1991, 09-19 Permit: 93004829 Energy Code Compliance •
- WA*SUN 5. 1 1991 WA STATE ENERGY CODE COMPLIANCE REPORT 09/19/91
FILE: B:\CALSPLIT.WS HOUSE ID: CAL SPLIT A
Plan Reviewed By: _-`______" - -
D.Fenton
This plan review is provided for information
Analyst: DF
purposes only, and does not guarantee r i sd i G_t i on
compliance with local, state or federal 1Jt.i.1.i.ty : WWP
codes or requirements.
Mail : Floor Area: 1984 ft2
Builder: HOMESTEAD CONSTRUCTION Weather Data: Spokane, WA
Address: Climate Zone: 2
____._._. _._ _____.______...._.-____-_____
•
The PROPOSED design *COMPLIES* with 1991 WA State Energy Code.
' REFERENCE PROPOSED
COMPONENT PERFORMANCE 31.9 316 Btu/hr-F
ENERGY BUDGET 5. 1 5 5.34 kWh/kWh/ft2--yr
REFERENCE DESIGN _.----- -- =- -
Component Reference
Value X Area = UA
BO Wal 1 U-0.041 462 18.9
BG Slab F- 0.640G
Floor
132ft 84 . 5
Glazing C15'/. U-0.400 297.6 119.0
Doors U-0.200 20.0 4.0
AG Wall U-0.044 1368 60.2
Ceiling U-0.031 10082
Infiltration 1.
Reference UA 319
PROPOSED DESIGN COMPONENTS r -
_Component-_-----Description Value X Area = UA
BG Wall R19 batt 3. 5' depthU-0.041 462 18.9
BG Slab F-0.640 132ft 84. 5
Floor R30 unvented Joist 16oc U-0.029 72 0.9
Glazing @127 **WP VINYL 2 GL LOW E U-0.390 237.0 92.4
Doors Metal R-5 base case U-0. 190 20.0 3.8
AG Wall R19 STD Lap Wood U-0.062 1429 88.6
Ceiling R49 blown Attic STI) baffled U-0.027 1008 27. 2
Infiltration Standard Air Sealing ACH-0.350 12976ft3 ( 78.6)
Proposed UA 316
Items in parentheses not included in COMPONENT PERFORMANCE totals.
** Denotes non-standard values - check calculation of thermal value.
__ :_. - Page 1 = - _._.
WATTSUN . 1 1991 WA STATE ENERGY CODE COMPLIANCE REPORT 09/19/91.
FILE: B: \CALSPL I T.WS HOUSE ID: CAL SPLIT A
Struc Mass Light Frame, Sheetrock walls M-3.000 1984 5952.0
HEATING/COOLING/VENTILATING SYSTEMS
PROPOSED
Heating System Type: Electric: Zoned
Make:
Model :
System Efficiency : 100
Modified Efficiency : 100
Heating Load(at 66F dt) : 29772 Btu/hr
System Size: 8.7 kW
Maximum Size @1507.: 13.1 kW
Average Annual Heat: 1:7.74 kwh
Annual Cost: $ 758
Ventilation Type: Non-Heat Recovery
Option: Option 1
Cooling Load(at 12F dt) : 24796 Btu/hr
Recommended Size @1257.: 2.9 tons
Solar Access: Partially Shaded •
GLAZING ORIENTATION
PROPOSED PROPOSED
South: 59.2 ft2 North: 59.2 ft2
Southeast: 0.0 Northwest: 0.0
East: 59.2 West: 59.2
Northeast: 0.0 Southwest: • 0.0
=====C{ = === = ====___=__== _ -..•
Economic and energy consumption estimates are designed for comparative
purposes only . Actual cost for heating will vary depending on weather
conditions, occupant lifestyle and other factors.
�__:=___ _-...-_____._ .____= •-- --____ Fagg, 2 ��.�..__-_. -___-
•