Loading...
2006, 05-04 Permit App: 06001660 RemodelProject Number: 06001660 Inv: 1 Application THIS IS NOT A PERMIT Penalties will be assessed for commencing work without a permit Date: 05/04/2006 Page 1 of 2 Project Information: /ffim_ Permit Use: enlarge bedroom via moving wall and replace doors Contact: CORDERO, HOLLY & trim Address: 13224 E TALLTREE RD C - S - Z: SPOKANE VALLEY, WA 99216 Setbacks: Front Left: Right: Rear: Phone: (509) 924-1506 Group Name: Site Information: Project Name: .,PA3 Plat Key: 001223 Name: HILLCREST ACRES 02ND ADD District: Sout Parcel Number: 45274.1305 Block: SiteAddress: 13224 E TALL TREE RD Location:: CSV Zoning: UR -3.5 Water District: Urban Residential 3.5 Lot: Owner: Name: CORDERO, HOLLY Address: 13224 E TALLTREE RD SPOKANE VALLEY, WA 99216 Hold: ❑ Area: .00 Acres Width: 116 Depth: 119 Right Of Way (ft): 50 Nbr of Bldgs: 0 Nbr of Dwellings: 1 Review Information: Review Building Plan Review Permits: Released By: Originally Released: 05/04/2006 By: TMELBOU Contractor: OWNER Building Permit Firm: OWNER Phone: (000) 000-0000 This Application: Total Project: Description Grp Iya [aNotes Sq Ft Valuation Sq Ft Valuation 1&2 FAMILY R-3 VB OWNER 0 $4,500.00 0 $4,500.00 Totals: 0 $4,500.00 0 $4,500.00 Item Description Units Unit Desc Fee Amount RESIDENTIAL PERMIT FEE 1 SELECT $111.25 WSBC SURCHARGE 1 SELECT $4.50 SF PLNS RVW < 7999 SQ FT 1 SELECT $44.50 Permit Total Fees: $160.25 Operator: AMB Printed By: AMB Print Date: 05/04/2006 Project Number: 06001660 Inv: 1 Notes: Application THIS IS NOT A PERMIT Penalties will be assessed for commencing work without a permit Date: 05/04/2006 Page 2 of 2 Payment SummaryNIMOMISTS Permit Type Building Permit VILIMEMOSEMISIZET Fee Amount Invoice Amount Amount Paid Amount Owing $160.25 $160.25 $0.00 $160.25 $160.25 $160.25 $0.00 $160.25 Disclaimer: Submittal of this application certifies the owner (or person(s) authorized by the owner) has both examined and finds the information contained within to be true and correct, and agrees that all provisions of laws and/or regulations governing this type of work will be complied with. Subsequent issuance of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the code or of any other state or local laws or ordinances. Signature: Operator: AMB Printed By: AMB Print Date: 05/04/2006 Project Number: 06001660 Inv: 1 Application THIS IS NOT A PERMIT Penalties will be assessed for commencing work without a permit Date: 5/2/2006 Page 1 of 1 Project Information: Permit Use: enlarge bedroom via moving wall and replace doors & trim Setbacks: Front Site Information: Plat Key: 001223 Name- HILLCREST ACRES 02ND ADD Left: Right: Rear: Contact: CORDERO, HOLLY Address: 13224 E TALLTREE RD C - S - Z: SPOKANE VALLEY, WA 99216 Phone: (509) 924-1506 Group Name: Project Name: District: Sout Parcel Number: 45274.1305 Block: SiteAddress: 13224 E TALL TREE RD Location:: CSV Zoning: UR -3.5 Water District: Urban Residential 3.5 Area: .00 Acres Lot: Owner: Name: CORDERO, HOLLY Address: 13224 E TALLTREE RD SPOKANE VALLEY, WA 99216 Hold: ❑ Width: 116 Depth: 119 Right Of Way (ft): 50 Nbr of Bldgs: 0 Nbr of Dwellings: 1 Review Information: Review Building Plan Review Permits: Released By Contractor: OWNER Notes:��. Building Permit Firm: OWNER Phone: (000) 000-0000 Payment Summary: uselasom.. Disclaimer: Submittal of this application certifies the owner (or person(s) authorized by the owner) has both examined and finds the information contained within to be true and correct, and agrees that all provisions of laws and/or regulations governing this type of work will be complied with. Subsequent issuance of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the code or of any other state or Local laws or ordinances. Signature: Operator: AMB Printed By: AMB Print Date: 5/2/2006 Spokane �,®•'�Valley Community Development Permit Center 11707 E Sprague Ave, 106 Spokane Valley, WA 99206 P3,1:: 0 (509)688-0036 FAX; (509)688-0037 www.sP okanevalleyiotq' Residential Construction Permit Application PERMIT NUMBER: telo PERMIT FEE: ❑ New Construction nAccessory Bldg 7' Addition/Remodel n Deck n Other: SITE ADDRESS -3aq ASSESSORS PARCEL NO: 4 LEGAL DESCRIPTION: Building Owner: DIMENSIONS: # OF STORIES: sName: 1 al 1OI(t ((„c ->f1(() Name: 54, / f Address: I Z/14 ( -17i It 7 c' -k' /Of City: i1,�t State: Ev11 Zip: e l2/�� Phone: 4)c., So? 91 / Fax: S-06 HEAT SOURCE: Contact Person Name: ;/bI'1/ (/ cy, ?c Phone: 7)c -i- /y'j�) Contractor: DIMENSIONS: # OF STORIES: TOTAL HABITABLE SPACE: MAIN FLOOR TO SQ. FTG: Name: 54, / f UNFIN BASEMENT SQ. FTG: IMPERVIOUS SURFACE AREA: FINISHED BASEMENT SQ. FTG: GARAGE SQ. FTG: Address: / 3 "L 'L t/ C 7-6 // Tee „+E/ CONSTRUCTION TYPE: HEAT SOURCE: City:✓6f1 a� State��� Zi2lfr� Phone: ,(%, v / s) 6 Fax: Contractor Lic No: Exp Date: City Business Lic. No: Describe the scope of work in detail: Cost of Project: $ '1.5 60 no i,trl�r;or twit -in 'f,✓lGRc/-r' deeiv)c w -S' **************The following MUST be comulete: (write N/A if not annlicable)********************** HEIGHT TO PEAK: DIMENSIONS: # OF STORIES: TOTAL HABITABLE SPACE: MAIN FLOOR TO SQ. FTG: 2Nu FLOOR SQ. FTG: UNFIN BASEMENT SQ. FTG: IMPERVIOUS SURFACE AREA: FINISHED BASEMENT SQ. FTG: GARAGE SQ. FTG: DECK/COV. PATIO SQ. FTG: 30% SLOPES ON PROPERTY: # OF BEDROOMS: CONSTRUCTION TYPE: HEAT SOURCE: SEWER OR SEPTIC? The permitee verifies, acknowledges and agrees by their signature that: 1) If this permit is for construction of or on a dwelling, the dwelling is/will be served by potable water. 2) Ownership of this City of Spokane Valley Permit inure to the property owner. 3) The signatory is the property owner or has permission to represent the property owner in this transaction. 4) All construction is to be done in full compliance with the City of Spokane Valley Development Code. Referenced codes are available for review at the City of Spokane Valley Permit Center. 5) This City of Spokane Valley Permit is not a permit or approval for any violation of federal, state or local laws, codes or ordinances. 6) Plans or additional information may be required to be submitted, and subsequently approved before this application can be processed. Signature I Method of Payme ❑ Cash Bankcard #: Authorized Signature: REVISED 8/25/2005 r. 0 Check z 666, Date ❑ Mastercard 0 VISA Expires: VIN#: 8'-8" EMERGENCY EGRESS REQUIREMENTS FROM SLEEPING ROOMS 2'-0" 1) NET CLEAR OPENING. 5.7 SQUARE FEE GRADE fl �fl PENING (MAX 44") 5.0 INCHES FEE E,1Tt l NTNG HEIGHT 31 NET CLEAR OPENING WI'1TH 20 INCHES 41 MAXFINISHED SILL HEIGHT 44" ABOVE FLOG i ME RGE NCY ESCAPE & RESCUE OPENING SHALL BE :'E •,ATI,`NAI FROM THE INSIDE OF THE ROOM WITHOU IHE 'R' 1\ YS OR TOOLS Egress windows openable 5.7 sq. ft. - 44" sill / N U s rA B L R6-02. s- -0 1- (1)w O J U (S� WHEN INTERIOR ALTERATIONS, REPAIRS OR ADDITIONS REQUIRING A PERMIT OCCUR, OR WHEN ONE OR MORE SLEEPING ROOMS ARE ADDED OR CREATED IN EXISTING DWELLINGS, THE DWELLING UNIT SHALL BE PROVIDED WITH SMOKE ALARMS LOCATED AS REQUIRED FOR NEW DWELLINGS. SMOKE ALARMS SHALL BE INTERCON- NECTED AND HARD WIRED IN SUCH A MANNER THAT THE ACTIVATION OF ONE ALARM WILL ACTIVATE ALL ALARMS. (BEDROOMS, AREAS APPROACHING BEDROOMS, VAULTED CEILING WITH RISE OF 24' & ON EACH FLOOR) 5'-1" 5'-7" - 3'-4" ® EXHAUST FANS 1.00 CFM kitchen 50 CFM bathrooms & laundry ‘rn- 1 I; A \12,1,k 1)1 (0U,��, )3-i14 ria/112-u Ari„ 11-,) WINDOW WELL: Min. 9 sq. ft. horizontal area. Min. 3 ft. horizontal projection and width. Max. 44 in. vertical depth without a ladder FLOORS TABLE R502.5(1) GIRDER SPANS' AND HEADER SPANS' FOR EXTERIOR BEARING WALLS Douglas fir -larch hem -fir southern pine and spruce -pine -fir" and required number of jack studs) t..4...........�r...,.-. GIRDERS AND HEADERS SUPPORTING SIZE > > GROUND SNOW LOAD (psf)' 30 50 Building width` (feet) 20 28 36 20 28 36 Span NJ° Span NJ° Span NJ° Span NJ° Span NJ° Span NJ° Roof and ceiling 2-2x4 3-6 1 3-2 1 2-10 1 3-2 1 2-9 1 2-6 1 2-2x6 5-5 1 4-8 1 4-2 1 4-8 1 4-1 1 3-8 2 2-2x8 6-10 1 5-11 2 5-4 2 5-11 2 5-2 2 4-7 2 2-2x10 8-5 2 7-3 2 6-6 2 7-3 2 6-3 2 5-7 2 2-2x12 9-9 2 8-5 2 7-6 2 8-5 2 7-3 2 6-6 2 3-2x8 8-4 1 7-5 1 6-8 1 7-5 1 6-5 2 5-9 2 3-2x10 10-6 1 9-1 2 8-2 2 9-1 2 7-10 2 7-0 2 3-2x12 12-2 2 10-7 2 9-5 2 10-7 2 9-2 2 8-2 2 4-2x8 7-0 1 6-1 2 5-5 2 6-1 2 5-3 2 4-8 2 4-2x10 11-8 1 10-6 1 9-5 2 10-6 1 9-1 2 8-2 2 4-2x12 14-1 1 12-2 2 10-11 2 12-2 2 10-7 2 9-5 2 Roof, ceiling and one center -bearing floor 2-2x4 3-1 1 2-9 1 2-5 1 2-9 1 2-5 1 2-2 1 2-2x6 4-6 1 4-0 l 3-7 2 4-1 1 3-7 2 3-3 2 2-2x8 5-9 2 5-0 2 4-6 2 5-2 2 4-6 2 4-1 2 2-2x10 7-0 2 6-2 2 5-6 2 6-4 2 5-6 2 5-0 2 2-2x12 8-1 2 7-1 2 6-5 2 7-4 2 6-5 2 5-9 3 3-2x8 7-2 1 6-3 2 5-8 2 6-5 2 5-8 2 5-1 2 3-2x10 8-9 2 7-8 2 6-11 2 7-11 2 6-11 2 6-3 2 3-2x12 10-2 2 8-11 2 8-0 2 9-2 2 8-0 2 7-3 2 4-2x8 5-10 2 5-2 2 4-8 2 5-3 2 4-7 2 4-2 2 4-2x10 10-1 1 8-10 2 8-0 2 9-1 2 8-0 2 7-2 2 4-2x12 11-9 2 10-3 2 9-3 2 10-7 2 9-3 2 8-4 2 Roof, ceiling and one clear span floor 2-2x4 2-8 1 2-4 1 2-1 1 2-7 1 2-3 1 2-0 1 2-2x6 3-11 1 3-5 2 3-0 2 3-10 2 3-4 2 3-0 2 2-2x8 5-0 2 4-4 2 3-10 2 4-10 2 4-2 2 3-9 2 2-2x10 6-1 2 5-3 2 4-8 2 5-11 2 5-1 2 4-7 3 2-2x12 7-1 2 6-1 3 5-5 3 6-10 2 5-11 3 5-4 3 3-2x8 6-3 2 5-5 2 4-10 2 6-1 2 5-3 2 4-8 2 3-2x10 7-7 2 6-7 2 5-11 2 7-5 2 6-5 2 5-9 2 3-2x12 8-10 2 7-8 2 6-10 2 8-7 2 7-5 2 6-8 2 4-2x8 5-1 2 4-5 2 3-11 2 4-11 2 4-3 2 3-10 2 4-2x10 8-9 2 7-7 2 6-10 2 8-7 2 7-5 2 6-7 2 4-2x12 10-2 2 8-10 2 7-11 2 9-11 2 8-7 2 7-8 2 Roof, ceiling and two center -bearing floors 2-2x4 2-7 1 2-3 1 2-0 1 2-6 1 2-2 1 1-11 1 2-2x6 3-9 2 3-3 2 2-11 2 3-8 2 3-2 2 2-10 2 2-2x8 4-9 2 4-2 2 3-9 2 4-7 2 4-0 2 3-8 2 2-2x10 5-9 2 5-1 2 4-7 3 5-8 2 4-11 2 4-5 3 2-2x12 6-8 2 5-10 3 5-3 3 6-6 2 5-9 3 5-2 3 3-2x8 5-11 2 5-2 2 4-8 2 5-9 2 5-1 2 4-7 2 3-2x10 7-3 2 6-4 2 5-8 2 7-1 2 6-2 2 5-7 2 3-2x12 8-5 2 7-4 2 6-7 2 8-2 2 7-2 2 6-5 3 4-2x8 4-10 2 4-3 2 3-10 2 4-9 2 4-2 2 3-9 2 4-2x10 8-4 2 7-4 2 6-7 2 8-2 2 7-2 2 6-5 2 4-2x12 9-8 2 8-6 2 7-8 2 9-5 2 8-3 2 7-5 2 (continued) 90 2003 INTERNATIONAL RESIDENTIAL CODE® TABLE R502.5(1)--continued GIRDER SPANS'AND HEADER SPANS'FOR EXTERIOR BEARING WALLS (Maximum spans for Douglas fir-larch,hem-fir,southern pine and spruce-pine-fir°and required number of jack studs) GROUND SNOW LOAD(pair 30 5D Building width'(feet) GIRDERS AND 20 28 36 20 28 36 HEADERS SUPPORTING SIZE Span NJ° Span NJ° Span NJ° Span NJ° Span NJ° Span Ne 2-2x4 2-1 1 1-8 1 1-6 2 2-0 1 1-8 1 1-5 2 2-2x6 3-1 2 2-8 2 2-4 2 3-0 2 2-7 2 2-3 2 2-24 3-10 2 3-4 3 3-0 3 3-10 2 3-4 2 2-11 3 2-2x10 4-9 2 4-1 3 3-8 3 4-8 2 4-0 3 3-7 3 2-2x12 5-6 3 4-9 3 4-3 3 5-5 3 4-8 3 4-2 3 Roof Baling and two clear span 3-24 4-10 2 4-2 2 3-9 2 4-9 2 4-1 2 3-8 2 Boor 3-2x10 5-11 2 5-1 2 4-7 3 5-10 2 5-0 2 4-6 3 3-2x12 6-10 2 5-11 3 5-4 3 6-9 2 5-10 3 5-3 3 4-24 5-7 2 4-10 2 4-4 2 5-6 2 4-9 2 4-3 2 4-2x10 6-10 2 5-11 2 5-3 2 6-9 2 5-10 2 5-2 2 4-2x12 7-11 2 6-10 2 6-2 3 7-9 2 6-9 2 6-0 3 For SI: 1 inch=25.4 mm,1 pound per square foot=0.0479 kN/m2. a. Spans are given in feet and inches. b. Tabulated values assume#2 grade lumber. c. Building width is measured perpendicular to the ridge.For widths between those shown,spans are permitted to be interpolated. d.NJ-Number of jack studs required to support each end.Where the number of required jack studs equals one,the header is permitted to be supported by an ap- proved framing anchor attached to the full-height wall stud and to the header. e. Use 30 psi ground snow load for cases in which ground snow load is less than 30 psi and the roof live load is equal to or less than 20 psi. • 2003 INTERNATIONAL RESIDENTIAL CODE® 91 FLOORS TABLE R502.5(2) GIRDER SPANS' AND HEADER SPANS' FOR INTERIOR BEARING WALLS Douglas fir -larch hem -fir, southern pine and spruce -pine -fir° and required number of jack studs) HEADERS AND GIRDERS SUPPORTING SIZE BUILDING WIDTH' (feet) 20 28 36 Span NJ° Span NJ° Span NJ° One floor only • 2-2x4 3-1 1 2-8 1 2-5 1 2-2x6 4-6 1 3-11 1 3-6 1 2-2x8 5-9 1 5-0 2 4-5 2 2-2x10 7-0 2 6-1 2 5-5 2 2-2x12 8-1 2 7-0 2 6-3 2 3-24 7-2 1 6-3 1 5-7 2 3-2x10 8-9 1 7-7 2 6-9 2 3-2x12 10-2 2 8-10 2 7-10 2 4-2x8 9-0 l 7-8 1 6-9 1 4-2x10 10-1 1 8-9 .1 7-10 2 4-2x12 11-9 1 10-2 2 9-1 2 Two floors 2-2x4 2-2 1 1-10 1 1-7 1 2-24 3-2 2 2-9 2 2-5 2 2-24 4-1 2 3-6 2 3-2 2 2-2x10 4-11 2 4-3 2 3-10 3 2-2x12 5-9 2 5-0 3 4-5 3 3-24 5-1 2 4-5 2 3-11 2 3-2x10 6-2 2 5-4 2 4-10 2 3-2x12 7-2 2 6-3 2 5-7 3 4-24 6-1 1 5-3 2 4-8 2 4-2x10 7-2 2 6-2 2 5-6 2 4-2x12 8-4 2 7-2 2 6-5 2 For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm. a. Spans are given in feet and inches. b. Tabulated values assume #2 grade lumber c. Building width is measured perpendicular to the ridge. For widths between those shown, 'spans are permitted to be interpolated. d. NJ - Number of jack studs required to support each end. Where the number of required jack studs equals one, the header is permitted to be supported by an ap- proved framing anchor attached to the full -height wall stud and to the header. R502.6 Bearing. The ends of each joist, beam or girder shall have not less than 1.5 inches (38 mm) of bearing on wood or metal and not less than 3 inches (76 mm) on masonry or con- crete except where supported on a 1 -inch -by -4 -inch (25.4 mm by 102 mm) ribbon strip and nailed to the adjacent stud or by the use of approved joist hangers. R502.6.1 Floor systems. Joists framing from opposite sides over a bearing support shall lap a minimum of 3 inches (76 mm) and shall be nailed together with a minimum three 10d face nails. A wood or metal splice with strength equal to or greater than that provided by the nailed lap is permitted. R502.6.2 Joist framing. Joists framing into the side of a wood girder shall be supported by approved framing an- chors or on ledger strips not less than nominal 2 inches by 2 inches (51 mm by 51 mm). 92 R502.7 Lateral restraint at supports. Joists shall be sup- ported laterally at the ends by full -depth solid blocking not less than 2 inches (51 mm) nominal in thickness; or by attachment to a header, band, or rim joist, or to an adjoining stud; or shall be otherwise provided with lateral support to prevent rotation. Exception: In Seismic Design Categories Di and D2, lateral restraint shall also be provided at each intermediate support. R.502.7.1 Bridging. Joists exceeding a nominal 2 inches by 12 inches (51 mm by 305 mm) shall be supported laterally by solid blocking, diagonal bridging (wood or metal), or a continuous 1 -inch -by -3 -inch (25.4 mm by 76 mm) strip nailed across the bottom of joists perpendicular to joists at intervals not exceeding 8 feet (2438 mm). R502.8 Drilling and notching. Structural floor members shall not be cut, bored or notched in excess of the limitations speci- fied in this section. See Figure R502.8. 2003 INTERNATIONAL RESIDENTIAL CODE® c r neo Residential Direct Vent Instruction Manual For Gas Water Heaters NOT FOR USE IN MOBILE HOMES GEFFICIENCY RATING CERTIFIED ama GAMA certification applies to all residential gas water heaters with capacities of 20 to 100 gallons with input rating of 75,000 BTU/Hr. or less. ALL TECHNICAL AND WARRANTY QUESTIONS: SHOULD BE DIRECTED TO THE LOCAL DEALER FROM WHCOM011 P TI*LISTE OtTN WARRANTY SHEET WHICHAs PURCHASED. IF OU ARE CAME WITH THEESSFUL, PLEASE WA ER HEATER. TO THE For Your Safety AN ODORANT IS ADDED TO THE GAS USED BY THIS WATER HEATER WARNING: If the information in these instructions are not followed exactly, a fire or explosion may result, causing property damage, personal injury, or death. -Do not store or use gasoline or other flammable vapors and liquids in the vicini- ty of this or any other appliance. -WHAT TO DO IF YOU SMELL GAS • Do not try to light any appliance. • Do not touch anyelectrical switch; do not use any phone in your building. • Immediately call yourgas supplier from a neighbor's phone. Folow the gas suppli- er's instructions. • If you can not reach your gas supplier, call the fire department. -Installation and service must be performed by a qualified installer, service agency or the gas supplier. Save this Manual for Future Reference. WARNING Improper installation, adjustment, alteration, service or maintenance can cause DEATH, SERIOUS BODILY INJURY, OR PROPERTY DAMAGE. Refer to this manual for assistance or consult the local gas utility for further information. WARNING Flammable vapors may be drawn by air cur- rents from other areas of the structure to this appliance. WARNING READ THE GENERAL SAFETY SECTION BEGINNING ON INSIDE COVER AND THEN THIS ENTIRE MANUAL BEFORE INSTALLING OR OPERATING THIS WATER HEATER. 0291234-03 CITY COPY THIS BUILDING SUBJECT TO FIELD INSPECTION CORRECTIONS REVIEWEG FOP 2 a...,,.PLANCE o