Loading...
2006, 01-12 Permit: 06000077 ROW • SpCITY okane BUILDING DIVISION Valley 11707 E. Sprague Avenue, Suite 106 Spokane Valley, WA 99206 Site Information Project Information Site Address: 1600 S UNIVERSITY @ 16TH AVE Project Number: 06000077 Inv: I Issue Date: 01/12/2006 Permit Use: ROAD OBSTRUCTION FOR INSTALLATION OF Parcel Number: 99999.9999 CABLE/CONDUIT/POLE Subdivision: Applicant: EMAN NETWORKS Block: Lot: 3005 30TH AVE SE Zoning: UNK Unknown PUYALLUP,WA 99216 Phone: (888)399-0297 Owner: UNKNOWN Contact: EMAN NETWORKS Address: UNKNOWN 3005 30TH AVE SE UNKNOWN PUYALLUP,WA 99216 Phone: (888)399-0297 Building Inspector: KEVIN SEVERANCE Setbacks-Front: Left: Right: Rear: Water Dist: Group Name: Project Name: Permits Right of Way Contractor: POTELCO INC License#: POTELI*227PL ROW-RD OBSTRUCTION $70.00 Total Permit Fee: $70.00 FOR RIGHT OF WAY INSPECTIONS CALL (509)869-5373 ENGINEERING IPayment Summary Total Fees AmountPaid AmountOwing Tran Date Receipt# Payment Amt $70.00 $70.00 $0.00 01/12/2006 4031 $70.00 Processed By: JANSSEN,CHRISTINA PERMIT Printed By: Main,Jodi L Page I of I NOTICE The ownership of a Spokane Valley Development Permit will inure to the property owner.The permit applicant, by definition, is the property owner or an authorized agent of the property owner. It is the responsibility of the applicant/permittee that the use described on the front of this permit complies with applicable codes and that required inspections are requested. Failure to request inspections as listed below and obtain the necessary approvals before progressing beyond the point where inspections are required may necessitate removal of certain parts of the construction at the applicant's/permittee's or property owner's expense.At a minimum,the following inspections ARE REQUIRED by City Code: FOOTING—when forms and reinforcement are in place and prior to placement of concrete-all structures,including manufactured homes. NOTE:This inspection includes review of the structure's setback from property lines.Minimum setbacks are established by City of Spokane Valley Ordinance.Curb lines and fence lines are not necessarily indicative of property lines.The responsibility to comply with applicable setback provisions lies solely with the permittee-neither the City of Spokane Valley nor its authorized representatives assume any responsibility for the verification or location of your property lines.Please verify their location prior to locating your structure.Failure to properly locate the structure may require its relocation at the owner's/permittee's expense. FOUNDATION—when forms and reinforcement are in place and prior to placement of concrete. PLUMBING—after rough-in,before covering,and final. MECHANICAL—rough-in of piping,before covering,metal chimneys before concealment,and final. FRAMING—after all framing,bracing and blocking is in place, rough electrical,plumbing and mechanical systems are complete,and prior to concealing. FINAL—when complete and prior to occupancy and/or use.All permits require final inspection. NOTE: In addition to inspection of the structure,this inspection includes review of site improvements(typically depicted on the approved site plan)required by ordinance or as a condition of approval of this permit.Items such as the installation of fire hydrants,fire department access, on-site drainage('208'swales),road improvements,parking and landscaping are common requirements of a permit/site plan which must be completed prior to final approval of a building or issuance of a Certificate of Occupancy. MANUFACTURED HOMES—Final inspection required when complete,stairs,handrails,skirting,etc.installed,and prior to occupancy; completed inspection record card must be available on site. PLUMBING REVERSALS FOR SEWER CONNECTIONS—prior to cover. RIGHT-OF-WAY/APPROACH—prior to placement of concrete/asphalt or,if gravel approach,after completion. In addition to the above,any plumbing or mechanical systems or material which would be concealed by framing,drywall,concrete,etc.must be inspected prior to cover.Check with the Building department for"special inspections"in conjunction with commercial projects. FOR INSPECTIONS Please give one working day/24 hour notice.Different parts of your project may require permits and inspections from more than one agency. Building,plumbing(includes interior reversals for sewer)and Road cuts for utilities or driveways,City of Spokane Valley mechanical,City of Spokane Valley Building Division 688-0054 Public Works 688-0195 or State Dept of Transportation 324-6000 Permits and inspections for electrical wiring,State Department of Labor Permits and inspections for Sewer Connection,Spokane County Utilities Division And Industries 324-2640 477-3604 Permits and inspections for on-site septic systems, Spokane Regional Fire sprinkler and alarm systems and private access road inspections,Spokane Valley Health Distnct 324.1560 Fire Department 692-4122 State law RCW 19.122 requires that prior to any excavation the"CALL BEFORE YOU DIG"center must be notified.Call before you dig at least 2 working days in advance,456-8000. PERMIT EXPIRATION AND REFUNDS All permits shall expire by limitation and be declared void if a)work is not started within 180 days of obtaining a permit,or b)work is abandoned for 180 days or more after beginning work,or c)after two years from the date of permit issuance,regardless of whether the work is finished. If a permit is expired for time,a new permit may be obtained for half the permit fee based on the value of the remainder of the work to finish the original permit. All refund requests must be made in writing by the original permittee to the Building Official no later than 180 days after the date of fee payment. 100%refunds will be granted for any fee erroneously paid or collected. Refunds of not more than 80%of a permit fee may be authorized when no work has been done under the permit issued.Refunds of not more than 80%of a plan review fee paid may be authorized when an application is withdrawn or cancelled prior to the plan review being completed. Owner/Agent Date ` ` ! Z— o 10 Staff Approval Date (1 MCN PM iti COCl ��C-_�-��.;C., 0.3:02 PET' :, �a�, ,,;,, ..�? �2o c��4 � , Call 24 hours before inspection required 1 Phone 509.688-0195 Fax 509.688-0037 Cion rr/7\14kw.,4 , 1)karie ley DEPARTMENT OF PUBLIC WORKS Anticipated start date /;_//3---- Pormit 1/ Account /1 Row CONSTRUCTION PERMIT Location of property Along University Rd between 22nd 8 16th (Address/Parcel It,if available) Applicant Name EMAN Networks Fax (253)845-9060 Address 3005 30th Ave SE, Puyallup,WA 98374 Phone (8681399-C297 Contractor's Name Potelco, Inc Address 13521 East Trent, Spokane, WA 99216 Pilon,-, (509) 926-6003 Contractor's Req.t/ POTEL 3--40. Expires 05/31/2007 _ PROJECT DESCRIPTION (Provide sito skoterr or plan as nnc s.sary ler cLnity) l Sewer Connection I Driveway _ Curb & Gutter Gas Installation/Rop it X Cable/Conauit/Pole Sidewalk Repair/Construction I Water Installation/Repair I I Other LiPavement Cut Dimensions Bone/insurance certification must be on file with the City.Bond q SPECIAL CONDITIONS: See attached Provisions — Perrnitteo Signature Approved Date I hereby authorize the City of Spokane Valley to cnargo the foe for this permit to my credit card. Card 4 Expiration Date t Name of Holder Sicnature poen PalcI'b ._`,.rlu Date nit _ (Application) (Inspection) In addition to the pemnit application tee cf$16.00(utility)or 525.00 (construction), inspector or each permit will be billed to the permittee at a rate of$50.00 per hour with a 525.00(1/2 Hour) minimum, Perminee signature constitutes an agreement to these terms and provisions Work completed satisfactorily (Signed) Date •Permit not valid until One-Call 1'otification Ticket rt entered here. �(O r( , O 7 t'E10t1T y11JST II 1. KEPT ON'SITtt DEC 12 2025 15:221 FADE.:�1 - — — 1 ► 1_, BUFFER DATA MINIMUM TAPER LENGTH (L) IN FELT SIGN SPACING X (FEET) IFI C7 — —.. Ni — —— -� Posted Speed (mnhl Fr CG.a s IS( n BUFFER SPACE = B y 55/70 MPH OR AS 5(4 I NJ �'� - --- -- -- -- — -- 25 30 35 40 45 50 55 60 65 70 Express,oys 4UTCD) Iv Z 58111, ( PHI 25 30 35 e0 45 50 55 60 65 0 —" — — __. __-. 0 -› 4 IC 105 150 205 265 450 500 550 - - - RurG Rorws 45/55 MPH 500• 1'-) Cl 1 LENGtH [t0011 55 85 120 uo 2210 280 135 415 4a5 565 v .- --- ,----- --- o VI PROTECTISE VEHICLE ROLL At4E AO 0151ANCE = R• ; v 11 115 155 225 295 495 550 605 060 _ - Urbon Acterlols 6 CD 35/40 NPM 350'•- ) _ tv C v - Rur EIROOd4 (Il O V1l:CLL TYPICAI VE400LE POSTED STA110NARY o 12 125 IRO 245 320 540 000 650 720 7E0 R40 n IV TYPE LOADED *UCH! SPE;PILL/ OPERATION J RuroI8000s -r Urban Streets C [LOS) Impin (teen 25/30 ►FPH 200'.- CD �, _ -_ _ _ P,esidentIals 6 CD ✓ YARD 60-70___._-100_• Y411iS Jar 8uslnees Dlstricrs 2 OWE' TRUCK 24,000 50-55 75 ,3E R£PJCEO M All slcns ore 48'x4R'block on orunpe �-- 45 50 ACCCTD.tu N 60-70 150 crit TW USE, urIIoss other,lse designoteo. C> 2 FON -c -ARCO TRUCK 15.000 50-55 100 SEE PACE 5. ru 45 15 CHANNEL DEVICE SPACING IFE3.E1) _0 fTl j 60-70 200 ---1 = 110N 10,000 50-55 60 W4-2L W20-5R MPR FAPFR TANGENT F - CARCO TRIKK 45 -_._. -- I I — - ---_-. C) _ 100 !:'''''''\ 50/70 40 HO c> -- - — — --- +7 ROLL AF+EAD STD3'PING O'SIANCE ASS(' S L42Y PAVEVENT. % W20- 1 _ 35/45 30 60 n Tut. - FtLCOur.=NDE 0,SEE TALE FOR AI PL-AT:ON PRIORITIES,PAGE C. ;i \ \ - ___ - RIGHT LANE 25/30 20 40 \ CLOSED ROAD o AHEAD/ WORK Et —' G20-2A down stream \ \ \,/ AHEAD G Et:O " or 1 o per to show end iSAIIP1.F MESSAGE) m ROAD WORK 2 48 x24' 1 / \ , g-' gip of work oren PCMS 500. SEE NOTE 6.- L X 1 X X _ 1 2 ri, MAX. RIGHT 1 " t� R II_---1 — LANE MILE L OO r — / CLOSED AHEAD -ED T- /WORK 7// ° o r *I ❑ / An 1 ° ° e ° field Io cot 3 1 Miff: <? 0 .<//, �l/ l 1_i_ °° Q _ _ __ 1n advance of lone closure. (51 411 2' MIN , / 411 c.-.3r co cl Lf— / ——13' GENERAL NOTES o — — op 1 . PROTECTIVE VEHICLE RECOMMENDED- cc> MAY BE A WORK VEHICLE. (1) -1� 2. CONTACT REGION TRAFFIC OFFICE STAFF FOR WORK HOURS. LEGEND 3. EXTEND DEVICE TAPER ACROSS SHOULDER. o `d 4. DEVICES SHOULD NOT ENCROACH INTO 7T 0 crz., a SIGN LOCATION ADJACENT LANES. CD CD ry [ {> 5E011EN 1 1 AL ARROW SIGN 5. F C�15 RECOMMENDED. -1 u 6. USE TRANSVERSE DEVICES IN CLOSED 0 0 0 TEMPORARY 1RAFF IC CONTROI DEVICESLANE EVERY 1000 4- v � � SINGLE-LANE CLOSURE 1__ I fl PROTECTIVE VEHICLE - RECOMMENDED FOR MULTI -LANE ROADWAYS 7. TRAFFIC SAFETY DRUMS RECOMMENDED TCP 2 FOR FREEWAY USE ( IN LIEU OF CONES).