Loading...
2013, 01-17 Permit App: BLD-2013-0072 Pole BldgSilage _Valley° Community Development Residential Construction Permit Application 1 C.,11111L 11703 E Spr e Ave, Suite B-3 Spokane V , WA 99206 (509)688-0 FAX: (509)688-0037 www. sp okanevaI I ey. org 1/ PERMIT NUMBER: 4110 PERMIT FEE: New Construction Accessory Bldg (l Addition/Remodel Deck Other: SITE ADDRESS: 1 ti at) S E. Sc,wwny 5; cit ASSESSORS PARCEL NO: `1 S a G a • c, 0 3LEGAL DESCRIPTION: Building Owner: Name: Address: 1 1,3 0 V 6- i t ,44/,Au Name: Phone: or a a _ `(3 t3 4 " Fax: 9,,,a 4 _ e(G 6, Contractor Lic No: Exp Date: ` cL�taLLt1C i �3�3�5 �°"�.��' Address: 1 y a 0 S E, S u✓1/4„/ S coke_ City: 5(lo ll.r. ,,,t >J, IA e y DECK/COV. PATIO SQ. FTG: State: w A Zip: 950-1.7 Phone:7o - roO(6 CONSTRUCTION TYPE: Fax: Contact Person Name: L+ i•(`v 0, l3 ct.LI e aero-kci Phone: y .3 S- 3 a l < 43C -3s?7 Describe the scope of work in detail: i,A Contractor: 3 u ((do cc -_,,,„4 1C C t O f,S : 1-1 Name: Address: 1 1,3 0 V 6- i t ,44/,Au City: .spovim 1.)0,_ 1 / e_ ` State: w ,_ Zip: c{ Phone: or a a _ `(3 t3 4 " Fax: 9,,,a 4 _ e(G 6, Contractor Lic No: Exp Date: ` cL�taLLt1C i �3�3�5 �°"�.��' City Business Lic. No: 0 O a. -7 .y 0 ) a 1 Cost of Project: S 30r .)(3-' %<I 4' (36 I t_ Id (AM ?ronosed Use: Sc/ W cao IA S Vto P **************The following MUST be complete: (write N/A if not annlicablel********************* HEIGHT TO PEAK: d ' DIMENSIONS: 30- >'` 33 n l LI # OF STORIES: i TOTAL HABITABLE SPAC 990 MAIN FLOOR TO SQ. FTG: 0 2"" FLOOR SQ. FTG: UNFIN BASEMENT SQ. FTG: IMPERVIOUS SURFACE AREA: FINISHED BASEMENT SQ. FTG: GARAGE SQ. FTG: DECK/COV. PATIO SQ. FTG: 30% SLOPES ON PROPERTY: # OF BEDROOMS: CONSTRUCTION TYPE: HEAT SOURCE: SEWER OR SEPTIC? The permitee verifies, acknowledges and agrees by their signature that: 1) If this permit is for construction of or on a dwelling, the dwelling is/will be served by potable water. 2) Ownership of this City of Spokane Valley Permit inure to the property owner. 3) The signatory is the property owner or has permission to represent the property owner in this transaction. 4) All construction is to be done in full compliance with the City of Spokane Valley Development Code. Referenced codes are available for review at the City of Spokane Valley Permit Center. 5) This City of Spokane Valley Permit is not a permit or approval for any violation of federal, state or local laws, codes or ordinances. 6) Plans or additional information may be required to be submitted, and subsequently approved beton this application can be processed. SIGNATURE: Method of Payment. ❑ Cash Bankcard #: Authorized Signature: REVISED 2/15/07 0 Check ❑ Mastercard Expires: DATE: 0 VISA VIN#: ,o. Zo73-107Z' NAME' °cA-Je-- • ADDRESS. 41( el • e (._.( 6 Pi 1'( c),0 _5 .Ccky v Ct e LEGAL. PARCELN- cf Customer Information 1164 -Ac -1 ,hi' - CustomerName bpku s; tV i s c. Address P-1 Dc) S e cc,axik (Jr, City, State, Zip V't'-u'ctcLte Building Site Address City O Home Phone Vyferk Phone f'°CeO Phone (S `1) 7e) 1 . 60 ( 6 Directions to Site County State Zip f1 33 1 f 1 ,; 3 t crlv{5TU Cs+ Sacs 4 km. cid SC l a .ek ® Use this symbol to mark two (2) corners (one side or one end) of the building.Thest two (2) corners should also be marked at the building site.The building crew will use these to place the building. Indicate any and all critical alignment issues related to placement of building. NOTES FOR FLOOR PLAN 0 INTERI❑R FRAME WOOD POSTS, SEE POST SCHEDULE THIS SHEET GABLE END WALL POSTS — 6' X 6° TYPICAL DOOR POSTS — 4' X 6' TYPICAL F❑❑TING DIMENSIONS, B = 1'-8'; D = 3'-0" MAXIMUM POST SPACING 12'-0° 0 PURLINS @ 24' ❑.C,, BEARING OR J❑IST HANGERS (TYPICAL) Q p J w J IL N 0_ O 2 1- 1.3 z w J w CKw N PSF LIVE LOAD 50 PSF LIVE LOAD 12' TO 60' SPANS ti DOUBLE TRUSSES ,NOTE: THESE PLANS DO NOT ADDRESS OPEN (CANOPY) BUILDINGS. OTHER VARIATIONS FROM THE PLANS (ROOF PITCH, LARGER OPENINGS, MULTIPLE BUILDINGS, ETC. WILL REQUIRE ACTION BY THE ENGINEER. @19.2'❑,C,- D i—nnIVIBLE TRUSSES A SINGLE TRUSS PLAN VIEW N.T.S. WAMBEKE ENGINEERING panlel Waribeke. P. E. grolg41, V6k't9` TO 509-443-6196 Fax' 309-448-6392 e-nMchratbekeltraricen BUILDING PLAN VIEW - 50 PSF LIVE LOAD STANDARD POST FRAME BUILDING PLANS BULLDOG CONTRACTORS, INC. 11308 E. 11TH AVENUE SPOKANE VALLEY. WA 99206 DRAWN BY DATE WAMBEKE 2-24-08 APPROVED SCALE NTS BULLDOG-IBC01 4 z J 0 l7 z 2 O 0 LL W W J W NOTES FOR SECTION A -A Sl TYPICAL PURLIN, SEE FLOOR PLAN FOR SIZE S2 TRUSS DESIGN BY OTHERS S3 2' X 6' @ 24' 0. C., 10' BAYS DF -L #2 GIRTS FLAT @ 24' O.C. 2' X 6' @ 24' 0. C., 12' BAYS DF -L #2 GIRTS FLAT @ 24' O.C. 0 CONCRETE FOOTING, SEE SCHEDULE S5 EXTEND POST TO TOP OF PURLIN ROOF FASTENED TO PURLINS WITH 1 1/2' LONG WOODFAST TEKS. WALLS FASTENED TO GIRTS WITH 1' LONG WOODFAST TEKS. A S3 :•• SEE FOOTING DETAIL '446i LB BUILDING SECTION A - A N.T.S. WAMBEKE ENGINEERING Daniel Warobeke, P. E. Tzarv 9m` TW 509-443-6186 Fax' 509-448-658 e-,aI STANDARD BUILDING SECTION STANDARD POST FRAME BUILDING PLANS BULLDOG CONTRACTORS, INC. 11308 E. 11TH AVENUE SPOKANE VALLEY. WA 99206 DRAWN DT DATE WAMBEKE 2-24-08 APPROVED SCALE NTS BULLDOG—IBCO2 REV. BUILDING SPECIFICATIONS: GENERAL — ALL BUILDING CONSTRUCTION SHALL CONFORM TO THE 2009 EDITION OF THE INTERNATIONAL BUILDING CODE (IBC 2009), AND ALL STATE & LOCAL BUILDING CODES. THESE SPECIFICATIONS AND PLANS ARE INTENDED FOR USE IN 50 PSF LIVE LOAD, 85 MPH WIND SPEED, EXPOSURE B AND SEISMIC DESIGN CATEGORY C. DESIGN LOADS — ROOF LIVE LOAD = 50 PSF ROOF DEAD LOAD = 5 PSF* CEILING LIVE LOAD = 0 PSF CEILING DEAD LOAD = 1 PSF * ROOF DL ALLOWS FOR A MAXIMUM OF 3" THICKNESS OF FIBERGLASS INSULATION. * MAXIMUM SOIL BEARING PRESSURE = 2,000 PSF MAXIMUM SOIL BEARING PRESSURE IS BASED ON SAND, SILTY SAND, CLAYEY SAND, SILTY GRAVEL AND CLAYEY GRAVEL SOILS OR BETTER BASED ON IBC TABLE 1806.2. LESSER SOIL CONDITIONS WILL REQUIRE REVIEW AND FOOTING SIZE ADJUSTMENT BY THE ENGINEER. CONCRETE — MINIMUM 28 DAY COMPRESSIVE STRENGTH F'c = 2,000 psi, 4 SACK MIX FOR FOOTINGS. CAST IN PLACE CONCRETE CONSTRUCTION SHALL CONFORM TO ACI 318-08. WOOD — STRUCTURAL LUMBER SHALL CONFORM TO DF—L #2 OR BETTER BY WWPA GRADING RULES. MAXIMUM MOISTURE CONTENT SHALL BE 19% BY WEIGHT. NAILING SHALL CONFORM TO TABLE 2304.9.1 FASTENING SCHEDULE & OTHER APPROPRIATE SECTIONS OF CHAPTER 23 OF THE IBC. ALL NAILS INTO PRESERVATIVE TREATED WOOD SHALL BE HOT—DIPPED ZINC COATED GALVANIZED STEEL, SILICONE BRONZE, COPPER OR STAINLESS STEEL. CCA TREATED WOOD SHALL CONFORM TO THE REQUIREMENTS OF AWPA STANDARDS C-16, C-22, C-23, C-24 & C-28. POSTS FOR BUILDINGS SHALL BE AS NOTED ON THE PLANS. ALL POST MATERIALS SHALL BE HEM—FIR #2 OR BETTER, FULL DIMENSION AND GRADED BY WWPA GRADING RULES. HARDWARE SHALL BE SIMPSON OR APPROVED EQUAL. ALL BOLTS SHALL CONFORM TO ASTM A307. METAL PANELS MAY BE DELTA RIB STYLE, GALVANIZED OR PAINTED, 29 GAUGE THICKNESS, ASTM A653 STRUCTURAL QUALITY (SQ), Fy = 80.0 ksi. ROOF PANELS SHALL BE FASTENED TO PURLINS WITH PLATED, GASKETED 1 1/2" LONG METAL TO WOOD FASTENERS. WALL PANELS SHALL BE FASTENED TO GIRTS WITH PLATED, GASKETED 1" OR LONGER METAL TO WOOD FASTENERS. PANELS SHALL BE INSTALLED AND FASTENED ACCORDING TO THE MANUFACTURER'S RECOMMENDATIONS. ALTERNATE ROOFING & SIDING APPLICATIONS — BUILDING ROOF MAY BE SHEETED WITH 15/32" 0.S.B. BOARD, 1/2" C—DX PLYWOOD OR OTHER APA RATED SHEETING, NAILED 6" 0. C. W/ 8d OR 10d NAILS. FINISH COVERING FOR SHEETED ROOF MAY BE COMPOSITION ROOFING OVER 30# FELT, OR 29 GAUGE METAL ROOFING OVER 15# FELT. BUILDING MAY BE SIDED WITH 7/16" O.S.B. BOARD, 1/2" C—DX PLYWOOD, 15/32" T-111 PLYWOOD SIDING OR HARDI—PLANK. LAP SIDING MAY BE INSTALLED OVER BUILDING WRAP AND WALL SHEETING. SHEETING SHALL BE FASTENED TO GIRTS WITH 8d, NAILS 0 6" 0. C., OR 1 1/2" LONG X 16 GA. STEEL STAPLES 0 6" 0. C. PANEL EDGES & INTERMEDIATE FRAMING. SOIL COMPACTION — ALL BACKFILLED SOIL BENEATH FOOTINGS SHALL BE COMPACTED WITH A VIBRATORY COMPACTOR TO 95% OF THE PROCTOR DENSITY AS DETERMINED BY ASTM A1557, METHOD D. TRUSSES SHALL BE DESIGNED BY AND BEAR THE SEAL OF AN ENGINEER REGISTERED TO PRACTICE IN THE STATE OF WASHINGTON. TRUSS LOADING: TOP CHORD LIVE LOAD = 50 PSF TOP CHORD DEAD LOAD = 5 PSF BOTTOM CHORD DEAD LOAD = 1 PSF WAMBEKE ENGINEERING Daniel Wanbeke, P. E. +e, vAst 99223 TO 509-443-6186 Foxe 309-448-6392 a-noR dwbeke6nn.con SPECIFICATIONS FOR TYPICAL POST FRAME BUILDINGS BULLDOG CONTRACTORS, INC. 11308 E. 11TH AVENUE SPOKAE VALLEY. WA 99206 16 DRAWN BY DATE WAMBEKE —29-10 APPROVED SCALE BULLDOG—IBC03 NTS REV. NOTES FOR FOOTING DETAIL TREATED POSTS AS SIZED PER SCHEDULE VIBRATE OR ROD CONCRETE TO OBTAIN FULL BEARING UNDISTURBED SOIL FOOTING DETAIL N.T.S. WAMBEKE ENGINEERING Daniel Varibeke, P. E. 3 E°'tv`rrte` TO 509-443-6186 RUC 509-448-6382 e-rwlANAbelcsertsrucon STANDARD FOOTING DETAILS STANDARD POST FRAME BUILDING PLANS BULLDOG CONTRACTORS, INC. 11308 E. 11TH AVENUE SPOKANE VALLEY. WA 99206 DRAWN BY DATE WAMBEKE 2-24-08 BULLDOG—IBC04 APPROVED SCALE NTS REV. POST/FOOTING SCHEDULE 30' SPANS, 50 PSF LIVE LOAD POST COLUMN FOOTING KNEE BRACE CONCRETE SPACING "H" W X D "B" DIA. "T" REQUIRED VOLUME, YD 10'-0" 8'-0" 6" X 6" 2'-6" 3'_0" ZZZZZZZZZ 000000000 0.55 0.55 10'-0" 12'-0" 6,. X 6" W/2" X 6" 2'-6" 3'-0" 0.55 10-0 � 14-0 ,. 6" 6" 6" X W/2 X 2-6 �� �� 3 0.55 10'-0" 16'-0" 6" X 8., 2'-6" 3'-0" 0.55 10'-0"18'-0" 6" X 8" W/2" X 6" 2'-6" 3'-0" 0.55 10-0�� _ 20-0 �� 6 X 10" 2'-6"3-0 ,� 0.55 10'-0"22'-0" 6" X 10" W/2" X 6" 2'-6" 3'-2" 0.58 10'-0"_. 24'-0" 6" X 12" 2'-6" 3'-3" 0.59 12'-0" 8'-0" 6" X 6" 2'-8" ` 3'-0" NO 0.62 12-0" 10'-0" 6" X 6.. 2'-8" 3'_0" NO 0.62 12-0" 12'-0" 6" X 6" W/2" X 6" 2'-8" 3'-0" NO 0.62 12-0" 14'-0" 6" X 8" 2'-8" 3'-0" NO 0.62 12-0" 16'-0" 6" X 8'W/2" X 6" 2'-8" 3'_0" NO 0.62 12-0" 18'-0" 6" X 10" 2'-8" 3'-0" NO 0.62 12-0" 20'-0" 6" X 10" W/2" X 6" 2'-8" 3'_0" NO 0.62 12-0" 22'-0"6 X 12" 2'-8" 3'-3" YES 0.68 12-0" 24%0" 16" X 12"2'-8" 3'-6" NO 0.73 NOTE: 1. THE NEXT LARGER SIZE POST MAY BE SUBSTITUTED FOR POSTS WITH 2" X 6" LAMINATIONS. 2. ENDWALL POSTS SHALL BE 6" X 6" ROUGH CUT HEM—FIR #2 TREATED POSTS UP TO 15'-0" WALL HEIGHT. ABOVE 15' WALL HEIGHT, ENDWALL POSTS SHALL BE 6" X 8" ROUGH CUT HEM—FIR #2 POSTS. 3. FOOTINGS FOR ENDWALL POSTS SHALL BE A MINIMUM OF 20"0 X 3'—O" DEEP FOR WALL HEIGHTS TO 16'-0". ABOVE 16' WALL HEIGHT, FOOTINGS SHALL BE 24"0 X 3'-4" DEEP. 4. ABOVE FOOTING DESIGNS ARE FOR POST FRAME BUILDINGS WITH CONCRETE FLOORS (CONSTRAINED POSTS). IF BUILDINGS WILL NOT CONCRETE FLOORS, INCREASE FOOTING DIAMETER X 2" & FOOTING DEPTH X 4". 1�LiirMipWAMBEKE ENGINEERING og R „'� spoor*, \Ast9iMt DnnleT, W5o9-44496 meq, �Fe 50E9-448-6592 e- "� POST & FOOTING SIZES . + 26' TO 32' SPANS — 50 PSF L.L STANDARD POST FRAME BUILDING PLANS BULLDOG CONTRACTORS, INC. 11308 E. 11TH AVENUE ssI�ieo NA SPOKANE��ALLEY. WA 99206 DRAWN REV. WAMBEKE 2-24-08 BULLDOG—IBC05-30 APPROVED SCALE NTS PURLIN CONNECTION METH❑IJS1 A). PURLINS MAY BE HUNG OFF THE TRUSS TOP CHORD FACES W/ STANDARD SIMPSON JOIST HANGERS OR EQUAL. B). PURLINS MAY BE BUTTED AND NAILED W/(2) 16d NAILS INTO EACH PURLIN. C). PURLINS MAY BE LAPPED ANDNAILED W/C3) 16dNAILS, ON CONNECTION METHODS 'B' AND 'C', TOENAIL BACK SIDE OF PURLIN W/(1) 16d NAIL INT❑ EACH TOP CHORD MEMBER l�• PURLIN C ,C11111111111111111111111111r ; `IN0ON CTi.- v PUR "1101) TYZerlo UR N 0 0 DETAIL 1 - TRUSS COLUMN CONNECTION, PURLIN SUPPORT N.T.S. NOTES FOR CONNECTION DETAIL S1 TRUSS TOP CHORDS TRUSS DESIGN BY TRUSS MANUFACTURER (S2 PURLIN SUPPORT STRUT 2° X '4' X FULL DEPTH OF TOP CHORD PLUS PURLIN. NAIL PURLINS W/(3) 16d NAILS S3 NAIL STRUT TO TOP CHORD 14/(3) 16d NAILS EACH SIDE. S4 MANUFACTURED TRUSS. NOTCH POSTS 1-1/2' EACH SIDE TO PROVIDE TRUSS SEAT. SS WOOD POST, SEE POST/FOOTING SCHEDULE. S6 4 - 40d GALV. NAILS IN PRE -DRILLED HOLES OR 3/4'0 MACHINE BOLT SOLID BLOCKING AT CONNECTION POINTS. TYP. PURLIN, SEE FLOOR PLAN FOR SIZE S9 2' X 6' OR 2' X 8' TOP GIRT 05 )4 - 16d NAILS OR 3/4'0 M. BOLT WAMBEKE ENGINEERING �q�� Daniel Wanbeke, P. E. War VA 99223 TO 309-443-6186 Fax 709-448-6382 e-ndl dranbekarvin.con TRUSS - COLUMN CONNECTION PURLIN CONNECTION METHODS STANDARD POST FRAME BUILDING PLANS BULLDOG CONTRACTORS, INC. 11308 E. 11TH AVENUE SPOKAE Vitt t FY_ WA 99906 12 DRAWN BY DATE WAMBEKE -24-08 APPROVED SCALE NTS BULLDOG -18C06 REV. TYPICAL SIDE ELEVATION N.T.S. WAMBEKE ENGINEERING 13 EA WA Danlet Wanbeke, P. E. 29 9 Tel, S09-443-6186 Fax, 509-448-6582 e-noR dvanbekelbisrtcon TYPICAL PLAIN SIDE ELEVATION STANDARD POST FRAME BUILDING PLANS BULLDOG CONTRACTORS, INC. 11308 E. 11TH AVENUE SPOKANE VALLEY. WA 99206 DRAWN BY DATE WAMBEKE r-24-08 APPROVED SCALE NTS BULLDOG—IBC08 REV. 440 12 r '/moi 14 1 1 1 1 1 1 1 1 1 20' 0' MAXIMUM SINGLE OVERHEAD DDDR OPTION FRONT ELEVATION N.T.S. NOTES FOR FRONT ELEVATI❑N Si HALF TRUSS DESIGN BY OTHERS SUPPORT PURLINS @ END TRUSS W/2' X 6' OR 2' X 8' STD J❑IST HANGERS, LOWER TRUSS FOR END OVERHANG, IF REQ'D 0 2' X 10' HEADER 0 2' X 6' GIRTS @ 24' ❑.C., 10' BAYS, DF -L #2 2' X 6' GIRTS @ 24' O,C., 12' BAYS, DF -L #2 0 2' X 8' FACIA BOARDS S5 TREATED WOOD POSTS, SIZED PER SCHEDULE 0 TREATED 2' X 6' BOTTOM GIRT OR TREATED 2' X 10' BOTTOM GIRT WAMBEKE ENGINEERING Daniel WaMbeke, P. E.v9 Te1i 509-443-6186 Fax' 509-448-6582 e-naA deanbekeensncon FRONT ELEVATION SINGLE OVERHEAD DOOR OPTION TYPICAL POST FRAME BUILDINGS BULLDOG CONTRACTORS, INC. 11308 E. 11TH AVENUE SPOKANE VALL;Y. WA 99206 DRAWN BY DATE WAMBEKE 2-24-08 APPROVED SCALE NTS BULLDOG -MOB REV. N-D❑OR 3068 MANDOOR ❑PTI❑N g OPENING LA OPTIONAL FRONT ELEVATION N.T.S. NOTES FOR OPTIONAL FRONT ELEVATIONS HALF TRUSS DESIGN BY OTHERS 2' X 6° HEADER 4' X 6' DOOR POST - 8' THRU 14' WALL HEIGHT W/ 28 X 6" FACER. 6' X 6' DOOR POST - 16° & 18' WALL HEIGHT W/ 2° X 8° FACER. 0 WAMBEKE ENGINEERING Daniel Warnbeke, P. E. 29 vn1st in t TO 509-443-6186 Fax, 509-448-6588 moll dwronbela8 FRONT ELEVATION PASS DOOR OPTION TYPICAL POST FRAME BUILDINGS BULLDOG CONTRACTORS, INC. 11308 E. 11TH AVENUE SPOKAE VALLEY. WA 99206 12 DRAWN BY DATE WAMBEKE —24-08 APPROVED SCALE NTS BULLDOG—IBC 12 ALTERNATE TRUSS WEB BRACING SYSTEM INTERIOR OR GABLE END TRUSSES Od NAILS @ 6' D.C. ' X6'OR2'X8' L -BRACE Od NAILS @ 6' O.C. ' X4' L -BRACE TRUSS WEB MEMBER TRUSS WEB MEMBER SECTION B -B SECTION B -B AT INTERIOR TRUSSES AT GABLE END TRUSS NOTE: TRUSS DIAGRAMS WILL OFTEN REQUIRE WEB MEMBER BRACING, WHICH IS SHOWN ON TRUSSDRAWINGS AS THE METHOD OF TRUSS WEB BRACING SHOWN ABOVE REPLACES 1' X 4' OR 2' X 4' WEBMEMBER BRACING. FOLLOW THESE INSTRUCTI❑NS FOR ALL WEB MEMBER BRACING TO REPLACE 'RAT -RUN' WEB WAMBEKE ENGINEERING � Daniel Wambeke, P. E. r.,.r3 ,eEe`tW 9 TW 509-443-6186 nun 309-448-6582 e-nWK dwaribekorlywn.con TRUSS WEB MEMBER BRACING ALTERNATIVE TYPICAL POST FRAME BUILDINGS BULLDOG CONTRACTORS, INC. 11308 E. 11TH AVENUE SPOKAE VALLEY. WA 99206 12 DRAWN BY DATE WAMBEKE -24-08 APPROVED SCALE NTS BULLDOG-IBC16 24' TO 48' _ `'� OVERHANG ,/- ,f - LOWER LOWER GABLE END TRUSS X PURLIN DEPTH PURLINS 24' TO 48' OVERHANG 2' X 4' BLOCK NAIL TO TRUSS & PURLINS WITH 3 - 10d NAILS SIMPSON HURRICANE STRAP ON ALTERNATE PURLINS ENDWALL POST PLAN VIEW GABLE END OVERHANG I ' X _' FASCIA BOARD 2' X ' BLOCKING AS REQUIRED GABLE END TRUSS SECTION @ OVERHANG WAMBEKE Fan ENGINEERING airEs,6"91a6 tDnie30W'arbe, P.50E9-4484482 mon GABLE END OVERHANG POST FRAME BUILDINGS bULLUUI7 LUN I KAL I UKJ, INC.. 11308 E. 11TH AVENUE SPOKANE VALLEY. WA 99206 DRAWN DT DATE WAMBEKE —24-08 APPROVED SCALE • . 1•-O, GABLE.OVERHANG NU 1 ES h Uhf GUNNEL [IUN DE FAIL S1 MANUFACTURED TRUSS TOP CHORDS TRUSS DESIGN BY TRUSS MANUFACTURER 0 PURLIN SUPPORT STRUT 2' X 'T' X FULL DEPTH OF TOP CHORD PLUS PURLIN. NAIL PURLINS W/(3) 16d NAILS 0 NAIL STRUT TO TOP CHORD W/(3) 16d NAILS EACH SIDE. 0 MANUFACTURED TRUSS NOTCH POSTS 1-1/2' EACH SIDE TO PROVIDE TRUSS SEAT. S5 WOOD POST, SEE POST/FOOTING SCHEDULE. S6 (4) 40d SPIKES IN PRE -DRILLED 3/16' DIA. PILOT HOLES, EACH SIDE SOLID BLOCKING AT CONNECTION POINTS. TYP. PURLIN, SEE FLOOR PLAN FOR SIZE 2' X 6' OR 2' X 8' EAVE GIRT 02' X 6' OR 2' X 8' OVERHANG PURLIN 2' X 6' OR 2' X 8' JACK RAFTERS NAIL TO TRUSS CHORDS WITH (2) 16D NAILS @ 6' O. C. AND TOENAIL TO FIRST PURLIN, 03) m m PURLIN CONNECTION METHODS= A), PURLINS ARE TO BE HUNG OFF THE TRUSS TOP CHORD FACES W/ STANDARD SIMPSON JOIST HANGERS OR EQUIVALENT. DETAIL 1 - TRUSS COLUMN CONNECTION, PURLIN SUPPORT & EAVE OVERHANG N.T.S. WAMBEKE ENGINEERING 2913 ! 61st Panlel Wambeke, P. E. Sbolmne. VA 99223 TsI 509-443-6186 Fsw 509-448-6382 s -rot etasnbtkellown.con EAVE OVERHANG FOR POST FRAME BUILDINGS 3ULL000 LUN I KAC I URS, INC. 11308 E. 11TH AVENUE SPOKAF VAI I Y. WA 99206 DRAWN BY DATE 24-0 APPROVED P WAMBEKE E =Au — nr�RovED a�E EAVE.OVERHANG /16' = 1'-0' rME- D 01/4- kl ADDRESS- 1 `{ 4),0 80 LEGAL.` PARCEL#- ySa�a e cc 3 Sc�