1994, 01-26 Permit: 93001324 Energy Code Inspect SPOKANE COUNTY DEPARTMENT OF BUILDINGS
o SITE - j
ADDRESS 7-7/- 1,-/, D.O./..Es" o RESIDENTIAL ENERGY CODE INSPECTION CHECKLIST
o PERMIT
F.3 -73
SUB-SLAB
• PERIMETER INSULATION R- GRAVEL BASE o PLASTIC MEMBRANE
0
o APPROVED FOR COVER BY Rte DATE
0
INSULATION & CAULK
•
o INDOWS&DOORS PER PLANS aCWINDOWS&DOORS CAULKED VAPOR RETARDERS:
o ,• •DVANCED FRAMING: SOLEPLATE CAULKED WALL
WALLS r/
,, CEILING
PLUMBING//ELECTRICAL
CEILINGS PENETRATIONS CAULKED• ATTIC VENT BAFFLES
0
WALL INSULATION: R- /9SEALED DUCTWORK 'SY�COMBUSTION AIR DUCTS
4 INSTALLED
o VAULTED CEILING: EXHAUST FANS/DUCTS
• •TT INSTALLATION INSTALLED /1N�RAWLSPACE VENTILATION
TECHNIQUES ECESSED LIGHTS OcRADON FAN CIRCUIT
° o APPROVED FOR COVER BY T4) DATE
ENERGY CODE FINAL
-
o
MECHANICAL SYSTEMS WEATHERSTRIPPING PLUMBING
• BATH EXHAUST R4'DOORS &WINDOWS WATER HEATER PAD
• KITCHEN EXHAUST i ATTIC&CRAWL ACCESSES 4 SHOWER FLOW
AUTOMATIC WHOLE HOUSE 0 SWITCH &OUTLET COVER FIREPLACE/WOODSTOVE
EXHAUST PLATES FIREPLACE DOORS
MAKE-UP AIR INTAKES o FLUE DAMPER
• DUCTWORK $INSULATION COMBUSTION AIR
• EQUIPMENT INSTRUCTIONS o FLOOR R- 3 0 CRAWLSPACE GROUND COVER
If, HEATING FUEL&SYSTEM TYPE: ceATTIC R-r3 �� g CRAWLSPACE VENTILATION
• ?1-4
o BELOW GRADE WALLS R- RADON VENT&LABEL
• RADON MONITOR kBATT INSTALLATION
TE US
SERIAL NUMBER 94(
0 FINAL APPROVAL BY__ ��_• /r DATE���- 0 INSPCHK2.DTP
•
Wt`TTSUN 5 .3 1991 WA STATE ENERGY CODE COMPLIANCE REPORT 02/18/93
FILE: C:\WATTDATA' HOUSE ID: LD211O
Site: WELLINGTON Analyst: TAS ( MARQUESS )
SPOKANE , WA Jurisdiction: SPOKANE COUNTY
( ) - Utility: WWP
Homeowner : House Type : Single Family
Floor Area: 3565 ft2
( )
Builder : LANCE DOUGLAS Weather Data : Spokane , WA
Climate Zone : '2
( 509 )483-6532
The PROPOSED design *COMPLIES* with 1991 WA State Energy Code .
REFERENCE PROPOSED
COMPONENT PERFORMANCE 644' 626 Btu/hr
ENERGY BUDGET 9 .07 9 .07 kWh/ft2-yr
REFERENCE DESIGN
Reference
Component .Value X Area tic-)
BG Wall 7 ' U-0 .036 1135 40 .9
80 Slab 7 ' F--0 .554 165ft. 91 .4
Floor U-0 .029 6( 1 .9
Glazing @15, U-0 .600 534 .8 320 .9
Doors U-0 .400 40 .0 16 .0
AG Wall U--0 .062 1962 121 .7
Ceiling , Attic U-0 .031 1128 35 .0
Ceiling , Vault U-0 .034 425 14 .5
Infiltration ACH-0 .350 19457ft3( 117 .8 )
Reference UA 642
PROPOSED DESIGN COMPONENTS
Component Description Value X Area = UA
80 Wall RO Uninsulated 7 ' depth U-0 . 185 1135 210 .0
BG Slab F-0 .434 165ft 71 .6
Floor R30 vented Joist 16oc U-0 .029 66 1 .9
Glazing @1O **2 glaze vinyl 3/4" air space U-0 .480 309 .9 148 .8
Items in parentheses not included in COMPONENT PERFORMANCE totals .
** Denotes non-standard values - check calculation of thermal value .
.--- Page 1 ----
•
W41.TSUN 5 .3 1991 WA STATE ENERGY CODE COMPLIANCE REPORT 02/18/93
FILE: C : \WATTDATA\LD2110 .WS HOUSE ID: LD211O
**2 glz .vinyl 3/4 "air space sld 'g dr . U-0 .520 35 .0 18 .2 •
Doors **Metal Insul , w/ Raised Panel U-0 .220 21 .0 4 .6 •
Metal R-5 base case U-0 .190 19 .0 3 .6
AG Wall R19 ADV Lap Wood U-0 .055. 2.152 118 .4
Ceiling R38 blown Attic STD baffled U-0 .031 1128 35 .0
R30 batt Vault vented 2x12 24oc U-0 .033 425 14 .0
Infiltration Standard Air Sealing ACH-0 .350 19457ft3 ( 117 .8 )
Proposed UA 626
Struc Mass Light Frame , Sheetrock walls M-- 3 .000 2445 7335
**Slab w/ no cover M--10 .000 1120 11200
HEATING/COOLING/VENTILATING SYSTEMS
PROPOSED
Heating System Type : Gas Furnace
Make : unknown/
Model = unknown/
System Efficiency: 80
Modified Efficiency : 76
Design ACM: 0 .60
Heating Load( at 66F dt ): 55961 Btu/hr
System Size : 56 .0 kBtu/hr
Maximum Size @150-:, : 84 .0 kBtu/hr
Average Annual Heat : 143 MBtu
Annual Cost : $ 803
Ventilation System: Integrated w/Forced
Air Furnace
Cooling System:
SEER: 0 .0 ( Unducted )
Cooling Load( at 12F dt ) : 21956 Btu/hr
Recommended Size @125%: 2 .5 tons
Annual cool requirement : *** kWh/yr
Solar Access: Partially Shaded
-----------------
PROPOSED DUCT SYSTEM
Location Avg Rvalue Surface Area
SUPPLY All in heated space
RETURN All in heated space
_ -- Page 2 -- - -
WAhTSUN 5 .3 1991 WA STATE ENERGY CODE COMPLIANCE REPORT 02/18/93
FILE: C:\WATTDATA\LD2110 .WS HOUSE ID: LD2110
GLAZING ORIENTATION
PROPOSED PROPOSED
South 168 .8ft2 North - 151 .6ft2
Southeast : Northwest :
East • 14 .0 West • 10 .5
Northeast : Southwest :
•
Economic and energy consumption estimates are designed for comparative
purposes only . Actual cost for heating will vary depending on weather
conditions , occupant lifestyle and other factors .
Page 3 ------__.._.
WATTSUN 5 .3 COMPONENT CHECKLIST 02/18/93
FILE : C : \WATTDATA\LD2110 .WS HOUSE ID: LD2110
Name : Floor Area : 3565 ft2
Address : WELLINGTON Heating Type: Gas Furnace
Reference : 1991 WA State Energy Code
FOUNDATION INSPECTION
Sub-slab radon requirement :
Where required , slab is poured over a 4" thick coarse gravel
base . A 6-mil poly soil gas retarder membrane is installed between
the gravel and slab . All tears , seams , and joints in membrane are
sealed . A radon vent pipe of at least 3" in diameter runs from
each separate gravel area to 12" above eaves .
•
Below grade walls :
( RO Uninsulated 7 ' depth 1135 .0 ft2 )
Insulation is installed from the top of the below grade wall to
the bottom of the footing . Any insulation above grade is
protected from exposure .
Slab Sealing:
All penetrations , cracks and joints in concrete slab or walls are
sealed with a urethane type sealant to limit the movement of soil
gases into the indoor air .
FRAMING INSPECTION
Approved plans :
Are available onsite
Air leakage :
Top and bottom of mudsill and soleplate are caulked/sealed . Rim
joists between stories are caulked/sealed .
All holes in building envelope ( i .e . exterior ceilings , walls , and
floors ) are caulked/sealed , including all electrical , plumbing ,
and HVAC penetrations .
Outlets , switch boxes and recessed fixtures on exterior walls are
caulked/sealed with approved sealant , or have foam face gaskets
installed .
Any recessed lights are IC rated , air tight , and sealed to the
ceiling sheetrock .
Wall framing:
Net wall area : 2152 ft2
Advanced framing with studs spaced 24" o .c . , R-10 insulated
headers and no isolated cavities which cannot be insulated .
•
Structural panels :
All structural sheathing is stamped "Exposure I " or "Exterior " .
Windows :
Page 1
WATTSUN 5 .3 ' COMPONENT CHECKLIST 0271S79TT
FILE : C:\WATTDATA\LD2110 .WS HOUSE ID : LD2110
( 2 glaze vinyl 3/4" air space 309 .9 ft2 )
(2 glz .vinyl 3/4 "air space sld 'g dr . 35 .0 ft2 )
Windows are installed as shown on the approved plans . The rough
opening around windows and doors is caulked/sealed .
Exhaust fans , spot ventilation :
Bathroom fans are 50 CFM , kitchen fans are 100 CFM . Fan ducting
has minimal bends and terminates outside of the building .
The whole house exhaust fan is between: 120 .0 and 165 .0 CFM .
INSULATION INSPECTION
Wall insulation:
( R19 ADV Lap Wood 2152 .0 ft2 )
Insulation fills all exterior wall cavities . It is not compressed
and is cut to fit around wires , pipes , and outlet boxes . Recessed
fixtures in exterior walls have at least R-5 insulation behind
them .
Vaulted ceiling :
( R30 batt Vault vented 2x12 24oc 425 .0 ft2 )
Insulation is installed to the manufacturer 's recommended density
and coverage without compression .
Vapor retarder : 1 .0 perm or less vapor retarder ( e .g . poly , kraft
paper , perm rated paint ) is installed on the warm side of
insulation in floors , ceilings and walls .
A 0 .5 perm vapor barrier is installed on all vaulted ceilings .
Recessed lights:
Any recessed light fixtures in the thermal envelope are certified
under ASTM E-283 and labeled showing compliance , or are sealed
around the exterior to be air tight .
FINAL INSPECTION
Crawl space moisture barrier : •
A six mil black polyethelene ground cover is installed on
crawlspace floor .
Floor Insulation:
( R30 vented Joist 16oc 66 .0 ft2 )
Insulation is supported in a permanent manner without compression .
Crawlspace ventilation:
At least 0 .2 Ft2 of net free ventilation is provided
• in the vented crawlspace .
Pipe insulation:
Page 2
•
WATTSUN 5 .3 COMPONENT CHECKLIST 02/18/93`
FILE : C : \WATTDATA\LD2110 .WS HOUSE ID : LD2110
All water pipes in unheated spaces are insulated to R-3 .
Hot water :
Electric water heater labeled as meeting ASHRAE Standard 90A-1980
or 1987 NAECA . Tank has R-10 non--compressible pad underneath if
located over slab or in unconditioned space . Shower heads allow a
maximum flow rate of 3 .0 gallons per minute .
Doors:
( Metal Insul , w/ Raised Panel 21 .0 ft2 )
( Metal R-5 base case 19 .0 ft2 )
Weatherstripping , threshhold , and doorsweep are properly adjusted
and seal well .
Ceiling:
( R38 blown Attic STD baffled 1128 .0 ft2 )
Insulation is installed to the manufacturer 's recommended density
and coverage . Attic access doors are insulated and
weatherstripped .
Heating system:
unknown/ unknown
The heating system does not exceed: 83971 BTUs .
Ventilation:
The ventilation system has been checked for proper operation . If
designed for intermittent operation , the system is controlled
automatically by a time-of-day timer set to run for a minumum of
eight hours per day . If designed for continuous operation , the
system is directly wired to a dedicated circuit in the electrical
panel .
Make-up air : •
A duct provides fresh air directly into the return air plenum of
the central forced air heating system . The duct is insulated to R4
if it runs through heated space . A motor-operated damper , located
within 36 inches of the air handler , prevents air from entering •
the plenum when ventilation is not called for . A clock timer
operates the designated whole-house exhaust fan , turns on the HVAC •
air handler , and opens the mechanical fresh air duct damper
whenever ventilation is needed . •
Make-up air :
The outdoor intake duct is equipped with a damper that limits flow
to 165 .0 CFM under normal operating conditions .
Fireplace/Woodstove:
Combustion air is ducted directly into the firebox . Duct has a
cross sectional area of at least 6 square inches and a readily
accessible operable damper . Doors are installed and fit tightly .
-- --- Page 3 -----_
WA.T T SUN 5 .3 COMPONENT CHECKLIST 02/18/93
FILE: C : \WATTDATA\LD2110 .W5 HOUSE ID: LD2110
All gas or oil combustion appliances ( except stoves and clothes
dryer ) have outside combustion air ducted directly to the
appliance . All stoves have an exhaust fan directly over them .
Combustion Exhaust :
All combustion exhaust s are separated by minimum 3 ' vertieally or
10 ' horizontally .
Radon monitor :
Radon monitor supplied L: esidents .
•
Exhaust duct insulation :
All exhaust ducts in unheated spaces are insulated to R4 .
•