1994, 03-09 Permit: 93006896 Energy Code Inspect SPOKANE COUNTY DEPARTMENT OF BUILDINGS
o SITE
ADDRESS /c l/14"7 —4 l 2, o RESIDENTIAL ENERGY CODE INSPECTION CHECKLIST
ADD
o PERMIT ` 3.—( '0
o SUB-SLAB
0
gt PERIMETER INSULATION R- 1 G' s..GRAVEL BASE o PLASTIC MEMBRANE
0
o DATE
0
o APPROVED FOR COVER BY. )Zeel/
0
o
o
INSULATION & CAULK
o (WINDOWS&DOORS PER PLANS j WINDOWS &DOORS CAULKED /0-VAPOR RETARDERS:
WALL L
o 1> o ADVANCED FRAMING: 'SOLEPLATE CAULKED CEIUNG
0 WALLS tPLUMBING//ELECTRICAL CEILINGS ATTIC VENT BAFFLES
p. PENETRATIONS CAULKED
0
9v-WALL INSULATION: R- 1 SEALED DUCTWORK A COMBUSTION AIR DUCTS
INSTALLED
--)
4-VAULTED CEIUNG: R- O EXHAUST FANS/DUCTS ,�; RAWLSPACE VENTILATION
o cLBATT INSTALLATION INSTALLED pcs RADON FAN CIRCUIT
o TECHNIQUES ARECESSED UGHTS
0
o o APPROVED FOR COVER BY DATE
0
0
o ENERGY CODE FINAL
o 0 MECHANICAL SYSTEMS ,WEATHERSTRIPPING 2 PLUMBING
o 4---BATH EXHAUST f DOORS &WINDOWS c WATER HEATER PAD
o 6 KITCHEN EXHAUST fel,ATTIC&CRAWL ACCESSES fkSHOWER FLOW
AUTOMATIC WHOLE HOUSE g SWITCH&OUTLET COVER FIREPLACE/WOODSTOVE
EXHAUST PLATES 14._ FIREPLACE DOORS
MAKE-UP AIR INTAKES 0 FLUE DAMPER
#*DUCTWORK or INSULATION COMBUSTION AIR
A EQUIPMENT INSTRUCTIONS o FLOOR R- q CRAWLSPACE GROUND COVER
rik HEATING FUEL&SYSTEM TYPE: &ATTIC R- 35- b CRAfW�LSPACE VENTILATION
o /,(AL
_ o BELOW-GRADE WALLS R- gRADON VENT&LABEL
RADON MONITOR OCBATT INSTALLATION o
TECHNIQUES
4 SERIAL NUMBER 6 9s-to 2
o FINAL APPROVAL BY pc(Y_elle4"/ DATE 5"9 4 e 0 INSPa,K2.0rp
•
WATTSUN 5 .3 1991 WA STATE ENERGY CODE COMPLIANCE REPORT 02/18/93
FILE: C :\WATTDATA\LD1263 .WS HOUSE ID : LD1263
Site: WELLINGTON Analyst: TAS ( MARQUESS )
SPOKANE , WA Jurisdiction: SPOKANE COUNTY
( ) -- Utility: WWP
Homeowner : House Type : Single Family
Floor Area: 2649 ft2
( 1
Builder : LANCE DOUGLAS Weather Data : Spokane , WA
Climate Zone : 2
( 509 )483-6532
The PROPOSED design *COMPLIES* with 1991 WA State Energy Code ,
REFERENCE PROPOSED
COMPONENT PERFORMANCE 5:V 505 Btu/hr-F
ENERGY BUDGET 9 . 79 9 . 36 kWh/ft2-yr
REFERENCE DESIGN
Reference
Component Value X Area = UA
BG Wall 3 .5 ' U-0 .041 553 22 .7
BG Slab 3 .5 ' F-•0 .640 158ft 101 .1
Floor U-0 .029 27 0 .8
Glazing ta15a U--0 .600 397 .4 238 .4
Doors U--0 .400 21 .0 8 .4
AG Wall U-0 .062 1708 105 .9
Ceiling , Attic U-0 .031 1333 41 .3
infiltration ACH-0 .350 17216ft3( 104 .2 )
Reference UA 519
PROPOSED DESIGN COMPONENTS
Component Description Value X Area = UA
BG Wall. RO Uninsut.at.ed 3 .5 ' depth U--0 .271 553 149 .9
BG Slab F-0 .511 158ft 80 .7
Floor R30 vented Joist 16oc U-0 .029 27 0 .8
Glazing @10% **2 glaze vinyl 3/4 " air space U--0 .480 224 .9 108 .0
**2 glz .viny] 3/4 "air space sld 'g dr . U--0 .520 35 .0 18 .2
Items in parentheses not included in COMPONENT PERFORMANCE totals .
** Denotes non-standard values - check calculation of thermal value .
Page 1 -- ----- --
P
WATTSUN 5 .3 1991 WA STATE ENERGY CODE COMPLIANCE REPORT 02/18/93
Flu: : C : \WATTDATA\LD1263 .WS HOUSE ID: LD1263
Doors **Metal Insul , w/ Raised Panel U-0 .220 21 .0 4 .6
AG Wall R19 ADV Lap Wood U-0 .055 1845 101 .5
Ceiling R38 blown Attic STD baffled U--0 .031 1333 41 .3
Infiltration Standard Air Sealing ACH-0 .350 17216ft3 ( 104 .2 )
Proposed UA 505
Struc Mass Light Frame , Sheetrock walls M- 3 .000 1333 3999
**Slab w/ no cover M-10 .000 1316 13160
HEATING/COOLING/VENTILATING SYSTEMS
PROPOSED
Heating System Type: Gas Furnace
Make: unknown/
Model : unknown/
System Efficiency : 80
Modified Efficiency: 76
Design ACH: 0 .60
Heating Load( at 66F dt ): 46283 Btu/hr
System Size: 46 .3 kBtu/hr
Maximum Size @1.50%; 69 .5 kBtu/hr
Average Annual Heat : • 116 MBtu
Annual Cost : $ 649
Ventilation System: Integrated w/Forced
Air Furnace
Cooling System :
SEER: 0 .0 ( Unducted )
Cooling Load( at 12F dt ): 1632:1 Btu/hr
Recommended Size @125%: 1 .9 tons
Annual cool requirement : *** kWh/yr
Solar Access: Partially Shaded
PROPOSED DUCT SYSTEM
Location Avg Rvalue Surface Area
SUPPLY All in heated space
RETURN All in heated space
Page 2
•
WATTSUN 5 .3 1991 WA STATE ENERGY CODE COMPLIANCE REPORT 02/18/93
FILE: C: \WATTDATA\LD1263 .WS HOUSE ID: LD1263
GLAZING ORIENTATION
PROPOSED PROPOSED
South 104 .0ft2 North 155 .9ft2
Southeast : Northwest :
East - West
Northeast. : Southwest :
Economic and energy consumption estimates are designed for comparative
purposes only . Actual cost for heating will vary depending on weather
conditions , occupant lifestyle and other factors .
WATTSUN 5 .3 COMPONENT CHECKLIST 02/18/93
•
FILE : C : \WATTDATA\LD1263 .WS HOUSE ID: LD1263
Name : Floor Area : 2649 ft2
Address: WELLINGTON Heating Type: Gas Furnace
Reference : 1991 WA State Energy Code
-OUNDATION INSPECTION
Sub-slab radon requirement :
( 1 Where required , slab is poured over a 4" thick coarse gravel
base . A 6-mil poly soil gas retarder membrane is installed between
the gravel and slab . All tears , seams, and joints in membrane are
sealed . A radon vent pipe of at least 3" in diameter runs from
each separate gravel area to 12" above eaves .
Below grade walls :
( RO Uninsulated 3 . 5 ' depth 553 .0 ft2 )
Insulation is installed from the top of the below grade wall to
the bottom of the footing . Any insulation above grade is
protected from exposure .
Slab Sealing:
All penetrations , cracks and joints in concrete slab or walls ar
sealed with a urethane type sealant to limit the movement. of soil
gases into the indoor air .
-RAMING INSPECTION
Approved plans:
Are available onsite
Air leakage I,
Top and bottom of mudsill and soleplate are caulked/sealed . Rim
joists between stories are caulked/sealed .
All holes in building envelope ( i .e . exterior ceilings , walls , and
floors ) are caulked/sealed , including all electrical , plumbing ,
and HVAC penetrations .
Outlets , switch boxes and recessed fixtures on exterior walls are
caulked/sealed with approved sealant , or have foam face gaskets
installed .
Any recessed lights are IC rated , air tight. , and sealed to the
ceiling sheetrock .
Wall framing:
Net wall area : 1845 ft2
Advanced framing with studs spaced 24" o .c . , R-10 insulated
headers and no isolated cavities which cannot be insulated .
Structural. panels :
All structural sheathing is stamped "Exposure I " or "Exterior " .
Windows :
Page 1 _. _. =- ___
WATTSUN 5 .3 COMPONENT CHECKLIST 02/18/93
FILE: C : \WATTDATA\LD1263 .WS HOUSE ID: LD1263
( 2 glaze vinyl 3/4 " air space 224 .9 ft2 )
( 2 glz .vi. rrvl 3/4"air ::space sid 'g dr 35 .0 ft2 )
W i. n. %ws are installed as shown on the approved plans . The rough
opening around windows and doors is caulked/sealed .
Exhaust tans , spot ventilation:
Bathroom fans are 50 CFM , kitchen fans are 100 CFM . Fan ducting
has minimal bends and terminates outside of the building .
The whole house exhaust fan is between: 105 .0 and 150 .0 CFM .
NSUL_ATION INSPECTION
Wall insulation :
( R19 ADV Lap Wood 1845 .0 ft2 )
Insulation fills all exterior wall cavities . It is not compressed
and is cut to fit around wires , pipes , and outlet boxes . Recessed
fixtures in exterior walls have at least P--S insulation behind
them .
Vapor retarder : 1 .0 perm or less vapor retarder ( e .g . poly , kraft
paper , perm rated paint ) is installed on the warm side of
i.nsulai ion in floors , ceilings and wall ; .
Recessed lights =
Any recessed light fixtures in the thermal envelope are certified
under ASTM E-283 and labeled showing compliance , or are sealed
around the exterior to be air tight .
INAL INSPECTION
Crawl Space moisture barrier :
A six mil black pal; ethelene ground cover is installed on
crnwlspai:'e floor .
Floor Insulation:
( R30 vented Joist l6oc 27 .0 ft2 )
Insulation is supported in a permanent manner without compression .
Crawl.apace ventilation:
At. least 0 . 1 Ft2 of net free ventilation is provided
in the vented craw.lspac .
Pipe insulation:
All water pipes in unheated spaces are insulated to R-3 .
Hot water :
Electric water heater labeled as meeting ASHRAE Standard 90A-1980
or 1987 NAECA . Tank has R-10 non-compressible pad underneath if
located over slab or in unconditioned space . Shower heads allow a
maximum flow rate el 3 .0 gallons per minute .
Page 2 _
^ ^
. . '
------
WATTSUN 5 .3 COMPONENT' CHECKLIST 02/18/93
FILE :
C : \WATTDATA\LD1263 'WS HOUSE ID : LD1263
_ _ _ --__
Doors :
( Metal lnaul . w/ Raised Panel 21 .0 ft2 )
Weathe,otriPping , threshhold , and dooraweep are Properly adjusted
and seal well .
Ceiling :
( R38 blown Attic STD baffled 1333 .0 ft2 )
Insulation is installed to the manufacturer 's recommended density
and coverage . Attic access doors are insulated and
weatherstripped .
Heating system:
unknown/ unknown
The heating system does not exceed : 69451 BTUs .
Ventilation:
The ventilation system has been checked for proper operaLiun ' If
designed for intermittent operation , the system is controlled
automatiCally by a time-of-day timer set to run for a minumum of
eight hours per day . If designed for continuous nPeratioo , the
system is directly wired to a dedicated circuit in the electrical
Panel '
Make-up air :
A duct provides fresh air directly into the return air plenum of
the central forced air heating ovatem ' The duct is insulated to R4
if it runs through heated apaoe ' A motor-operated damper , located
within 36 inches of the air handler , prevents air from entering
the plenum when ventilation is not called for . A clock timer
operates the designated whole-house exhaust fan , turns on the HVAC
air handler , and opens the mechanical fresh air duct damper
whenever ventilation is needed .
Make-up air :
The outdoor intake duct is equipped with a damper that_ Limits flow
to 150 .0 CFM under normal operating conditions .
Flreplaoe/Woodatove :
Combustion air is ducted directly into the firebox . Duct has a
cross sectional area of at least 6 square inches and a readily
accessible operable damper . Doors
are installed and fit tightly .
All gas or oil combustion appliances ( except stoves and clothes
dryer ) have outside combustion air ducted directly to the
appliance . All stoves have an exhaust fan directly over them
Combustion Exhaust :
All combustion exhausts are separated by minimum 3 ` vertically or
10 ' horizontally .
Page 3
WATTSUN 5 .3 COMPONENT CHECKLIST 02/18/93
h.l_.E : C : \WATTDATA\LD1263 .WS HOUSE ID : LD1263
Radon monitor :
Radon monitor to residents .
F_xhar_r:::;: duct.
All exhaustdui.;:s in unheated spaces are insulated to R4 . •
-- -- -