2015, 05-14 Permit: BLD-2015-0120 Residential Energy Compliance Cert. Property Address: 1001 N Marcus Conditioned Floor Area: 1907 Date: 05/ 14 / 2015 Builder or registered design professional: Viking Builders Home Energy Audit Tech Signature: AleQBtown 509 280 0381 R-Values alues Ceiling: Vaulted R- Floors: Over unconditioned space R- Attic R- 49 Slab on grade floor R- 10 v Walls: Above grade R- 21 Doors: Metal R- 6.25 Below,int. R- Glazed R- 3.3 • Below,ext. R- R- 1 C V U-Factors and SHGC NFRC rating(or) Windows U- .30 SHGC- N/A I.! Default rating(Appendix A wsrc 2012) Skylights U- SHGC- N/A Table 406.2 Option(s) 5B Total 406.2 Credits 1.5 Heating,Cooling&Domestic Hot Water System Type Efficiency Heating Gas forced air 95% Cooling Electric central DHW Electric heat pump 50 gal 2.4 EF Duct&Building Air Leakage All ducts&HVAC in conditioned space ( /no) Insulation R- 8 Air handler present (yes/)Ot) Test Target 77 CFM@25Pa Test Result 40 CFM@25Pa Building air leakage target:ACHc„<5.0-Tested leakage: ACIIs„= 3, 1 Onsite Renewable Energy Electric Power System System type: Rated annual generation Kwh