Loading...
1991, 09-19 Permit: 93004829 Energy Code Compliance • - WA*SUN 5. 1 1991 WA STATE ENERGY CODE COMPLIANCE REPORT 09/19/91 FILE: B:\CALSPLIT.WS HOUSE ID: CAL SPLIT A Plan Reviewed By: _-`______" - - D.Fenton This plan review is provided for information Analyst: DF purposes only, and does not guarantee r i sd i G_t i on compliance with local, state or federal 1Jt.i.1.i.ty : WWP codes or requirements. Mail : Floor Area: 1984 ft2 Builder: HOMESTEAD CONSTRUCTION Weather Data: Spokane, WA Address: Climate Zone: 2 ____._._. _._ _____.______...._.-____-_____ • The PROPOSED design *COMPLIES* with 1991 WA State Energy Code. ' REFERENCE PROPOSED COMPONENT PERFORMANCE 31.9 316 Btu/hr-F ENERGY BUDGET 5. 1 5 5.34 kWh/kWh/ft2--yr REFERENCE DESIGN _.----- -- =- - Component Reference Value X Area = UA BO Wal 1 U-0.041 462 18.9 BG Slab F- 0.640G Floor 132ft 84 . 5 Glazing C15'/. U-0.400 297.6 119.0 Doors U-0.200 20.0 4.0 AG Wall U-0.044 1368 60.2 Ceiling U-0.031 10082 Infiltration 1. Reference UA 319 PROPOSED DESIGN COMPONENTS r - _Component-_-----Description Value X Area = UA BG Wall R19 batt 3. 5' depthU-0.041 462 18.9 BG Slab F-0.640 132ft 84. 5 Floor R30 unvented Joist 16oc U-0.029 72 0.9 Glazing @127 **WP VINYL 2 GL LOW E U-0.390 237.0 92.4 Doors Metal R-5 base case U-0. 190 20.0 3.8 AG Wall R19 STD Lap Wood U-0.062 1429 88.6 Ceiling R49 blown Attic STI) baffled U-0.027 1008 27. 2 Infiltration Standard Air Sealing ACH-0.350 12976ft3 ( 78.6) Proposed UA 316 Items in parentheses not included in COMPONENT PERFORMANCE totals. ** Denotes non-standard values - check calculation of thermal value. __ :_. - Page 1 = - _._. WATTSUN . 1 1991 WA STATE ENERGY CODE COMPLIANCE REPORT 09/19/91. FILE: B: \CALSPL I T.WS HOUSE ID: CAL SPLIT A Struc Mass Light Frame, Sheetrock walls M-3.000 1984 5952.0 HEATING/COOLING/VENTILATING SYSTEMS PROPOSED Heating System Type: Electric: Zoned Make: Model : System Efficiency : 100 Modified Efficiency : 100 Heating Load(at 66F dt) : 29772 Btu/hr System Size: 8.7 kW Maximum Size @1507.: 13.1 kW Average Annual Heat: 1:7.74 kwh Annual Cost: $ 758 Ventilation Type: Non-Heat Recovery Option: Option 1 Cooling Load(at 12F dt) : 24796 Btu/hr Recommended Size @1257.: 2.9 tons Solar Access: Partially Shaded • GLAZING ORIENTATION PROPOSED PROPOSED South: 59.2 ft2 North: 59.2 ft2 Southeast: 0.0 Northwest: 0.0 East: 59.2 West: 59.2 Northeast: 0.0 Southwest: • 0.0 =====C{ = === = ====___=__== _ -..• Economic and energy consumption estimates are designed for comparative purposes only . Actual cost for heating will vary depending on weather conditions, occupant lifestyle and other factors. �__:=___ _-...-_____._ .____= •-- --____ Fagg, 2 ��.�..__-_. -___- •