1990, 10-03 Permit App: 90005105 Furnace, Piping SPOKANE COUNTY DEPARTMENT OF BUILDINGS
W. 1303 BROADWAY AVENUE
SPOKAN•,WASHINGTON 99260
(509)456-3675
I certify that I have examined this permit/application,state tha e in • ation contained in it and submitted by me or my agent to compile said permit/application is true
and correct, and authorize Spokane County to procee. ith : o easing. In addition, I have read and understand the INSPECTION REQUIREMENTS/NOTICE
provisions included herein and agree to comply with - e provisi. s of laws nd ordinances governing this type of work will be complied with whether specified
herein or not.I understand that the issuance of thi .er applica•s any su equent inspection approvals or Certificates of Occupancy shall not be construed to
give authority to violate or cancel the provisio :.f.• state orloc. I. • .ting onstruction,or as a warranty of conformance with the provisions of any state or local
laws regulating construction.
SIGNATURE OF APPLICATION
OWNER OR AGENT +; DATE
\ \77"/ -
V19
051990 � �
'2'67'2'67 - c
IT r
PROJECT NUMBER= 909051 C • DATE= 10i03t90
"I
Y »r
« 01
ISSUED PERMIT
************•*********•******* PERMIT INFORMATION *********************•;:•******
SITE STREET= i •i 6 N SUNDERLAND RD PARCEL• 17543-1703
ADDRESS= SPOKANE WA 99206
PERMIT USE: GAS FURNACE & PIPING
PLAT 0= 001854 PLAT NAME= OPPORTUNITY PLAT 3
BLOCK= LOT= ZONE= TFR DIST4= F.
AREA= 0001 1000 i=/A::= F W I DJH= DEPTH= R/W-=
4 OF BL..DGE= m DWELLINGS= 1
CAA �ic.(�.�� t
OWNER= SNARSK I , r t r 22 5
NEIL I I_. �"'F1 t.J N f::.__ .7 t?i >f�.,a.. .,•..4..>O
STREET= 116 N SUNDERLAND RD �;.
ADDRESS= SPOKANE WA 99206
CONTACT NAME= STURM HEATING• c:/ ' /. ' PHONE NUMBER= 509 :325 4505
BUILDING SETBACKS : FRONT= NA LEFT= NA RIGHT= NA REAR= NA
iN************** ********#i•***** MECHANICAL_ PERMIT '*' :*****3'********•**•**•**•****
CONTRACTOR= STIJRM HEATING PHONE= 509 325 4505
STREET= 204 r INDIANA AVE
ADDRESS= SPOKANE WA 99207
• ITEM DESCRIPTION QUANTITY FEE AMOUNT
-------------------------
PROCESSING FEE Y 25.00
CTAS HT1:r fl IJIPc 100, 000>BTI.J 1 12.00
GAS PIPING i 1 .00
•
.if•lk****************•yl** -****** •* PAYMENT SUMMARY ***u*****•* • •h* •************ •
PAYMENT DATE RECEIPT RECEIPT0 PAYMENT AMOUNT
10/03/90 6104 38. 00
_.3
-. "_ __..
TOTAL DUE= .00 TOTAL.. PAID= 38.00
PERMIT TYPE FEE AMOUNT AMOUNT PAID AMOUNT OWING
MECHANICAL PRMT 30.00 38.00 .00
38.00 38.00 .00
PROCESSED BY : WENDEL, GLORIA
PRINTED BY : WENDEL.., GLORIA
*•** ••x******* ****x*****•*** ***** THANK YOU ******•*******•*******•x************
NOTICE
It is the responsibility of the permittee, not Spokane County, to see to it that the use described on the front of this permit
complies with applicable codes and requirements and that required inspections are requested. Failure to request required
inspections and obtain the necessary approvals prior to progressing beyond the point where inspections are required may
necessitate removal of certain parts of the construction at the owner's/permittee's expense. At a minimum, the following
inspections ARE REQUIRED by County Code:
1. FOOTING—when forms and reinforcement are in place and prior to placement of concrete.
NOTE:This inspection includes review of the structure's setbacks from property lines.Minimum setbacks are
established by County zoning regulations.Typically,side and rear yard setbacks are measured from property
lines, while setbacks for yards abutting streets are measured from the property line or the center line of the
roadway right-of-way,whichever provides the greater setback from the center line of the roadway right-of-way.
Curb lines and fence lines are not necessarily indicative of property lines.In some residential areas,the County
can own as much as 20 feet of right-of-way between your property and the actual improved street/curb. The
responsibility to comply with applicable setback provisions lies solely with the permittee—neither Spokane
County nor its authorized representatives assume any responsibility for the verification or location of your
property lines.Please verify their location prior to locating your structure.Failure to properly locate the structure
may require its relocation at the owner's/permittee's expense.
2. FOUNDATION—when forms and reinforcement are in place and prior to placement of concrete.(Blocking for a
manufactured home is required to be inspected prior to the installation of skirting.)
3. FRAMING —after all framing, bracing and blocking is in place,and prior to concealing.
4. INSULATION— prior to the installation of drywall.
5. PLUMBING —after rough-in, before covering, and final.
6. MECHANICAL—rough-in of piping, before covering, metal chimneys before concealment,and final.
7. FINAL—when complete and prior to occupancy and/or use. Please provide 24 hours notice.
NOTE:In addition to inspection of the structure,this inspection includes review of site improvements(typically
depicted on the approved site plan)required by ordinance or as a condition of approval of this permit.Items such
as the installation of fire hydrants,fire department access,on-site drainage("208 swales"),road improvements,
parking,and landscaping are common requirements of a permit/site plan which must be completed prior to final
approval of a building or issurance of a Certificate of Occupancy.
In addition to the above any plumbing or mechanical systems or materials which would be concealed by framing, drywall,
concrete, etc., must be inspected prior to cover. Check with the department for "special inspections" in conjunction with
commercial projects.
CALL 456-3675 FOR INSPECTIONS.
TO INSURE PROMPT SERVICE, PLEASE GIVE 24 HOUR NOTICE.
YOUR INSPECTOR IS
UNDER CERTAIN CIRCUMSTANCES, PARTS OF YOUR PROJECT MAY REQUIRE INSPECTIONS FROM OTHER
AGENCIES:
• road cuts for utilities or drives,State or County Engineer's Office
456-3600
• on-site waste disposal system, Environmental Health District
456-6040
• construction in a flood plain, County Engineer's Office
456-3600
• electrical wiring, State Department of Labor and Industries
456-2792
• sewer connection, County or City Utilities Department
456-3604
EXPIRATION
Unless otherwise noted, this permit will be considered null and void by limitation of the work authorized by the permit is not
commenced or is stopped for a period of 180 days, unless a written request for an extension of the permit is received and
approved by the Building Official prior to expiration.Ata minimum an inspection should be requested at least once every 180
days to assure the validity of the permit.A permit may be renewed within one year of the date of expiration for one-half the
original fee, subject to certain limitations—please call us if you have any questions.
MISTAKES?
If you think we've made an error in processing this permit or in conducting inspections pertaining to it, or find erroneous
information in the permit,please bring it to our attention immediately by filing a written request for correction within 10 working
days of discovery.All such requests should be directed to the Department of Buildings at the address found on the face of this
permit.
MECHANICAL PERMIT APPLICATION FORM
Infbzution Worksheet
JOB STREET ADDRESS: 116 N. Sunderland /e)-5/(1.5
CITY/STATE/ZIP: Spokane, Wa. 99206 PARCEL NUMBER:
OWNER: Neil Snarsky PHONE NUMBER: 922-2458
MAILING ADDRESS: SAME
(Street) (City/State) (Zip)
CONTRACTOR: Sturm Heating. Inca LICENSE NUMBER:STURMI*210 QF
PHONE NUMBER: 325-4505
MAILING ADDRESS: E. 204 Indiana Spokane, Wa. 99207
(Street) (City/State) (Zip)
MECHANICAL WORKSHEET/FEE SCHEDULE
NUMBER X EACH
DESCRIPTION OF UNITS UNIT = AMOUNT
DUCTWORK SYSTEM x$10. 00 =
WOODSTOVE/INSERT x 25. 00 =
GAS WATER HEATER x 10. 00 =
HEATING EQUIPMENT <100, 000 BTU 1 x 12. 00 = 12 .00
HEATING EQUIPMENT +100,000 BTU x 15. 00 =
GAS PIPING (1 - 4 OUTLETS) 1 x 1 , 00, = 1 .00
GAS PIPING (5 OR MORE. EACH: ) x 1. 00 =
REFRIG 1-100M BTU (NOT A/C OR HEAT PUMP) x 12 . 00 =
REFRIG 101-500M BTU x 20. 00 =
REFRIG 501-1, 000M BTU x 25. 00 =
REFRIG 1,001-1,750M BTU x 35. 00 =
REFRIG +1,750M BTU x 60. 00 =
HEAT PUMP & AIR CONDITIONER 0-3 TONS _ _ x 12 . 00 =
HEAT PUMP & AIR CONDITIONER 3-15 TONS _ x 20. 00 = _
HEAT PUMP & AIR CONDITIONER 15-30 TONS _ x 25. 00 =
HEAT PUMP & AIR CONDITIONER 30-50 TONS _ x 35. 00 =
HEAT PUMP & AIR CONDITIONER +50 TONS _ - x 60. 00 =
VENTILATING FANS x 10. 00 =
EVAPORATIVE COOLERS _ _ x 10. 00 =
TYPE I HOOD (PER 12 ' OR 12 ' PTN. OF HOOD) x 50. 00 =
TYPE II HOOD x 10. 00 =
CLOTHES DRYER_ _ _ x 10. 00 =
RANGE x 10. 00 = _
GAS LOG •
x 10. 00 =
MISCELLANEOUS (NOT COVERED ELSEWHERE)_ _ x 10. 00 =
UNLISTED GAS APPLIANCE <400, 000 BTU _ _ x 50. 00 =
UNLISTED GAS APPLIANCE >400, 000 BTU_ _ _ x100. 00 =
USED APPLIANCE <400, 000 BTU x 50. 00 =
USED APPLIANCE >400, 000 BTU x100. 00 =
AIR HANDLER <10, 000 CFM x 12 . 00 =
AIR HANDLER >10, 000 CFM x 15. 00 =
SUBTOTAL $ 13 . 00
PLUS : PROCESSING FEE + $ 25 . 00
EQUALS: TOTAL PERMIT
NOTE: M N'IMUM PERMIT FEE IS $35. 00 FEE DUE _ $ 38 . 00
SIGNATURE /�, r ; 1 'A'
}
Spokane County Department of Building and Safety
West 1303 Broadway Avenue Spokane, WA 99260 (509) 456-3675
It1:
i-;il r 1� 1 7._Wei I_.
S P O K A N E �z R•, , I.U- C O U N T Y
DEPARTMENT OF BUILDINGS • A DIVISION OF THE PUBLIC WORKS DEPARTMENT
JAMES L. MANSON,C.B.O.,DIRECTOR DENNIS M.SCOTT.P.E.,DIRECTOR
October 17, 1991
Sturm Heating
204 East Indiana Avenue
Spokane, WA 99207
Gentlemen:
We recently received your request for a refund on Permit 90-005105
for a gas furnace and piping at North Sunderland Road. This permit
was issued on October 3 , 1990.
According to Section 304 (f) of the 1991 Uniform Building Code:
"The building official shall not authorize refunding of any fee paid
except on written application filed by the original permittee not
later than 180 days after the date of fee payment. "
Accordingly, we are unable to accomodate your request for a refund.
Sincerely yours,
Margaret J. Wands
Accounting Technician 3
CODE ENFORCEMENT DIVISION
WEST 1303 BROADWAY•SPOKANE,WASHINGTON 99260-0550•(509)456-3675
FAX(509)456-4703