1994, 04-14 Permit: 93008752 Energy Code Inspect SPOKANE COUNTY DEPARTMENT OF BUILDINGS
o SITE 6� 9f(e s o RESIDENTIAL ENERGY CODE INSPECTION CHECKLIST
ADDRESS �4�l [�/.�:LP......... . ................
o PERMIT C 3 -'7,-5--2
o SUB-SSB
O i> o PERIMETER INSULATION R-
<GRAVEL BASE 0 PLASTIC MEMBRANE
0
o DATE
0
o APPROVED FOR COVER BY
INSULATION CAULK
Io
o . INDOWS&DOORS PER PLANS a(WINDOWS&DOORS CAULKED .VAPOR RETARDERS:
WALL
o -• ADVANCED FRAMING: XSOLEPLATE CAULKED CEIUNG
WALLS '� ckPLUMBING//ELECTRICAL q-n IC VENT BAFFLES
o CEILINGS PENETRATIONS CAULKED
0 COMBUSTION AIR DUCTS
• WALL INSULATION: R- q SEALED DUCTWORK INSTALLED
o �• VAULTED CEIUNG: R= �EXI-IAUST FANS/DUCTS �INSTALLED
E VENTILATION
o • =ATT INSTALLATION INSTALLED ARApON FAN CIRCUIT
o TECHNIQUES 0RECESSED UGHTS
0
o 1 DATE
0
o APPROVED FOR COVER BY
O `
O IENERGY CODE FINAL
0
1(>1
- MECHANICAL SYSTEMS • WEATHERSTRIPPING PLUMBING
R HEATER PAD
O BATH EXHAUST DOORS &WINDOWS
o • KITCHEN EXHAUST 9CATTIC&CRAWL ACCESSES z,,SHOWER FLOW
• SWITCH &OUTLET COVER FIREPLACE/WOODSTOVE
EXHAUST
AUTOMATIC WHOLE HOUSE PLATES FIREPLACE DOORS
MAKE-UP AIR INTAKES ° FLUE DAMPER
• DUCTWORK INSULATION COMBUSTION AIR
EQUIPMENT INSTRUCTIONS b o FLOOR RAVI C, V�ILSPACE GROUND COVER -
•, EATING FUEL
&SYSTEM TYPE: ATTIC R- 3 -7 & t(LSPACE VENTILATION
• Ei a4,BELOW-GRADE WALLS R-15_ $\RADON VENT&LABEL
RADON MONITOR q(BATT INSTALLATION o
TECHNIQUES
• SERIAL NUMBERF__ —
._ ciwi Al APPRC)VAI BY 12 'c-0145 %i - DATE
4WTSUN 5 .3 1991 WA STATE ENERGY CGDE COMPLIANCE REPORT 02/18/93
FILE: C: \WATTDATA\LD1263 .WS HOUSE ID: LD1263
0
Site: WELLINGTON Analyst : TAS ( MARQUESS )
SPOKANE , WA Jurisdiction: SPOKANE COUNTY �
( ) - Utility : WWP
Homeowner : House Type : Single Family
Floor Area: 2649 ft2
Builder : LANCE DOUGLAS Weather Data : Spokane , WA
Climate Zone : 2
( 509 )483-6532
The PROPOSED design *COMPLIES* with 1091 WA State Energy Code .
'REFERENCE PROPOSED
COMPONENT PERFORMANCE 519 505 Btu/hr-F
ENERGY BUDGET 9 . 7'4 9 .86 kWh/ft.2-yr
REFERENCE DESIGN
Reference
Component Value X Area = UA
BG Wall. 3 .5 ' U-0 .041 553 22 .7
BG Slab 3 .5 ' F-0 .640 158ft 101 . 1
Floor U-0 .029 27 0 .0
Glazing @15 U--0 .600 397 .4 ">38 .4
Doors U-0 .400 21 .0 8 .4
AG Wall U-0 .062 1708 105 .9
Ceiling , Attic U-0 .031 1333 41 .3
Infiltration ACH-0 .350 17216ft3( 104 .2 )
Reference UA 519
PROPOSED DESIGN COMPONEN1S
Component Description Value X Area = UA
BC; Wall. RO Uninu tit:: .-d 3 . 5 ' depth U-0 .271 553 149 .9
BG Slab F--0 .511 158ft 80 .7
Floor R30 vented joist 16oc U-0 .029 27 0 .8
. 'Glazing X10% **2 glaze vinyl 3/4 " air space U-0 .480 224 .9 108 .0
*2 alz .vinyl "3/4 "air space sld 'g dr . U--0 .520 35 .0 18 .2
Items in parentheses not included in COMPONENT PERFORMANCE totals .
** Denotes non-standard values - check calculation of thermal value .
_-= = _ -_ ___ - Page 1 --•------ -_ --- --
ft.4ATTSCJN 5 .3 1991 WA STATE ENERGY CODE COMPLIANCE REPORT 02/18/93
FILE : C : \WATTDATA\LD1263 .WS HOUSE ID: LD1263
Doors **Metal Insul , w/ Raised Panel U-0 .220 21 .0 4 .6
AG Wall R19 ADV Lap Wood U-0 .055 1845 101 .5
Ceiling R38 blown Attic STD baffled U-0 .031 1333 41 .3
Infiltration Standard Air Sealing ACH-0 .350 17216ft3 ( 104 .2 )
Proposed UA 505
Struc Mass Light Frame , Sheetrock walls M- 3 .000 1333 3999
**Slap w/ no cover M-10 .000 1316 13160
HEATING/COOLING/VENTILATING SYSTEMS
PROPOSED
Heating System Type: Gas Furnace
Make: unknown/
Model : unknown/
System Efficiency: 80
Modified Efficiency : 76
Design ACH: 0 .60
Heating Load( at 66F dt ): 46283 Btu/hr
System Size : 46 .3 kBtu/hr
Maximum Size @1.50% : 69 .5 kBtu/hr
Average Annual Heat : 116 MBtu
Annual Cost : $ 649
Ventilation System: Integrated 'w/Forced
Air Furnace
Cooling System:
SEER : 0 .0 'CUYiducted )
Cooling Load( at 12F dt ): 16321 Btu/hr
Recommended Size @125% : 1 .9- tons
Annual cool requirement : **x= kWh/yr
Solar Access: Partially Shaded
PROPOSED DUCT SYSTEM
Location Avg Rvalue Surface Area
SUPPLY All in heated space
RETURN All in heated space
Page 2 -
WATTSUN 5 .3 1991 WA STATE ENERGY CODE COMPLIANCE REPORT 02/18/93
FILE: C :\WATTDATA\LD1263 .WS HOUSE ID: LD1263
GLAZING ORIENTATION
PROPOSED PROPOSED
South 1O4 .Oft2 North 155 .9ft2
Southeast : Northwest -
East • West •
Northeast. : Southwest. :
•
•
Economic and energy consumption estimates are designed for comparative
purposes only , Actual cost for heating will vary depending on weather
conditions , occupant lifestyle and other factors .
WATTSUN 5 .3 COMPONENT CHECKLIST 02/18/93
FILE : C :\WATTDATA\LD1263 .WS HOUSE ID: LD1263
Name : Floor Area : 2649 ft2
Address: WELLINGTON Heating Type : Gas Furnace
Reference : 1991 WA State Energy Code
FOUNDATION INSPECTION
Sub-slab radon requirement :
Where required , slab is poured over a. 4" thick coarse gravel.
base . A 6-mil poly soil gas retarder membrane is installed between
the gravel and slab . All tears , seams , and joints in membrane are
sealed . A radon vent pipe of at least 3" in diameter runs from
each separate gravel area to 12" above eaves .
Below grade walls :
( RO Uninsulated 3 .5 ' depth 553 .0 ft2 )
Insulation is installed from the top of the below grade wall to
the bottom of the footing . Any insulation above grade is
protected from exposure .
Slab Sealing:
All penetrations , cracks and joints in concrete slab or wallsctr
sealed with a urethane type sealant. to limit the movement of soil
gases into the indoor air .
FRAMING INSPECTION
Approved plans:
Are available onsite
•
Air leakage:
Top and bottom of mudsill and soleplate are caulked/sealed . Rim
joists between stories are caul ked/sealed .
All holes in building envelope ( i .e . exterior ceilings , walls , and
floors ) are caulked/sealed , including all electrical , plumbing ,
and HVAC penetrations .
Outlets , switch boxes and recessed fixtures on exterior walls are
caulked/sealed with approved sealant , or have foam face gaskets
installed .
Any .recessed lights are IC rated , air tight , and sealed to the
ceiling sheetrock .
Wall framing:
• Net wall area : 1845 ft2
Advanced framing with studs spaced 24" o .c . , R-10 insulated
headers and no isolated cavities which cannot be insulated
Structural panels:
All structural sheathing is stamped "Exposure I " or "Exterior " .
Windows:
- _ Page 1
WATTSUN 5 .3 COMPONENT CHECKLIST 02/18/93
FILE: C: \WATTDATA\LD1263 .WS HOUSE ID: LD1263
( 2 glaze vinyl 3/4 " air space 224 .9 ft2 )
( 2 glz .vi.n I 3/4 "a:ir" space sld 'g dr 35 .0 ft2 )
W.1. 'ii..i.:;ws are installed as shown on the approved plans . The rough
opening around windows and doors is caulked/sealed .
Exhaust tans , spot. ventilation:
Bathroom fans are 50 CFM , kitchen fans are 100 CFM . Fan ducting
has minimal bends and terminates outside of the building .
The whole house exhaust fan is between: 105 .0 and 150 .0 CFM .
INSULATION INSPECTION
Wall insulation:
( R19 ADV Lap Wood 1845 .0 ft2 )
insulation fills all exterior wall cavities . It is not compressed
and is cut to fit around wires , pipes , and outlet boxes . Recessed
fixtures in exterior walls have at least R--5 insulation behind
them .
Vapor retarder : 1 .0 perm or less vapor retarder ( e .g . poly , kraft
paper , perm rated paint ) is installed on the warm side of
insulation in floors , ceilings and walls .
•
Recessed lights:
Any recessed light fixtures in the thermal envelope are certified
under ASTM E-283 and labeled showing compliance , or are sealed
around the exterior to be air tight .
FINAL INSPECTION
Crawl space moisture barrier :
A six mil black pob'ethelene ground cover is installed on
cr awlspai. c,! floor .
.
Floor Insulation :
( R30 vented Joist 16oc 27 .0 ft2 )
insulation is supported in a permanent manner without compression .
Craw.lpace ventilation:
At least. 0 . 1 Ft2 o . net free ventilation is provided
in the vented craw.lspac;e
Pipe i nsu.I_at:.ion:
All. water pipe., in unheated spaces are insulated to R-3 .
Hot. water :
Electric water heater labeled as 'meeting ASHRAE Standard 90A-1980
or 1987 NAECA . Tank has R-10 nor--compressible pad underneath if
located over slab or in unconditioned space . Shower heads allow a
maximum flow rate ei 3 .0 gallons per minute .
-- --- - - --= = page 2 "--------
WATTSUN 5 .3 COMPONENT CHECKLIST 02/18/93
FILE : C: \WATTDATA\LD1263 .WS HOUSE ID : LD1263
Doors :
( Metal I nsu 1. , w/ Raised Panel 21 .0 ft2 )
Weatherstripping , threshhold , and doorsweep are properly adjusted
a rt ci seal wel1 .
Ceiling :
( R38 blown Attic STD baffled 1333 .0 ft2 )
Insulation is installed to the manufacturer 's recommended density
and coverage . Attic access doors are insulated and
weatherstripped .
Heating system:
unknown/ unknown
The heating system does not exceed: 69451 BTUs .
Ventilation :
The ventilation system has been checked for proper operation . If
-designed for intermittent operation , the system is controlled
automatically by a time-of-day timer set to run for a minumurn of
eight hours per day . If designed for continuous operation , the
system is directly wired to a dedicated circuit in the electrical •
Panel .
Make-up air :
A duct provides fresh air directly into the return air plenum of
the central forced air heating system . The duct is insulated to R4
if it runs through heated space . -A motor-operated damper , located
within 36 inches of the air handler , prevents air from entering
the plenum when ventilation is not called for . A clock timer
operates the designated whole-house exhaust fan , turns on the HVAC
air.. handler , and opens the mechanical fresh air duct damper
whenever ventilation is needed .
Make-up air :
The outdoor intake duct is equipped with a damper th:: t. i imits flow
to 150 .0 CFM under normal operating conditions .
Fireplace/Woodstove :
Combustion air is ducted directly into the firebox . Duct has a
cross sectional area of at least,' 6 square inches and a readily
accessible operable damper . Doors are .i.nst i i.ed and fit tightly .
All gas or oil combustion appliances ( except.. stoves and clothes
dryer )- have outside combustion air ducted directly to the
appliance . Al ].. stoves have an exhaust: fan directly over them .
Combustion Exhaust :
All combustion exhausts are separated by minimum 3 ' vertically or
10 ' horizontally .
Rage 3
WATT9UN 5 .3 COMPONENT -CHECKLIST 02/18/93
F iLE : C : \WAFTDATA\LDL263 .WS HOUSE ID: LD1263
---------------------- ---
Radon monitor :
Radon monitor supplied ! <: residents .
Exhaust duct. :in uIation :
Ali exhaust dut:;ts in unheated spaces are insulated to R4 .
1