Loading...
2006, 03-23 Permit App: 06000993 GarageProject Number: 06000993 Inv: 1 Application THIS IS NOT A PERMIT Penalties will be assessed for commencing work without a permit Date: 03/23/2006 Page 1 of 2 Project Information: Permit Use: 30 X 40 DETACHED GARAGE Setbacks: Front Left: Right: Rear: Site Information: Plat Key: 000000 Name: unknown Contact: EXCALIBUR STEEL STRUCTURES INC Address: PO BOX 14991 C - S - Z: SPOKANE, WA 99214-0991 Phone: (509) 921-1300 Group Name: Project Name: District: F Parcel Number: 45281.1902 Block: SiteAddress: 11619 E SUNVIEW CIR Location:: CSV Zoning: B-1 Water District: Neighborhood Business Area: 1,805.00 Acres Width: 0 Nbr of Bldgs: 0 Nbr of Dwellings: 0 Review Information: Lot: Owner: Name: MALMBORG, KENTON A & CAR Address: 11619 E SUNVIEW CIR SPOKANE VALLEY, WA 99206-70 Hold: ❑ Depth: 0 Right Of Way (ft): 0 Review Building Plan Review Released By: Landuse/Zoning/HE Conditions Released By: Sewer Review Permits: Originally Released: 03/23/2006 By: cjjanssen Released By: Originally Released: 03/23/2006 By: cjjanssen Operator: CJJ Printed By: CJJ Print Date: 03/23/2006 Project Number: 06000993 Inv: 1 Application THIS IS NOT A PERMIT Penalties will be assessed for commencing work without a permit Date: 03/23/2006 Page 2 of 2 Building Permit Contractor: EXCALIBUR STEEL Firm: EXCALIBUR STEEL STRUCTURE Address: PO BOX 14991 Phone: (509) 921-1300 SPOKANE, WA 99214-0991 This Application: Total Project: Description Grp Type Notes Sq Ft Valuation Sq Ft Valuation GARAGE U-1 VB 1,200 $22,800.00 1,200 $22,800.00 Item Description RESIDENTIAL PERMIT FEE ACCESSORY PLANS REVIEW WSBC SURCHARGE Notes: Payment Summary Permit Type Building Permit Totals: 1,200 $22,800.00 1,200 $22,800.00 Units Unit Desc 1 SELECT 1 SELECT 1 SELECT Permit Total Fees: Fee Amount $363.25 $90.81 $4.50 $458.56 Fee Amount Invoice Amount Amount Paid Amount Owing $458.56 $458.56 $0.00 $458.56 $458.56 $458.56 $0.00 $458.56 Disclaimer: Submittal of this application certifies the owner (or person(s) authorized by the owner) has both examined and finds the information contained within to be true and correct, and agrees that all provisions of laws and/or regulations governing this type of work will be complied with. Subsequent issuance of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the code or of any other state or local laws or ordinances. Signature: Operator: CJJ Printed By: CJJ Print Date: 03/23/2006 S!�1ne VaiIey r /) BUILDING PERMIT APPLICATION WORKSHEET City ofiSjpokan! (alley Community Development Department Building Division 11707 E. Sprague Avenue, Suite 106 Spokane Valley, WA 99206 one: (509) 688-0036; Fax: (509) 688-0037 1 REQUIRED SITE INFORMATION Street Address: f 1((4,1 ��►�� ��� ���'� Assessor's Tax Parcel Number(s): Legal Description: PERMIT DESCRIPTION: -10 (C�`�= I -, t / ' (3E g Building Permit ❑ Change in Use ❑ Grading ❑ Manufactured Home ❑ Relocation ❑ Tenant Improvement ❑ Fire Safety ❑ Other OWNER/APPLICANT INFORMATION ❑ Owner: .K.,,a- AcJi,,,boyl ❑ Applicant: Phone: c61 —7os6 Fax: Phone: Fax: Address: i I G t ? E , 5,._ -Kos ek.,, C-#-. Address: D 06-6-tiz.o4, ty k.� COwA State Zip Code City State Zip Code Contractor: Face,':6.4.S4ez( 1/4.5, -.1,,,,i -,,ref .<... 0 Architect: Phone: X12.1-1300 Fax: ciz 1 -4.7 Le Phone: Fax: Address: P o . ea.,( Address: C State Zip Code City WA State Contractor License #: XCi4 LSS cXOQB Contact: State Zip Code Spokane Valley Bus. Liscense #: Contact: HEIGHT TO PEAK: , 1MAIN DIMENSIONS: # OF STORIES: FLOOR TO SQ. FTG: 2"" FLOOR SQ. FTG: UNFIN BASEMENT SQ. FTG: FINISHED BASEMENT SQ. FTG: GARAGE SQ. FTG: ( ZOO DECK/COV. PATIO SQ. FTG: OCCUPANCY GROUP: .Dc S4c) r c� e_ CONSTRUCTION TYPE: .• Pa s+r w� HEAT SOURCE: # OF BEDROOMS: TOTAL HABITABLE SPACE: IMPERVIOUS SURFACE AREA: COST OF PROJECT: 30% SLOPES ON PROPERTY: SEWER OR ON-SITE SEPTIC SYSTEM? MANUFACTURED HOME Width: Manufacturer: Length: Year: Pit Set: RELOCATION Previous Address: Proposed Use: FIRE SAFETY Fire Sprinkler: Tent: # of Heads: Fire Alarm: Paint Booth: Fireworks Display: Blasting: Date/Time: Valuation: Above/Underground Storage Tank Size: WASHINGTON STATE NON-RESIDENTIAL ENERGY CODE Plans Examiner: Address: Phone: Fax: City State Inspector: Phone: Fax: Address: Zip City State Zip SPECIAL INSPECTIONS ❑ BOLTING ❑ CONCRETE Firm Name: ❑ REINFORCEMENT Phone: Inspector(s): Fax: ❑ WELDING DISCLAIMER The permitee verifies, acknowledges and agrees by their signature that: 1) If this permit is for construction of or on a dwelling, the dwelling is/will be served by potable water. 2) Ownership of this City of Spokane Valley Permit inure to the property owner. 3) The signatory is the property owner or has permission to represent the property owner in this transaction. 4) All construction is to be done in full compliance with the City of Spokane Valley Development Code. Referenced codes are available for review at the City of Spokane Valley Permit Center. 5) This City of Spokane Valley Permit is not a permit or approval for any violation of federal, state or local laws, codes or ordinances. Ownership of resulting development rights granted by any issued permit'. e to the prop y owner. Print Name cu^ -1 L '- ,& Signature _`� , / �i<< _ I Method of Payment: (Faxed permit applications will only be accepted with major bankcard) ❑ Cash ❑ Check ❑ Mastercard Bankcard #: Authorized Signature: El VISA Expires: VIN#: ❑ Other 12 43 1oZ PLANNING DEPT. APPROVED BY.C,ti DATE l'2 LtC 11 33 S � I •43 Cou R. C 21 m PURLIN CONNECTION METHODS! A). PURLINS MAY BE HUNG . NOTES FOR FLOOR PLAN OFF THE TRUSS TOP CHORD ®i INTERIOR FRAME WOOD POSTS, SEE FACES W/ STD, POST SCHEDULE THIS SHEET SIMPSON JOIST HANGERS GABLE WALL POSTS - 6' X 6' TYPICAL OR EQUAL, DOOR POSTS - 4' X 6' TYPICAL B), PURLINS MAY BE FOOTING DIMENSIONS, B + i' 8'1 D = 3' 0' BUTTED AND NAILED MAXIMUM POST SPACING 12' 0' W/(2) NAILS INTO EACH PURLIN, Q PURLINS @ 24' O.C., BEARING OR C). PURLINS MAY BE JOIST HANGERS (TYPICAL) LAPPED ANDNAILED - W/(3) 16dNAILS, SZ c'" _ w SPANS 12' TO 60' Nq j�jNG ON CONNECTION METHODS 0 w 'B' AND 'C', TOENAIL J ti BACK SIDE OF PURLINS8 a - DOUBLE TRUSSES W/0) 16d NAIL INTO 10 y 0 EACH TOP CHORD MEMBER Z J 00 a.J a Li m> X -I a w no v V) U Z J )- tr �- O 1 OL " C1 mo X11 tU tU 12 41 Rl I,I P P m SINGLE TRUSS PLAN VIEW N.T.S. Z Y --- TRUSS DESIGN BY TRUSS MANUFACTURER ZD) NOTES FOR SECTION A -A PURLIN SUPPORT STRUT 2' X 6' X FULL C3 Sl TYPICAL SEE FLOOR DEPTH OF TOP CHORD PLUS PURLIN, SPACING PLAN FOR SRZIEN, NAIL PURLINS W/(3) 16d NAILS 1� LiS2 TRUSS DESIGN BY OTHERS 0 Z D Q3 2' X 6' @ 24' O.C., 10' BAYS H F -W 2'X6'@ 24'0,C., 12' = p = DF -L #2 GIRTS FLAT @ 24 O.C, CLw C3 U S4 CONCRETE FOOTING, SEE SCHEDULE °•w N SS EXTEND POST TO TOP OF PURLIN POST, SEE POST/FOOTING SCHEDULE, 1120 ROOF FASTENED TO PURLINS WITH 4 - 10d NAILS ti 1 1/2' LONG WOODFAST TEKS. SOLID BLOCKING AT CONNECTION POINTS, WALL? FASTENED TO SB TYP, PURLIN, SEE FLOOR PLAN FOR SIZE ---- _a2A - S9 2' X 6' OR 2' X 8' EAVE GIRT IRTSSWITH V LONG l0 kD 21'• oJ NO I 11 o 6-0" X J o I CHORD NO 1 - 3/4' 0 MACHINE BOLT THRU KNEE BRACE X I BLOCK (U 0 24' & 3 N 0 36' & 4 6• x 6" W/Z' X 6" ---------- 6' X 8"W12'X 6" WX WW&ii 6" -_ 17 S X ' Wtt X 6' x rmiz-, x 6! 5 - 3/4' 0 M, BOLT @ BOLTING BLOCK - 50' NO -- NO 6 - 3/4' 0 M. BOLT @ BOLTING BLOCK - 60' w O- _2c 26 W O' r11 0 POSTIFOOTING 0 CD LIVE LOAD POST I COLUMN FOOTING KNEE BRACE I CONCRETE SPACING "H" a ' '11"DIA. "T" a VOLUME Y 10:6• -10'-0" S-0" 0 X 61 ex it Z 3'-0" 3'-0"- NO -140=-1141 Z 0 --- _10'-0"_12'-U' _•10'-0' ----- 14:0" r ------- 26_ -26' 3-0•' 3-0" _NO --a11441 NO -- - - -mi _vr-- 110141" 16-0 8" x 0" 26 3'•A•' NO _WF- -;We-6•XD"w1TX6" 26 3'-0 NO ~ 10:6' _10'-6' 10:0" m ~ 2F- _26 26' 3'.0•• 3'-2 _ Y -T' -_NO _NO_ NO _0.41 _1144_ 0.45 120" 9-0" 6' X 8" OLI 3-0" Q- I 6_ "a C.1 7-0" ,D L, o _12-0" _14:0' 16.0' 18'•0' _ 2D'-0' 22'-6' p Q I -3•-0- 9'-0" - -- 3••0•' 3•-0" 3'4'-' 3'-2 p o, '. _0.47 1147 - - 1147 _1147 115 x 24'•Cr &' x 12' - x l NO NO 0.56 POSTIFOOTING SCHEDULE 36 SPANS cu LIVE LOAD R' COLUMN FOOTING (U IKNEEBRACE W SPACING "H" W -0-DIA. "T' 0(, VOLUME YD 10:6' -.__..--__.__ 10: D" 0(V 6' X 6" .--._ e" x 6- 2E' 3-0" NO 1147 -__---.__.-._.-- z6' 3• u" Z J 00 a.J a Li m> X -I a w no v V) U Z J )- tr �- O 1 OL " C1 mo X11 tU tU 12 41 Rl I,I P P m SINGLE TRUSS PLAN VIEW N.T.S. BUILDING SECTION A -A N.T.S. SINGLE OVERHEAD DOOR OPTION FRONT ELEVATION NOTES FOR FRONT ELEVATION N.T.S. Sg HALF TRUSS DESIGN BY OTHERS SUPPORT PURLINS @ END TRUSS W/2' X 6' S6 TREATED 2' X 6' BOTTOM GIRT S2 2' X 10' HEADER S3 2' X 6' GIRTS @ 24' D.C., 10' BAYS, DF -L #2 2' X 6' GIRTS @ 24' O.C., 12' BAYS, DF -L #2 S4 2' X 8' FACIA BOARDS SS TREATED WOOD POSTS, SIZED PER SCHEDULE 9TREATED 2' X 6' BOTTOM GIRT OR TREATED 2' X 10' BOTTOM GIRT S2 IB S4 I -� S1 DETAIL 1 - TRUSS COLUMN CONNECTION, PURLIN SUPPORT N.T.S. NOTES FOR FOOTING DETAIL IS1 TREATED POSTS AS SIZED PER SCHEDULE 2 VIBRATE OR ROD CONCRETE TO OBTAIN FULL BEARING @3 UNDISTURBED SOIL T Z Y --- TRUSS DESIGN BY TRUSS MANUFACTURER ZD) NOTES FOR SECTION A -A PURLIN SUPPORT STRUT 2' X 6' X FULL C3 Sl TYPICAL SEE FLOOR DEPTH OF TOP CHORD PLUS PURLIN, SPACING PLAN FOR SRZIEN, NAIL PURLINS W/(3) 16d NAILS 1� LiS2 TRUSS DESIGN BY OTHERS r Z D Q3 2' X 6' @ 24' O.C., 10' BAYS H F -W 2'X6'@ 24'0,C., 12' = p = DF -L #2 GIRTS FLAT @ 24 O.C, SIDE OF POST WITH 4 - 16d NAILS C3 U S4 CONCRETE FOOTING, SEE SCHEDULE ON TOP NAILING BLOCK N SS EXTEND POST TO TOP OF PURLIN POST, SEE POST/FOOTING SCHEDULE, 1120 ROOF FASTENED TO PURLINS WITH 4 - 10d NAILS ti 1 1/2' LONG WOODFAST TEKS. SOLID BLOCKING AT CONNECTION POINTS, WALL? FASTENED TO SB TYP, PURLIN, SEE FLOOR PLAN FOR SIZE ---- _a2A - S9 2' X 6' OR 2' X 8' EAVE GIRT IRTSSWITH V LONG l0 KNEE BRACE, IF REQ'D. SEE POST SCHEDULE 21'• WOODFAST TEKS. NO I 11 2- X 6- X 24' OR 2' X 8' X 24' BLOCK 6-0" BUILDING SECTION A -A N.T.S. SINGLE OVERHEAD DOOR OPTION FRONT ELEVATION NOTES FOR FRONT ELEVATION N.T.S. Sg HALF TRUSS DESIGN BY OTHERS SUPPORT PURLINS @ END TRUSS W/2' X 6' S6 TREATED 2' X 6' BOTTOM GIRT S2 2' X 10' HEADER S3 2' X 6' GIRTS @ 24' D.C., 10' BAYS, DF -L #2 2' X 6' GIRTS @ 24' O.C., 12' BAYS, DF -L #2 S4 2' X 8' FACIA BOARDS SS TREATED WOOD POSTS, SIZED PER SCHEDULE 9TREATED 2' X 6' BOTTOM GIRT OR TREATED 2' X 10' BOTTOM GIRT S2 IB S4 I -� S1 DETAIL 1 - TRUSS COLUMN CONNECTION, PURLIN SUPPORT N.T.S. NOTES FOR FOOTING DETAIL IS1 TREATED POSTS AS SIZED PER SCHEDULE 2 VIBRATE OR ROD CONCRETE TO OBTAIN FULL BEARING @3 UNDISTURBED SOIL T MANUFACTURED TRUSS TOP CHORDS 24' SPANS 30 & 40 PSF LIVE LOAD TRUSS DESIGN BY TRUSS MANUFACTURER COLUMN (SD PURLIN SUPPORT STRUT 2' X 6' X FULL KNEE BRACE DEPTH OF TOP CHORD PLUS PURLIN, SPACING • NAIL PURLINS W/(3) 16d NAILS B••DIA. (Q)NAIL r VOLUME Y • H B' x 6" 6" x &' (2)MANUFACTURED TRUSS - NAIL TO EACH - NO0.20 NO- - _ 0.20 SIDE OF POST WITH 4 - 16d NAILS _70'-0 10'-0" 12:0" FOOTING DETAIL N.T.S. TREATED POST NOTES FOR TRUSS BOTTOM CHORD BRACING N.T.S. S1 GABLE END TRUSS S2 DOUBLE INTERIOR TRUSSES S3 GABLE END POST S4 2' X 4' BOTTOM CHORD BRACING @ 10' 0' O.C. SS 2' X 3' BLOCK WITH 4 - 10d NAILS TO BOTTOM CHORD BRACE 4 - 16d GALV. NAILS EACH GIRT (FLAT) LV TYPICAL GIRT CONNECTION .. r 2'X6'X18' BOLTING BLOC' .. i a .. 0 0 0 0 .. ►I m 2'X 6'X18' BOLTING .BLOCK DETAIL 3 - 16d NAI (SD MANUFACTURED TRUSS TOP CHORDS 24' SPANS 30 & 40 PSF LIVE LOAD TRUSS DESIGN BY TRUSS MANUFACTURER COLUMN (SD PURLIN SUPPORT STRUT 2' X 6' X FULL KNEE BRACE DEPTH OF TOP CHORD PLUS PURLIN, SPACING "H" I NAIL PURLINS W/(3) 16d NAILS B••DIA. (Q)NAIL STRUT TO TOP CHORD W/(3) 16d VOLUME Y _10'-0" NAILS EACH SIDE. B' x 6" 6" x &' (2)MANUFACTURED TRUSS - NAIL TO EACH - NO0.20 NO- - _ 0.20 SIDE OF POST WITH 4 - 16d NAILS _70'-0 10'-0" 12:0" ON TOP NAILING BLOCK 1B" (5)WOOD POST, SEE POST/FOOTING SCHEDULE, 1120 0 4 - 10d NAILS 10:P tb� a' S7 SOLID BLOCKING AT CONNECTION POINTS, - _26 SB TYP, PURLIN, SEE FLOOR PLAN FOR SIZE ---- _a2A - S9 2' X 6' OR 2' X 8' EAVE GIRT 10:6• l0 KNEE BRACE, IF REQ'D. SEE POST SCHEDULE 21'• AND DETAIL 2 NO I 11 2- X 6- X 24' OR 2' X 8' X 24' BLOCK 6-0" 1® i - 3/4' 0 MACHINE BOLT THRU TRUSS T. CHORD NO 1 - 3/4' 0 MACHINE BOLT THRU KNEE BRACE 120- 1 - 3/4' 0 MACHINE BOLT THRU BOLTING BLOCK 26_ 3 - 3/4' 0 M. BOLT @ BOLTING BLOCK - 24' & 3 _0.41 4 - 3/4' 0 M, BOLT @ BOLTING BLOCK - 36' & 4 6• x 6" W/Z' X 6" ---------- 6' X 8"W12'X 6" WX WW&ii 6" -_ 17 S X ' Wtt X 6' x rmiz-, x 6! 5 - 3/4' 0 M, BOLT @ BOLTING BLOCK - 50' NO -- NO 6 - 3/4' 0 M. BOLT @ BOLTING BLOCK - 60' (04 - 16d NAILS _2c 26 DOUBLE OVERHEAD DOOR OPTION OPTIONAL FRONT ELEVATION N.T.S. SINGLE SLIDING DOOR OPTION OPTIONAL FRONT ELEVATION N.T.S. OPTIONAL FRONT ELEVATION N.T.S. - 16d NAILS TYP, GABLE END TRUSS CONNECTION USE BOLTING BLOCKS BELOW ALL CORNER COLUMN GIRTS SPLIT SLIDER DOOR OPTION OPTIONAL FRONT ELEVATION N.T.S. NOTES FOR OPTIONAL FRONT ELEVATIONS S1 HALF TRUSS DESIGN BY OTHERS S2 2' X 10' HEADER UP TO 12'-0' DOORS 2' X 12' HEADER UP TO 20'-0' DOORS 2' X 12' BACKED WITH 2' X 6' UP TO 24'-0' S3 2' X 6' HEADER S4 4' X 6' DOOR POST - 8' THRU 14' WALL HEIGHT W/ 2' X 6' FACER. 6' X 6' DOOR POST - 16' & 18' WALL HEIGHT W/ 2' X 8' FACER. SS DOUBLE 2' X 6' KINGPOST DETAIL 2 - KNEE BRACE N.T.S. NOTES FOR DETAIL 2- 1KNEEBRACE S1 TRUSS TOP CHORD DESIGN BY OTHERS S2 TRUSS BOTTOM CHIRD, DESIGN BY OTHERS S3 2' X 6' KNEE BRt�CE SWOOD POST, SEE OST/FOOTING SCHEDULE S5 3/4' DIA. BOLT 9 2' X 6. OR 2' X ' TRUSS SEAT EACH SIDE OF POST @ EACH <NEE BRACE CONNECTION 0 NAIL KNEE BRACE TO POST WITH 4 - 16d NAILS 5NAIL BOLTING BL CK TO POST BRACE WITH 8 - L6cI NAILS 0 4 - 10d NAILS NOTES, KNEE BRACE REQUIREI WHERE SHOWN ON POST/FOOT NG SCHEDULE, BRACE NOT REQUIRED AT GABLE END TRUSSES, TYPICAL SIDE ELEVATION ^� N.T.S. TRUSS WEB BRACING )2' X 8' H ADER )2' X 11 EADER FOR 10' & 12' SLIDING D ORS 2' X 8' H ADER FOR 8' & SMALLER SLIDING D ORS NOTES FOR TRUSS WEB BRACING: TRUSS DIAGRAMS WILL OFTEN REQUIRE WEB MEMBER BRACING, WHICH IS SHOWN ON TRUSS DRAWINGS S THE METHOD OF TRUSS WEB BRACING SHOWN ABOVE REPLACES V X 4' OR 2' X 4' WEB MEMBER BR CING. FOLLOW THESE INSTRUCTIONS FOR ALL WEB MEMBER BRACING TO REPLACE 'RAT -RUN' WEB 10d NAILS @ 6' D.C. Od NAILS @ 6' O.C. 'X6'OR2'X8' 1X4' L -BRACE L -BRACE TRUSS WEB MEMBER TRUSS WEB MEMBER SECTION B -B SECTION B -B AT INTERIOR TRUSSES AT GABLE END TRUSS BUILDING SPECIFICATIONS. PFQlffPMrWTR GENERAL - ALL BUILDING CONSTRUCTION SHALL CONFORM TO THE 2003 EDITION OF THE THE FOLLOWING MINIMUM ROOF IAPHRAGM REQUIREMENTS ARE NEEDED, INTERNATIONAL BUILDING CODE CIBC 2003) AND ALL STATE &LOCAL BUILDING CODES. THESE ■ ROOF STEEL, 29 GAUGE GRAN] -RIB III, 36' WIDTH OR EQUIVALENT SPECIFICATIONS AND, PLANS ARE DESIGNED FOR 30 OR 40 PSF LIVE (SNOW) LOAD, 85 & 90 MPH ■ FIELD SCREWS, #10 x 11/2 T 9' D.C. (NEXT TO HIGH RIB) WIND SPEED, EXPOSURE B AND SESMIC DESIGN CATEGORY C. ■ EAVE AND RIDGE PURLIN SCR WS, #14 xl 1/2' AT BOTH SIDES OF DESIGN LOADS - ROOF LL = 30 OR 40 PSF ROOF DEAD LOAD = 5 PSF)KEACH MAJOR RIB THE FOLLOWING MINIMUM ENDWALL DIAPHRAGM REQUIRMENTS ARE NEEDEI CEILING LL = 0 PSF CEILING DL = 1 PSF ■ ENDWALL STEEL, 29 GAUGE GRAND -RIB III, 36' WIDTH OR EQUIVALEN w ROOF DL ALLOWS FOR A MAXIMUM OF 3' THICKNESS OF FIBERGLASS INSULATION• ■ FIELD SCREWS+ #10 x I f/2' 9' O,C. (NEXT TO HIGH RIB) W MAXIMUM SOIL BEARING PRESSURE = 2,000 PSF BASE SIDES 13F EACH MAJO �RIBHEADER SCREWS, #Ia x 1 v2 IG MAXIMUM SOIL BEARING PRESSURE IS BASED ON SAND, SILTY SAND, CLAY, CLAYEY SAND AND SANDY GRAVEL OR BETTER PER IBC TABLE 1804.2. LESSER SOIL CONDITIONS WILL REQUIRE DIAPHRAGM SCREWS REVIEW AND FOOTING SIZE ADJUSTMENT BY THE ENGINEER, CONCRETE - MINIMUM 28 DAY COMPRESSIVE STRENGTH F'c = 2,000 psi, 4 SACK MIX FOR FOOTINGS, CAST IN PLACE CONCRETE CONSTRUCTION SHALL CONFORM TO ACI 318-92. BETTER BY WWPA GRADINGD - STRUCTURAL ERULESL MAXOIMUMRMOISTURE CONTENT BETTER OR BE 9EM BY WEIGHT, gvEA GRID ER PURLINS�ON R pF DVALL BASE DGTRLSS TOP CHORD, NAILING SHALL CONFORM TO TABLE 2304.9.1 & OTHER APPLICABLE SECTIONS OF CHAPTER 23 OF THE IBC• ALL NAILS INTO PRESERVATIVELY TREATED WOOD SHALL BE ZINC COATED HOT DIP GALVANIZED, SILICONE BRONZE, COPPER OR STAINLESS STEEL. CCA TREATED WOOD SHALL CONFORM TO THE REQUIREMENTS OF AWPA STANDARDS C-16, C-22, C-23, C-24 & C-28, POSTS 7I]]�ippPPH A M S FOR BUILDINGS SHALL BE AS NOTED ON THE PLANS, ALL POST MATERIALS SHALL BE HEM -FIR NOTED ABOVEREWS] TYPICAL SCREW PATTERN, EXCEPT AS #2 OR BETTER, FULL DIMENSION AND GRADED BY WWPA GRADING RULES, HARDWARE SHALL BE SIMPSON OR APPROVED EQUAL. ALL BOLTS SHALL CONFORM TO ASTM A307. METAL PANELS MAY BE DELTA RIB STYLE, GALVANIZED OR PAINTED, 29 GAUGE THICKNESS, ASTM A653 STRUCTURAL STEEL SHEETING QUALITY (SQ), Fy = 80,0 ksi, ROOF PANELS SHALL BE FASTENED TO PURLINS WITH PLATED, GASKETED 1 1/2' LONG METAL TO WOOD FASTENERS. WALL PANELS SHALL BE FASTENED TO GIRTS WITH PLATED, GASKETED 1' OR LONGER METAL TO WOOD FASTENERS, PANELS SHALL BE S�p14AL INSTALLED AND FASTENED ACCORDING TO THE MANUFACTURER'S RECOMMENDATIONS, r' 05TH, SOIL COMPACTION - ALL BACKFILLED SOIL BENEATH FOOTINGS SHALL BE COMPACTED WITH A P /i VIBRATORY COMPACTOR TO 95% OF THE PROCTOR DENSITY AS DETERMINED BY ASTM A1557,METHD ; TRUSSESDSHALL BE DESIGNED BY AND BEAR THE SEAL OF AN ENGINEER REGISTERED TO 497 PRACTICE IN THE STATE OF WASHINGTON, 1, TRUSS LOADING, TOP CHORD LIVE LOAD = 30 OR 40 PSF q TOP CHORD DEAD LOAD = 5 PSF 1' - 2 - 16d NAILS �q OF TOP BOTTOM CHORD DEAD LOAD = 1 PSF WP' I11 cu III 6", 8' OR 10' POST .N-, III NAILING PATTERN FOR POST LAMINATIONS NOTE: 2" X 6" LAMINATE MUST BE A TREATED MEMBER AND MUST EXTEND TO THE BOTTOM OF THE FOOTING. LAMINATE MAY BE SPLICED ABOVE MID HEIGHT OF COLUMN POSTIFOOTING SCHEDULE 1Z . 24' SPANS 30 & 40 PSF LIVE LOAD POST COLUMN FOOTING KNEE BRACE CONCRETE SPACING "H" I WXD B••DIA. 'T" REQUIRED VOLUME Y _10'-0" B 0" _10'-0" B' x 6" 6" x &' 10" 3'-0•' 30"- - NO0.20 NO- - _ 0.20 - 16'- _70'-0 10'-0" 12:0" 6'X6" 1B" 3-0- -NO 1120 10:P tb� a' 161461 �e'-a° - --- - 6 %S'-- 6° x 11r' - _26 - 3. 3'-04. " -. O N_ rio ---- _a2A - z6' azd 10:6• 20' 0" 6' x 16' 21'• 3-0'• NO I 0.27 12-6' 6-0" &'X 6' 26' Y -O" NO 1141 120- 10'-U 6" X 6" 26_ 3:0" -NO _0.41 -12-0" '120'- 12.41 120" 1P• -i 12•;0" - 14'-0° -W-W 18 IF 20-0" 6• x 6" W/Z' X 6" ---------- 6' X 8"W12'X 6" WX WW&ii 6" -_ 17 S X ' Wtt X 6' x rmiz-, x 6! 29• -- -26' X -W' - 9'-0" 3-0' 3-0•' NO -- NO 1141 -- adi _No NO_ _n41 0.41 _2c 26 -26 3-2" r11 - -[-L4-4 POSTIFOOTING SCHEDULE 36 SPANS, 30 & 40 PSF LIVE LOAD POST I COLUMN FOOTING KNEE BRACE I CONCRETE SPACING "H" WXD '11"DIA. "T" REQUIRED VOLUME Y 10:6• -10'-0" S-0" 0 X 61 ex it 26' 3'-0" 3'-0"- NO -140=-1141 0.41 -29' --- _10'-0"_12'-U' _•10'-0' ----- 14:0" 6'-M6"W/Z'M6" 6" x 6"1Nt2" x 6" ------- 26_ -26' 3-0•' 3-0" _NO --a11441 NO -- - - -mi _vr-- 110141" 16-0 8" x 0" 26 3'•A•' NO _WF- -;We-6•XD"w1TX6" 26 3'-0 NO _0.41 1141 10:6' _10'-6' 10:0" 201.0' 2r'dr 24'-0"I&' WX8"WZ'X8- 6" M 96' W12"_X 6•' x 12' 2F- _26 26' 3'.0•• 3'-2 _ Y -T' -_NO _NO_ NO _0.41 _1144_ 0.45 120" 9-0" 6' X 8" 26' 3-0" 1147 6_ 6" X 8" 26 7-0" _NO N7 1147 -12_-P- 12-0 12-6' _12.0"- _12-0" _14:0' 16.0' 18'•0' _ 2D'-0' 22'-6' 8r% 8"Wli' X 8" 6'X8" wx16Wlt'X$" 6' X 16' 8" 31 12 6" x 92" Wl2" X 6" -2i7- 2S' - - 26' 2S'_ -28 _ 2S' -3•-0- 9'-0" - -- 3••0•' 3•-0" 3'4'-' 3'-2 _-NO_ NO -NO--1147 _NO -NO _0.47 1147 - - 1147 _1147 115 12-6 24'•Cr &' x 12' - 28 - 3'8" NO NO 0.56 POSTIFOOTING SCHEDULE 36 SPANS 30 & 40 PSF LIVE LOAD POST COLUMN FOOTING IKNEEBRACE CONCRETE SPACING "H" WXD -0-DIA. "T' REQUIRED VOLUME YD 10:6' -.__..--__.__ 10: D" 641" 1o• -a• 6' X 6" .--._ e" x 6- 2E' 3-0" NO 1147 -__---.__.-._.-- z6' 3• u" No 11117 _1_0'•0" 10'-0" 10•-6' - -•- 10:0" _10' 0 _ 10:6' _1_2:6' 14'-0" 16'•6' _20'-0° ?2•-d' 6' M S' Wtt• X 6" 6' X 6" WYL"x 6" 6'x 8" - w X 16' 6 X 96' WIZ. x-6' 26' -PO'- 21r -- - 26' 2S' _26' 2G 31-W' T -F 3-0" ---- 3.0" 3•-0" 3•.2° NO -NO _0_.41_ 0.47 NO -- NO NO 1147 1147 YES _a4i 847- (LSD 12. 126' -iifr 6-0" 10•-0^ W X S• s. % 32' 32'- 34" s a^ NO 0.62 -NO -1161 12-6' -12-P- - 12-0" 12'A" -14'-0' 16'-0' 18'-0" 6' N 8"W/7' M 8" S' x Ir - - W X 8" W 8" /T X it x 16' 32' 3v--3'-0"- 32 " 37 aF 3• -0•' Y -WI NO -N7 O.H2_ -M2 _NO NO _082 a61 -12-6' 12-0" -20'-0" _ 22'--0"_ 0 K 1P' WIT K 6 w R i 32- 32' 3•-11" 3'-2" (162- -NO NO 1166 _12.0"- 12-0" I 24'-M ir X 1T WJT X it I 3Z' 1 3.3•• NO afi8 POSTIFOOTING SCHEDULE 46 SPANS 30 & 40 PSF LIVE LOAD POST COLUMN FOOTING KNEE BRACE CONCRETE SPACING '•H" WXD B"DIA "T" REQUIRED VOLUME,Y 94O" W X 6" 36' 3'4• NO 0.55 _1D•-6' _ 10•-6' 12••0" g' x it 6'%6"Wl2"%6_ 36- _-36_ 3' -U•' 3'-0" O_ 11 _N55 NO _1155 _- 177:0 W-0" _14'•6' _16'-6' w_Ir 6-M 6' WIZ' x 6"_ 6' x S' 6' % 8"W_lr' X 6"_30" _3R'_ 36' 30" _31.0•' 3'-0•' Yz- 9•-0" -_NO YES_ _,155 _0.55 _-NO_ NO _1155 _10'-0"- 10'-6' _26-0 6' x 16' M_1U'W1T x S' 36' 3'-0" 3'-0" NO _0.55 36 NO _0.55 0.55 10••0 211'-6• 6' x 12' - - 36' 3-2" YES I ILSB 124' 643" W X 6" 33_ 3-01' NO _12.0_-16-6' 6' X (r 6"wl2' x 6" 57, 7.01. 3'-0" NO -NO _1186 _a66_ 1166 33" _126'=x _ 120 12-W _if- 16'-0" 6'x8" 6' x S'wt2"x6" -n-- 33" 31" 3'-0•' NO_ _ 1166 1166 NO _ 72-6' _ 18-p= 20:0 x "- _ 6' 10 6' X 16_W/T X 6' 3Y 33_ 3'-0•' 3'-0" NO - . NO _ 00.6"6 -. -12:6'_ 12.6' 22A" 6. x 12• -- 34' 9'-2" NO -a68 0.70 12.6' 24:0" w % 1T wig -X 6' 33' 3.2" NO 1172 POSTIFOOTING SCHEDULE 49 TO 62 -SPANS 3D&40PSF LAZE LOAD POST COLUMN FOOTING INNEEBRACE CONCRETE SPACING "FI•' I WxD "B"DIA. "T" REQUIRED VOLUME,Y 10•-6• S-0" w x fi 34•' 3'-0" NO 1170 ' w iD'-0 10:0 - --- 10'-6' 10:6' ------' iD'-0 10'-0 - -- 10- 0' _10'-U'_ 1F -D"_ 14:6•w 1 16'-0 16:0" -W 18'-0 2D'-0 --- 6 x &W/Z'x (r W_x 6" _ X 6" Wt2" X 6" ---- - Wil i 6' % S' Wit" X 6" -----....---------------------�-- 8"X8" W12" H 6' 6' X 16' 6Wltx-6'-3 - 34" 34'_ 34• -- -- 34" 94" 34" 34• - _3'-0" _3•-0• 3-0" -- 3-0" 9•-0" 101) -0.70- 0.70 1170 1170 -NO -NO- NO --..._- YES NO 3-0" 3-0" -0- _ NO_ YES O 1170_ 1170 - 0,70 10'-0 2,r.W 6• % 12' WJT X 6" 34' 3•40•' YES I 1170 12-0 --------- 12.0" --'--'-.- --- -- - 12-W 64)" 1D'-6' .-- •12'-0" --- --- 1A• -D= W X 6" 36' 34" 3'-0" .- -v--N 3.4. - -- - 3•-0" NO NO ------ NO 1179 1179 1179 WX 6'X6" W72' % 6" �------l---------- 6" X 6" W12 X 6" ----------- ---- @• x S' -3------No------ 36' 36' ---- 361' ---- NO ----- 1179 _12.6' 12-0" 16'.0" 6 X 8"wtY'X 6" 36' 74' -NO 1179 18'-0' 6' XX 16• --- 26_ 3'-0-0•• YES IL79 -12.0_ _12-6' 12_•6' 12-W 20:0 2Y•0' 24:0" 6' M_16' WIT X S' 6' % 1T WJT X_B' 6" X 1Z'WJT X S' 36' 3.0' NO -NO- NO _1179 _ aW 0.B3 36' 36' 3,2" 32" POSTIFOOTING SCHEDULE 54' TO 60' SPANS, 30 & 40 PSF LIVE LOAD POST COLUMN FOOTING, KNEE BRACE CONCRETE SPACING "H" WXD "B -DIA. -P REQUIRED VOLUME,Y 1101-Irl S-06' _10•- 12•-0 14' --0 . 16•.0 18:0 0•'" w X 6• x 0_' W X 6"Wl2"X 6" 6" x 8" .._ 6"x 8"WIZ'X 6" 36' 3'-0•' NO 0.79 -10'-6 ' _10:6' -1mr_ -10'-0 1D:0 _39' _ 36" 36 _3'0" 3.0" . 3-0,� 3-0" _ _NO NO =N0 _ NO _a_79_ 1179 _ _0.79- 0 x 16' -- -3S_ 36• 3-0" N8 _a79 a79 10:0" 10:6• -6' 2P'-0' 24:0 6' 8" x i(rw/T x v, 6' X 1T -36 36' 3'---0_•• 3'-2" NO N/ YES _1179 _0.71_ 1183 12-6'_ 6.0" 6" X 6"W12 X 6' X 6"L.-4..:: 7.0" 9'0" NO NO _1187 1187- -12-6 12-0" _10'-6' 14'-6" 6'x8"WIZ'xY-W' 111! 4 -0_mss'120" 09772:mu= _NO 12-0 12.6' 200" 22•-0" 24:0" 6 %16 WIT9-0• 6" X 12_W/Z' 6" X 1TWIT 3'-0" 3.2•' NO _NO- NO 0.97 -ILOT- 1.09 w 04 1. THE NEXT LARGER SIZE POST MAY BE SUBSTITUTED FOR POSTS WITH 2" X 6" LAMINATIONS. ENDWALL POSTS SHALL BE 6" X 6" ROUGH CUT HEM -FIR #2 TREATED • POSTS UP TO 16'-0" WALL HEIGHT. ABOVE 16' WALL HEIGHT, ENDWALL POSTS SHALL BE 6" X 8" ROUGH CUT HEM -FIR #(/2 POSTS. 180 7 3. FOOTINGS FOR ENDWALL POSTS SHALL BE A MINIMUM OF 18"0 X s �It3xe7�° �ti 3'-0" DEEP FOR WALL HEIGHTS TO 16'-0". ABOVE 16' WALL HEIGHT, SIONALFOOTINGS SHALL BE 24"0 X 3'-4" DEEP. 4. ABOVE FOOTING DESIGNS ARE FOR POST FRAME BUILDINGS WITH _-t CONCRETE FLOORS (CONTRAINED POSTS). IF BUILDINGS WILL NOT HAVE .E$RIItEiSy, ).2 .$9.;07 nI DEPTH CX 4E. FLOOR, INCREASE FOOTING DIAMETER X 2" & FOOTING W Im" BEKE ENGINEERING 2913 E. 61st Court STRUCTURAL DESIGN FOR POST FRAME BUILDINGS 12' TO 60' SPANS, 30 & 40 PSF LIVE LOAD, 2003 IBC EXCALIBUR STEEL STRUCTURES, INC. P. 0. 'BOX 14991 SPOKANE, WASHINGT( BY._ ---- `DATE . DRAWN AMBEKE 01-08-06 CHECKED BY DATE DESCRIPTION OF CHANGE PROJECT PDD6 SCALE,N.T.C. 99214-0991 DRAWING NO., EXCALIBUR.IBC2003.BOLT 12 PROVIDE DIAGRAMS AND ENGINEERING LAYOUTS FOR ROOF TRUSG =S, BEAMS AND FLOOR SYS' EMS PRIOR TO FRAMING INSPECTIONS CITY COPY THIS BUILDING SUBJECT TO FIELD INSPECTION CORRECTIONS RE IElFCR SjPO'( E.