2015, 05-14 Permit: BLD-2015-0120 Residential Energy Compliance Cert. Property Address: 1001 N Marcus
Conditioned Floor Area: 1907 Date: 05/ 14 / 2015
Builder or registered design professional:
Viking Builders Home Energy Audit Tech
Signature: AleQBtown 509 280 0381
R-Values
alues
Ceiling: Vaulted R- Floors: Over unconditioned space R-
Attic R- 49 Slab on grade floor R- 10
v Walls: Above grade R- 21 Doors: Metal R- 6.25
Below,int. R- Glazed R- 3.3
•
Below,ext. R- R-
1
C
V U-Factors and SHGC
NFRC rating(or) Windows U- .30 SHGC- N/A
I.! Default rating(Appendix A wsrc 2012) Skylights U- SHGC- N/A
Table 406.2 Option(s) 5B Total 406.2 Credits 1.5
Heating,Cooling&Domestic Hot Water
System Type Efficiency
Heating Gas forced air 95%
Cooling Electric central
DHW Electric heat pump 50 gal 2.4 EF
Duct&Building Air Leakage
All ducts&HVAC in conditioned space ( /no) Insulation R- 8
Air handler present (yes/)Ot)
Test Target 77 CFM@25Pa Test Result 40 CFM@25Pa
Building air leakage target:ACHc„<5.0-Tested leakage: ACIIs„= 3, 1
Onsite Renewable Energy Electric Power System
System type: Rated annual generation Kwh