Loading...
1994, 04-06 Permit: 93006898 Energy Code Inspect SPOKANE COUNTY DEPARTMENT OF BUILDINGS o SITE / ADDRESS 01 teyl .5Ys-113 o RESIDENTIAL ENERGY CODE INSPECTION CHECKLIST o PERMIT # l -3_ g—q q _ o SUB -SLAB ° 0 > o PERIMETER INSULATION R- GRAVEL BASE o PLASTIC MEMBRANE o i DATE 0 o APPROVED FOR COVER BY. .— 0 o o INSULATION & CAULK o A WINDOWS &DOORS PER PLANS,* WINDOWS&DOORS CAULKED o VAPOR RETARDERS: WALL o o ADVANCED FRAMING: A SOLEPLATE CAULKED CEILING o CE UNGS ! PLUMBING//ELECTRICAL leATTIC VENT BAFFLES PENETRATIONS CAULKED o razt WALL INSULATION: R- 1 GA_SEALED DUCTWORK OMALLED BUSTION AIR DUCTS p�(VAULTED CEILING: R-3 ' 'RC-EXHAUST FANS/DUCTSAiDitVENTILATION o 4 BATT INSTALLATION INSTALLED o TECHNIQUESRECESSED LIGHTS RADON FAN CIRCUIT 0 O o APPROVED FOR COVER BY / ) DATE 0 0 o ENERGY CODE FINAL o LMECHANICAL SYSTEMS k WEATHERSTRIPPING PLUMBING o eCBATH EXHAUST rat,DOORS &WINDOWS 5k WATER HEATER PAD O KITCHEN EXHAUST iik ATTIC&CRAWL ACCESSES ckSHOWER FLOW AUTOMATIC WHOLE HOUSE o SWITCH&OUTLET COVER FIREPLACE/WOODSTOVE EXHAUST PLATES FIREPLACE DOORS 6,MAKE-UP AIR INTAKES 0 FLUE DAMPER 6.DUCTWORK glANSULATION COMBUSTION AIR EQUIPMENT INSTRUCTIONS o FLOOR R- CRAWLSPACE GROUND COVER 51_1-EATING FUEL&SYSTEM TYPE: a;ATTIC R- 35 N4 b CRAWLSPACE VENTILATION o q7,4 P'/A- o BELOW-GRADE WALLS R- 0 )RADON VENT&LABEL g RADON MONITOR S;BATT INSTALLATION 0 pSERIAL NUMBER I„q 9� TECHNIQUES o FINAL APPROVAL BY 1/ (/ DATE C( 'C,.-C, it 0 INSPCHK2.0rn WATTSUN 5 .3 1991 WA STATE ENERGY CODE COMPLIANCE REPORT 02/18/93 FILE : C : \WATTDATA\LD1309 .WSHOUSE ID: LD1309 Site: DAKOTA Analyst : TAS ( MARQUESS ) SPOKANE , WA Jurisdiction: SPOKANE. COUNTY ( ) -- Utility: WWP Homeowner : House Type : Single Family Floor Area : 2668 ft2 • Builder : LANCE DOUGLAS Weather Data : Spokane , WA Climate Zone : 2 ( 509 )483-6532 The PROPOSED design *COMPLIES* with I,)91 WA State Energy Code . REFERENCE PROPOSED COMPONENT PERFORMANCE `5:' 516 C3tt /hr-F ENERGY BUDGET 9 . 75 9 .93 kWhift 2-yr REFERENCE DESIGN Reference Component Value X Area = UA BG Wall 3 .5 ' U-0 .041 308 12 .6 BG Slab 3 .5 ' F-0 .640 88ft 563 BG Wall 7 ' U-0 .036 525 18 .9 BG Slab 7 ' F-0 .551 75ft 41. .6 Floor U-0 .029 56 1 .6 Glazing (415% U-0 .600 400 .2 240 . 1 Doors U-0 .400 40 .0 16 .0 AG Wall U-0 .062 7.540 95 .5 Ceiling , Attic U-0 .031 983 30 .5 Ceiling , Vault U--O .034 370 12 .6 Infiltration AC.H-0 .350 16437ft3( 99 .5 ) Reterenee UA 526 PROPOSED DESIGN COMPONENTS Component Descript �.on Value X Area UA 8G Wall RO Uni nsu fated 3 . 5 ' depth U-0 .271 -308 83 .5 BG Slab F-0 .511 88ft 45 .0 ----------------- Items i n parentheses riot included i n COMPONENT PERFORMANCE totals . *-x Denotes non-standard values •- check calculation of thermal value . _ - _ Page 1 WATTSUN 5 .3 1991 WA STATE ENERGY CODE COMPLIANCE REPORT 02/18/93 FILE: C : \WArTDATA\LD1309 .WS HOUSE ID: LD1309 BG Wall RO Uninsulated 7 ' depth U-0 .185 525 97 .1 BG Stab F-0 .434 75ft 32 .5 Floor R30 vented Joist 16oc U--O .029 56 1 .6 Glazing @9% **2 glaze vinyl 3/4 " air space U-0 .480 181 .5 87 .1 **2 glz .viny'1 3/4 "air space sld 'g dr . U-0 .520 35 .0 18 .2 **2glaze mtl . .insul w/full light U-0 .320 19 .0 6 .1 Doors **Metal Insul , w/ Raised Panel U-0 .220 21 .0 4 .6 Metal R-5 base case U-0 .190 19 .0 3 .6 AG Wall R19 ADV Lap Wood U-0 .055 1705 93 .8 Ceiling R38 blown Attic STD baffled U-0 .031 983 30 .5 R30 batt Vault vented 2x12 24oc U-0 .033 370 12 .2 Infiltration Standard Air Sealing ACH-0 .350 16437ft3 ( 99 .5 ) Proposed UA 516 Strut: Mass Light Frame , Sheetrock walls M-- 3 .000 1353 4059 **Slab w/ no cover M-10 .000 1315 13150 HEATING/COOLING/VENTILATING SYSTEMS PROPOSED Heating System Type : Gas Furnace Make: unknown/ Model : unknown/ System Efficiency: 80 % Modified Efficiency : 76 %. Design ACH: 0 .60 Heating Load( at 66F dt ): 46414 Btu/hr System Size: 46 .4 ` kBtu/hr Maximum Size k?150% : 69 .6 kBtu/hr Average Annual Heat : 118 MBtu Annual Cost : $ 658 Ventilation System: integrated w/Forced Air F=urnace Cooling System: SEER: 0 .0 ( (inducted ) Cooling Load( at 12F dt ) : 16844 Btu/hr Recommended Size ?125% : 1 .9 tons Annual cool requirement : *** kWh/yr Solar Access : Partially Shaded _-_- Page 2 -- WATTSU 5 .3 1991 WA STATE ENERGY .CODE COMPLIANCE REPORT 02/18/93 FILE: C : \WATTDATA\LD1309 .WS HOUSE ID - LD1309 PROPOSED DUCT SYSTEM Location Avg Rvalue Surface Area SUPPLY All in heated space RETURN All in heated space GLAZING ORIENTATION PROPOSED PROPOSED South 102 .2ft2 North 113 .3ft2 - Southeast : Nor thwest . East20 .0 West - Northeast : Southwest - • • Economic and energy consumption estimates are designed for comparative purposes only . Actual cost for heating will vary depending on weather _moconditions ,_occupant lifestyle and other factors . • __-_--_====__ - . - WATT5JN 5 '3 COMPONENT CHECKLIST 02/18/93 FILE : C : \WATTDATA\LD1309 'WS HOUSE ID : LD1309 Name : Floor Area : 2668 ft2 Address: DAKOTA Heating Type: Gas Furnace Reference : 1991 WA State Energy Code -OUNDATION INSPECTION Sub-slab radon requirement : [ ] Where required , slab is poured over a 4 " thick coarse gravel base . A 6-mil poly soil gas retarder membrane is installed between the gravel and slab . All tears , Seams , and joints in membrane are sealed . A radon vent pipe of at least 3" in diameter runs from each separate gravel area to 12" above eaves . Below grade walls : ( RO Uninsulated 3 '5 ` depth 300 .0 ft2 ) ( RO UninaulaLod 7 ' depth . 525 '0 ft2 ) Insulation is installed from the top of the below grade wall to the bottom of the footing . Any insulation above grade is protected from exuoaure . Slab Sealing: All penetratinna , cracks and joints in concrete slab or walls are sealed with a urethane type sealant to limitthe movement of soil gases into the indoor air . RAMINS INSPECTION ^ Approved plans: Are available onsite Air leakage : Top and bottom of muduill and soleplate are caulked/sealed . Rim joists between stories are caulked/sealed . All holes in building envelope ( i .e . exterior ceilings , walls , and floors ) are caulked/ led , including all electrical ^ plumbing , and HVAC penetrations . Outlets , switch boxes and recessed fixtures on exterior walls are caulked/sealed with approved sealant , or have foam face gaskets installed . Any recessed lights are IC rated , air tight , and sealed to the ceiling ehoetroci . Wall framing: Net wall area : 1705 ft2 Advanced framing with studs spaced 24 " o 'o ' , R-10 insulated headers and no isolated cavities which cannot be insulated . Structural panels: All structural sheathing is stamped "Exposure I " or "Exterior " . = - -- - Page 1 - - WATTSUN 5 .3 COMPONENT CHECKLIST 02/18/93 FILE : C : \WATTDATA\LD1309 .WS HOUSE ID: LD1309 • Windows: ( 2 glaze vinyl 3/4" air space 181 .5 ft2 ) ( 2 glz .vinyl 3/4"air space :Ld 'g dr . 35 .0 ft2 ) ( 2glaze mt l . insul w/full. light 19 .0 ft2 ) Windows are installed as shown on the approved plans . The rough opening around windows and doors is caulked/sealed . Exhaust fans , spot ventilation: Bathroom fans are 50 CFM , kitchen fans are 100 CFM . Fan ducting has minimal bends and terminates outside of the building . The whole house exhaust fan is between : 100 .0 and 140 .0 CFM . INSULATION INSPECTION Wall insulation : ( R19 ADV Lap Wood 1705 .0 ft2 ) Insulation fills all exterior wall cavities . It is not compressed and is cut to fit around wires , pipes , and outlet boxes . Recessed fixtures in exterior walls have at least R' b insulation behind them . Vaulted ceiling : ( R30 batt Vault vented 2x12 24oc 370 .0 ft2 ) Insulation is LI'IStdlleci to the manufacturer recommended density and coverage without compression . Vapor retarder : 1 .0 perm or less vapor retarder ( e .g . poly , kraft paper , perm rated paint ) is installed on the warm side of insulation in 'floors , ceilings and walls . A 0 .5 perm vapor barrier is installed on all vaulted ceilings . Recessed lights : Any recessed light fixtures in the thermal envelope are certified under ASTM E-283 and labeled showing compliance , or are sealed around the exterior to be air tight . cINAL INSPECTION Crawl space moisture harrier : A six mil black polyethelene ground cover is installed on crawlspace floor . Floor Insulation : ( P30 vented Joist 16oc 56 .0 ft2 ) Insulation is supported in a permanent manner without compression . Crawlspace ventilation: • At least 0 .2 Ft2 of net free ventilation is provided in the vented crawlspace . __= _--- Page 2 ==-==== -- = - x WAT.TSUN 5 .3 COMPONENT CHECKLIST 02/18/93 FILE : C : \WATTDATA\LD1309 .WS HOUSE ID: LD1309 Pipe insulation: All water pipes in unheated spaces are insulated to IR--3 . Hot water : Electric water heater labeled as meeting ASHRAE Standard 90A--1980 or 1987 NAECA . Tank. has R--10 non-compressible pad underneath if located over slab or in unconditioned space . Shower heads allow a maximum flow rate of 3 .0 gallons per minute . Doors : ( Metal Insul , w/ Raised Panel 21 .0 ft2 ) ( Metal R-5 base case 19 .0 ft2 ) Weatherstripping , threshhold , and doorsweep are properly adjusted and seal well . Ceiling: ( R38 blown Attic STD baffled 983 .0 ft2 ) Insulation is installed to the manufacturer 's recommended density and coverage . Attic access doors are insulated and weatherstripped . Heating system: unknown/ unknown The heating system does not exceed: 69647 BTUs . Ventilation: The ventilation system has been checked for proper operation . If designed for intermittent operation , the system is controlled automatically by a time--of-day timer set to run for a minumum of eight hours per day . If designed for continuous operation , the system is directly wired to a dedicated circuit in the electrical panel . Make-up air : A duct provides fresh air directly into the return air plenum of the central forced air heating system . The duct is insulated to R4 if it runs through heated space . A motor-operated damper , located within 36 inches of the air handler , prevents air from entering the plenum when ventilation is not called for . A clock timer operates the designated whole-house exhaust fan . turn:; on the HVAC air handler , and opens the mechanical fresh ._tir duct damper whenever ventilation is needed . Make-up air : The outdoor intake duct is equipped with a damper that limits flow to 140 .0 CFM under normal operating conditions . Fireplace/Woodstove : Combustion air is ducted directly into the firebox . Duct has a cross sectional area of at least' 6 square inches and a readily ---- -_ .. _ ,__.,_ __ ..._._._ i WATTSUN 5 .3 COMPONENT CHECKLIST 02/18/93 FILE : C : \WATTDATA\LD1307 .LIHOUSE ID : LD1309 _-----____-accessible operable damper . Doors are installed and fit tightly . All gas or oil combustion appliances ( except stoves and clothes dryer ) have outside combustion air ducted directly to the appliance . All stoves have an exhaust fan directly over them . Combustion Exhaust : All combustion exhausts are separated by minimum 3 ' vertically cr 10 ' horizontally . Radon monitor : Radon monitor supplied to residents . Exhaust duct insulation: All exhaust ducts in unheated spaces are insulated to R4 .