2006, 04-05 Permit App: 06001130 RemodelProject Number: 06001130 Inv: I Application Date: 4/5/2006 Page 1 of 2 THIS IS NOT A PERMIT Penalties will be assessed for commencing work without a permit Parcel Number: 55073.1936 Block: 1 Lot: 36 SiteAddress: 2011 N TSCHIRLEY RD Owner: Name: MOSKALYUK, PETER Address: 6009 VICEROY WAY Location:: CSV CITRUS HEIGHTS, CA 95610 Zoning: UR -3.5 Urban Residential 3.5 Water District: Hold: ❑ Area: 7,219 Sq Ft Width: 65 Depth: 111 Right Of Way (ft): 38 Nbr of Bldgs: 1 Nbr of Dwellings: 1 Review Information: Review Building Plan Review Originally Released: Permits: Contractor: OWNER Description Grp Type Notes BASEMENT F R-3 VB FR & SHTRK Item Description RESIDENTIAL PERMIT FEE WSBC SURCHARGE SF PLNS RVW < 7999 SQ FT 4/5/2006 By: TMELBOU Building Permit Firm: OWNER Phone: (000)000-0000 This Application: Total Project: Sq Ft Valuation SQ Ft Valuation 0 $10,000.00 0 $10,000.00 Totals: 0 $10,000.00 Units Unit Desc 1 SELECT 1 SELECT 1 SELECT 0 $10,000.00 Fee Amount $181.25 $4.50 $72.50 Permit Total Fees: $258.25 Operator: AMB Printed By: AMB Print Date: 4/5/2006 Project Number: 06001130 Inv: I Application Date: 4/5/2006 Page 2 of 2 THIS IS NOT A PERMIT Penalties will be assessed for commencing work without a permit Notes: Payment Summa Permit Type Fee Amount Invoice Amount Amount Paid Amount Owing Building Permit $258.25 $258.25 $0.00 $258.25 $258.25 $258.25 $0.00 $258.25 Disclaimer: Submittal of this application certifies the owner (or person(s) authorized by the owner) has both examined and finds the information contained within to be true and correct, and agrees that all provisions of laws and/or regulations governing this type of work will be complied with. Subsequent issuance of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the code or of any other state or local laws or ordinances. Signature: Operator: AMB Printed By: AMB Print Date: 4/5/2006 Project Number: 06001130 Inv: I Application Date: 4/3/2006 Page 1 of 1 .THIS IS NOT A PERMIT Penalties will be assessed for commencing work without a permit Parcel Number: 55073.1936 Block: 1 SiteAddress: 2011 N TSCHIRLEY RD Location:: CSV Zoning: UR -3.5 Urban Residential 3.5 Water District: Area: 7,219 Sq Ft Width: 65 Nbr of Bldgs: 1 Nbr of Dwellings: 1 Review Information: Review Building Plan Review Lot: 36 Owner: Name: MOSKALYUK, PETER Address: 6009 VICEROY WAY CITRUS HEIGHTS, CA 95610 Hold: ❑ Depth: 111 Right Of Way (ft): 38 R leased,By � rr Permits: Building Permit Contractor: OWNER Firm: OWNER Phone: (000) 000-0000 Notes: Payment Summary: Disclaimer. Submittal of this application certifies the owner (or person(s) authorized by the owner) has both examined and finds the information contained within to be true and correct, and agrees that all provisions of laws and/or regulations governing this type of work will be complied with. Subsequent issuance of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the code or of any other state or local laws or ordinances. Signature: Operator: AMB Printed By: AMB Print Date: 4/3/2006 pone �" 11707 E Sprague Ave, Suite 106 - Y�xNu l NUM�3R Valley Spokane Valley, WA 99206 PERMIT FEE: (509)688-003 y sx5(-©031 it CommnlnityDevelopment i�.cozn Residential Construction �,1, truction o Accessory Bldg Permit Applicationit-ion/Remodel o Deck 2-011 '' o Other: G SITE ADDRESS -- O t 1 A/, TL k I r ' -e N l \ a, l7 r eeo ae r eS . L414 [ 7 of/ ASSESSORS PARCEL NO E5tZ IZ I q ?(r,' T LEGAL DESCRIPTION: .Building owner Name: r h o s ct k Address: 6,00q ✓- C 2 r 0 City: e l i t 'Y e ip: Phone: J1161 2 S7'18o Fax: Name: Phone: Describe the scope of work in/ detail: r.- C, v►.�� 11 G S 4 lee � I - e) c Contractor- Name: Address: City: Zip: Phone: Fax: Lie No: Exp. Date: City Business Lie No: Cost of Project: I $ �'O' DW -0 **************The Mowing MUST be complete: write N/A if notapplicable)********************** HEIGHT TO PEAK: DIMENSIONS: # OF STORIES: TOTAL HABITABLE SPACE: MAIN FLOOR TO SQ. 2 FLOOR SQ. FTG: UNFIN BASEMENT SQ. FTG: IMPERVIOUS SURFACE FTG: AREA: FINISHED BASEMENT GARAGE SQ. FTG: DECK/COV. PATIO SQ. FTG: 30% SLOPES ON SQ. FTG: PROPERTY: # OF BEDROOMS: CONSTRUCTION TYPE: HEAT SOURCE: SEWER OR SEPTIC? The permitee verifies, acknowledges and agrees by their signature that: 1) If this permit is for construction of or on a dwelling, the dwelling istwiil be served by potable water. 2) Ownership of this City of Spokane Valley Permit inure to the property owner. 3) The signatory is the property owner or has permission to represent the property owner in this transaction. 4) All construction is to be done in full compliance with the City of Spokane Valley Development Code. Referenced codes are available for review at the City of Spokane Valley Permit Center. 5) This City of Spokane Valley Permit is not a permit or approval for any violation of federal, state or local laws, codes or ordinances. 6) Plans or additional information may be required to be submitted, and subsequently approved before this application can be processed. Signature Date 03 -3 C `"06' Method of Payment (Faxed permit applications will only be accepted with majorbankcard) ❑ Cash ❑ Check ❑ Mastercard ❑ VISA ❑ Other Bankcard #: Expires: VIN#: Authorized Signature: REMsED srzsnoos i.i 1 lF ,;OoVallley 11707 E Sprague Ave Suite 106 ♦ Spokane Valley WA 99206 509.921.10DD ♦ Fax. 509.921.1008 ♦ cityhall@spokanevaltey.org Residential Plan Submittal Minimums ❑ Completed Building & Mechanical application with: Accurate address, Parcel Number and/or Legal Description, description of work, owner and contractor infon-nation, signature, and date. ❑ Two sets of plans including Site Plan, elevations, floor plans, foundation plans With details, roof plan, framing plans & details. ❑ Show the height of any proposed buildings or accessory structures. ❑ Floor plan for each floor Dimension to scale (minimum 1/8") and label each Room (including sq. footage of house and garage on plans) Show each level of existing house and square footage of any additions. ❑ All braced wall panel types: show locations and details of installation, including engineered design. ❑ Egress windows: Provide at least one window or exterior door approved for Emergency escape or rescue from a basement and in every room for sleeping. ❑ Smoke detector locations ❑ 22" X 30" attic access location 0 18" X 24" crawl space access: ❑ One-hour separation detail: between house and garage ❑ Floor framing details: Joist type, size, spacing and installation details ❑ Roof framing plan and details ❑ Furnace and hot water heater location. ❑ All header locations: type, size, and connections ❑ Foundation plan 11 Insulation information WSEC TABLE 6-2 PRESCRIPT VE REQUIREMENTS'" FOR GROUP R OCCUP" INC . CLIMATE ZONE 2 * Reference Case Nominal R -values are for wood frame assemblies only or assemblies built in accordance with Section 601.1. I. Minimum requirements for each option listed. For example, if a proposed design has a glazing ratio to the conditioned floor area of 13%, it shall comply with all of the requirements of the 15% dazing option (or higher). Proposed designs which cannot meet the specific requirements of a listed option above may calculate compliance by Chapters 4 or 5 of this Code. 2. Requirement applies to all ceilings except: single rafter or joist vaulted ceilings. 3. Requirement applicable only to single rafter or joist vaulted ceilings. 4. Below grade walls shall be insulated either on the exterior to a minimum level of R-10, or on the interior to the same level as walls above grade. Exterior insulation installed on below grade walls shall be a water resistant material, manufactured for its intended use, and installed according to the manufacturer's specifications. See Section 602.2. 5. Floors over crawl spaces or exposed to ambient air conditions. 6. Required slab perimeter insulation shall be a water resistant material, manufactured for its intended use, and installed according to manufacturer's specifications. See Section 602.4. 7. Int; denotes standard framing 16 inches on center with headers insulated with a minimum of R-5 insulation. COOPERATIVE EXTENSION WSEC Builder's Field Guide 5th Edition WASHINGTON SrAiEUNIVERSITY �_� MENERGY PROGRAM Glazing Glazing U -Factor Door' Waliu Wall? Wall? Stab' Option Area70: U- Ceiling2 Vaulted Above Ceiling Int' Below ext'Floors on Vertical Overhead „ % of floor Factor Grade Grade Below Grade Grade I. 10% 0.40 0.58 0.20 R-38 R-30 R-21 R-21 R-12 R-30 R-10 int' ll. 15% 0.40 0.58 0.2D R-38 R-30 R-19+ R-21 R-12 R-30 R-10 R-5° Ill. 17% 0.37 0.58 0.20 R-38 R-30 R-19+ R-21 R-12 R-30 R-10 R-5° N. 25% 0.35 0.58 0.20 R-38 / R-30 / R-21 R-15 R-12 R-30 / R -10 -F Group R-1 U=0.031 U=0.034 int' / U=0.029 F=0.54 Occupancy U=0.054 Only V. Unlimited 0.35 0.58 0:20 R-38 R-30 R-21 R-21 R-12 R-30 R-10 Group R-3 inti Occupancy Only VI. Unlimited 0.32 D.58 0.20 R-38 / R-30 / R-21 R-15 R-12 R-30 / R-10 / Group R-1 U=0.031 U=0.034 int' / U=0.029 F=0.54 Occupancy U=0.054 Only * Reference Case Nominal R -values are for wood frame assemblies only or assemblies built in accordance with Section 601.1. I. Minimum requirements for each option listed. For example, if a proposed design has a glazing ratio to the conditioned floor area of 13%, it shall comply with all of the requirements of the 15% dazing option (or higher). Proposed designs which cannot meet the specific requirements of a listed option above may calculate compliance by Chapters 4 or 5 of this Code. 2. Requirement applies to all ceilings except: single rafter or joist vaulted ceilings. 3. Requirement applicable only to single rafter or joist vaulted ceilings. 4. Below grade walls shall be insulated either on the exterior to a minimum level of R-10, or on the interior to the same level as walls above grade. Exterior insulation installed on below grade walls shall be a water resistant material, manufactured for its intended use, and installed according to the manufacturer's specifications. See Section 602.2. 5. Floors over crawl spaces or exposed to ambient air conditions. 6. Required slab perimeter insulation shall be a water resistant material, manufactured for its intended use, and installed according to manufacturer's specifications. See Section 602.4. 7. Int; denotes standard framing 16 inches on center with headers insulated with a minimum of R-5 insulation. COOPERATIVE EXTENSION WSEC Builder's Field Guide 5th Edition WASHINGTON SrAiEUNIVERSITY �_� MENERGY PROGRAM EMERGENCY EGRESS REQUIREMENTS _ FROM SLEEPING ROOMS 1) NET CLEAR OPENING 5 7 SQUARE FEET GRADE FLOOR OPENING (MAX 44") 5 0 SQUARE FEET 2) NEI CLEAR OPENING HEIGHT ?4 INCHES 3) NET CLEAR OPENING WI,jTH 20 INCHES 4) MAX FINISHED SILL HEIGHT 44" ABOVE FLOOR 51 EMERGENCY ESCAPE 8 RESCUE OPENING SHALL BE OPERATIONAL FROM THE INSIDE OF THE ROOM WITHOUT fHF USE CIF K [ VS OR TOOLS SMOKE ALARMS SHALL BE INTERCON- NECTED AND HARD WIRED IN SUCH A MANNER THAT THE ACTIVATION OF ONE ALARM WILL ACTIVATE ALL ALARMS. (BEDROOMS, AREAS APPROACHING BEDROOMS, VAULTED CEILING WITH RISE OF 24" & ON EACH FLOOR) WHEN INTERIOR ALTERATIONS, REPAIRS OR ADDITIONS REQUIRING A PERMIT OCCUR, OR WHEN ONE OR MORE SLEEPING ROOMS ARE ADDED OR CREATED IN EXISTING DWELLINGS, THE DWELLING UNIT SHALL BE PROVIDED WITH SMOKE ALARMS LOCATED AS REQUIRED FOR NEW DWELLINGS. EXHAUST FANS 100 EFM kitchen 50 CFM bathrooms &.laundry ✓"ralo r, t K t om-t* " UPC 508.2 — Water heaters require anchoring or strapping at upper and lower one third points to prevent horizontal displacement during earthquakes. Strapping shall be a minimum of 4 inches above controls. WINDOW WELL: Min. 9 sq. ft. horizontal area. Min. 3 ft. horizontal projection and width. Max. 44 in. vertical depth without a ladder Muuirium width 36 in. with min. tread run of 10 in., max. rise of 7 3/4 in. & nosing of 3/4-1 '/4 in. Min. 6 ft. 8 in. headroom. Enclosed usable space under stairways requires 1 hour fire protection of/Z in. GWB HANDRAILS: Height of 34 — 38 inches when required by four or more risers shall be continuous the full length of stairs with the ends returned or rounded. LANDINGS: Required min. width of 36 in. or width of stairway and 36 in. travel distance pppppp- C 0 er W Egress windows openable 01: ILy 41 CL Q_ P �S Al v-) c, �, -, ) Egress windows,openable 5.7 sq. ft. - 44" sill J: W Egress windows openable 01: ILy 41 CL Q_ P �S Al v-) c, �, -, ) Egress windows,openable 5.7 sq. ft. - 44" sill PROVIDE DIAGRAMS AND ENGINEERING LAYOUTS FOR ROOF TRUSSES, BEAMS AND FLOOR SYSTEMS PRIOR TO FRAMING INSPECTIONS CITY COPY THIS BUILDING UBJECT CORRECTIONS TO FIELD INSPECTION REVIEI/VED EtJriC.- <.: %OMPLIANCE SPOKANE VALLEY St ILDI G DIVISION Tim