIBILITY OF SUCH DAMAGES, AND IN NO EVENT SHALL TYCO FIRE PRODUCT'S LIABILITY EXCEED AN AMOUNT EQUAL TO THE SALES PRICE. THE FOREGOING WARRANTY IS MADE IN LIEU OF ANY AND ALL OTHER WARRANTIES EXPRESS OR IMPLIED. INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, VICO/Flow Control / Tyco Fire Products CENTRAL SHB1/S012-S032 2-99 CPVC Hangers Head SetTM Mounting Bracket No BlockTM Hanger Manufactured for: Central Sprinkler Company 451 North Cannon Avenue, Lansdale, Pennsylvania 19446 Product � Technical Description Data The Central Model SHB1 Head Set Hanger and the BlazeMaster CPVC No Block Hanger offer revolutionary time saving installation methods for the hanging of BlazeMaster CPVC pipe and for proper pre -placement of the sprinkler head before the ceiling is installed. The SHBI also provides vertical restraint of the Sprinkler Head eliminating the need for additional hangers. By aligning the appropriate serration on the depth tab with the bottom of the ceiling joist, the installer is assured of the desired and uniform finish to the sprinkler head location being positioned in the ceiling. Due to the unique design of the SHBI, "blocking" is not required to offset the centerline of piping to accomodate the sprinkler escutcheon from the side of the joist. The No Block BlazeMaster CPVC Hanger is a simple two -hole strap for hanging BlazeMaster CPVC pipe. With the No Block Hangers, there is no longer the need to install "blocking" to offset piping from wall studs or the face of floor or ceiling joists. Model: SHB1, S012, S016, S020, S024 and S032 Approvals: UL listed for BlazeMaster CPVC Complies with static load requirements of NFPA13 (1996 Edition) Material: SHB1: Galvanized, Aluminum Killed Drawing Quality Steel; 20 Gauge Installation 2 Hole SO: SAE 1008-1010 Roll Hot Dip G60 Galvanized Steel; 20 Gauge Weight: SHB1 Headset:- .2627 lb. Offset Strap: 3/4" S012 .0850 Ib. 1" S016 .09141b. 11/4" S020 .0998 Ib. 1 1/2" S024 .1196 Ib. 2" S032 .1367 Ib. SHBI Headset - Solid Wood Joist (Designed for use with Central's "West Coast" style CPVC Sprinkler Head Adapter) Step 1 - Position bracket against vertical wood surface Step 2 - Set depth of brackets using graduated markings on bracket depth tab. Desired Location is to be Tined up with bottom of Joist. (See Matrix on page for determining appropriate mark to use.) Press firmly to hold position on face of joist. Step 3 - Secure bracket to wood surface using the two hex head cap screws provided. (#10 x 1" screws) Note: Install two screws as shown below. or No. 19-2.0 Step 4 - Cut and install CPVC sprinkler drop making sure the face of the sprinkler head adapter is flush with inside of Head set cup. Caution: Never install sprinkler head into fitting until CPVC cement has had time to cure. This will prevent possible pooling of glue into the sprinkler orifice. Step 5 - Insert sprinkler head through Headset cup and thread into CPVC Adapter. (see sprinkler head data sheet and the Central BlazeMaster CPVC Installation Instructions and Technical Manual for proper torque requirements) SHBI Headset - Composite Wood Joist (Designed for use with Central's "West Coast" style CPVC Sprinkler Head Adapter) Step 1 - Use pliers to break off tab. Step 2 - Bend Lower tabs in 90° angle. Step 3 - Position Bracket against vertical wood surface such that the desired location on the depth tab is lined up with the bottom of the composite wood joist. (See Table 1 & Fig. 1 or Fig. 2 as appropriate) Step 4 - Secure bracket to wood surface using the two Hex Head cap screws provided. (#10 x 1" screws) Step 5 - Cut and install CPVC sprinkler drop making sure the face of the sprinkler head adapter is flush with inside of Headset cup. Caution: Never install sprinkler head into fitting until CPVC cement has had time to cure. Thiswill prevent possible pooling of glue intothe sprinkler orifice. Step 6 - Insert sprinkler head through Headset cup and thread into CPVC Adapter. (see sprinkler head data sheet and the Central BlazeMaster CPVC Installation Instructions and Technical Manual for proper torque requirements) Offset Two -Hole Strap Step 1 - Snap Strap over CPVC pipe. Step 2 - Squeeze Strap back around pipe. (Note: Pipe must be allowed to slide freely) Step 3 - Fasten the Strap to the wood surface using the two screws provided. (#10 x 1" Hex Head Cap Screws) Typical Installation Utilizing No Block & SHB1 Sprinkler Head Mounting Bracket Composite Wood Joist 2 Solid Wood Joist SHB1 Headset Hanger 2 Hole Offset Hanger 2.713 - S032 (2") 2.475 - S024 (1 10) �! 2.355 - S020 (1 1/4") 1.500 ! 2.183 - S016 (1") TYP ! 2.050 - S012 (3/4") REF I 15° i` TYP 30° TYP 5.000 - S032 4.500 - S024 3.250 - S020 3.250 - S016 3.250 - S012 3 TABLE 1 Depth Tab Selection Guide (also see figures 1 & 2 as appropriate) Ceiling Type Sprinkler ROC LF GBR GBR Concealed 5/8" Gypsum Board Align bottom of TAB 7/16" above bottom of beam TAB "E" TAB "D" 1/2 TAB "A" 5/8" Channel & 5/8" Gypsum Board 1/2 TAB "A" Align bottom of TAB 13/4" below bottom of beam TAB "F" TAB "C" Figure 1 5/8" Gypsum Board Ceiling Depth Tab Positioning ROC 17/16' LF Recessed (Align with Bottom of Beam) GBR Recessed (Align with Bottom of Beam) _GBR Concealed (Align with Bottom of Beam) `Bottom of Beam © 1999 Central Sprinkler Company Printed in U.S.A. Ordering Information When placing an order, indicate the full product name. Please specify the quantity, model, & size. SHB1 Sprinkler Head Mounting Bracket: One size for all Applications (Box Qty: 100) No Block Hanger: Box Qty: • S032 3/4" Strap 100 • S024 1" Strap 100 • S020 1 1/4" Strap 100 • S016 1 1/2" Strap 100 • S012 2" Strap 100 Figure 2 5/8" Channel with 5/8" Gypsum Board Depth Tab Positioning F E D C B A LF Recessed t—(Align with Bottom of Beam) GBR Recessed (Align with Bottom of Beam) GBR Concealed —(Align with Bottom of Beam) ROC !—(Align with Bottom of Beam) CENTRAL Central Sprinkler Company 451 North Cannon Avenue, Lansdale, PA 19446 PHONE (215) 362-0700 FAX (215) 362-5385 Hangers.1 CENTRAL 513, 513D/513R 1-03 Riser Manifold Figure 513, 513D/513R Commercial - NFPA 13 Systems Floor Control - High Rises Residential - NFPA 13D/13R Systems Tyco Fire Products --- www.tyco-grooved.com 451 North Cannon Avenue, Lansdale, Pennsylvania 19446 --- USA Customer Service/Sales: Tel: (215) 362-0700 / Fax: (215) 362-5385 Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-5500 CENTRAL Grooved Piping Products General Description See Fire Protection Submittal Sheet for pressure rating and Listing and Approval information The Figure 513, 513D/513R Riser Manifold provides all of the accessory equipment for a riser in a single assembly. The availability of the Riser Manifold in different configurations allows cost effective riser installation in commercial (NFPA 13) systems, high rises requiring floor control assemblies, and residential systems (NFPA 13D/13R). The threaded ends of the 1" and 1'/2" bodies, the threaded by grooved ends of the 2" bodies, and the grooved ends of the 1'/" - 6" bodies allow for an easy transition to either check or control valves. The exclusive and dedicated flow switch designed for the manifolds has been tested and Listed for use in this specific configuration by Underwriters Laboratories, Underwriters Laboratories of Canada and Factory Mutual. Installation is simplified with one convenient take-out for the 1" and 1V2" threaded and 1'h" grooved versions, as well as one take-out for the 2" threaded by grooved and the grooved sizes 2" - 6". The Riser Manifold is approved for installation in either the horizontal or the vertical position. The optional relief valve assembly is available for locations which require relief valves on gridded systems. Riser Manifolds for use in Canada only are provided with a Water Flow Switch that has a Tamper Switch mounted inside for cover removal detection. 1 Technical Data Figure: 513 (commercial) 513D (residential) 513D/513R (residential) Styles: Threaded or Grooved Sizes: 1", 1'/2", 2", 2'/i , 3", 4" and 6" Approvals: UL, FM, and ULC Maximum Working Pressure: 175 psi Standard Finish: Painted Optional Accessories: Pressure Relief Valve Kit (see page 7) No. 28-1.0 Figure 1 1" Threaded Residential Riser Manifold Figure 513D Approximate Trimmed Weight - 7.5 lbs. (3.4Kg.) The width of the Riser Manifold is approximately 31/2". Note: Items 7 & 8 are used on Manifolds for use in Canada Only Figure 1 - Bill of Material 1" Threaded Residential Riser Manifold * .63 [16] BOTH ENDS Detail No. Description No. Req'd Part Number 1 Manifold Body F x F 1 976-363-01 2 Potter Waterflow Switch # VSR-SF w/Paddle 1 H-416-01 3 Y4" Water Pressure Gauge 1 971-118-02 4 3/a" 90° Street Elbow 1 H-463-075 5 3/4" Close Nipple 1 H-474-12 6 3/4" Ball Valve 1 971-116-02 7 Tamper Switch (ULC only) 1 H-419-01 8 Label (ULC only) 1 976-343-01 Figure 2 11/2" Threaded Residential Riser Manifold Figure 513D/513R Reference Figures 2 and 3 Bill of Materials (page 3) Approximate Trimmed Weight - 8.7 lbs. (3.9Kg.) 9.75 [247.7] *Approximate thread engagement. Note: Values shown in parenthesis are in millimeters * .63 [16] 10 00 The width of the Riser Manifold is approximately 31/2". [254] Note: Items 16 & 17 are used on Manifolds for use in Canada Only. Male x Male Body Option 2.13 [54.1] 2 'Approximate thread engagement. Note: Values shown in parenthesis are in millimeters Figure 3 11/2" Threaded Commercial Riser Manifold Figure 513 For optional pressure relief valve, see Figure 10 (page 7) Approximate Trimmed Weight - 11.2 lbs. (5.1 Kg.) The width of the Riser Manifold is approximately 31/2". Note: Items 16 & 17 are used on Manifolds for use in Canada Only. Male x Male Body Option 12.50 [317.5] 6.25 [158.8] ---�I 14 38 [365.3] 10 00 [254] 1.13 J [28.7] •63 [16] Figures 2 and 3 - Bill of Material 11/2' Threaded Residential and Commercial Riser Manifold .63 [16] 5.50 [139.7] 'Approximate thread engagement. Note: Values shown in parenthesis are in millimeters Detail No. Description No. Req'd Part Com. Res. Number 1 Manifold Body M x F 1 1 976-339-01 2 Potter Waterflow Switch # VSR-SF w/ 11/2" Paddle 1 1 H-416-02 3 1" Ball Valve F101 0 1 971-116-03 4 1" x Y x 1" Reducing Tee 1 0 H-469-100-050-100 5 1° Insp. Test & Drain Valve F202 w/1/2" Test Orifice 1 0 971-122-04 6. Sight Glass M x F 1 0 H-418-100 7 Y4" Water Pressure Gauge 0 1 971-118-02 7a 14" Water Pressure Gauge 1 0 971-118-01 8 Y4" Pipe Plug 1 0 H450-025-000 9 Y4" 3 -Way Globe Valve 1 0 971-119-01 10 1/4" x 3" Nipple 1 0 H-459-025-30 11 1' x /" x 1" California Tee 0 1 976-385-01 12 1/2" Pipe Plug 1 1 H450-050-000 13 1" Close Nipple 0 1 H-474-16 14 1" Bal[ Valve 1 0 971-121-01 15 112" Close Nipple 1 1 H-474-24 16 Tamper Switch (ULC only) 1 1 H-419-01 17 Labe[ (ULC only) 1 1 976-343-01 3 Figure 4 11/2" Grooved Commercial Riser Manifold - Figure 513 For optional pressure relief valve, see Figure 10 (page 7) Approximate Trimmed Weight - 11.2 lbs. (5.1 Kg.) The width of the Riser Manifold is approximately 31/2". Note: Items 12 & 13 are used on Manifolds for use in Canada Only. Figure 4 - Bill of Material 11/2" Grooved Commercial Riser Manifold [28.7] 5.50 [139.7] Detail No. Description No. Req'd Part Number 1 Manifold Body G x G 1 976-399-02 2 Potter Waterflow Switch # VSR-SF w/ 114" Paddle 1 H-416-02 3 1" Ball Valve F101 1 971-121-01 4 1" Insp. Test & Drain Valve F202 w/ 1/2" Test Orifice 1 971-122-04 5 Sight Glass M x F 1 H-418-100 6 '/4" Water Pressure Gauge 1 971-118-01 7 1/4" Pipe Plug 1 H-450-025-000 8 '/4" 3 -Way Globe Valve 1 971-119-01 9 %" x 3" Nipple 1 H-459-025-30 10 1" x'' /2" x 1" Reducing Tee 1 H-469-100-050-100 11 Y2" Pipe Plug 1 H-450-050-000 12 Tamper Switch (ULC only) 1 H-419-01 13 Label (ULC only) 1 976-343-01 Figure 5 2" Grooved Residential Riser Manifold Figure 513D/513R Reference Figures 5 and 6 Bill of Materials (page 5) For optional pressure relief valve, see Figure 10 (page 7) Approximate Trimmed Weight -11.0 lbs. (5.OKg.) The width of the Riser Manifold is approximately 31". Note: Items 16 & 17 are used on Manifolds for use in Canada Only. 13.00 2" Male x Groove Body Option 4 'Approximate thread engagement. Note: Values shown in parenthesis are in millimeters 12.00 [304.8] 5.44 [138.2] 2.25 [57.2] - 'Approximate thread engagement. Note: Values shown in parenthesis are in millimeters Figure 6 2", 21/2", 3", 4", and 6" Grooved Commercial Riser Manifold - Figure 513 For optional pressure relief valve, see Figure 10 (page 7) Approximate Weights and Dimensions of Trimmed 2". 21/2". 3'. 4", and 6" Grooved Commercial Riser Manifolds Size Inches A Inches mm B Inches mm C Inches mm D Inches mm Appx. Width Inches mm Weight Lbs. Kg. 2 17.13 135.0 0.88 22.2 12.88 327.0 5.25 139.7 3.50 88.9 13.5 6.1 21/2 18.13 460.4 1.88 47.6 13.75 349.3 6.38 155.6 3.50 88.9 16.8 7.6 3 18.13 460.4 1.88 47.6 14.38 365.1 6.25 158.8 3.50 88.9 18.7 8.5 4 20.00 508.0 3.75 95.3 17.38 441.3 8.38 212.7 4.50 114.3 32.7 14.8 6 20.00 508.0 3.75 95.3 19.25 489.0 9.25 235.0 6.63 182.3 41.6 18.9 Figure 5 and 6 - Bill of Material 2" Grooved, 2" Threaded x Grooved and 2", 21/2", 3", 4", and 6" Commercial Riser Manifold * Approximate thread engagement. ** 13" is the take-out for all sizes 2" through 6" Note: Values shown in parenthesis are in millimeters Detail No. Description No. Req'd Part Number 1 2" Manifold Body Groove x Groove 1 976-254-01 212" Manifold Body Groove x Groove 1 976-254-02 3" Manifold Body Groove x Groove 1 976-254-03 4" Manifold Body Groove x Groove 1 976-254-04 6" Manifold Body Groove x Groove 1 976-254-05 la 2" Manifold Body Male x Groove 1 976-411-01 2 Potter Waterflow Switch # VSC w/ 2" Paddle 1 976-357-01 Potter Waterflow Switch # VSC w/ 212" Paddle 1 976-357-02 Potter Waterflow Switch # VSC w/ 3" Paddle 1 976-357-03 Potter Waterflow Switch # VSC w/ 4" Paddle 1 976-357-04 Potter Waterflow Switch # VSC w/ 6" Paddle 1 976-357-05 3 1" Bali Valve F101 (2") 1 971-121-01 11/4" Ball Valve F101 (21/2" and 3") 1 971-121-02 2" Ball Valve F101 (4" and 6") 1 971-121-03 4 1" Insp. Test & Drain Valve F202 (2") w/'/2" Test Orifice 1 971-122-04 11/4" Insp. Test & Drain Valve F202 (212" and 3") w/ 1/2" Test Orifice 1 971-122-05 2" Insp. Test & Drain Valve F202 (4" and 6") w/'/2" Test Orifice 1 971-122-06 5 1" Sight Glass (2") 1 H-418-100 1Y*" Sight Glass (21/2" and 3") 1 H-418-125 2" Sight Glass (4" and 6") 1 H-418-200 6 14" Water Pressure Gauge 1 971-118-01 7 Y4" Pipe Plug 1 H-450-025-000 8 Y4" 3 -Way Globe Valve 1 971-119-01 9 1/4" x 3" Nipple 1 H-459-025-30 10 1" Pipe Plug 1 H-450-100-000 1" x'/2" x 1" Reducing Tee (2") 1 H-469-100-050-100 11 11/4" x 12" x 11/4" Reducing Tee (212" and 3") 1 H-469-125-050-125 2" x 12" x 2" Reducing Tee (4" and 6") 1 H-469-200-050-200 12 12" Pipe Plug 1 H-450-050-000 13 1"x 12" x 1" California Tee 1 976-385-01 14 1" Close Nipple 1 H-474-16 15 1" Ball Valve F101 1 971-116-03 16 Tamper Switch (ULC only) 1 H-419-01 17 Label (ULC only) 1 976-343-01 Note: Items 16 & 17 are used on Manifolds for use in Canada Only. 5 Figure 7 Potter Waterflow Switch Terminal Connections Caution: An uninsulated section of a single conductor is not permitted to be looped around the terminal and serve as two separate connections. The wire must be severed to serve as two separate connections, thereby providing supervision of the connection in the event that the wire becomes dislodged from the terminal. Figure 8 Potter Waterflow Switch Typical Electrical Connections Local Bell Transformer or Battery Powered Open on Alarm Signaling Device Close on t Alarm Typical Switch Action Open on Close on Alarm • • Alarm Style B / Class B End of Line Resistor CKT.(see note) Open on Close on Alarm Alarm Supervised Loop (see note) From Open on Close on Control Alarm _ Alarm Panel End of Line Resistor To Additional Devices or Return to Control Note: For supervised circuits, see "Switch Terminal Connections" and caution note (above). The Model VSC and Model VSR-SF have two switches, one can be used to operate a central station, proprietary or remote signaling unit, while the other contact is used to operatea local audible or visual annunciator. Testing: The frequency of testing for the Model VSC and Model VSR-SF and their associated protective monitoring system should be in accordance with applicable NFPA Standards and/or the Authority Having Jurisdiction, but under no circumstances less than bimonthly. Figure 9 Potter Tamper Switch Typical Electrical Connection Contacts S.P.D.T. (form C) N.C. V Contact Rating: 5A@125V AC N.O. 2.5A@30V DC Com. Contacts shown with Cover in Place Installation for Models VSC and VSR-SF: Remove the one retard assembly mounting screw. Place the switch assembly over the retard mounting tab. Replace the screw. 6 Figure 10 Optional Pressure Relief Valve Grooved Commercial Trim - Figure 513 Relief Valve is factory set at 175psi (nonadjustable). Note: If the optional pressure relief kit is desired for Figures 3 and 4, an outlet on the riser must be provided, and the connection and material between the riser and the manifold will need to be supplied and fabricated by the installer. Figure 10 - Bill of Material Optional Pressure Relief Valve Kit NORMALLY CLOSED NORMALLY IN DRAIN POSITION Detail No. Part Number No. Req'd Part Number 1 90° Compression Fitting 2 H-475-050-038 2 12" Watts Pressure Relief Valve Model FP53L (UL, FM) 1 H-476-01 3 Tubing (2") 1 976-419-01 Tubing (212" and 3") 1 976-419-02 Tubing (4" and 6") 1 976-419-03 4 1" x 12" Reducing Bushing 1 H-477-01 M = Male N.P.T. F = Female N.P.T. G = Grooved Connection Optional Figure 513 Pressure Relief Valve Kit Size Part Number 2" 4063 21/2" and 3" 4072 4" and 6" 4073 Size Figure Nuart mber Size Figure Part Number 1" 513D, F x F (UL, FM) 4067 2" 513D/513R, M x G (ULC) 4094 1" 513D, F x F (ULC) 4085 2" 513D/513R, G x G (UL, FM) 4059 11/2" 513D/513R, F x M (UL, FM) 4057 2" 513D/513R, G x G (ULC) 4093 11/2" 5130/513R, M x M (UL, FM) 4058 2" 513, G x G, 12" Test Orifice (UL, FM) 4060 112" 513D/513R, F x M (ULC) 4088 2" 513, G x G, /° Test Orifice (ULC) 4090 11/2" 513D/513R, M x M (ULC) 4089 21/2" 513, G x G,'/2" Test Orifice (UL, FM) 4061 11/2" 513, F x M /' Test Orifice (UL, FM) 4055 21 513, G x G, 1/2" Test Orifice (ULC) 4091 1'/2' 513, M x M 12" Test Orifice (UL, FM) 4056 3" 513, G x G, 12" Test Orifice (UL, FM) 4062 11/2" 513, F x M 1/2" Test Orifice (ULC) 4086 3" 513, G x G, 1/2" Test Orifice (ULC) 4092 11" 513, M x M 12" Test Orifice (ULC) 4087 4" 513, G x G,'/2" Test Orifice (UL, FM) 4065 11/2" 513, G x G 12" Test Orifice (UL, FM) 4056G 4" 513, G x G, Y2" Test Orifice (ULC) 4095 1W 513, G x G 1" Test Orifice (ULC) 4087G 6" 513, G x G, 12" Test Orifice (UL, FM) 4066 2" 513D/513R, M x G (UL, FM) 4064 6" 513, G x G, 12" Test Orifice (ULC) 4096 7 A, Ordering Procedure Ordering Information: When placing an order, indicate the full product name. Please specify the quantity, figure number, style, and size. (see page 7 for figure and part numbers) Availability and Service: Grooved Piping Products, valves, accessories and other products are available throughout the U.S., Canada, and internationally, through a network distribution centers. You may write directly or call 215-362-0700 for the distributor nearest you. a Care and Maintenance The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in accordance with the applicable standards of the National Fire Protection Association (e.g., NFPA 25), in addition to the standards of any authority having jurisdiction. The installing contractor or product manufacturer should be contacted relative to any questions. Any impairment must be immediately corrected. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service. Limited Warranty Products manufactured by Tyco Fire Products are warranted solely to the original Buyer for ten (10) years against defects in material and workmanship when paid for and properly installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment by Tyco Fire Products. No warranty is given for products or components manufactured by companies not affiliated by ownership with Tyco Fire Products or for products and components which have been subject to misuse, improper installation, corrosion, or which have not been installed, maintained, modified or repaired in accordance with applicable Standards of the National Fire Protection Association (NFPA), and/or the standards of any other Authorities Having Jurisdiction. Materials found by Tyco Fire Products to be defective shall be either repaired or replaced, at Tyco Fire Products' sole option. Tyco Fire General Notes: It is the Designer's responsibility to select products suitable for the intended service and to ensure that pressure ratings and performance data is not exceeded. Always read and understand the installation instructions (IH -1000). Never remove any piping component nor correct or modify any piping deficiencies without first depressurizing and draining the system. Material and gasket selection should be verified to be compatible for the specific application. VIC0 I Flow Control I Tyco Fire Products 8 Products neither assumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of products. Tyco Fire Products shall not be responsible for sprinkler system design errors or inaccurate or incomplete information supplied by Buyer or Buyer's representatives. IN NO EVENT SHALL TYCO FIRE PRODUCTS BE LIABLE, IN CONTRACT, TORT, STRICT LIABILITY OR UNDER ANY OTHER LEGAL THEORY, FOR INCIDENTAL, INDIRECT, SPECIAL OR CONSEQUENTIAL DAMAGES, INCLUDING BUT NOT LIMITED TO LABOR CHARGES, REGARDLESS OF WHETHER TYCO FIRE PRODUCTS WAS INFORMED ABOUT THE POSSIBILITY OF SUCH DAMAGES, AND IN NO EVENT SHALL TYCO FIRE PRODUCTS' LIABILITY EXCEED AN AMOUNT EQUAL TO THE SALES PRICE. THE FOREGOING WARRANTY IS MADE IN LIEU OFANY AND ALL OTHER WARRANTIES EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FORA PARTICULAR PURPOSE. Certified Company Printed in U.S.A. 1-03 Single Inlet Connection for Residential Sytems, UL Listed Description Designed specifically residen- tial sprinkler systems, the Single Inlet Connection fea- tures all brass contruction with an intergrally cast mounting/ identification plate. The con- nection comes equiped with a single 1 1/2" NST gasketed female threaded swivel inlet and a 1 1/2" NST plug to portect the threaded swivel from damage or the introduc- tion of foreign materials when not in use. The out let is 1 1/2" NPT female thead for connect to the end of 1 1/2" threaded male pipe. The intergral mounting/identification plate has three drilled mounting holes for attachment to a mounting surface such as an exterior wall of a building or other structure. Fassteners used should be suitable for the material to which the connec- tion is being attached. Installation Install according to applicable codes using customary instal- lation methods for for the installation of threaded con- nections. A suitable threaded sealant such as PipeFit Thread Sealing Paste with PTFE or PTFE thread Sealant Tape should be used. Where required, a check valve should be used to maintain system pressure. fpPt° ©1996-1999 Fire Protection Products, Inc. Specs Material: Brass Type: Single Outlet PL Size: 1.5" FNPT x 1.5 FNST Other specifications: Integral Identification sign "Auto Sprinkler" with mounting holes. For questions: 1 800 344-1822 1 800 344-3775 fax http://www.fppi.com SPECIFICATION SHEET MODEL 850 (1/2" - 2") frz-sco/ BACKFLOW PREVENTION DOUBLE CHECK ASSEMBLY Characteristics Physical Properties Size Max. Working Pressure Hydrostatic Test Press. Temperature Range End Connections Materials Valve Body Elastomers Springs 1/2", 3/4", 1", 1-1/4", 1-1/2", 2" 175 PSI (1200 KPa) 350 PSI (2400 KPa) 32°F to 140°F (0°C to 60°C) Threaded ANSI B2.1 Bronze Silicone Stainless Steel Agency Compliance • ANSI/AWWA Conformance (C510-92) • ASSE Listed (Std. 1015) • CSA • Approved by the Foundation for Cross Connection Control and Hydraulic Research at the University of Southern California. MODEL 850 (1/2" - 2") DOUBLE CHECK ASSEMBLY Application Non -Health Hazard Options 0 Wye - Strainer Model 850 (1/2" 20 Head Loss (PSI) 15 10 5 - 2") Flow Curves 1/2" 0 0 3 6 9 12 15 18 (GPM) 3/4" 20 = 0 20 0 5 10 15 20 25 30 (GPM) 1" Head Loss (PSI) 20 15 10 5 0 0 10 20 30 40 50 60 (GPM) 1-1/4" 20 40 60 80 100 120 (GPM) Head Loss (PSI) Head Loss (PSI) 20 15 10 5 0 20 15 10 5 0 1-1/2" 0 20 40 60 80 100 120 (GPM) 2" 0 30 60 90 120 Installation Recommendations 150 180 (GPM) 12" Minimum Clearance to Fixed Structure Z 12" Minimum 1 Flow MODEL 850 (1/2" - 2") Outdoor Installation Model 850 (1/2" - 2") 41 v SIZE A 1121" 10 (254.00) 1/4" 10114 (273.05) 1" 12112 (317.50) 11/4" 1918 (403.23) 161/4 (415.93) 2" 17518 (447.68) 1112"" Dimensions and Weights U.S. - Inches (mm) B 1112 (38.10) 11/2 (38.10) 1718 (47.63) 3 (76.20) 3 (76.20) 3112 (88.90) C 11/2 (38.10) 11/2 (38.10) 1518 (41.28) 21/2 (63.50) 21/2 (63.50) 21/2 (63.50) D 3% (79.38) 3118 (79.38) 3118 (85.73) 41/4 (107.95) 41/4 (107.95) 41/4 (107.95) NET WT. E Lbs. (kgs.) 11/4 (31.75) 4.2 (1.91) 11/4 (31.75) 4.4 (2.00) 11/2 (38.10) 6.8 (3.08) 2114 (57.15) 15.8 (7.17) 21/4 (57.15) 16.2 (7.35) 2114 (57.15) 21.1 (9.57) Note: Dimensions are nominal. Allowances must be made for normal manufacturing tolerances. FEBCO Backflow Prevention P.O. Box 8070 • Fresno, CA 93747-8070 559 252-0791 • Fax: 559 453-9030 • www.FEBCOonline.com ss850sm 4/02 Copyright 2002 SPX Valves & Controls ITEM DESCRIPTION MATERIALS 1 Body Bronze 1.2 Tailpiece Bronze 1.4 0 -Ring Silicone 2 Cover Bronze 2.2 0 -Ring Silicone 3 Seat Noryl 3.1 0 -Ring Silicone 4 Poppet Noryl 5 Seat Disc Silcone 5.1 Disc Retainer Noryl 5.2 Rnd HD Screw Stainless Steel 6 Spring Stainless Steel 7 Guide Noryl 8 Retainer Spacer Noryl 9 Ball Valve (w/tap) Brozne 9.1 Ball Valve Bronze 11 Test Cock Bronze 21 Hex HD Capscrew Stainless Steel 60 Identification Plate Brass 61 Drive Screw Stick Stainless Steel Model 850 (1/2" - 2") Check Assembly FEBCO is a product of VALVES & CONTROLS" ISO 9001 Certified OEM Vico I Fire & Building Products Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-5500 Gem Customer Service/Sales: Tel: (414) 570-5000 / (800) 558-5236 Fax: (414) 570-5010 / (800) 877-1295 Series LFII Residential Concealed Pendent Sprinklers, Flat Plate 4.2 K -factor General Description The Series LFII (TY2596) Residential Concealed Pendent Sprinklers are decorative, fast response, fusible sol- der sprinklers designed for use in resi- dential occupancies such as homes, apartments, dormitories, and hotels. The cover plate assembly conceals the sprinkler operating components above the ceiling. The flat profile of the cover plate provides the optimum aestheti- cally appealing sprinkler design. In ad- dition, the concealed design of the Se- ries LFII (TY2596) provides 1/2 inch (12,7 mm) vertical adjustment. This adjustment reduces the accuracy to which the fixed pipe drops to the sprin- klers must be cut to help assure a perfect fit installation. The Series LFII are to be used in wet pipe residential sprinkler systems for one- and two-family dwellings and mo- bile homes per NFPA 13D; wet pipe residential sprinkler systems for resi- dential occupancies up to and includ- ing four stories in height per NFPA 13R; or, wet pipe sprinkler systems for the residential portions of any occu- pancy per NFPA 13. The Series LFII (TY2596) has a 4.2 (60,5) K -factor that provides the re- quired residential flow rates at reduced pressures, enabling smaller pipe sizes and water supply requirements. The Series LFII (TY2596) has been designed with heat sensitivity and water distribution characteristics proven to help in the control of residen- tial fires and to improve the chance for occupants to escape or be evacuated. The Series LFII (TY2596) Residential Concealed Pendent Sprinklers are shipped with a Disposable Protective Cap. The Protective Cap is temporarily removed for installation, and then it can be replaced to help protect the sprinkler while the ceiling is being in- stalled or finished. The tip of the Pro- tective Cap can also be used to mark the center of the ceiling hole into plas- ter board, ceiling tiles, etc. by gently pushing the ceiling product against the Protective Cap. When the ceiling in- stallation is complete the Protective Cap is removed and the Cover Plate Assembly installed. WARNINGS The Series LFII (TY2596) Residential Concealed Pendent Sprinklers de- scribed herein must be installed and maintained in compliance with this document, as well as with the applica- ble standards of the National Fire Pro- tection Association, in addition to the standards of any other authorities hav- ing jurisdiction. Failure to do so may impair the integrity of these devices. The owner is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted relative to any questions. Sprinkler/Model Identification Number SIN TY2596 Technical Data Approvals: UL and C -UL Listed. Maximum Working Pressure: 175 psi (12,1 bar) Discharge Coefficient: K = 4.2 GPM/psi1/2 (60,5 LPM/bar1/2) Temperature Rating: 160°F/71°C Sprinkler with 135°F/57°C Cover Plate Vertical Adjustment: 1/2 inch (12,7 mm) Finishes: Cover Plate: Flat White, Bright White, Chrome, or Custom Physical Characteristics: Body Brass Cap Bronze Saddle Brass Sealing Assembly . Beryllium Nickel w/ Teflont Soldered Link Halves Nickel Lever Bronze Compression Screw Brass Deflector Copper Guide Pin Housing Bronze Guide Pins Stainless Steel Support Cup Steel Cover Plate Copper Retainer Brass Cover Plate Ejection Spring . Stainless Steel tDuPont Registered Trademark Page 1 of 4 MARCH, 2003 TFP440 Page 2 of 4 TFP44O Maximum Coverage Area (a) Ft. x Ft. (m x m) Maximum Spacing Ft. (m) Minimum Flow (b) and Residual Pressure For Horizontal Ceiling (Max. 2 Inch Rise for 12 Inch Run) Minimum Flow (b) and Residual Pressure For Sloped Ceiling (Greater Than 2 Inch Rise Up To Max. 4 Inch Rise for 12 Inch Run) Minimum Flow (b) and Residual Pressure For Sloped Ceiling (Greater Than 4 Inch Rise Up To Max. 8 Inch Rise for 12 Inch Run) 160°F/71°C Sprinkler 160°F/71°C Sprinkler 160' F/71 ° C Sprinkler 12 x 12 12 13 GPM (49,2 LPM) 18 GPM (68,1 LPM) 18 GPM (68,1 LPM) (3,7 x 3,7) (3,7) 9.6 psi (0,66 bar) 18.4 psi (1,27 bar) 18.4 psi (1,27 bar) 14 x 14 14 14 GPM (53,0 LPM) 18 GPM (68,1 LPM) 18 GPM (68,1 LPM) (4,3 x 4,3) (4,3) 11.1 psi (0,77 bar) 18.4 psi (1,27 bar) 18.4 psi (1,27 bar) 16 x 16 16 16 GPM (60,6 LPM) 18 GPM (68,1 LPM) 18 GPM (68,1 LPM) (4,9 x 4,9) (4,9) 14.5 psi (1,00 bar) 18.4 psi (1,27 bar) 18.4 psi (1,27 bar) 18 x 18 18 20 GPM (75,7 LPM) 20 GPM (75,7 LPM) N/A (5,5 x 5,5) (5,5) 22.7 psi (1,57 bar) 22.7 psi (1,57 bar) 20 x 20 20 24 GPM (90,8 LPM) 26 GPM (98,4 LPM) N/A (6,1 x 6,1) (6,1) 32.7 psi (2,25 bar) 38.3 psi (2,64 bar) (a) For coverage area dimensions less than or between those indicated, it is necessary to use the minimum required flow for the next highest coverage area for which hydraulic design criteria are stated. (b) Requirement is based on minimum flow in GPM (LPM) from each sprinkler. The associated residual pressures are calculated using the nominal K -factor. Refer to Hydraulic Design Criteria Section for details. TABLE A NFPA 13D AND NFPA 13R HYDRAULIC DESIGN CRITERIA FOR THE SERIES LFII (TY2596) RESIDENTIAL CONCEALED PENDENT SPRINKLER Operation When exposed to heat from a fire, the Cover Plate, which is normally sol- dered to the Support Cup at three points, falls away to expose the Sprin- kler Assembly. At this point the Deflec- tor supported by the Arms drops down to its operated position. The fusible link of the Sprinkler Assembly is com- prised of two link halves that are sol- dered together with a thin layer of sol- der. When the rated temperature is reached, the solder melts and the two link halves separate allowing the sprin- kler to activate and flow water. Design Criteria The Series LFII (TY2596) Residential Concealed Pendent Sprinklers are UL and C -UL Listed for installation in ac- cordance with the following criteria. NOTE When conditions exist that are outside the scope of the provided criteria, refer to the Residential Sprinkler Design Guide TFP490 for the manufacturer's recommendations that may be accept- able to the Authority Having Jurisdic- tion. System Type. Only wet pipe systems may be utilized. Hydraulic Design. The minimum re- quired sprinkler flow rate for systems designed to NFPA 13D or NFPA 13R are given in Table A as a function of temperature rating and the maximum allowable coverage areas. The sprin- kler flow rate is the minimum required discharge from each of the total number of "design sprinklers" as speci- fied in NFPA 13D or NFPA 13R. For systems designed to NFPA 13, the number of design sprinklers is to be the four most hydraulically demanding sprinklers. The minimum required dis- charge from each of the four sprinklers is to be the greater of the following: • The flow rates given in Table A for NFPA 13D and 13R as a function of temperature rating and the maxi- mum allowable coverage area. • A minimum discharge of 0.1 gpm/sq. ft. over the "design area" comprised of the four most hydraulically de- manding sprinklers for the actual coverage areas being protected by the four sprinklers. Obstruction To Water Distribution. Locations of sprinklers are to be in accordance with the obstruction rules of NFPA 13 for residential sprinklers. Operational Sensitivity. The sprin- klers are to be installed relative to the ceiling mounting surface as shown in Figure 3. Sprinkler Spacing. The minimum spacing between sprinklers is 8 feet (2,4 m). The maximum spacing be- tween sprinklers cannot exceed the length of the coverage area (Ref. Table A) being hydraulically calculated (e.g., maximum 12 feet for a 12 ft. x 12 ft. coverage area, or 20 feet for a 20 ft. x 20 ft. coverage area). Installation The Series LFII (TY2596) must be in- stalled in accordance with the follow- ing instructions: NOTES Damage to the fusible Link Assembly during installation can be avoided by handling the sprinkler by the frame arms only (i.e., do not apply pressure to the fusible link Assembly). A leak tight 1/2 inch NPT sprinkler joint should be obtained with a torque of 7 to 14 ft.lbs. (9,5 to 19,0 Nm). A maxi- mum of 21 ft.lbs. (28,5 Nm) of torque is to be used to install sprinklers. Higher levels of torque may distort the sprinkler inlet with consequent leak- age or impairment of the sprinkler. Do not attempt to compensate for in- sufficient adjustment in an Escutcheon TFP44O BODY (1/2" NPT) CAP SADDLE SUPPORT CUP WITH ROLL FORMED THREADS GUIDE PIN GUIDE PIN HOUSING DEFLECTOR THREAD INTO SUPPORT CUP UNTIL MOUNTING SURFACE IS FLUSH WITH CEILING SPRINKLER/SUPPORT CUP ASSEMBLY SEALING ASSEMBLY SPRINKLER WRENCHING AREA COMPRESSION SCREW LEVER SOLDER LINK ELEMENT DEFLECTOR (OPERATED POSITION) RETAINER WITH THREAD DIMPLES EJECTION SPRING SOLDER COVER PLATE/RETAINER TAB ASSEMBLY FIGURE 1 SERIES LFII (TY2596) RESIDENTIAL CONCEALED PENDENT SPRINKLER COVER PLATE Page 3 of 4 Plate by under- or over -tightening the Sprinkler. Readjust the position of the sprinkler fitting to suit. Step 1. The sprinkler must only be installed in the pendent position and with the centerline of the sprinkler per- pendicular to the mounting surface. Step 2. Remove the Protective Cap. Step 3. With pipe thread sealant ap- plied to the pipe threads, and using the W -Type 18 Wrench shown in Figure 2, install and tighten the Sprinkler/Sup- port Cup Assembly into the fitting. The W -Type 18 Wrench will accept a 1/2 inch ratchet drive. Step 4. Replace the Protective Cap by pushing it upwards until it bottoms out against the Support Cup. The Protec- tive Cap helps prevent damage to the Deflector and Arms during ceiling in- stallation and/or during application of the finish coating of the ceiling. It may also be used to locate the center of the WRENCH RECESS if PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 2 W -TYPE 18 SPRINKLER WRENCH 2-1/2" DIA. (63,5 mm) 1/2" NPT 1/2" (12,7 mm) FACE OF THREADED SPRINKLER ADJUSTMENT FITTING COVER- SPRINKLER - RETAINER SUPPORT CUP ASSEMBLY ASSEMBLY 3-3/16" DIA. (81,0 mm) 1/8" GAP (3,2 mm) 3/16" (4,8 mm) 1-15/16"±1/4" — (49,2 mm ±6,4 mm) SPRINKLER - SUPPORT CUP ASSEMBLY OPERATED SPRINKLER COVER PLATE RETAINER MOUNTING SURFACE TIP 1/2" (12,7 mm) 1" (25,4 mm) DISPOSABLE PROTECTIVE CAP DEFLECTOR IN OPERATED POSITION FIGURE 3 SERIES LFII (TY2596) RESIDENTIAL CONCEALED PENDENT SPRINKLER INSTALLATION DIMENSIONS / PROTECTIVE CAP / ACTIVATED DEFLECTOR Page 4 of 4 clearance hole by gently pushing the ceiling material against the center point of the Cap. NOTE As long as the protective Cap remains in place, the system is considered to be "Out Of Service". Step 5. After the ceiling has been com- pleted with the 2-1/2 inch (63 mm) diameter clearance hole and in prepa- ration for installing the Cover Plate As- sembly, remove and discard the Pro- tective Cap, and verify that the Deflector moves up and down freely. If the Sprinkler has been damaged and the Deflector does not move up and down freely, replace the entire Sprin- kler assembly. Do not attempt to mod- ify or repair a damaged sprinkler. Step 6. Screw on the Cover Plate As- sembly until its flange comes in con- tact with the ceiling. Do not continue to screw on the Cover Plate Assembly such that it lifts a ceil- ing panel out of its normal position. If the Cover Plate Assembly cannot be engaged with the Mounting Cup or the Cover Plate Assembly cannot be en- gaged sufficiently to contact the ceil- ing, the Sprinkler Fitting must be repo- sitioned. Care and Maintenance The Series LFII (TY2596) must be maintained and serviced in accord- ance with the following instructions: NOTES Absence of an Escutcheon Plate may delay the sprinkler operation in a fire situation. Before closing a fire protection system main control valve for maintenance work on the fire protection system which it controls, permission to shut down the affected fire protection sys- tem must be obtained from the proper authorities and all personnel who may be affected by this action must be no- tified. Sprinklers which are found to be leak- ing or exhibiting visible signs of corro- sion must be replaced. Automatic sprinklers must never be painted, plated, coated, or otherwise altered after leaving the factory. Modi- fied or over heated sprinklers must be replaced. Care must be exercised to avoid dam- age - before, during, and after instal- lation. Sprinklers damaged by drop- ping, striking, wrench twist/slippage, or the like, must be replaced. The owner is responsible for the in- spection, testing, and maintenance of their fire protection system and de- vices in compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. The in- stalling contractor or sprinkler manu- facturer should be contacted relative to any questions. NOTE The owner must assure that the sprin- klers are not used for hanging of any objects and that the sprinklers are only cleaned by means of gently dusting with a feather duster; otherwise, non- operation in the event ofa fire or inad- vertent operation may result. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service. Limited Warranty Products manufactured by Tyco Fire Products are warranted solely to the original Buyer for ten (10) years against defects in material and work- manship when paid for and properly installed and maintained under normal use and service. This warranty will ex- pire ten (10) years from date of ship- ment by Tyco Fire Products. No war- ranty is given for products or components manufactured by compa- nies not affiliated by ownership with Tyco Fire Products or for products and components which have been subject to misuse, improper installation, corro- sion, or which have not been installed, maintained, modified or repaired in ac- cordance with applicable Standards of the National Fire Protection Associa- tion, and/or the standards of any other Authorities Having Jurisdiction. Mate- rials found by Tyco Fire Products to be defective shall be either repaired or replaced, at Tyco Fire Products' sole option. Tyco Fire Products neither as- sumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of products. Tyco Fire Products shall not be responsible for sprinkler system design errors or inaccurate or incomplete information supplied by Buyer or Buyer's representatives. IN NO EVENT SHALL TYCO FIRE PRODUCTS BE LIABLE, IN CON- TRACT, TORT, STRICT LIABILITY OR TFP440 UNDER ANY OTHER LEGAL THE- ORY, FOR INCIDENTAL, INDIRECT, SPECIAL OR CONSEQUENTIAL DAMAGES, INCLUDING BUT NOT LIMITED TO LABOR CHARGES, RE- GARDLESS OF WHETHER TYCO FIRE PRODUCTS WAS INFORMED ABOUT THE POSSIBILITY OF SUCH DAMAGES, AND IN NO EVENT SHALL TYCO FIRE PRODUCTS' LI- ABILITY EXCEED AN AMOUNT EQUAL TO THE SALES PRICE. THE FOREGOING WARRANTY IS MADE IN LIEU OF ANY AND ALL OTHER WARRANTIES EXPRESS OR IMPLIED. INCLUDING WARRANTIES OF MERCHANTABILITY AND FIT- NESS FOR A PARTICULAR PUR- POSE. Ordering Procedure When placing an order, indicate the full product name. Contact your local dis- tributor for availability.. Sprinkler Assembly: Series LFII (TY2596), K=4.2, Residen- tial Concealed Pendent Sprinkler with- out Cover Plate Assembly, P/N 51-122-1-160. Cover Plate Assembly: Cover Plate Assembly having a (spec- ify) finish for the Series LFII (TY2596), K=4.2, Residential Concealed Pen- dent Sprinkler, P/N (specify). Chrome P/N 56-122-9-135 Off White P/N 56-122-0-135 Bright White P/N 56-122-4-135 Flat White P/N 56-122-5-135 Custom P/N 56-122-X-135 Sprinkler Wrench: Specify: W -Type 18 Sprinkler Wrench, P/N 56-000-1-265. TYCO FIRE PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19446 HYDRAULIC DESIGN INFORMATION SHEET Name: Darling Residence Location: 2307 South Steen Road Veradale, WA 99037 Budding: Private Residence Contractor: File Name: RD-SL.the Construction: Combustible Occupancy: Residential AHJ: Spokane Valley Fire Department Date: July 02, 2003 System No.: Second Level Contract No.: Drawing No.: FP -1 Calculated by: Steve Leonard 0 Noncombustible Ceiling Height: ❑ NFPA 13: Figure: O Other (Specify): NFPA 13D ❑ Specific Rulling: Made By: 0 Light Hazard Area of Sprinkler Operation: Density: Area per Sprinkler: Hose Allowance Inside: Hose Allowance Outside: Rack Sprinkler Allowance: SYSTEM DESIGN 9ft ❑ Ordinary Hazard Group: 0 Extra Hazard Group: Curve: sqft gpm/sqft 256 sqft 0 gpm gpm gpm Flow Required: 32.64 gpm "C" Factor Used: Overhead: 150 WATER FLOW TEST Date: Time: Static: 60 psi Residual: 50 psi Flowing: 1180 gpm Elevation: 0 ft Date: System Type: ❑x Wet 0 Dry 0 Deluge 0 Pre -Action SPRINKLER or NOZZLE Make: GEM Model: LFII Concealed Size: 1/2 in K -factor: 4.2 Temperature Rating: 155 °F CALCULATION SUMMARY Pressure Required: 41.27 psi Underground: 150 WATER SUPPLY PUMP DATA Rated Capacity: At: Elevation: Location: Hydrant @ S/W corner of 23rd & Steen Source of Information: Valley Fire Dept. Commodity: Storage Height: Storage Method: Solid Pile: gpm psi ft COMMODITY STORAGE Class: Area: Palletized: ❑ Single Row ❑ Double Row ❑ Multiple Row FLUE SPACING Longitudinal: ❑ Conventional Pallet ❑ Slave Pallet in Transverse: Horizontal Barriers Provided: RACK STORAGE D Automatic Storage ❑ Solid Shelving O Open in At: Supply Main TANK OR RESERVOIR Capacity: gals Elevation: ft WELL Proof Flow: gpm Location: Aisle Width: Rack: ❑ Encapsulated ❑ Nonencapsulated CLEARANCE FROM TOP OF STORAGE TO CEILING ft in File: RD-SL.the WATER SUPPLY INFORMATION: Static (psi): Residual (psi): @ (gpm): Hose (gpm): 60.00 50.00 1,180.00 0.00 System req. (gpm): 32.64 @ (psi): 41.27 Supply available: Safety margin: 59.99 psi 18.72 psi Hydraulic Summary Maximum velocity in the system is: 11.00 ft/sec in the pipe between Nodes: 4 and SL Continuity at all nodes satisfied to: 0.01 gpm Pipe Type Legend Fitting Type Legend CP = Central - BlazeMaster CPVC T = Tee (flow turned 90 degrees 40 = Schedule 40 E = 90 degree standard elbow NOTES: SPOKANE VALLEY FIRE DEPT. Approved As Noted Date: 0 `v: 07/02/03 Page 1 of 1 "THE" Sprinkler Program 2001 File: RD-SL.the Node Pressure Flow Hose Elevation K -factor Area Density psi gpm gpm feet gpm/(psi)% sgft gpm/sgft 1 14.51 15.99 24.000 4.20 256.00 0.062 2 15.74 16.65 24.000 4.20 256.00 0.065 3 15.78 0.00 24.000 4 17.55 0.00 24.000 SL 18.87 0.00 24.000 ML 24.22 0.00 13.000 BL 30.44 0.00 0.000 TOR 31.81 0.00 0.000 BFI 38.12 0.00 0.000 BFO 32.37 0.00 0.000 BOR 38.48 0.00 0.000 SRC 41.27 32.64 0.000 Source Page 1 of 1 07/02/03 "THE" Sprinkler Program 2001 File: RD-SL.the Node Node Flow K -factor Elevation Pressure Diameter Length Fric Loss Node Node Flow K -factor Elevation Pressure HWC Fittings Eqv Length Elev Loss Pipe Flow Velocity Ttl Length Ttl FL 1 2 2 3 3 4 2 4 15.99 4.20 24.00 14.51 1.101 16.65 4.20 24.00 15.74 150 T,E 15.99 5.39 14.000 0.045 13.388 0.00 27.390 1.23 16.65 4.20 24.00 15.74 1.101 1.000 0.040 0.00 24.00 15.78 150 0.000 0.00 14.99 5.05 1.000 0.04 0.00 24.00 15.78 1.101 0.00 24.00 17.55 150 2E,T 14.99 5.05 16.65 4.20 24.00 15.74 1.101 0.00 24.00 17.55 150 E,T 17.65 5.95 27.000 0.040 17.213 0.00 44.210 1.76 20.000 0.054 13.388 0.00 33.390 1.80 4 0.00 24.00 17.55 1.101 4.000 0.168 SL 0.00 24.00 18.87 150 E 3.825 0.00 32.64 11.00 7.830 1.32 SL 0.00 24.00 18.87 1.394 11.000 0.053 ML 0.00 13.00 24.22 150 0.000 4.77 32.64 6.86 11.000 0.59 ML 0.00 13.00 24.22 1.394 11.000 0.053 BL 0.00 0.00 30.44 150 0.000 5.63 32.64 6.86 11.000 0.59 BL 0.00 0.00 30.44 1.598 15.000 0.027 TOR 0.00 0.00 31.81 150 2E,2T 34.968 0.00 32.64 5.22 49.970 1.37 TOR 0.00 0.00 31.81 1.610 10.000 0.040 BFO 0.00 0.00 32.37 120 E 4.000 0.00 32.64 5.14 14.000 0.56 BFI 0.00 0.00 38.12 1.610 3.000 0.040 BFO 0.00 0.00 32.37 120 0.000 0.00 32.64 5.14 3.000 5.75 The Flow Dependent Pressure Loss Device in this pipe accounts for 5.63 psi of the total friction Toss. BFI 0.00 0.00 38.12 1.610 5.000 0.040 BOR 0.00 0.00 38.48 120 E 4.000 0.00 32.64 5.14 9.000 0.36 BOR 0.00 0.00 38.48 1.598 75.000 0.027 SRC 32.64 Source 0.00 41.27 150 T,15 26.656 0.00 32.64 5.22 101.660 2.79 Page 1 of 2 07/02/03 "THE" Sprinkler Program 2001 File: RD-SL.the Node Node Flow K -factor Elevation Pressure Diameter Length Fric Loss Node Node Flow K -factor Elevation Pressure HWC Fittings Eqv Length Elev Loss Pipe Flow Velocity Ttl Length Ttl FL Units Legend Flow = gpm Velocity = ft/sec Fric Loss = psi/ft Elevation = feet Length, Elev Loss, Pressure = psi Eqv Length, Ttl FL = psi Diameter = inches Ttl Length = feet 07/02/03 Page 2 of 2 "THE" Sprinkler Program 2001 Water Supply vs. Sprinkler Demand CO O co O M O (isd) aJnssaJd O N O E m 0 LL 1 FUTURE FLAY/ FAMILY RM 24'-2' x 13'-6' FUTURE EXERCISE RM F NTURE BATH B TH � .A/s � 1 10'-6' a FUTURE HOME p THEATER ROOM 1 20'-!0' >: 12'-5' co -._® iSEE RISER DETAIL A' fORAGE/UTILITY 11'-2' .: 14'-9' ±75' OF 1-1/2' POLY PIPE TO I' METER & SUPPLY MAIN I UNEINI"HET) SQUARE FOOTAGE 1364 �sq ft BASEMENT PIPING PLAN SCALE: 1 /8" = 1.1 0" General Notes 1. SPRINKLER SYSTEM DESIGN SHALL MEET REQUIREMENTS OF NFPA #13D, UBC, AND THE LOCAL (AHJ). 2. SIMPLEXGRINNELL'S CONTRACT TO INCLUDE ALL DESIGN (INCLUDING APPROVAL BY IDAHO STATE FIRE MARSHAL AND MATERIAL FOR FIRE SPRINKLER SYSTEM. SYSTEM INSTALLATION IS TO BE DONE BY OTHERS. 3. EXCLUSIONS TO SIMPLEXGRINNELL'S CONTRACT ARE INSTALLATION, PAINTING OF PIPE, WIRING OF ELECTRICAL DEVICES, 4. ALL NEW PIPING IS TO BE CPVC WITH CPVC FITTINGS UNLESS NOTED OTHERWISE. 5. ALL EXPOSED PIPING TO BE AWED XL STEEL PIPE WITH CAST IRON FITTINGS. EXPOSED STEEL PIPING ON THE SERMCE SIDE OF THE BACKFLOW PREVENGER IS TO BE GALVANIZED SCHEDULE 40 WITH GALVANIZED FITTINGS. I CPVC Piping Installation Requirements j LINES - CPVC (CHLORINATED POLYVINYL CHLORIDE) PIPE FIELD CUT TO THE LENGTHS INDICATED ON THE PLAN, ENDS FIELD CLEANED, CHAMFERED AND DEBURRED, FIELD JOINED UTILIZING A COMBINATION OF SOLVENT & CEMENT IN ACCORDANCE WITH MANUFACTURERS INSTRUCTIONS. UTILIZED FOR WET -PIPE SYSTEMS ONLY. HANGERS - PIPE HANGERS SHALL BE SIZED, SPACED AND INSTALLED AS REQUIRED BY NFPA STANDARDS. NO OTHER PIPING AND/OR DEVICES ARE TO BE ATTACHED TO THE SPRINKLER PIPE HANGER SYSTEM UNLESS THE HANGER HAS BEEN SPECIFICALLY DESIGNED FOR THE ADDITIONAL LOADING. THIS CONTRACT DOES NOT INCLUDE ANY MATERIAL OR DEVICES TO IMPROVE THE STRUCTURAL STRENGTH OF THE BUILDING TO ENABLE IT TO CARRY THE LOAD OF THE FIRE PROTECTION SYSTEM. SEE DETAILS ON THIS SHEET FOR THE SPECIFIC HANGER ASSEMBLIES USED FOR THIS INSTALLATION. TABLE 4-6.2.2.1 MAXIMUM DISTANCE BETWEEN HANGERS (FT - IN) PIPE TYPE NOMINAL PIPE SIZE ( IN. ) CPVC 3/4 1 114 112 2 212 3 5-6 6-0 6-6 7-0 8-0 9-0 10-0 NFPA 13D Sprinkler Head Location Requirements LOCATION OF SPRINKLERS PER NFPA 13R SPRINKLERS SHALL BE INSTALLED IN ALL AREAS: EXCEPTION NO. 1: SPRINKLERS SHALL NOT BE REQUIRED IN BATHROOMS WHERE THE AREA DOES NOT EXCEED 55 SQ. FT AND THE WALLS AND CEILINGS, INCLUDING BEHIND FIXTURES, ARE OF NONCOMBUSTIBLE OR LIMITED COMBUSTIBLE MATERIALS PROVIDING A 15 MINUTE THERMAL BARRIER. EXCEPTION NO. 2: SPRINKLERS ARE NOT REQUIRED IN CLOTHES CLOSETS, LINEN CLOSETS, AND PANTRIES W9THIN THE DWELUNb UNITS WHERE THE AREA OF THE SPACE DOES NOT EXCEED 24 SQ. FT. AND THE LEAST DIMENSION DOES NOT EXCEED 3 FT. AND THE WALLS AND THE CEILING ARE SURFACED WITH NONCOMBUSTIBLE OR LIMITED COMBUSTIBLE MATERIALS AS DEFINED BY NFPA 220, STANDARD ON TYPES OF BUILDING CONSTRUCTION. EXCEPTION NO. 3: SPRINKLERS ARE NOT REQUIRED IN ANY PORCHES, BALCONIES, CORRIDORS AND STAIRS THAT ARE OPEN AND ATTACHED. EXCEPTION NO. 4: SPRINKLERS ARE NOT REQUIRED IN ATTICS, PENTHOUSE EQUIPMENT ROOMS, CRAWL SPACES, FLOOR/COUNG SPACES, ELEVATOR SHAFTS, AND OTHER CONCEALED SPACES THAT ARE NOT USED OR INTENDED FOR LIVING PURPOSES OR STORAGE. i BUILDING ELEVATION NTS ALUMINUM RAILING WITH GLASS PANELS --- .0 COVERED BECK 1s• -or ;: 1r -u• NO A/S MIL'/ ROOM I BREAKFAST M CLOSET BEDRO H 2 '-D' x 16• o' / / I NOOK ` ATE' BUPr� — P�-'W %''0' x -i 1'-5' s lt'-?' � , 30'--0' s 16'-D' „ , KITCHEN --I LAUitURY o P'iP•S T, . }IAT \ / / i n `o' r^ x ±:r -G' s' -!D' :. -D' r r , :]'']t' x 12._i, u7 uveas / i • e I r r O • • aurc I •o I _. , Thr/L / 0 i / t 12 / N i t e i@.➢iNL S10 -1F F------ I/t ___ "' (p_ n ,� (3-0)♦c1' 91 STORAGE I I I • �r O ---- • / 2-0) (13-0)' - (8-0) , N (Z-0) 1 �i '� NO I 1 8•-0 / / i co n I' •` ._.= I I /( -v r ------110-P (i (� 6 (6-9) • (1-3) BATH 13 e^n 1 I / L---- --- --- NQ A./S r v f o L o ----------------------------- S r / / J TWO 'TORY 8(0.9) SECOND LEVEL RESIDENTIAL CALC I Vz EidTRY THIS AREA HAS BEEN HYDRAUUCALLY F s' °' " i5 -s' o CALCULATED BASED ON (2) SPRINKLERS 1 • • t0 FLOWING, SPACED 16' x 16' (1-0) 9-4) O(1-10 1-10 (9- - -0) o I 4 • 3+ CAR GARAGE N cD —D 34'--l' x 24'-ri' • BEDROOM 3 1 / / NO r•/S oU 1+'-5' >: ll' -4' / AEN FORMAL ;B1hIIF1G 7'-4y' - OPEN TO BELOW / P.EUROUM 4 PozcH r----------� No t2•_0` .. t2'--tn, - M- .A /_ e r-------------------� I I MAIN LEVEL RESIDENTIAL CALC I I I 1 THIS AREA HAS BEEN HYDRAULICALLY CALCULATED BASED ON (2) SPRINKLERS I ROWING, SPACED 16' x 191 S FINISHED SQUARE FOOTAGE 1200 sq 6t SECOND FLOOR PIPING PLAN SCALE 1/80 = 1'-0" 12 Riser Detail A NTS Riser Legend ( 112" DOMESTIC SERVICE (BY OTHERS) (: 112" FEBCO 850 DCVA (OR APPROVED EQUAL) O3 112' CENTRAL MODEL 513D RISER MANIFOLD WITH FLOW SWRCH, PRESSURE GAUGE, AND 1" TEST & DRAIN (PIPE OUTSIDE TO AN ACCEPTABLE LOCATION) ® 112" PIPING TO SYSTEM (D 6"0, 120VAC ELECTRIC BELL WITH WEATHERPROOF BACKBOX (VERIFY LOCATION WITH OWNER) NOTE: ALL EXPOSED RISER PIPING TO BE STEEL WITH CAST IRON FITTINGS ALL EXPOSED PIPING BETWEEN DOMESTIC SERVICE AND BACKFLOW IS TO BE GALVANIZED SCHEDULE 40 WITH GALVANIZED FITTINGS BUILDING SECTION SCALER/8"=1'-0" Vicinity Map NTS NORTH I I - - - - - - - - - - - - - - - - - - - j FINISHED SQUARE FOOTAGE 1366 sq Ft MAIN FLOOR PIPING PLAN SCALE: 1/8" = 1'-0" SPOKANE VALLEY FIRE DEPT. Approved As Noted Date: 2-22-23 B FTI-h,A,1 0 •� CPVC PIPE STRAP CPVC PIPE 0 O HEX HEAD SELF TAPPING SCREW DOUBLE FASTENER CPVC PIPE STRAP HANGER APPLICATION PIPE HEX HEAD SELF TAPPING SCREW T jv SINGLE FA CPVC PIPE RECEUVE JUL 18 2003 D 0 i0ILn8M BATT INSUL SPRINKLER PIPING PLASTIC VAPOR WOOD TRUSS BARRIER; BOT CHORD (BY OTHERS}x �'..tia �s>,n>� Lv's r-'D•r)n"/ L � '�� C�T hil' l •r. rr��tr Yr.r l�`��>ttivy J7'rr�'Y��•,Y/�i PIPING DETAIL 1 - ATTIC PIPING INSULATION _T \—FLOOR DECKING NO BLOCK" CPVC HANGER WOOD JOIST OR TJI CPVC "NO BLOCK" HANGER RESIDENTIAL I SPRINKLER SPACING TABLE CO CEALED PENDENT (GEM MODEL #LFII —7/16" ORIFICE) PIPE SIZED CALC'D USING THIS SPACING SPRINII((LER SPACING (h)AXIMUM) SPRINKLER LOCATION MAX. (FROM SIDE WALLS) SPRINKLER DESIGN DISCHARGE TO 2:12 SLOPE 3:12 TO 8:12 SLOPE K -FACTOR H ZW w X� PLAN SYMBOL I FEET FEET GPM @ PSI GPM @ PSI U.S. NCL 12X12 6 13.0@9.6 18.0@18.4 4.2 N¢ O t X 14 7 14.0 @ 11.1 18.0 @ 18.4 4.2 O• 16X16 8 16.0@14.5 18.0@18.4 4.2 18X18 9 20.0@22.7 NA 4.2 I �® SCALE 1/8'=1'-0' ` SPRINKLER SYMBOL LEGEND J RESIDENTIAL CONCEALED PENDENT H ZW w X� m mm i NCL N¢ O I� TOTAL. R m I �® SCALE 1/8'=1'-0' ` J H ZW w X� m mm i NCL N¢ O I� 'i o U co O V O 0 04 LIZ � rn (O to mccoo� �\ LO to 2 U)m oo= OL ® Y� N U Wcj Z ca� a�-0 w E o U) In LL W z O F- CL U rn W 0 z O U) W W 0 0 z � U wa WO IY m W M W V � U � a �Q 00 A 4> DRAWN BY: DATE: SL 6/23/03 APPROVED B DATE: PROJECT NUMBER: SHEET TITLE: FIRE SPRINKLER PLAN SHEET NUMBER: FP -1 1 OF 1