1994, 04-14 Permit: 93008752 Energy Code Inspect SPOKANE COUNTY DEPARTMENT OF BUILDINGS o SITE 6� 9f(e s o RESIDENTIAL ENERGY CODE INSPECTION CHECKLIST ADDRESS �4�l [�/.�:LP......... . ................ o PERMIT C 3 -'7,-5--2 o SUB-SSB O i> o PERIMETER INSULATION R- <GRAVEL BASE 0 PLASTIC MEMBRANE 0 o DATE 0 o APPROVED FOR COVER BY INSULATION CAULK Io o . INDOWS&DOORS PER PLANS a(WINDOWS&DOORS CAULKED .VAPOR RETARDERS: WALL o -• ADVANCED FRAMING: XSOLEPLATE CAULKED CEIUNG WALLS '� ckPLUMBING//ELECTRICAL q-n IC VENT BAFFLES o CEILINGS PENETRATIONS CAULKED 0 COMBUSTION AIR DUCTS • WALL INSULATION: R- q SEALED DUCTWORK INSTALLED o �• VAULTED CEIUNG: R= �EXI-IAUST FANS/DUCTS �INSTALLED E VENTILATION o • =ATT INSTALLATION INSTALLED ARApON FAN CIRCUIT o TECHNIQUES 0RECESSED UGHTS 0 o 1 DATE 0 o APPROVED FOR COVER BY O ` O IENERGY CODE FINAL 0 1(>1 - MECHANICAL SYSTEMS • WEATHERSTRIPPING PLUMBING R HEATER PAD O BATH EXHAUST DOORS &WINDOWS o • KITCHEN EXHAUST 9CATTIC&CRAWL ACCESSES z,,SHOWER FLOW • SWITCH &OUTLET COVER FIREPLACE/WOODSTOVE EXHAUST AUTOMATIC WHOLE HOUSE PLATES FIREPLACE DOORS MAKE-UP AIR INTAKES ° FLUE DAMPER • DUCTWORK INSULATION COMBUSTION AIR EQUIPMENT INSTRUCTIONS b o FLOOR RAVI C, V�ILSPACE GROUND COVER - •, EATING FUEL &SYSTEM TYPE: ATTIC R- 3 -7 & t(LSPACE VENTILATION • Ei a4,BELOW-GRADE WALLS R-15_ $\RADON VENT&LABEL RADON MONITOR q(BATT INSTALLATION o TECHNIQUES • SERIAL NUMBERF__ — ._ ciwi Al APPRC)VAI BY 12 'c-0145 %i - DATE 4WTSUN 5 .3 1991 WA STATE ENERGY CGDE COMPLIANCE REPORT 02/18/93 FILE: C: \WATTDATA\LD1263 .WS HOUSE ID: LD1263 0 Site: WELLINGTON Analyst : TAS ( MARQUESS ) SPOKANE , WA Jurisdiction: SPOKANE COUNTY � ( ) - Utility : WWP Homeowner : House Type : Single Family Floor Area: 2649 ft2 Builder : LANCE DOUGLAS Weather Data : Spokane , WA Climate Zone : 2 ( 509 )483-6532 The PROPOSED design *COMPLIES* with 1091 WA State Energy Code . 'REFERENCE PROPOSED COMPONENT PERFORMANCE 519 505 Btu/hr-F ENERGY BUDGET 9 . 7'4 9 .86 kWh/ft.2-yr REFERENCE DESIGN Reference Component Value X Area = UA BG Wall. 3 .5 ' U-0 .041 553 22 .7 BG Slab 3 .5 ' F-0 .640 158ft 101 . 1 Floor U-0 .029 27 0 .0 Glazing @15 U--0 .600 397 .4 ">38 .4 Doors U-0 .400 21 .0 8 .4 AG Wall U-0 .062 1708 105 .9 Ceiling , Attic U-0 .031 1333 41 .3 Infiltration ACH-0 .350 17216ft3( 104 .2 ) Reference UA 519 PROPOSED DESIGN COMPONEN1S Component Description Value X Area = UA BC; Wall. RO Uninu tit:: .-d 3 . 5 ' depth U-0 .271 553 149 .9 BG Slab F--0 .511 158ft 80 .7 Floor R30 vented joist 16oc U-0 .029 27 0 .8 . 'Glazing X10% **2 glaze vinyl 3/4 " air space U-0 .480 224 .9 108 .0 *2 alz .vinyl "3/4 "air space sld 'g dr . U--0 .520 35 .0 18 .2 Items in parentheses not included in COMPONENT PERFORMANCE totals . ** Denotes non-standard values - check calculation of thermal value . _-= = _ -_ ___ - Page 1 --•------ -_ --- -- ft.4ATTSCJN 5 .3 1991 WA STATE ENERGY CODE COMPLIANCE REPORT 02/18/93 FILE : C : \WATTDATA\LD1263 .WS HOUSE ID: LD1263 Doors **Metal Insul , w/ Raised Panel U-0 .220 21 .0 4 .6 AG Wall R19 ADV Lap Wood U-0 .055 1845 101 .5 Ceiling R38 blown Attic STD baffled U-0 .031 1333 41 .3 Infiltration Standard Air Sealing ACH-0 .350 17216ft3 ( 104 .2 ) Proposed UA 505 Struc Mass Light Frame , Sheetrock walls M- 3 .000 1333 3999 **Slap w/ no cover M-10 .000 1316 13160 HEATING/COOLING/VENTILATING SYSTEMS PROPOSED Heating System Type: Gas Furnace Make: unknown/ Model : unknown/ System Efficiency: 80 Modified Efficiency : 76 Design ACH: 0 .60 Heating Load( at 66F dt ): 46283 Btu/hr System Size : 46 .3 kBtu/hr Maximum Size @1.50% : 69 .5 kBtu/hr Average Annual Heat : 116 MBtu Annual Cost : $ 649 Ventilation System: Integrated 'w/Forced Air Furnace Cooling System: SEER : 0 .0 'CUYiducted ) Cooling Load( at 12F dt ): 16321 Btu/hr Recommended Size @125% : 1 .9- tons Annual cool requirement : **x= kWh/yr Solar Access: Partially Shaded PROPOSED DUCT SYSTEM Location Avg Rvalue Surface Area SUPPLY All in heated space RETURN All in heated space Page 2 - WATTSUN 5 .3 1991 WA STATE ENERGY CODE COMPLIANCE REPORT 02/18/93 FILE: C :\WATTDATA\LD1263 .WS HOUSE ID: LD1263 GLAZING ORIENTATION PROPOSED PROPOSED South 1O4 .Oft2 North 155 .9ft2 Southeast : Northwest - East • West • Northeast. : Southwest. : • • Economic and energy consumption estimates are designed for comparative purposes only , Actual cost for heating will vary depending on weather conditions , occupant lifestyle and other factors . WATTSUN 5 .3 COMPONENT CHECKLIST 02/18/93 FILE : C :\WATTDATA\LD1263 .WS HOUSE ID: LD1263 Name : Floor Area : 2649 ft2 Address: WELLINGTON Heating Type : Gas Furnace Reference : 1991 WA State Energy Code FOUNDATION INSPECTION Sub-slab radon requirement : Where required , slab is poured over a. 4" thick coarse gravel. base . A 6-mil poly soil gas retarder membrane is installed between the gravel and slab . All tears , seams , and joints in membrane are sealed . A radon vent pipe of at least 3" in diameter runs from each separate gravel area to 12" above eaves . Below grade walls : ( RO Uninsulated 3 .5 ' depth 553 .0 ft2 ) Insulation is installed from the top of the below grade wall to the bottom of the footing . Any insulation above grade is protected from exposure . Slab Sealing: All penetrations , cracks and joints in concrete slab or wallsctr sealed with a urethane type sealant. to limit the movement of soil gases into the indoor air . FRAMING INSPECTION Approved plans: Are available onsite • Air leakage: Top and bottom of mudsill and soleplate are caulked/sealed . Rim joists between stories are caul ked/sealed . All holes in building envelope ( i .e . exterior ceilings , walls , and floors ) are caulked/sealed , including all electrical , plumbing , and HVAC penetrations . Outlets , switch boxes and recessed fixtures on exterior walls are caulked/sealed with approved sealant , or have foam face gaskets installed . Any .recessed lights are IC rated , air tight , and sealed to the ceiling sheetrock . Wall framing: • Net wall area : 1845 ft2 Advanced framing with studs spaced 24" o .c . , R-10 insulated headers and no isolated cavities which cannot be insulated Structural panels: All structural sheathing is stamped "Exposure I " or "Exterior " . Windows: - _ Page 1 WATTSUN 5 .3 COMPONENT CHECKLIST 02/18/93 FILE: C: \WATTDATA\LD1263 .WS HOUSE ID: LD1263 ( 2 glaze vinyl 3/4 " air space 224 .9 ft2 ) ( 2 glz .vi.n I 3/4 "a:ir" space sld 'g dr 35 .0 ft2 ) W.1. 'ii..i.:;ws are installed as shown on the approved plans . The rough opening around windows and doors is caulked/sealed . Exhaust tans , spot. ventilation: Bathroom fans are 50 CFM , kitchen fans are 100 CFM . Fan ducting has minimal bends and terminates outside of the building . The whole house exhaust fan is between: 105 .0 and 150 .0 CFM . INSULATION INSPECTION Wall insulation: ( R19 ADV Lap Wood 1845 .0 ft2 ) insulation fills all exterior wall cavities . It is not compressed and is cut to fit around wires , pipes , and outlet boxes . Recessed fixtures in exterior walls have at least R--5 insulation behind them . Vapor retarder : 1 .0 perm or less vapor retarder ( e .g . poly , kraft paper , perm rated paint ) is installed on the warm side of insulation in floors , ceilings and walls . • Recessed lights: Any recessed light fixtures in the thermal envelope are certified under ASTM E-283 and labeled showing compliance , or are sealed around the exterior to be air tight . FINAL INSPECTION Crawl space moisture barrier : A six mil black pob'ethelene ground cover is installed on cr awlspai. c,! floor . . Floor Insulation : ( R30 vented Joist 16oc 27 .0 ft2 ) insulation is supported in a permanent manner without compression . Craw.lpace ventilation: At least. 0 . 1 Ft2 o . net free ventilation is provided in the vented craw.lspac;e Pipe i nsu.I_at:.ion: All. water pipe., in unheated spaces are insulated to R-3 . Hot. water : Electric water heater labeled as 'meeting ASHRAE Standard 90A-1980 or 1987 NAECA . Tank has R-10 nor--compressible pad underneath if located over slab or in unconditioned space . Shower heads allow a maximum flow rate ei 3 .0 gallons per minute . -- --- - - --= = page 2 "-------- WATTSUN 5 .3 COMPONENT CHECKLIST 02/18/93 FILE : C: \WATTDATA\LD1263 .WS HOUSE ID : LD1263 Doors : ( Metal I nsu 1. , w/ Raised Panel 21 .0 ft2 ) Weatherstripping , threshhold , and doorsweep are properly adjusted a rt ci seal wel1 . Ceiling : ( R38 blown Attic STD baffled 1333 .0 ft2 ) Insulation is installed to the manufacturer 's recommended density and coverage . Attic access doors are insulated and weatherstripped . Heating system: unknown/ unknown The heating system does not exceed: 69451 BTUs . Ventilation : The ventilation system has been checked for proper operation . If -designed for intermittent operation , the system is controlled automatically by a time-of-day timer set to run for a minumurn of eight hours per day . If designed for continuous operation , the system is directly wired to a dedicated circuit in the electrical • Panel . Make-up air : A duct provides fresh air directly into the return air plenum of the central forced air heating system . The duct is insulated to R4 if it runs through heated space . -A motor-operated damper , located within 36 inches of the air handler , prevents air from entering the plenum when ventilation is not called for . A clock timer operates the designated whole-house exhaust fan , turns on the HVAC air.. handler , and opens the mechanical fresh air duct damper whenever ventilation is needed . Make-up air : The outdoor intake duct is equipped with a damper th:: t. i imits flow to 150 .0 CFM under normal operating conditions . Fireplace/Woodstove : Combustion air is ducted directly into the firebox . Duct has a cross sectional area of at least,' 6 square inches and a readily accessible operable damper . Doors are .i.nst i i.ed and fit tightly . All gas or oil combustion appliances ( except.. stoves and clothes dryer )- have outside combustion air ducted directly to the appliance . Al ].. stoves have an exhaust: fan directly over them . Combustion Exhaust : All combustion exhausts are separated by minimum 3 ' vertically or 10 ' horizontally . Rage 3 WATT9UN 5 .3 COMPONENT -CHECKLIST 02/18/93 F iLE : C : \WAFTDATA\LDL263 .WS HOUSE ID: LD1263 ---------------------- --- Radon monitor : Radon monitor supplied ! <: residents . Exhaust duct. :in uIation : Ali exhaust dut:;ts in unheated spaces are insulated to R4 . 1