2007, 05-24 Permit App: 07001950 Addition Project Number: 07001950 Inv: 1 Application Date: 5/24/2007 Page 1 of 2
THIS IS NOT A PERMIT
Penalties will be assessed for commencing work without a permit
Project Information:
Permit Use: CONVERT GARAGE INTO LIVING RM Contact: KEELY CONSTRUCTION
Address: PO BOX 30003
C-S-Z: SPOKANE,WA 99223
Setbacks:Front Left: Right: Rear: Phone: (509)869-6434
Group Name:
Site Information: Project Name:
. ..
Plat Key: 002873 Name: WEST VALLEY ADD District: Nort
Parcel Number: 45074.0346 Block: Lot:
SiteAddress: 2010 N VISTA RD Owner:Name: WILLIAMS,JOAN A
Address: 2010 N VISTA RD
Location::CSV SPOKANE,WA 99212-2417
Zoning: UR-3.5 Urban Residential 3.5
Water District: 100 SPO CO WATER DIST#3A Hold: ❑
Area: 12,095 Sq Ft Width: 0 Depth: 0 Right Of Way(ft): 0
Nbr of Bldgs: 0 Nbr of Dwellings: 0
Review Information: u .. arariv-I-mtgazsmos
Review
Building Plan Review Released`py ` "*4 S' X. 07
Building Permit
Contractor: KEELY CONSTRUCTION Firm: KEELY CONSTRUCTION
Address: PO BOX 30003 Phone: (509)869-6434
SPOKANE,WA 99223
This Application: Total Project:
Description Grp Type Notes So Ft Valuation SQ Ft Valuation
RES ADD R-3 VB o600 $54,816.00 600 $54,816.00
Totals: 600 $54,816.00 600 $54,816.00
Item Description Units Unit Desc Fee Amount
RESIDENTIAL PERMIT FEE 1 SELECT $678.75
WSBC SURCHARGE 1 SELECT $4.50
SF PLNS RVW<7999 SQ FT 1 SELECT $271.50
Permit Total Fees: $954.75
Operator: JD Printed By: JD Print Date: 5/24/2007
Project Number: 07001950 Inv: 1 Application Date: 5/24/2007 Page 2 of 2
THIS IS NOT A PERMIT
Penalties will be assessed for commencing work without a permit
Payment Summary a x.•a � r n s as ,< r_ a e ..... .a.r r � ., ti
Permit Type Fee Amount Invoice Amount Amount Paid Amount Owing
Building Permit $954.75 $954.75 $0.00 $954.75
$954.75 $954.75 $0.00 $954.75
Disclaimer:
Submittal of this application certifies the owner(or person(s)authorized by the owner)has both examined and finds the information
contained within to be true and correct,and agrees that all provisions of laws and/or regulations governing this type of work will be
complied with. Subsequent issuance of a permit shall not be construed to be a permit for,or an approval of,any violation of any of
the provisions of the code or of any other state or local laws or ordinances.
Signature:
Operator: JD Printed By: JD Print Date: 5/24/2007
'. Permit Center (�J
ScrrroF °� 11703 E Sprague Ave, Suite B-3 PERMIT NUMBER: (CS-0
pokane Spokane Valley,WA 99206
jValley (509)688-0036 FAX: (509)688-0037 PERMIT FEE:
a www.spokanevalley.org
`
Community Development j '
Residential Cons; fiction New Construction Accessory Bldg
Permit Application`' MAY 2 2 2007 ,j&AddithwiRemodel Deck
'', ' r-7 Other:
SITE ADDRESS: O 1 V.`S --I
ASSESSORS PARCEL NO: LEGAL DESCRIPTION:
Building Owner: Contractor:
Name: O aJ (,u;kl: f,-,,e‘] Name: iic e Q(' cC3✓vS't1 v-s_., 0 ti
Address. Address: ,70 v
.�2c� i0 U � ./.'r ,� ..?6Go� q
City: S Po(L✓�, Q State: Zip: City: S Pcl ►4-, State: Lel A- Zip: ! 1 Z2`3
Phone:0Z+ 1 Fax: Phone: 6 b c.( 1 6 4 Fax: Q
J J Contractor Lic No: xp Date: ` Z
Contact Person City Business Lic.No: to
4,, 0i 0- 1.....A-2_
Name: 'f-✓'� IA'. I I,`/)--L.--O 1
Phone: 1 2 1 l'I 1
Describe the scope of work in detail: Cost of Project: $ ‘,.?/ a a' ()
Co v4./-e-r-kr G•/}ri�..a. a-N --it)
Li v i'A_.),3
Proposed Use: j.,,,.; ti Qov„/L
**************The following MUST be complete: (write N/A if not applicable)**********************
HEIGHT TO PEAK: 4/19.- DIMENSIONS #OF STORIES TOTAL HABITABLE SPACE:
MAIN FLOOR TO SQ. 2ND FLOOR SQ. FTG: UNFIN BASEMENT SQ. FTG: IMPERVIOUS SURFACE
FTG: /4— ,�- ti Imo' AREA:
/l/
SQ FINISHED FG BASEMEN GARA000 GE SQ. FTG: DECK/COV/1i SQ. FTG: 30%PROPERTYS ON,
#OF BEDROOMS: A„ CONSJRUCTION TYPE: HEAT SOURCE: SEWER OR SEPTIC?
C 401.4 g"L5 O 5.- 0 3 C
The permitee verifies,acknowledges and agrees by their signature that: 1) If this permit is for construction of or on a dwelling,the
dwelling is/will be served by potable water. 2) Ownership of this City of Spokane Valley Permit inure to the property owner. 3) The
signatory is the property owner or has permission to represent the property owner in this transaction. 4) All construction is to be done
in full compliance with the City of Spokane Valley Development Code. Referenced codes are available for review at the City of
Spokane Valley Permit Center. 5) This City of Spokane Valley Permit is not a permit or approval for any violation of federal,state or
local laws,codes or ordinances.6) Plans or additional information may be required to be submitted, and subsequently approved before
this application can be processed. y� ip
2ogSIGNATURE: , , , 'DATE: 2--e 2)
Method of Payme .
❑ Cash ipel Check ❑ Mastercard 0 VISA
Bankcard#: Expires: VIN#:
Authorized Signature:
REVISED 2/15/07
son Oyu
pokane
Valley®
11703 E Sprague Ave Suite B-3 • Spokane Valley WA 99206
509.688.0036 • Fax: 509.688.0037 ♦ cityhall@spokanevalley.org
Residential Plan Submittal Minimums
❑ Completed Building & Mechanical application with: Accurate address, Parcel
Number and/or Legal Description, description of work, owner and contractor
information, signature, and date.
❑ Two sets of plans including Site Plan, elevations, floor plans, foundation plans
With details, roof plan, framing plans & details.
❑ Show the height of any proposed buildings or accessory structures.
❑ Floor plan for each floor: Dimension to scale (minimum 1/8") and label each
Room (including sq. footage of house and garage on plans) Show each
level of existing house and square footage of any additions.
❑ All braced wall panel types: show locations and details of installation, including
engineered design.
❑ Egress windows: Provide at least one window or exterior door approved for
Emergency escape or rescue from a basement and in every room for sleeping.
❑ Smoke detector locations
❑ 22" X 30" attic access location
❑ 18" X 24" crawl space access:
❑ One-hour separation detail: between house and garage
❑ Floor framing details: Joist type, size, spacing and installation details
❑ Roof framing plan and details
❑ Furnace and hot water heater location.
❑ All header locations: type, size, and connections
❑ Foundation plan
❑ Insulation information
WSEC TABLE 6-2
PRESCRIPTIVE REQUIREMENTS°4 FOR GROUP R OCCUPANCY
CLIMATE ZONE 2
Glazing Glazing U-Factor Door-9 Walla Wall? Walla Slab6
Option Area10: U- Ceiling2 Vaulted
Ceiling3 Above Below Below
Floors on
of floor Vertical Overhead" Factor Grade Grade Grade Grade
10% 0.40 0.58 0.20 R-38 R-30 R-21 R-21 R-12 R-30 R-10
int'
II. 15% 0.40 0.58 0.20 R-38 R-30 R-19+ R-21 R-12 R-30 R-10
R-58
III. 17% 0.37 0.58 0.20 R-38 R-30 R-19+ R-21 R-12 R-30 R-10
R-58
IV. 25% 0.35 0.58 0.20 R-381 R-30/ R-21 R-15 R-12 R-30/ R-101
Group R-1 U=0.031 U=0.034 int'/ U=0.029 F=0.54
Occupancy U=0.054
Only
V. Unlimited 0.35 0.58 0.20 R-38 R-30 R-21 R-21 R-12 R-30 R-10
Group R-3 int'
Occupancy
Only
VI. Unlimited 0.32 0.58 0.20 R-38/ R-30/ R-21 R-15 R-12 R-30/ R-10/
Group R-1 U=0.031 U=0.034 int'/ U=0.029 F=0.54
Occupancy U=0.054
Only
* Reference Case
0. Nominal R-values are for wood frame assemblies only or assemblies built in accordance with
Section 601.1.
1. Minimum requirements for each option listed. For example, if a proposed design has a glazing ratio
to the conditioned floor area of 13%, it shall comply with all of the requirements of the 15% glazing
option(or higher). Proposed designs which cannot meet the specific requirements of a listed option
above may calculate compliance by Chapters 4 or 5 of this Code.
2. Requirement applies to all ceilings except single rafter or joist vaulted ceilings.
3. Requirement applicable only to single rafter or joist vaulted ceilings.
4. Below grade walls shall be insulated either on the exterior to a minimum level of R-10, or on the
interior to the same level as walls above grade. Exterior insulation installed on below grade walls
shall be a water resistant material,manufactured for its intended use, and installed according to the
manufacturer's specifications. See Section 602.2.
5. Floors over crawl spaces or exposed to ambient air conditions.
6. Required slab perimeter insulation shall be a water resistant material,manufactured for its intended
use, and installed according to manufacturer's specifications. See Section 602.4.
7. Int. denotes standard framing 16 inches on center with headers insulated with a minimum of R-5
insulation.
COOPERATIVE EXTENSION
WSEC Builder's Field Guide 5th Edition WASHINGTON STATE UNIVERSITY 1-7
ENERGY PROGRAM
. BUILDING PLANNING
rating of not less than the required fire-resistance rating 2. Where the framed cavity or space is ventilated to al-
of the wall or floor/ceiling assembly penetrated. low moisture to escape.
R317.3.2 Membrane penetrations. Membrane penetra- 3. In counties identified with footnote a in Table
tions shall comply with Section R317.3.1.Where walls are N1101.2.
required to have a minimum 1-hour fire resistance rating,re-
cessed luminaire shall be so installed such that the required
fire resistance will not be reduced. SECTION R319
PROTECTION AGAINST DECAY
Exceptions:
1. Steel electrical boxes that do not exceed 16 square R319.1 Location required.In areas subject to decay damage
inches(0.0103m2)in area provided the total area of as established by Table R301.2(1), the following locations
such openings does 100 inches shall require the use of an approved species and grade of lum-
ch(0.0645 m2 forsany not exceedefeet (square m2) of ber, pressure treated in accordance with AWPA Cl, C2, C3,
C4,C9,C15,C18,C22,C23,C24,C28.C31,C33,P1,P2 and I
wall area. Outlet boxes on opposite sides of the P3,or decay-resistant heartwood of redwood,black locust,or
wall shall be separated as follows: cedars.
1.1. By a horizontal distance of not less than 24 1. Wood joists or the bottom of a wood structural floor
inches (610 mm); when closer than 18 inches (457 mm) or wood girders
1.2. By a horizontal distance of not less than the when closer than 12 inches (305 mm) to the exposed
depth of the wall cavity when the wall cav- ground in crawl spaces or unexcavated area located
ity is filled with cellulose loose-fill, within the periphery of the building foundation.
rockwool or slag mineral wool insulation; 2. All wood framing members that rest on concrete or ma- I
1.3. By solid fire blocking in accordance with sonry exterior foundation walls and are less than 8 inches
Section R602.8.1; (203 mm)from the exposed ground.
1.4. By protecting both outlet boxes by listed 3. Sills and sleepers on a concrete or masonry slab that is in
putty pads;or direct contact with the ground unless separated from
1.5. By other listed materials and methods. such slab by an impervious moisture barrier.
2. Membrane penetrations for listed electrical outlet 4. The ends of wood girders entering exterior masonry or
boxes of any materials are permitted provided such concrete walls having clearances of less than 0.5 inch
boxes have been tested for use in fire renis- (12.7 mm)on tops, sides and ends.
tance-rated assemblies and are installed in actor- 5. Wood siding,sheathing and wall framing on the exterior
dance with the instructions included in the listing. of a building having a clearance of less than 6 inches(152
Outlet boxes on opposite sides of the wall shall be mm)from the ground.
separated as follows: 6. Wood structural members supporting moisture-perme-
2.1. By a horizontal distance of not less than 24 able floors or roofs that are exposed to the weather,such
inches(610 mm); as concrete or masonry slabs,unless separated from such
2.2. By solid fire-blocking in accordance with floors or roofs by an impervious moisture barrier.
Section R602.8; 7. Wood furring strips or other wood framing members at-
2.3. By protecting both outlet boxes by listed tached directly to the interior of exterior masonry walls
putty pads;or or concrete walls below grade except where an approved
2.4. By other listed materials and methods. vapor retarder is applied between the wall and the furring
3. The annular space created by the penetration of a strips or framing members.
fire sprinkler provided it is covered by a metal es R319.1.1 Ground contact. All wood in contact with the
cutcheon plate. ground and that supports permanent structures intended for
human occupancy shall be approved pressure preservative
treated wood suitable for ground contact use, except un-
SECTION R318 treated wood may be used where entirely below groundwa-
MOISTURE VAPOR RETARDERS ter level or continuously submerged in fresh water.
R318.1 Moisture control.In all framed walls,floors and roof/ R319.1.2 Geographical areas. In geographical areas
ceilings comprising elements of the building thermal envelope, where experience has demonstrated a specific need, ap-
a vapor retarder shall be installed on the warm-in-winter side of proved naturally durable or pressure preservatively treated
the insulation. wood shall he used for those portions of wood members that
form the structural supports of buildings,balconies,porches
Exceptions: or similar permanent building appurtenances when such
1. In construction where moisture or freezing will not members are exposed to the weather without adequate pro-
damage the materials. tection from a roof, eave, overhang or other covering that
2003 INTERNATIONAL RESIDENTIAL CODE® 55
p
_....,_.J )'• ',/ .
s*$
c 5__ :. 1
-+';✓I
..„*\°‘61\,/s ,
II
IN tic �,~ . �0' 1l l , 1:W4)-41a� � L \....
� •
,til l?11r ,,a•S h' �Z / " ,
fl•1 M
If
f
lr
a 11
1/3 , '
E
y\ fa -\C-J ., 413 ,
i
' 1 IIi
I
I
,
t N1101.3.1 –Attic insulation certification required as to
[ R–value or coverage. Markers, attached to trusses or . Attic ventilation r;
EMERGENCY EGRESS REQUIREMENTS
FROM SLEEPING ROOMS rafters, required for every 300 sf of attic space with 1 1 Sq Ft per every 300 Sq Ft of space
ventilated with at least 50%in the u
•
1)NET CLEAR OPENING 5.7 SQUARE FEET inch high numbers for installed thickness of insulation. portion of roof area. pper .
GRADE Ft.DOR OPENING(MAX 44•) 5 0 SQUARE FEET
2)NET CLEAR OPENING HEIGHT 24 INCHES Attic Accessible /
3)NET CLEAR OPENING WIDTH 2O INCHES
a)MAX FINISHED SILL HEIGHT aa•ABOVE FLOOR CEILING: 1/2" GWB if perpendicular to rafters or by 22' x 30"
/V'
51 EMERGENCY ESCAPE&RESCUE OPENING SHALL BE trusses 24" o.c. and no water based texture used—
OPERATIONAL FROM THE INSIDE OF THE ROOM WITHOUT otherwise 5/8" GWB.
THF USF OF KEYS OR TOOLS J0#_felt for ice`
dam protection
ro 2 4 wScoc� if,
WHEN INTERIOR ALTERATIONS,REPAIRS OR ADDITIONS 1 ,t-`R &A�
-- ,� '0.:) �- i eco/l ,.�} .,.tA'1-*
REQUIRING A PERMIT OCCUR,OR WHEN ONE OR MORE ----: �� r iNS
SLEEPING ROOMS ARE ADDED OR CREATED IN EXISTING C...) " 1/"'°I rya CO 7 Z -C...4)64.,
DWELLINGS,THE DWELLING UNIT SHALL BE PROVIDED ,..�l —n c , -, __ U 06 , '� ..--
WITH
.•
WITH SMOKE ALARMS LOCATED AS REQUIRED FOR NEW Cs = Lig r,./'"` -�
SMOKE I ALSctoARMS SHALL BE INTERCON- S (t,) I$ '''"l,f _._.__
NECTED AND HARD WIRED IN SUCH A •" cam=,-�
All cx
MANNER THAT THE ACTIVATION OF ONE CI f L -- �'' x
ALARM WILL ACTIVATE ALL. ALARMS. t— B
LLI
(BEDROOMS. AREAS APPROACHING ) ��� c �
BEDROOMS , VAULTED CEILING .* W'')
WITH RISE OF 24'& ON EACH FLOOR) 0 11 ! —
q r
F`Ms r
..t^w7a .D�
04
'1 ( .L 6 )' tea
..--• mir...._
Anchor Bolts- Minimum 1/2"x 10"with 7"concrete 7/7 , / -s
embedment at 6' o.c. and 12" from ends of sill plates. 51 -- �, ,
"...._
Radon Mitigation System Required Under Floor Ventilation
1 Sq Ft per every 150 Sq Ft of under
If Vents Subject to Closure floor space area. 1 ventilating opening shall
6 mil Vapor Barrier Required be within 3 feet of each corner.Openings
shall be covered with approved material.
, 7.0., 43A_itioiel:13‹-...i1,7‘:),....3 ._ ,,-", f•lki: ,
. .
0 (f) C:491000..o.4,1i3i2 A.4f-f -
. Z
2 0
<
1/114 .. A
CC 1. . 5 CI) '.-1 iirif"•'.
..J 5
fri.,,-.. cr a u_ —c,
0 Z 0 owiL:::114 0-LU .1,1 --.., . Tlialiti i't:'
0 Li_ < i__ 111. 1;9,03J0234.5 ;w"...:4
ZOWCC SIN)
< /— 2 0
cr) ,a ' t, --14 31,41' 4,"3rt,ini 3p,-
6' w '..rt - • ' ' ,, .,
..1.:t, ,' , • ? 0 cc —
.c(1) OLLICC
II
r cc.,,lc. - '
>- co 0_
., ... < < . cn 111114
CC --• co 2 2-6
0www
€1114 = p
._< z u) I— oft.,4 L.I r 1
MI LLI cc u) 1.7
8 (DO 8 Lti. C,) zattiMAjA
' get' rt:]kiz A.4 0-3ito-k. i,!,00.,r1 47M.fik
0- l.U CC U- Z = 0 _1'10 :4.0 A-DI,iskVi'''A, .47 1`.4.f:v
'M:.4 A j 11.. ':._IA 4 'AV• 1A _1.4i.,
'PA .Zh4001 .`Tit.,
U. -...• A ; I i .-; (1" 1 I .41 I i i
0
I--