1992, 07-29 Permit: 92000916 Energy Code Inspect Y SPOKANE COUNTY DEPARTMENT OF BUILDINGS
TE `
..,, DRESS 74! S.2,9-0. RESIDENTIAL ENERGY CODE INSPECTION CHECKLIST
o PERMIT
# F:/ — 9Y,fr
SUB—SLAB - _ _ -_
o = =___
• PERIMETER INSULATION R- (GRAVEL BASE o PLASTIC MEMBRANE
0
0
o o APPROVED FOR COVER BY A DATE
0
o F ;
--- --- - I N; U,i._t1T O & CAULK
o o WINDOWS & DOORS PER PLANS oCWINDOWS&DOORS CAULKED NVAPOR RETARDERS:
o 4 ADVANCED FRAMING: ,eS SOLEPLATE CAULKED WAS
WALLS 1/ CEILING
o 5APLUMBING//ELECTRICAL
CEILINGS PENETRATIONS CAULKED , ATTIC VENT BAFFLES
o WALL INSULATION: R- I C
SEALED DUCTWORK OMBUSTION AIR DUCTS
o INSTALLED
VAULTED CEILING: R-,50
c: EXHAUST FANS/DUCTS /Vitt RAWLSPACE VENTILATION
=ATT INSTALLATION INSTALLED
o TECHNIQUESADON FAN CIRCUIT
RECESSED LIGHTS
0
0
o o APPROVED FOR COVER BY l DATE
0
I _ -ENERGY CODE FINAL _
• MECHANICAL SYSTEMS WEATHERSTRIPPING 4'LUMBING
0
-• BATH EXHAUST ,d DOORS &WINDOWS q WATER HEATER PAD
o
r, KITCHEN EXHAUST ATTIC & CRAWL ACCESSES 54_$HOWER FLOW
• AUTOMATIC WHOLE HOUSE c(WITCH &OUTLET COVER 4 FIREPLACE/WOODSTOVE
EXHAUST PLATES FIREPLACE DOORS
C. MAKE-UP AIR INTAKES
0 a lh FLUE DAMPER
DUCTWORK INSULATION
• COMBUSTION AIR
• EQUIPMENT INSTRUCTIONS o FLOOR R-IV(4-
I.:. HEATING FUEL &SYSTEM TYPE: (ATTIC R-,::,1 "- CRAWLSPACE GROUND COVER.
. .— t
F/J �,% f BELOW- RADE WALLS R- /7CRAWLSPACE VENTILATION
9 BATT INSTALLATION
,r. RA,"DOM MoN 1-roR TECHNIQUES j� RADON VENT& LABEL
, b /`
o FINAL APPROVAL BY 17C �� 7,-29 4 ..DATE
,24
VERA WATER
AND
POWER
NORTH 601 EVERGREEN RD.
P O. BOX 630
VE RADALE WASHINGTON 99037 7530
March 24, 1992
Marty Robinson
Department of Buildings
811 North Jefferson St.
Spokane, WA 99260-0180
Dear Marty:
The dwelling structures at 15725 East 22nd Ct. and 2205 South
Timberlane listed on the attached information packet has been
reviewed by the undersigned and meets the Super Good Cents
qualification criteria for the Component Performance approach
using the WATTSUN5.2 computer program.
In order to meet the Energy Budget requirements, a heat pump
with a minimum of 6.8 H.S.P.F. rating will be required, and the
Ventilation System Specifications must be complied with.
I have sent a copy of this report to Dave Renz of T.D.C. and
instructed him that he needs to bring you copies of the plans
A.S.A.P.
Sincerely,
VERA W & P�► ' R
Michael eVleming, ►irector
Energy Management Services
Enclosure
WATTSUN 5. 2 SUPER GOOD CENTS ( 1991 MCS) COMPLIANCE REPORT 03/23/92
FILE: C:\WATTSUN5\DR/'2.9.2, WStt-4 "m1)6
HOUSE ID: DR#202
Site: 2205 SOUTH TIMBERLANE Analyst: MICHAEL DeVLEMING -'Y15
VERADALE, WA 99037 Jurisdiction: SPOKANE COUNTY
( ) - Utility: VERA WATER & POWER
Homeowner: House Type: Single Familyb/' `
Floor Area: 2628 ft2 /ti^''/
( ) i�
Builder: TDC Weather Data: Spokane, WA
Climate Zone: 2
( ) -
The PROPOSED design QUALIFIES for SGC(91 MCS) Tier 1.
REFERENCE PROPOSED
COMPONENT PERFORMANCE 448 445 Btu/hr-F
ENERGY BUDGET 4.74 5.17 kWh/ft2-yr
REFERENCE DESIGN
Reference
Component Description Value X Area = UA
BG Wall 3 . 5' R21 batt 3.5' w/TB U-0.038 532 20. 2
BG Slab 3 .5' F-0.627 152ft 95. 3
Floor R30 vented joist U-0.029 50 1.4
Glazing @15% 0 .35 U-value U-0.350 394.2 138 .0
Doors Metal R5 base case U-0.190 38.0 7. 2
AG Wall R21+R5 ADV U-0.041 1432 58 .7
Ceiling, Attic R49 blown Attic ADV U-0.020 703 14. 1
Ceiling, Vault R38 batt vault vented U-0.027 641 17.3
Infiltration Standard air sealing ACH-0.350 15864ft3 96. 1
Reference UA 448
PROPOSED DESIGN COMPONENTS
Component Description Value X Area = UA
BG Wall R21 Batt 3.5' depth U-0.038 532 20. 2
BG Slab F-0.627 152ft 95. 3
Floor R30 vented Joist 16oc U-0.029 50 1 .4
Items in parentheses not included in COMPONENT PERFORMANCE totals.
** Denotes non-standard values - check calculation of thermal value.
* Denotes adjusted UA to reflect 7-1/2 mph wind speed.
Page 1
WATTSUN 5. 2 SUPER GOOD CENTS (1991 MCS) COMPLIANCE REPORT 03/23/92
FILE: C:\WATTSUN5\DRea..WS HOUSE ID: DR#202
Glazing @10% **2-GLAZE, PATIO SLIDER/ARGON-WP U-0 .440 40.0 16.8*
**2-GLAZE, VINYL SLIDER W/ARGON-WP U-0. 360 151.0 52 . 8*
**2-GLAZE, VINYL FIXED W/ARGON-WP U-0.380 70.0 25.9*
Doors Metal R-5 base case U-0. 190 38.0 7. 2*
AG Wall R21 INT T1-il U-0.056 1095 61. 3
R21 INT Lap Wood U-0.054 470 25.4
Ceiling R38 blown Attic STD baffled U-0.031 703 21.8
**R-38 BLOWN VAULT 3.5" HEEL U-0.033 641 21. 2
Infiltration Standard Air Sealing ACH-0. 350 15864ft3 96. 1
Proposed UA 445
Struc Mass Light Frame, Sheetrock walls M- 3 . 000 1338 4014
Slab w/carpet w/pad, Sheetrock wall M- 5.000 1290 6450
HEATING/COOLING/VENTILATING SYSTEMS
PROPOSED
Heating System Type: Heat Pump: Air Source
Make: HP Air Source Default
System Efficiency: 6. 8 HSPF
Modified Efficiency: 174 %
Design ACH: 0.60
Heating Load(at 66F dt) : 35014 Btu/hr
System Size: 27.7 kBtu/hr at 47F
15. 5 kBtu/hr at 17F
Maximum Size @150%: 15. 4 kW
Auxiliary: 7.0 kW
HP Balance Point: 27 F
Average Annual Heat: 9463 kWh
Annual Cost: $ 360
Ventilation System: Integrated w/Forced
Air Furnace
Cooling Load(at 12F dt) : 30732 Btu/hr
Recommended Size @125%: 3.6 tons
Solar Access: Partially Shaded
PROPOSED DUCT SYSTEM
Location Avg Rvalue Surface Area
SUPPLY All in heated space R- 8 .0 521.6 ft2
RETURN All in heated space R- 8.0 104. 3 ft2
Page 2
WATTSUN 5. 2 SUPER GOOD CENTS (1991 MCS) COMPLIANCE REPORT 03/23/92
FILE: C:\WATTSUN5\DR#2& ..WS HOUSE ID: DR#202
GLAZING ORIENTATION
PROPOSED PROPOSED
South: ft2 North: ft2
Southeast: Northwest:
East: 108.0 West: 153 .0
Northeast: Southwest:
Economic and energy consumption estimates are designed for comparative
purposes only. Actual cost for heating will vary depending on weather
conditions, occupant lifestyle and other factors.
Page 3 -- --
Please provide the following information for Energy Code compliance: CONTINUATION OF PARCEL
sof.catoAle0 FROM Sy as-Q ,90c.v
Space heating typo (check one)
Forced air electric Electric baseboard or wall mount Propane
X Forced air gas Heat pump Other:
Flat ceilings R 38 Doors U .20
Vaulted ceilings 11 :;O Windows U .47
Above grade walls R 19 Glazing area 19 y %:_1!j,.9-
Below grade walls R 19 Total floor area
Floor R of heated space a 5 O y
Slab on grade R Furnace efficiency rating 80%
Please indicate on your plans: The location of the radon vent, and the location of the vent fan area.
Square footage
Main floor: I"a..9
Second floor:
Basement— Finished: 60�y
Unfinished: 5 8 a.
Garage: 8 B 2
•
Carport: •
Decks: et/ •
Y
;:......
Additional Areas:
• P