1994, 04-06 Permit: 93006898 Energy Code Inspect SPOKANE COUNTY DEPARTMENT OF BUILDINGS
o SITE /
ADDRESS 01 teyl .5Ys-113 o RESIDENTIAL ENERGY CODE INSPECTION CHECKLIST
o PERMIT
# l -3_ g—q
q _
o SUB -SLAB
°
0 >
o PERIMETER INSULATION R-
GRAVEL BASE o PLASTIC MEMBRANE
o i DATE
0
o APPROVED FOR COVER BY. .—
0
o
o
INSULATION & CAULK
o A WINDOWS &DOORS PER PLANS,* WINDOWS&DOORS CAULKED o VAPOR RETARDERS:
WALL
o o ADVANCED FRAMING: A SOLEPLATE CAULKED CEILING
o CE UNGS ! PLUMBING//ELECTRICAL leATTIC VENT BAFFLES
PENETRATIONS CAULKED
o razt WALL INSULATION: R- 1 GA_SEALED DUCTWORK OMALLED BUSTION AIR DUCTS
p�(VAULTED CEILING: R-3 ' 'RC-EXHAUST FANS/DUCTSAiDitVENTILATION
o 4 BATT INSTALLATION INSTALLED
o TECHNIQUESRECESSED LIGHTS RADON FAN CIRCUIT
0
O o APPROVED FOR COVER BY / ) DATE
0
0
o ENERGY CODE FINAL
o LMECHANICAL SYSTEMS k WEATHERSTRIPPING PLUMBING
o eCBATH EXHAUST rat,DOORS &WINDOWS 5k WATER HEATER PAD
O KITCHEN EXHAUST iik ATTIC&CRAWL ACCESSES ckSHOWER FLOW
AUTOMATIC WHOLE HOUSE o SWITCH&OUTLET COVER FIREPLACE/WOODSTOVE
EXHAUST PLATES FIREPLACE DOORS
6,MAKE-UP AIR INTAKES 0 FLUE DAMPER
6.DUCTWORK glANSULATION COMBUSTION AIR
EQUIPMENT INSTRUCTIONS o FLOOR R- CRAWLSPACE GROUND COVER
51_1-EATING FUEL&SYSTEM TYPE: a;ATTIC R- 35 N4 b CRAWLSPACE VENTILATION
o q7,4 P'/A- o BELOW-GRADE WALLS R- 0 )RADON VENT&LABEL
g RADON MONITOR S;BATT INSTALLATION 0
pSERIAL NUMBER I„q 9�
TECHNIQUES
o FINAL APPROVAL BY 1/ (/ DATE C( 'C,.-C, it 0 INSPCHK2.0rn
WATTSUN 5 .3 1991 WA STATE ENERGY CODE COMPLIANCE REPORT 02/18/93
FILE : C : \WATTDATA\LD1309 .WSHOUSE ID: LD1309
Site: DAKOTA Analyst : TAS ( MARQUESS )
SPOKANE , WA Jurisdiction: SPOKANE. COUNTY
( ) -- Utility: WWP
Homeowner : House Type : Single Family
Floor Area : 2668 ft2
•
Builder : LANCE DOUGLAS Weather Data : Spokane , WA
Climate Zone : 2
( 509 )483-6532
The PROPOSED design *COMPLIES* with I,)91 WA State Energy Code .
REFERENCE PROPOSED
COMPONENT PERFORMANCE `5:' 516 C3tt /hr-F
ENERGY BUDGET 9 . 75 9 .93 kWhift 2-yr
REFERENCE DESIGN
Reference
Component Value X Area = UA
BG Wall 3 .5 ' U-0 .041 308 12 .6
BG Slab 3 .5 ' F-0 .640 88ft 563
BG Wall 7 ' U-0 .036 525 18 .9
BG Slab 7 ' F-0 .551 75ft 41. .6
Floor U-0 .029 56 1 .6
Glazing (415% U-0 .600 400 .2 240 . 1
Doors U-0 .400 40 .0 16 .0
AG Wall U-0 .062 7.540 95 .5
Ceiling , Attic U-0 .031 983 30 .5
Ceiling , Vault U--O .034 370 12 .6
Infiltration AC.H-0 .350 16437ft3( 99 .5 )
Reterenee UA 526
PROPOSED DESIGN COMPONENTS
Component Descript �.on Value X Area UA
8G Wall RO Uni nsu fated 3 . 5 ' depth U-0 .271 -308 83 .5
BG Slab F-0 .511 88ft 45 .0
-----------------
Items i n parentheses riot included i n COMPONENT PERFORMANCE totals .
*-x Denotes non-standard values •- check calculation of thermal value .
_ - _ Page 1
WATTSUN 5 .3 1991 WA STATE ENERGY CODE COMPLIANCE REPORT 02/18/93
FILE: C : \WArTDATA\LD1309 .WS HOUSE ID: LD1309
BG Wall RO Uninsulated 7 ' depth U-0 .185 525 97 .1
BG Stab F-0 .434 75ft 32 .5
Floor R30 vented Joist 16oc U--O .029 56 1 .6
Glazing @9% **2 glaze vinyl 3/4 " air space U-0 .480 181 .5 87 .1
**2 glz .viny'1 3/4 "air space sld 'g dr . U-0 .520 35 .0 18 .2
**2glaze mtl . .insul w/full light U-0 .320 19 .0 6 .1
Doors **Metal Insul , w/ Raised Panel U-0 .220 21 .0 4 .6
Metal R-5 base case U-0 .190 19 .0 3 .6
AG Wall R19 ADV Lap Wood U-0 .055 1705 93 .8
Ceiling R38 blown Attic STD baffled U-0 .031 983 30 .5
R30 batt Vault vented 2x12 24oc U-0 .033 370 12 .2
Infiltration Standard Air Sealing ACH-0 .350 16437ft3 ( 99 .5 )
Proposed UA 516
Strut: Mass Light Frame , Sheetrock walls M-- 3 .000 1353 4059
**Slab w/ no cover M-10 .000 1315 13150
HEATING/COOLING/VENTILATING SYSTEMS
PROPOSED
Heating System Type : Gas Furnace
Make: unknown/
Model : unknown/
System Efficiency: 80 %
Modified Efficiency : 76 %.
Design ACH: 0 .60
Heating Load( at 66F dt ): 46414 Btu/hr
System Size: 46 .4 ` kBtu/hr
Maximum Size k?150% : 69 .6 kBtu/hr
Average Annual Heat : 118 MBtu
Annual Cost : $ 658
Ventilation System: integrated w/Forced
Air F=urnace
Cooling System:
SEER: 0 .0 ( (inducted )
Cooling Load( at 12F dt ) : 16844 Btu/hr
Recommended Size ?125% : 1 .9 tons
Annual cool requirement : *** kWh/yr
Solar Access : Partially Shaded
_-_- Page 2 --
WATTSU 5 .3 1991 WA STATE ENERGY .CODE COMPLIANCE REPORT 02/18/93
FILE: C : \WATTDATA\LD1309 .WS HOUSE ID - LD1309
PROPOSED DUCT SYSTEM
Location Avg Rvalue Surface Area
SUPPLY All in heated space
RETURN All in heated space
GLAZING ORIENTATION
PROPOSED PROPOSED
South 102 .2ft2 North 113 .3ft2 -
Southeast : Nor thwest .
East20 .0 West -
Northeast : Southwest - •
•
Economic and energy consumption estimates are designed for comparative
purposes only . Actual cost for heating will vary depending on weather
_moconditions ,_occupant lifestyle and other factors .
•
__-_--_====__ - . -
WATT5JN 5 '3 COMPONENT CHECKLIST 02/18/93
FILE : C : \WATTDATA\LD1309 'WS HOUSE ID : LD1309
Name : Floor Area : 2668 ft2
Address: DAKOTA Heating Type: Gas Furnace
Reference : 1991 WA State Energy Code
-OUNDATION INSPECTION
Sub-slab radon requirement :
[ ] Where required , slab is poured over a 4 " thick coarse gravel
base . A 6-mil poly soil gas retarder membrane is installed between
the gravel and slab . All tears , Seams , and joints in membrane are
sealed . A radon vent pipe of at least 3" in diameter runs from
each separate gravel area to 12" above eaves .
Below grade walls :
( RO Uninsulated 3 '5 ` depth 300 .0 ft2 )
( RO UninaulaLod 7 ' depth . 525 '0 ft2 )
Insulation is installed from the top of the below grade wall to
the bottom of the footing . Any insulation above grade is
protected from exuoaure .
Slab Sealing:
All penetratinna , cracks and joints in concrete slab or walls are
sealed with a urethane type sealant to limitthe movement of soil
gases into the indoor air .
RAMINS INSPECTION
^ Approved plans:
Are available onsite
Air leakage :
Top and bottom of muduill and soleplate are caulked/sealed . Rim
joists between stories are caulked/sealed .
All holes in building envelope ( i .e . exterior ceilings , walls , and
floors ) are caulked/ led , including all electrical ^ plumbing ,
and HVAC penetrations .
Outlets , switch boxes and recessed fixtures on exterior walls are
caulked/sealed with approved sealant , or have foam face gaskets
installed .
Any recessed lights are IC rated , air tight , and sealed to the
ceiling ehoetroci .
Wall framing:
Net wall area : 1705 ft2
Advanced framing with studs spaced 24 " o 'o ' , R-10 insulated
headers and no isolated cavities which cannot be insulated .
Structural panels:
All structural sheathing is stamped "Exposure I " or "Exterior " .
= - -- - Page 1 - -
WATTSUN 5 .3 COMPONENT CHECKLIST 02/18/93
FILE : C : \WATTDATA\LD1309 .WS HOUSE ID: LD1309
•
Windows:
( 2 glaze vinyl 3/4" air space 181 .5 ft2 )
( 2 glz .vinyl 3/4"air space :Ld 'g dr . 35 .0 ft2 )
( 2glaze mt l . insul w/full. light 19 .0 ft2 )
Windows are installed as shown on the approved plans . The rough
opening around windows and doors is caulked/sealed .
Exhaust fans , spot ventilation:
Bathroom fans are 50 CFM , kitchen fans are 100 CFM . Fan ducting
has minimal bends and terminates outside of the building .
The whole house exhaust fan is between : 100 .0 and 140 .0 CFM .
INSULATION INSPECTION
Wall insulation :
( R19 ADV Lap Wood 1705 .0 ft2 )
Insulation fills all exterior wall cavities . It is not compressed
and is cut to fit around wires , pipes , and outlet boxes . Recessed
fixtures in exterior walls have at least R' b insulation behind
them .
Vaulted ceiling :
( R30 batt Vault vented 2x12 24oc 370 .0 ft2 )
Insulation is LI'IStdlleci
to the manufacturer recommended density
and coverage without compression .
Vapor retarder : 1 .0 perm or less vapor retarder ( e .g . poly , kraft
paper , perm rated paint ) is installed on the warm side of
insulation in 'floors , ceilings and walls .
A 0 .5 perm vapor barrier is installed on all vaulted ceilings .
Recessed lights :
Any recessed light fixtures in the thermal envelope are certified
under ASTM E-283 and labeled showing compliance , or are sealed
around the exterior to be air tight .
cINAL INSPECTION
Crawl space moisture harrier :
A six mil black polyethelene ground cover is installed on
crawlspace floor .
Floor Insulation :
( P30 vented Joist 16oc 56 .0 ft2 )
Insulation is supported in a permanent manner without compression .
Crawlspace ventilation:
• At least 0 .2 Ft2 of net free ventilation is provided
in the vented crawlspace .
__= _--- Page 2 ==-==== -- = -
x
WAT.TSUN 5 .3 COMPONENT CHECKLIST 02/18/93
FILE : C : \WATTDATA\LD1309 .WS HOUSE ID: LD1309
Pipe insulation:
All water pipes in unheated spaces are insulated to IR--3 .
Hot water :
Electric water heater labeled as meeting ASHRAE Standard 90A--1980
or 1987 NAECA . Tank. has R--10 non-compressible pad underneath if
located over slab or in unconditioned space . Shower heads allow a
maximum flow rate of 3 .0 gallons per minute .
Doors :
( Metal Insul , w/ Raised Panel 21 .0 ft2 )
( Metal R-5 base case 19 .0 ft2 )
Weatherstripping , threshhold , and doorsweep are properly adjusted
and seal well .
Ceiling:
( R38 blown Attic STD baffled 983 .0 ft2 )
Insulation is installed to the manufacturer 's recommended density
and coverage . Attic access doors are insulated and
weatherstripped .
Heating system:
unknown/ unknown
The heating system does not exceed: 69647 BTUs .
Ventilation:
The ventilation system has been checked for proper operation . If
designed for intermittent operation , the system is controlled
automatically by a time--of-day timer set to run for a minumum of
eight hours per day . If designed for continuous operation , the
system is directly wired to a dedicated circuit in the electrical
panel .
Make-up air :
A duct provides fresh air directly into the return air plenum of
the central forced air heating system . The duct is insulated to R4
if it runs through heated space . A motor-operated damper , located
within 36 inches of the air handler , prevents air from entering
the plenum when ventilation is not called for . A clock timer
operates the designated whole-house exhaust fan . turn:; on the HVAC
air handler , and opens the mechanical fresh ._tir duct damper
whenever ventilation is needed .
Make-up air :
The outdoor intake duct is equipped with a damper that limits flow
to 140 .0 CFM under normal operating conditions .
Fireplace/Woodstove :
Combustion air is ducted directly into the firebox . Duct has a
cross sectional area of at least' 6 square inches and a readily
---- -_ ..
_ ,__.,_ __ ..._._._ i
WATTSUN 5 .3 COMPONENT CHECKLIST 02/18/93
FILE : C : \WATTDATA\LD1307 .LIHOUSE ID : LD1309
_-----____-accessible operable damper . Doors are installed and fit tightly .
All gas or oil combustion appliances ( except stoves and clothes
dryer ) have outside combustion air ducted directly to the
appliance . All stoves have an exhaust fan directly over them .
Combustion Exhaust :
All combustion exhausts are separated by minimum 3 ' vertically cr
10 ' horizontally .
Radon monitor :
Radon monitor supplied to residents .
Exhaust duct insulation:
All exhaust ducts in unheated spaces are insulated to R4 .