Loading...
2007, 06-15 Permit App: 07002133 Remodel Project Number: 07002133 Inv: 1 Application Date: 6/15/2007 Page 1 of 2 THIS IS NOT A PERMIT Penalties will be assessed for commencing work without a permit Project Information: �. Permit Use: CONVERT GAR TO 3 BDRM/1 BTH FOR ADDT Contact: STROH CONSTRUCTION LIV SPC FOR ADULT FAM HM Address: 12920 E VALLEYWAY C-S-Z: SPOKANE VALLEY,WA 99216 Setbacks:Front Left: Right: Rear: Phone: (509)251-5502 Group Name: Site Information: Project Name: -%ai=a Cl`e.,a+WY.;,Fy;a§WiXa 3v„r, ., k'e n khY,.155, vi:^'h-.i-*xm,v,"ro.Un .:'aCv-&•x L1Mn5a%a++eBk.r ^i' w,e' 4 ,a§Nak.... "h 'd>s u.�,°b'R-::kms.Yki, e c. a a,s,pw'-a + e Plat Key: 001852 Name: OPPORTUNITY TR#01-354 District: Nort Parcel Number: 45153.2114 Block: Lot: SiteAddress: 13007 E VALLEY WAY Owner:Name: STROH,ROBERT A&AFTON L Address: 12920 E VALLEYWAY Location::CSV SPOKANE,WA 99216-0933 Zoning: UR-3.5 Urban Residential 3.5 Water District: Hold: ❑ Area: 15,360 Sq Ft Width: 0 Depth: 0 Right Of Way(ft): 50 Nbr of Bldgs: 0 Nbr of Dwellings: 1 Review Inormation: Review Building Plan Review Rleae BY - h Other Reviews Released y .. " VERIFY HOW MANY BEDROOMS ARE ADULT CARE COMPLIANT. VERIFY LEVEL OF EVACUATION OF EACH ROOM. Originally Released: 6/15/2007 By: Pchase Landuse/Zoning/HE Conditions Released B Permits: ; O_f .-TWXM, /Maf,,,,,TTMEIVEAT,z v UTWAMIAMTAINNe Operator: JD Printed By: JD Print Date: 6/15/2007 Project Number: 07002133 Inv: 1 Application Date: 6/6/2007 Page 1 of 2 THIS IS NOT A PERMIT Penalties will be assessed for commencing work without a permit Project Information: Permit Use: CONVERT GAR TO 3 BDRM/1 BTH FOR ADDT Contact: STROH CONSTRUCTION LIV SPC FOR ADULT FAM HM Address: 12920 E VALLEYWAY C-S-Z: SPOKANE VALLEY,WA 99216 Setbacks:Front Left: Right: Rear: Phone: (509)251-5502 Group Name: Project Name: Site Information: Plat Key: 001852 Name: OPPORTUNITY TR#01-354 District: Nort Parcel Number: 45153.2114 Block: Lot: SiteAddress: 13007 E VALLEY WAY Owner:Name: STROH,ROBERT A&AFTON L Address: 12920 E VALLEYWAY Location::CSV SPOKANE,WA 99216-0933 Zoning: UR-3.5 Urban Residential 3.5 Water District: Hold: ❑ Area: 15,360 Sq Ft Width: 0 Depth: 0 Right Of Way(ft): 50 Nbr of Bldgs: 0 Nbr of Dwellings: 1 Review In formation: y. _ t,rttrtea: s., wst9t swam Review Building Plan Review Released B �' Other Reviews 7,f)7 lief / ' y Released Bar ., _ (rte 1/eft�r /� U ly I rJ Ll►'lt. ✓ 1 i— �aP� C .441 � vh r i y 1.2 ve�. ae (Z J0.C ;.�.�'t't Landuse/Zoning/HE Conditions Released By Operator: JD Printed By: JD Print Date: 6/6/2007 '}2 Permit Center crrr of�T� 11703 E Sprague Ave, Suite B-3 PERMIT NUMBER: Spokane Spokane Valley,WA 99206 . 40,Valley PERMIT FEE: (509)688-0036 FAX: (509)688 0037 wv r stagkanev RIIe}��i gli },i( !t 1 Community Development ' Residential Construction JU ;,z 0076_eliNew Construction Accessory Bldg Permit Application y 3,) Ai [ ddition/Remodel fl Deck D) tui i, ; i Iki they: SITE ADDRESS: / v7 (- - V ASSESSORS PARCEL NO: LEGAL DESCRIPTION:Df norR/ 'ftii '&Dki 'sS s'ag pr -rec. i/-:z s jut 12v W/od ` CF/ 9Z 9 Building Owner: Contractor: f�6 gr, 4nycW CoNs- rc�.ct;c�ry Name: �p 6,L v t Name: \3i\cio t\I S\r oh Address: i77zA46,44.4„(1 Address:uq �, Va,ileywa.y Aye City:ive.v 4i4f4 State:tor Zip:9w5- City: stookou,le Valley Slate:(Ai A Zip gg2i(O Phone:' 8Z y...,f Z v 7 Fax: 564 Z z 4.--Z v 7 3 Phone: , 2 B i • s502 Fax: so,. 712 '3c,,Cf(0 Contractor LicNo. 1 Rd HC'cbc)-0 Date: 3 I a W1 aoo q Contact Person City Business Lic.No: U (06r)._. OD6`� SCI Name: ye 6 ev'-..c Ler 4 \ Phone: c—a i—/Z99 Describe the scope of work in detail: Cost of Project: $ ze ®� 1"H / _ lig-- i -e-1,_�..--- I / b . v,.;4si t_._, ` '•ei lam—Gl&1. ' Proposed Use: ,1,;. a /`,,,,TI ���/�fa- ..Z, l . **************The following MUST be complete: (write N/A if not applicable)********************** HEIGHT TO PEAK: DIMENS ONS: #OF STORIES: TOTAL HABITABLE SPACE: rY(3Lt €th1y / g, b cc ? z- MAIN FLOO)O SQ. 2"" FLOOD(SQ. FTG: UNFIN BASEMENT SQ. FTG: IMPERVIOUS SURFACE FTG: AREA: -1 6'_3 2- /t//4 /i ARA Q. FTG: DEC OV. PATIO SQ. FTG: 30% SLOPES ON FINISHED BA MENT G G� SQ. FTG: #1 A/ /(/4 PROPERTY: N/if #OF BEDRO MS: CONSTRUCTION TYPE: HEA SO�URCE: SEWER OR SEPTIC? The permitee verifies,acknowledges and agrees by their signature that: 1) If this permit is for construction of or on a dwelling,the dwelling is/will be served by potable water. 2) Ownership of this City of Spokane Valley Permit inure to the property owner. 3) The signatory is the property owner or has permission to represent the property owner in this transaction. 4) All construction is to be done in full compliance with the City of Spokane Valley Development Code. Referenced codes are available for review at the City of Spokane Valley Permit Center. 5) This City of Spokane Valley Permit is not a permit or approval for any violation of federal,state or local laws,codes or ordinances.6) Plans or additional information may be required to be submitted, and subsequently approved before this application can be processed. SIGNATURE: DATE: 6/07 Method of Payment: ❑ Cash ❑ Check 0 Mastercard 0 VISA Bankcard#: Expires: VIN#: Authorized Signature: REVISED 2/15/07 S ` pokane Valley® 11703 E Sprague Ave Suite B-3 ♦ Spokane Valley WA 99206 509.688.0036 ♦ Fax: 509.688.0037 ♦ cityhall@spokanevalley.org Residential Plan Submittal Minimums ❑ Completed Building & Mechanical application with: Accurate address, Parcel Number and/or Legal Description, description of work, owner and contractor information, signature, and date. Er Two sets of plans including Site Plan, elevations, floor plans, foundation plans With details, roof plan, framing plans & details. EtV Show the height of any proposed buildings or accessory structures. Er Floor plan for each floor: Dimension to scale (minimum 1/8") and label each Room (including sq. footage of house and garage on plans) Show each level of existing house and square footage of any additions. C' All braced wall panel types: show locations and details of installation, including engineered design. 2" Egress windows: Provide at least one window or exterior door approved for Emergency escape or rescue from a basement and in every room for sleeping. d Smoke detector locations Err 22" X 30" attic access location Er" 18" X 24" crawl space access: C" One-hour separation detail: between house and garage 0" Floor framing details: Joist type, size, spacing and installation details Ems] Roof framing plan and details 4// d Furnace and hot water heater location. 04 CI All header locations: type, size, and connections El/ Foundation plan V Insulation information WASHINGTON STATE AMENDMENTS SECTION R324 ADULT FAMILY HOMES Basements located more than 4 feet below grade level shall not be used for family child day care homes unless one of R324.1 General. This section shall apply to all newly constructed adult family homes and all existing single following conditions exist: family homes being converted to adult family homes. This 1. Stairways from the basement open directly to the section shall not apply to those adult family homes licensed exterior of the building without entering the first by the State of Washington Department of Social and floor;or Health Services prior to July 1,2001. 2. One of the two required means of egress discharges R324.2 Submittal standards. In addition to those directly to the exterior from the basement level,and a requirements in Section 106.1,the submittal shall identify self closing door is installed at the top or bottom of the project as a Group R,Division 3 Adult Family Home the interior stair leading to the floor above;or Occupancy. A floor plan shall be submitted identifying the 3. One of the two required means of egress is an means of egress and the components in the means of egress operable window or door,approved for emergency such as stairs,ramps,platform lifts and elevators.The plans escape or rescue,that opens directly to a public street, shall indicate the rooms used for clients and the sleeping public alley,yard or exit court;or room classification of each room. 4. A residential sprinkler system is provided throughout R324.3 Sleeping room classification.Each sleeping room the entire building in accordance with National Fire in an adult family home shall be classified as: Protection Association Standard 13D. Floors located more than 4 feet above grade level shall 1.Type S-where the means of egress contains stairs, elevators or platform lifts. not be occupied by children in family day care homes. Exceptions: 2.Type NSI -where one means of egress is at grade 1. Use of toilet facilities while under supervision of an level or a ramp constructed in accordance with R311.6 is provided. adult staff person. 2. Family child day care homes may be allowed on the 3.Type NS2-where two means of egress are at grade second story if one of the following conditions exists: level or ramps constructed in accordance with 2.1 Stairways from the second story open directly to R311.6 are provided. the exterior of the building without entering the R324.4 Types of locking devices. All bedroom and first floor;or bathroom doors shall be openable from the outside when 2.2 One of the two required means of egress locked. discharges directly to the exterior from the second Every closet shall be readily openable from the inside. story level,and a self closing door is installed at the top or bottom of the interior stair leading to R324.5 Smoke alarm requirements. All adult family the floor below;or homes shall be equipped with smoke alarms installed as 2.3 A residential sprinkler system is provided required in Section R313. Alarms shall be installed in such throughout the entire building in accordance with a manner so that the fire warning may be audible in all parts National Fire Protection Association Standard of the dwelling uponactivation of a single device. 13D. R324.6 Escape windows and doors. Every sleeping room Every sleeping or napping room in a family child day shall be provided with emergency escape and rescue care home shall have at least one operable window for windows as required by Section R310. emergency rescue. Exception: Sleeping or napping rooms having doors leading R324.7 Fire apparatus access roads and water supply to two separate means of egress,or a door leading directly to i for fire protection. Adult family homes shall be served by the exterior of the building. fire apparatus access roads and water supplies meeting the Rooms or spaces containing a commercial-type cooking requirements of the local jurisdiction. kitchen,boiler,maintenance shop,janitor closet,laundry, woodworking shop,flammable or combustible storage,or SECTION R325 painting operation shall be separated from the family child FAMILY,CHILD DAY CARE HOMES day care area by at least one-hour fire-resistive .• construction. R325 Family child day care homes. For family child day Exception: A fire-resistive separation shall not be required care homes with more than six children,each floor level where the food preparation kitchen contains only a domestic used for family child day care purposes shall be served by cooking range,and the preparation of food does not result in two remote means of egress. Exterior exit doors shall be the production of smoke or grease laden vapors. operable from the inside without the use of keys or any special knowledge or effort. (Insert Facing Page 60) Effective 7/01/04 WASHINGTON STATE AMENDMENTS R311.6.3.3 Continuity.Handrails where required on ramps shall be continuous for the full length of the ramp.Handrail ends shall be returned or shall terminate in newel posts or safety terminals.Handrails adjacent to a wall shall have a space of not less than 1.5 inches(38 mm)between the wall and the handrails.At least one handrail shall extend in the direction of ramp run not less than 12 inches(305 mm) horizontally beyond the top and bottom of the ramp runs. ADULT FAMILY HOME means a dwelling in which a person or persons provide personal care,special care,room and board to more than one but not more than six adults who are not related by blood or marriage to the person or persons providing the services. • (Insert Facing Page 9) Effective 7/01/04 BUILDING PLANNING R311.5.6.3 Handrail grip size. All required handrails R311.6.3 Handrails required.Handrails shall be provided shall be of one of the following types or provide equiva- on at least one side of all ramps exceeding a slope of one unit lent graspability. vertical in 12 units horizontal(8.33-percent slope). 1. Type I.Handrails with a circular cross section shall R311.6.3.1 Height.Handrail height,measured above the have an outside diameter of at least 11/4 inches(32 finished surface of the ramp slope,shall be not less than mm)and not greater than 2 inches(51 mm).If the 34 inches (864 mm) and not more than 38 inches (965 handrail is not circular it shall have a perimeter di- mm). mension of at least 4 inches (102 mm) and not R311.6.3.2 Handrail grip size. Handrails on ramps greater than 61/4 inches(160 mm)with a maximum shall comply with Section R311.5.6.3. cross section of dimension of 21/4 inches(57 mm). R311.6.3.3 Continuity. Handrails where required on 2. Type II.Handrails with a perimeter greater than 6'/4 ramps shall be continuous for the full length of the ramp. inches(160 mm)shall provide a graspable finger re Handrail ends shall be returned or shall terminate in cess area on both sides of the profile.The finger re newel posts or safety terminals. Handrails adjacent to a cess shall begin within a distance of 3/4 inch(19 mm) wall shall have a space of not less than 1.5 inches (38 measured vertically from the tallest portion of themmbetween the wall and the handrails. profile and achieve a depth of at least 5/16 inch (8 mm)within 78 inch(22 mm)below the widest por- tion of the profile. This required depth shall con SECTION R312 tinue for at least 3/8 inch(10 mm)to a level that is not GUARDS less than 13/4 inches(45 mm)below the tallest por- tion of the profile.The minimum width of the hand- R312.1 Guards required.Porches, balconies or raised floor rail above the recess shall be 1'/4 inches(32 mm)to a surfaces located more than 30 inches(762 mm)above the floor maximum of 23/4 inches(70 mm).Edges shall have or grade below shall have guards not less than 36 inches(914 a minimum radius of 0.01 inches(0.25 mm). mm)in height.Open sides of stairs with a total rise of more than R311.5.7 Illumination.All stairs shall be provided with it 30 inches(762 mm)above the floor or grade below shall have lumination in accordance with Section R303.6. guards not less than 34 inches (864 mm) in height measured vertically from the nosing of the treads. R311.5.8 Special stairways. Circular stairways, spiral Porches and decks which are enclosed with insect screening stairways, winders and bulkhead enclosure stairways shall shall be provided with guards where the walking surface is lo- comply with all requirements of Section R311.5 except as cated more than 30 inches(762 mm)above the floor or grade specified below. below. R311.5.8.1 Spiral stairways. Spiral stairways are per R312.2 Guard opening limitations.Required guards on open mitted,provided the minimum width shall be 26 inches sides of stairways, raised floor areas, balconies and porches (660 mm)with each tread having a 71/2-inches(190 mm) shall have intermediate rails or ornamental closures which do minimum tread depth at 12 inches from the narrower not allow passage of a sphere 4 inches(102mm)or more in di- edge.All treads shall be identical,and the rise shall be no ameter. more than 91/2 inches(241 mm).A minimum headroom of 6 feet 6 inches(1982 mm)shall be provided. Exceptions: R311.5.8.2 Bulkhead enclosure stairways. Stairways 1. The triangular openings formed by the riser,tread and serving bulkhead enclosures, not part of the required bottom rail of a guard at the open side of a stairway are building egress,providing access from the outside grade permitted to be of such a size that a sphere 6 inches level to the basement shall be exempt from the require- (152 mm)cannot pass through. ments of Sections R311.4.3 and R311.5 where the maxi- 2. Openings for required guards on the sides of stair mum height from the basement finished floor level to treads shall not allow a sphere 4 3/B inches(107 mm)to grade adjacent to the stairway does not exceed 8 feet pass through. (2438 mm),and the grade level opening to the stairway is covered by a bulkhead enclosure with hinged doors or other approved means. SECTION R313 R311.6 Ramps. SMOKE ALARMS R311.6.1 Maximum slope.Ramps shall have a maximum [F]R313.1 Smoke alarms.Smoke alarms shall be installed in slope of one unit vertical in eight units horizontal(12.5-per the following locations: cent slope). 1. In each sleeping room. R311.6.2 Landings required. A minimum 3-foot-by-3-foot 2. Outside each separate sleeping area in the immediate vi- (914 mm by 914 mm)landing shall be provided: cinity of the bedrooms. 1.At the top and bottom of ramps, 3. On each additional story of the dwelling,including base- ments but not including crawl spaces and uninhabitable 2.Where doors open onto ramps, attics.In dwellings or dwelling units with split levels and 3.Where ramps change direction. without an intervening door between the adjacent levels, 2003 INTERNATIONAL RESIDENTIAL CODE® 51 :Srto3m1A1U0.114??"4R0 3 Y7N3i1F 301 eMOOR S►P1i�?13Jt mow- T 333 . .. 7333 F;F, h xAtti aoliti, THai#t i t4TOiW i1 Jo,a 31u k. I-Wt3H WSEC TABLE 6-2 ',Ms': PRESCRIPTIVE REQUIREMENTS°" FOR GROUP R OCCUPANCY CLIMATE ZONE 2 • Glazi •` GleEing U Fadtdp''r ''1F? 12 Wall? Wall? e Option Area ' ?Ni. iyk;t 31141 fit: fil TIM 2 Vaulted Wall int° ext4 Slab on °!o of floor �''`3" '~'�'l `f1A 18A ? .- [llP. eiling Ceiling3 Grade Below Below Floors Grade Vertical, Overhead"J ►+. •R'11"' Grade Grade I. 10% 0.40 0.58 0.20.-1.• R-38 R-30 R-21 R-21 R-12 R-30 R-10 int' II. 15% 0.40 0.58 0.20 R-38 R-30 R-19+ R-21 R-12 R-30 R-10 R-58 n a': Ill. ;1 y A7p/o 0.37 `0.58 0.20 R-38 R-30 R-19+ R-21 R-12 R-30 R-10 A R-58 4 e IV. 25% 0.35 0.58 0.20 R-38/ R-30/ R-21 R-15 R-12 R-30/ R-10/ Group R-1 U=0.031 U=0.034 int'/ U=0.029 F=0.54 Occupancy U=0.054 Only V. Unlimited 0.35 0.58 0.2d k-3 R-30 R-21 R-21 R-12 R-30 R-10 Group R-3 ;i# int' Occupancy t i, Only VI. Unlimited 0.32 0.58 0.20 R-38/ R-30/ R-21 R-15 R-12 R-30/ R-10/ Group R-1 U=0.031 U=0.034 int'/ U=0.029 F=0.54 Occupancy U=0.054 Only * Reference Case 1i01/°,talwq ft ILO 0. Nominal R-values are for wood frame assemblies only or assemblies built in accordance with Section 601.1. 1. Minimum requirements for each option listed. For example, if a proposed design has a glazing ratio to the conditioned floor area of 13%,it shall comply with all of the requirements of the 15% glazing option(or higher). Proposed designs which cannot meet the specific requirements of a listed option above may,b'alculate.tompliance by Chapters 4 or 5 of this Code. 2. Requirement applies to all ceilings except single rafter or joist vaulted ceilings. 3. Requirementltpronly to single rafter or joist vaulted ceilings. 4. Below gradp,ws,5liall,be insulated either on the exterior to a minimum level of R-10, or on the interior to the same level as walls above grade. Exterior insulation installed on below grade walls shall be a water resistant material,manufactured for its intended use,and installed according to the manufacturer's specifications. See Section 602.2. 5. Floors over crawl spaces or exposed to ambient air conditions. 6. Required slab perimeter insulation shall be a water resistant material,manufactured for its intended use, and installed according to manufacturer's specifications. See Section 602.4. 7. Int. denotes standard framing 16 inches on center with headers insulated with a minimum of R-5 insulation. COOPERATIVE EXTENSION WSEC Builder's Field Guide 5th Edition WASHINGTON STATE UNIVERSITY 1-7 ENERGY PROGRAM EMERGENCY EGRESS REQUIREMENTS FROM SLEEPING ROOMS 1)NET CLEAR OPENING: 5.7 SQUARE FEET GRE 0001;O (MAX 44•) 5A SQUARE FEET 2)NET CLEAR ENING HEIGHT 24 INCHES 3►NET ADCLEAR FLOOR ENIGPENING WIDTH 20 INCHES 4)MAX;IF 4E0 Slll HEIGHT 44•ABOVE FLOOR 51 EME RGE NCY E SCAPE 8 RESCUE OPENING SHAL4 8E uPERAIV N�.L FROM THE INSIDE OF THE ROOM WITHOUT 94f USE Of 10 YS OR TOOLS WHEN INTERIOR ALTERATIONS,REPAIRS OR ADDITIONS REQUIRING A PERMIT OCCUR,OR WHEN ONE OR MORE SLEEPING ROOMS ARE ADDED OR CREATED IN EXISTING DWELLINGS.THE DWELLING UNIT SHALL BE PROVIDED WITH SMOKE ALARMS LOCATED AS REQUIRED FOR NEW DWELLINGS. ® SMOKE ALARMS SHALL BE INTERCON- NECTED AND HARD WIRED IN SUCH A MANNER THAT THE ACTIVATION OF ONE ALARM WILL ACTIVATE ALL ALARMS. (BEDROOMS, AREAS APPROACHING BEDROOMS . VAULTED CEILING WITH RISE OF 24'& ON EACH FLOOR) )(V UStUFANS kitchen 50CVM bathroom &iandry V ev-r.o -1-E 02. 10# felt for ice dam protection i o 2�`iNSiC E=kz�12cv A_.a,ALL— BLOCKING UNDER ALL COLUMNS BLAnING WALLS AND SHEAR WALLS. PROVIDE DOUBLE JOINTS(MIN)UNDER ALL WALLS PARALLEL TO SPAN U.N.O. PROVIDE DOUBLE STUDS(MIN)TO FOUNDATION UNDER ALL HIP AND GIRDER TRUSSES U.N.O. PROVIDE SHEAR CONNECTION FROM INTERIOR A WALLS TO TRUSSES OR JOISTS ABOVE. Apr 23 07 01 : 42p QC Manager 801 825-5903 p. 1 -nlorr_:': ire.:-r7 ' ' r-r ,LL rit-s11t� ioN S 0 'SE.C. -')N ' F ' ,/.". 'rit-=•G-r' E0511ti161 -A 7 y f tc__4L A{ ::)�2. C2,-.) ---s•-.4c3 Egt s windows openable :r - ; ' •, ' ! 0 5.7 ft. - 44" sill i-1 -,A i4 --- f.oast [. �.�-1-c �' `! 0 . - �I to . 1. --_-tt.4, NJ' 4,0.1- �! �, 1 24—r-241) I 2i-0IIi. - -rf `N , : I 'NI"\/;1' .__,_m A • • ---4. ' 4 f3e9 naoM N: IrN r _.may! 1 rte) -r , 11 Egress wi ' owls:'. nal l• . . 05.7sq. ft.. 1,: sill ill y __.... 2.t`-8/z. / . .._...__. . .3t . 1.,-.44.! : ..:1, ...1:-...A24. i ,/,;! ________L-=-..._. lci, Min. 4 ft Brace Wall Panel per R602.10.3 & R602.10.4 Min. 2 ft 8 in. Alternate Brace Wall Panel per R602.10.6 Min. 16, 18 or 20 in. APA Portal Frame Bracing Engineered Shear Wall Bracing - Apr 23 07 01 : 42p QC Manager 801 825-5903 p. 2 r . 1 Zxcv L G`t:::: 1( X:Vo : . "-$ GSR 'V X N I / -2: ..4 - I — - --- — I JNA _ N 4........ _______..... .. . . .Zni KIM /-*': . (-zxci„ LEpclrqz, • r ....L..... .... ..., , :1,.. i ! .. i ...e- a-F4.X)r2, rf2l�t�i Ni 6 P'L4\1\1. -icr 1 .S46L6: 1/40 11 -d' 4 flpr 22 n7 n1 : 42o OG Manager 801 825-5903 p. 3 N1101.3.1 —Attic insulation certification required as to CEILING: %2" GWB if perpendicular to rafters or R-value or coverage. Markers, attached to trusses or trusses 24"o.c. and no water based texture used— ' rafters, required for every 300 sf of attic space with 1 otherwise 5/8" GWB. inch high numbers for installed thickness of insulation. Attic Accessible Attic Ventilation X 30" 1 Sq Ft per every 300 Sq Ft of space by 22' ventilated with at least 50%in the upper portion of roof area. R 3 w/ t" At 0_ C.4 A-ii "r- Nsu` ±-t-r0 ti T e y or /'� rpt 1i4ei- 6.4 t .1 j 1 -1)(4_II cl -1)(4_-1)(4_ wALLL ra Ds fuer) • ) .,. ��cxJT Ta . ' mble, L�'r t; p';-2t IN%11,,,.AT©11 . J 1,,` r1,49414 t✓xl 51-I1cid e „4•..--,, � .: e cl&l..._ - ./ . _ _-- 44---•. _________ __ --1 1-- VI 170U el.. .Zxia . . u 2x1 o 17-.1 Jo IT.. ... .... 1 /. 41. . . .. . . . ul r ' _ TM= 2.>;l©JOl,T? rA • ?jXlCr (� / /( 1._._ '" tltkc4P. 'r?) r ` t 11..1 . Icee:).G. ii . .._. . u ^ -.30. L. — .._ . . ....._ ...._ ._ _ o a — =;� — = `— - =4 �'i '-�Win) — — —-- - i(\ o / T Z � � I I ' �ir l__4t1-i_ ni1.1.11.-2:11k 5:-- .4 l, , Itic ..�. VAP, 13AFf-,l e.F-, %'—ltt� ,— ,ti ---7:7-7:1511 .! Itt 1I I_. 24 24_X.(o -17-- I �� � roc�lt4 u} 3 e, 5 4% o V ', N rxlttco; \� 91-.0> To 5E. ► Mc.`D . # e-XCAV,\Tcg- Under Floor Ventilation �e"4 r•N Q. - GZKL 25, 10 412-4)\1112e- .\14 . . . 1 Sq Ft per every 150 Sq Ft of under I"- - AsGGG2l1L\Te. G4..\\/L. SrAE.,__ floor space area. 1 ventilating opening =hall < • o ALL FOOTINGS MUST BE CONTINUOUS be within 3 feet of each comer.Openin,- W shall be covered with approved materia. FOUNDATION WALLS-3000# PSI ‘'+i 0 SLABS, GARAGES,CARPORTS 5Ccit 014 ',L -1s, ...----Under floor accessible •.I, -- =I. c) • &PORCHES-3500#PSI . ,�L.>✓: /L���'-c . Y _ x 24" • © b Under floor a r1ParanrP 1R" Minimum depth for frost protection in the City of Radon Mitigation System Required Spokane Valley is 24 inches measured from the bottom If Vents Subject to Closure of the footing to finish grade. Grade slope away from 6 mil Vapor Barrier Required building a minimum 6 inches in first 10 feet. fpr 23 07 01 : 42p QC Manager 801 825-5903 p. 4 ADULT LIVING HOME REMODEL PROJECT NOTES: 1- Dimensions are from inside face of, existing, 2x4 stud walls. 2- Interior wall dimensions from face of studs. 3- Indicates garage door, man door and window that are to be removed and frames in. 4- ,& 'z _Indicates existing exterior 2x4 walls that are to be furred out to accommodate R-21 insulation. 5- All new doors are to be 3°x 68. 6- Windows in bedroom are to be sized to meet fire egress requirements. 7- Existing door to be removed to accommodate passage way from existing house. (1 101 /�1'^'fit{/ ,�ryy „i 1 { \: 3 ,tiU k� ii f� .I FY 4f�. ettiotT33fIfiCyjVO T,.1 s` f` PROVIDE DIAGRAMS AND ENGINEERING LAYOUTS FOR ROOF TRUSSES, BEAMS AND FLOOR SYSTEMS PRIOR TO FRAMING INSPECTIONS CITY COPY THIS BUILDING SUBJECT TO FIELD INSPECTION CORRECTIONS REVIEWEDSj' . IIeY FOR CODE COMPLIANCE SPOKANE VALLEY B ILDI DIVISION