2001, 08-07 Permit: 93008470 Energy Code Inspect SPOKANE COUNTY DEPARTMENT OF BUILDINGS
o SITE
Gj�7� ,. a 5-1761 o RESIDENTIAL ENERGY CODE INSPECTION CHECKLIST
ADDRESS
o PERMIT ?3 70
0
SUB-SLAB
olc(PERIMETER INSULATION R-j1) X GRAVEL BASE o PLASTIC MEMBRANE
0
o o APPROVED FOR COVER BY. Re'd DATE
0
0
0
o INSULATION & CAULS
o WINDOWS&DOORS PER PLANS c<VNINDOWS&DOORS CAULKED VAPOR RETARDERS:."
o I:ADVANCED FRAMING: KSOLEPLATE CAULKED CEILING
O WALLS t/ PLUMBING//ELECTRICAL �I.ATTIC VENT BAFFLES
CEILINGS PENETRATIONS CAULKED
o )a(WALL INSULATION: R-j, c,_COMBUSTION AIR DUCTS
SEALED DUCTWORK INSTALLED
o S VAULTED CEILING: R-36 9-EXHAUST FANS/DUCTS /I✓6/ RAWLSPACE VENTILATION
° ieLBATT INSTALLATION INSTALLED RADON FAN CIRCUIT
o TECHNIQUES RECESSED LIGHTS
0
o j2 DATE
0
o APPROVED FOR COVER BY
0
0
ENERGY CODE FINAL
o ECHANICAL SYSTEMS c.WEATHERSTRIPPING 4 PLUMBING
o &i BATH EXHAUST grDOORS&WINDOWS A WATER HEATER PAD
o 0 KITCHEN EXHAUST 96-ATTIC&CRAWL ACCESSES @ SHOWER FLOW
c1�AUTOMATIC WHOLE HOUSE GCCH &OUTLET COVER FIREPLACE/WOODSTOVE
PLATES
EXHAUST FIREPLACE DOORS
4MAKE-UP AIR INTAKES o FLUE DAMPER
gcDUCTWORK ,(INSULATION COMBUSTION AIR
ck EQUIPMENT INSTRUCTIONS 0 o FLOOR R-7f
I�'/ CRAWLSPACE GROUND COVER -
It-HEATING FUEL&SYSTEM TYPE: 4 ATTIC R-3Y CRAWLSPACE VENTILATION
o b SLC. kBELOW-GRADE WALLS R- / t 'RADON VENT&LABEL
4,RADON MONITOR !BATT INSTALLATION
o
TECHNIQUES
d-SERIAL NUMBER b'G q q o
`� L DATE g•-:)-/-9 o laser-.(z urp
n FINAL APPROVAL BY I 9
W.orTTSU 5 .3 1991 WA STATE ENERGY CODE COMPLIANCE REPORT 09/03/93
FILE : C : \WATTDATA\HDUG1701 .WS HOUSE ID: DOUGLAS TIMBERLANE 1
Site : S . 1701 Timberlane Analyst : TAS
Spokane , WA Jurisdiction : Spokane County
( ) - Utility: WWP
lomeowner : House Type : Single Family
Floor Area : 3038 ft2
Builder : Harley Douglas Weather Data : Spokane , WA
Climate Zone : 2
( 509 )487-9792
The PROPOSED design *COMPLIES* with 1991 WA State Energy Code .
REFERENCE PROPOSED
COMPONENT PERFORMANCE 603 580 Btu/hr-F
ENERGY BUDGET 10 .39 10 . 18 kWh;'ft2- /r
REFERENCE DESIGN
Reference
Component Value X Area = UA
BG Wall 7 ' U-0 .036 724 26 . 1
BG Slab 7 ' F-0 .554 9 5 f t 52 .6
On Grade Slab F -0 .540 86ft 46 .4
Floor U--0 .029 82 2 .4
Glazing G15% U-0 .600 455 .7 273 .4
Doors U-0 .400 40 .0 16 .0
AG Wall U-0 .062 2209 137 .0
Ceiling . Attic U-0 .031 1571 48 .7
Infiltration ACH -0 .350 2046Oft3( 123 .9 )
Reference UA 603
PROPOSED DESIGN COMPONENTS
Component Description Value X Area = UA
85 Wall RO Uninsulated 7 ' depth U-0 . 7.85 /24 13 .9
BG Slab F-0 .434 95ft 41 .2
On Grade Slab R10 4 ' vertical F-0 .480 86ft 41 ,3
Floor R30 vented Joist 16oc U-0 .029 82 2 .4
Glazing @12% **2 glaze vinyl 3/4" air space U-0 .480 324 .8 155 .9
Items in parentheses not included in COMPONENT PERFORMANCE totals .
*.*. Denotes non-standard values - check calculation of thermal value .
Page 1
L TTSUN 5 .3 1991 WA STATE ENERGY . COC!E- COMPLIANCE REPORT 09/03/93
FILE : C : \WATTDATA\HDUG1701 .W5 HOUSE ID: DOUGLAS TIMBERLANE 1
**2glaze mtl . insul w/full light U--0 .320 40 .0 12 .8
Doors Metal 1 -3/4" urethane flush U-0 . 140 19 .0 2 .7
**Metal 1-3/4 °urethane 'raised panel LJ-0 . 170 21 .0 3 .6
AG Wall R19 INT T1--11 U-0 .061 2300 , 140 .3
Ceiling **R-38 7 : 12 STD baffled U-0 .029 1365 39 .6
**R38 Scissor 7 : 12 STD baffled U-0 .030 206 6 .2
Infiltration Standard Air Sealing ACH-0 .350 20460ft3 ( 123 .9 )
Proposed UA 580
Struc Mass Light Frame , Sheetrock walls M- 3 .000 3038 9114
HEATING/COOLING/VENTILATING SYSTEMS
PROPOSED
Heating System Type : Gas Furnace
Make: unknown/
Model : unknown/
System Efficiency : 80 %
Modified Efficiency : 76
Design ACH: 0 .60
Heating Load( at 66F dt ) : 53666 Btu/hr
System Size: 53 .7 kBtu/hr
Maximum Size @150% : 80 .5 kBtu/hr
Average Annual Heat : 137 MBtu
Annual Cost : $ 768
Ventilation System: Integrated w/Forced
Air Furnace
Cooling System :
SEER : 0 .0 ( Unducted )
Cooling Load( at 12F dt ): 37086 Btu/hr
Recommended Size @125%: 4 .3 tons
Annual cool requirement : *** kWh/yr
Solar Access: Partially Shaded
PROPOSED DUCT SYSTEM
Location Avg Rvc.l.ue Surface Area
SUPPLY All in heated space
RETURN All in heated space
Page 2 ----
5 .3 1991 WA STATE ENERGY• CWE COMPLIANCE REPORT 09/03/93
FILE : C : \WATTDATA\HDUG1701 .WS HOUSE ID: DOUGLAS IIMBERLANE 1
GLAZING ORIENTATION
PROPOSED PROPOSED
South - 29 .0ft2 North : 41 .Oft.2
Sou.thea.st. : Northwest,
East : 159 .5 West : 135 .3
Northeast : Southwest
Economic and energy consumption estimates are designed for comparative
purposes only . Actual cost for heating will vary depending on weather
conditions , occupant lifestyle and other factors .
Page 3